WRB-YT-1W

WRB-YT-1W Series
1W, WIDE INPUT, ISOLATED & REGULATED SINGLE OUTPUT DC/DC CONVERTER
SELECTION GUIDE
order code
Input
Input
Voltage
Current
Output
Current
Output
(VDC)*
(mA)
Voltage
(mA)
Effciency
MTTF
(%)
(kHrs)
(VDC)
FEATURES
Efficiency from 60.5%
◆
Operating temperature: -40°C ~ +85°C
◆
1000VDC isolation
Nominal
0%Load
100%Load
100%Load
Min.
Typ.
WRB0505YT-1W
5
25
320
05
200
60.5
62
921
WRB0512YT-1W
5
30
300
12
83
63.5
67
1118
WRB0515YT-1W
5
60
320
15
66
60.5
63
869
WRB1205YT-1W
12
10
110
05
200
68.0
73
1281
WRB1212YT-1W
12
12
130
12
83
65.0
66
1175
WRB1215YT-1W
12
15
120
15
66
65.0
67
1283
WRB2405YT-1W
24
6
120
05
200
65.0
70
1379
WRB2412YT-1W
24
8
60
12
83
65.0
68
1278
WRB2415YT-1W
24
9
60
15
66
65.0
67
1223
Max.
Units
245
℃
◆
UL94V-0 package material
◆
No external component required
◆
Internal SMD construction
◆
MTBF>1,400,000 hours
◆
RoHS Compliance
◆
* Input voltage can not exceed this value, or will cause the permanent damage.
Lead frame technology
◆
5V,12V&24V Input
◆
5V,12V&15V Output
◆
COMMON SPECIFICATIONS
◆
Power density 0.7W/cm3
◆
Multi layer ceramic capacitors
Item
Input voltage
MODEL SELECTION
①
②
③
④
⑤
⑥
WR
WRB
B 12 05 Y T -1W
①Product Series
②Input Voltage
③Output Voltage
④Wide (2:1) Input Range
⑤SMD14 Package Style ⑥Rated Power
Test conditions
Min.
WRB05XXYT-1W types
10V
WRB12XXYT-1W types
17.5V
WRB24XXYT-1W types
40V
Minimum load
See graph
Lead temperature
1.5mm from case for 10 seconds
Cooling
Free air convection
Free air convection
Short circuit protection
15s
Case material
DESCRIPTION
Epoxy Resin (UL94-V0)
Operation
℃
30
Case temperature rise above ambient
The WRB-YT-1W series are specially
designed for applications where a wide range
input voltage power supplies are isolated from
the input power supply in a distributed power
supply system on a circuit board.
These products apply to:
1) Where the voltage of the input power supply
is wide range (voltage range ≤2:1);
2) Where isolation is necessary between input
and output (Isolation Voltage ≤1000VDC);
3) Where the regulation of the output voltage
and the output ripple noise are demanded.
See derating graphs
Storage
-40
85
-50
130
All specifications typical at TA=25ºC, nominal input voltage and rated output current unless otherwise specified.
INPUT CHARACTERISTICS
Item
voltage range
MICRODC RESERVES THE COPYRIGHT
Reflected ripple current
http://www.microdc.cn
Typ.
Test conditions
Min.
Typ.
Max.
Units
Continuous operation, 5V input types
4.5
5
9
V
Continuous operation, 12V input types
9
12
18
V
Continuous operation, 24V input types
18
24
36
V
See graph
12
mA p-p
1.5mm from case for 10 seconds
6
mA p-p
Free air convection
6
mA p-p
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 5
WRB-YT-1W Series
TEMPERATURE DERATING
ISOLATION SPECIFICATIONS
Item
Test Conditions
Min.
Isolation voltage
Tested for 1 minute and 1mA max
1000
Isolation resistance
Test at 500VDC
1
Isolation capacitance
Typ.
Max.
Units
WRB2405YT-1W
VDC
10
GΩ
25
pF
*Supply voltage must be discontinued at the end of short circuit duration.
OUTPUT SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
Max.
Units
Output power
Refer to products program
1
W
Voltage set point accuracy
With external input/output capacitors
±1
±2
%
Load regulation
10% load to 100% load, with external input/output capacitors
0.1
1
%
Line regulation
Low line to high line
0.2
1
%
±10
%/℃
150
mVp-p
700
kHz
Voltage trim range
Ripple & noise
0.1
-10
20MHz Bandwidth,all output types
Switching frequency
100
50
WRB2412YT-1W
APPLICATION NOTE
ISOLATION VOLTAGE
“Hi Pot Test”,“Flash Tested”,“Withstand Voltage”, “Proof Voltage”, “Dielectric Withstand Voltage” &
“Isolation Test Voltage” are all terms that relate to the same thing, a test voltage, applied for a specify
time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
WRB-YT-1W series of DC/DC converters are all 100% production tested at their stated isolation
voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part
in normal operation?”
