FTA550F XG Jockey Pump Controllers Model Number Selection Guide FTA550F XG JOCKEY PUMP CONTROLLERS FTA550F-A G __ __ __ __ - __ (Example: FTA550F-AG015B-T-BY) FTA NUMBER FTA550F OPTIONS & MODIFICATIONS (See other side) TIMER OPTION -A With Programmable Running Period Timer VOLTAGE 3-PHASE (50/60 Hertz) MOTOR CURRENT PROTECTION -G Manual Motor Protector *Suitable for Use as Service Equipment* Short Circuit Current Rating 3 Phase --200-480V - 30kA /600V - 18kA 1 Phase -- 110-240V - 5kA HORSEPOWER (KW) 014 - 1/4 HP (.18) 013 - 1/3 HP (.23) 012 - 1/2 HP (.37) 034 - 3/4 HP (.56) 001 - 1 HP (.75) 011 - 1 1/2 HP (1.1) 002 - 2 HP (1.5) 003 - 3 HP (2.2) 004 - 4 HP (3) 005 - 5 HP (3.7) 006 - 5 1/2 HP (4) 007 - 7 1/2 HP (5.5) 010 - 10 HP (7.5) 015 - 15 HP (11) 020 - 20 HP (15) -H -A -F -B -C 200-208 Volts 220-240 Volts 380-415V - WYE 440-480V - WYE 550-600V - WYE VOLTAGE 1-PHASE (50/60 Hertz) -D -T -E 110-120 Volts 200-208 Volts 220-240 Volts MAX HP 7.5 10 15 20 20 MAX HP 2 3 3 (See Voltage Selection for Maximum HP/Voltage Combinations) NOTE: For requirements not listed here (higher short circuit ratings, larger horsepowers, options not listed...etc) please refer to documentation for FTA550E series Jockey Pump Controllers. OPTIONS & MODIFICATIONS SPECIAL ENCLOSURES -T NEMA Type 3R (IEC IP22)* -E NEMA Type 4 (IEC IP66)* -F NEMA Type 4X (IEC IP66)* *Supplied with non-metallic enclosure ANTI-CONDENSATION SPACE HEATERS1 -J 120 Volt Space Heater With Thermostat -K 120 Volt Space Heater With Humidistat -M 240 Volt Space Heater With Thermostat -N 240 Volt Space Heater With Humidistat 1 Power source supplied by others PRESSURE TRANSDUCERS -B 0-600 psi (0-42,25 bar) Pressure Transducer for Fresh Water Service -C 0-300 psi (0-21.1 bar) Pressure Transducer for Corrosive Service -D 0-600 psi (0-42.25 bar) Pressure Transducer for Corrosive Service MISCELLANEOUS -AC Contacts for Remote Indication, Pump Run -AM Contacts for Remote Indication, Failed to Start -AST Auto Start Contacts (for connection to user supplied N.O. remote starting device) -BW Contacts for Remote Indication, Phase Failure/Reversal -BY Contacts for Remote Indication, Pump Overload -EF Contacts for Remote Indication, Switch Not In Auto -HV Audible Alarm (required if local audible alarm indication is desired). -IECI CE Marking (Internal Wet Parts) -KH Contacts for Remote Indication, Common Output for Any Alarm -NZ Interlock Input Contacts to Prevent Jockey Pump from Starting During Main Controller Operation -OSP OSHPD Seismic Certification (State of California) (Requires option -SEI) -S Tropicalization -SEI Seismic Certification (in accordance with IBC) -ZPA Customized, annual service display message (when factory programmed or programmed by Firetrol representative during start-up) -ZPJ Communications, Serial Modbus over RS485, 2 or 4 wire *Export Packaging available for additional cost NOTE: For requirements not listed here (higher short circuit ratings, larger horsepowers, options not listed...etc) please refer to documentation for FTA550E series Jockey Pump Controllers. Emerson Network Power - Global Headquarters 1050 Dearborn Drive Columbus, OH 43085 Tel +1 614 888 0246 ASCO Power Technologies - Firetrol Brand Products 111 Corning Road, Suite 120 Cary, NC 27518 Tel +1 1 460 5200 FaY +1 1 460 5250 EmersonNetworkPower.com Firetrol.com While every precaution has been taken to ensure accuracy and completeness herein, ASCO assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Information and specifications are subject to change without notice. Emerson, Consider It Solved., Emerson Network Power, the Emerson Network Power Logo, ASCO, Firetrol and the Firetrol Logo are trademarks or registered trademarks of Emerson Electric Co. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. ©2013 Emerson Electric Co. SD550F-01 (B)