For a part holding no specific agency approvals, such as the WRB-YT-1W series, both input and
output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The
isolation test voltage represents a measure of immunity to transient voltages and the part should never
be used as an element of a safety isolation system. The part could be expected to function correctly with
several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on
both sides of the barrier must be regarded as operating at an unsafe voltage and further
WRB2415YT-1W
isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry
according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually
degrade isolation capability, to a lesser or greater degree depending on materials, construction and
environment. The WRB-YT-1W series has toroidal isolation transformers, with no additional insulation
between primary and secondary windings of enameled wire.
While parts can be expected to withstand
several times the stated test voltage, the isolation capability does depend on the wire insulation. Any
material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation
when subject to very high applied voltages thus implying that the number of tests should be strictly
limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely
required, that the voltage be reduced by 20% from specify test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation
where the wire enamel insulation is always supplemented by a further insulation system of physical
spacing or barriers.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 2 of 5
WRB-YT-1W Series
TEMPERATURE DERATING
WRB0505YT-1W
WRB0512YT-1W
WRB0515YT-1W
WRB1205YT-1W
WRB1212YT-1W
WRB1215YT-1W
WRB12XXYT-1W
WRB24XXYT-1W
MINIMUM LOAD
WRB05XXYT-1W
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 3 of 5
WRB-YT-1W Series
APPLICATION NOTES
Recommended input&output capacitors
Although these converters will work without external capacitors, they are
Value
necessary in order to guarantee the full parametric performance over the full
Cin
Cout
10μF, 200V
22μF, 16V
good low esr capacitor
good low esr capacitor
line and load range. All parts have been tested and characterized using the
following values and test circuit.
Test circuit, 5V, 12V and 15V output
ON/OFF Pin
This provides an OFF function, which puts the converter into a low power mode. When the pin is un-connected, the converter is on. The circuit used must be able to sink a peak
current of 50mA to guarantee turning the converter off. The circuit should be an open collector arrangement, an example circuit is shown below. Voltages should not be applied
directly to the ON/OFF pin. The BC547 should be fited close to the WRB-YT-1W ON/OFF pin to prevent the addition of excess wiring capacitance.
CONTROL PIN CIRCUIT INPUT VOLTAGE VCONTROL
Min.
Max.
Units
Module ON
0
0.2
V
Module OFF
1.6
30
V
Output voltage adjustment
The trim resistor equations are:
Where:
G
L
K
WRB0505YT-1W
30100
1.24
3.76
WRB1205YT-1W,WRB2405YT-1W
100000
1.24
3.76
WRBXX12YT-1W
38300
2.5
9.5
WRBXX15YT-1W
49900
2.5
12.5
TRIM UP
TRIM DOWN
When the output voltage is trimmed up, output current must be derated so that the maximum output power is not exceeded.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 4 of 5
WRB-YT-1W Series
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
RECOMMENDED FOOTPRINT
MECHANICAL DIMENSIONS
All dimensions in inches ±0.02 (mm ±0.5mm).
TUBE OUTLINE DIMENSIONS
All dimensions in inches ±0.01 (mm ±0.25mm). All pins on a 0.1 (2.54) pitch
Weight: 2.8g
FOOTPRINT DETAILS
Pin
Function
Pin
Function
1
-Vin
14
NA
3
+Vin
16
TRIM
5
NA
18
NA
9
NA
22
ON/OFF
11
-Vo
24
NA
13
+Vo
26
NA
All dimensions in inches ±0.02 (mm±0.5).
NA:Not available for electrical connection.
Tube length: 18.70±0.079 (475±2.0).
Tube Quantity : 25
Note:
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
2.
Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
3.
Capacitor MAX load tested at input voltage range and full load.
4. All specifications measured at Ta=25℃, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
5.
Only typical models listed, other models may be different, please contact our technical person for more details.
6.
In this datasheet, all the test methods of indications are based on corporate standards.
RoHS COMPLIANT INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature
of 300°C for 10 seconds.
The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin
with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this
series are backward compatible with Sn/Pb soldering systems.
Microdc Professional Power Module,Inc.
Tel:0086-20-86000646
REACH COMPLIANT INFORMATION
E-mail:[email protected]
Website:http://www.microdc.cn
http://www.microdc.cn
This series has proven that this product does not contain harmful chemicals, it also has
harmful chemical substances through the registration, inspection and approval.
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 5 of 5