V10WL45-M3 Datasheet

V10WL45-M3
www.vishay.com
Vishay General Semiconductor
Trench MOS Barrier Schottky Rectifier
Ultra Low VF = 0.33 V at IF = 5 A
FEATURES
®
TMBS
• Trench MOS Schottky technology
TO-252 (D-PAK)
• Ideal for automated placement
• Low forward voltage drop, low power losses
K
• High efficiency operation
• Meets MSL level 1, per J-STD-020, LF maximum peak
of 260 °C
NC
• Material categorization: For definitions of compliance
please see www.vishay.com/doc?99912
A
V10WL45
NC
A
TYPICAL APPLICATIONS
K
For use in high frequency DC/DC converters, switching
power supplies, freewheeling diodes, OR-ing diode, and
reverse battery protection.
HEATSINK
PRIMARY CHARACTERISTICS
MECHANICAL DATA
IF(AV)
10 A
VRRM
45 V
IFSM
100 A
VF at IF = 10 A (TA = 125 °C)
0.41 V
TJ max.
150 °C
Package
TO-252 (D-PAK)
Diode variation
Single die
Case: TO-252 (D-PAK)
Molding compound meets UL 94 V-0 flammability rating
Base P/N-M3 - halogen-free, RoHS-compliant, and
commercial grade
Terminals: Matte tin plated leads, solderable
J-STD-002 and JESD 22-B102
M3 suffix meets JESD 201 class 1A whisker test
per
Polarity: As marked
MAXIMUM RATINGS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
V10WL45
UNIT
Maximum repetitive peak reverse voltage
VRRM
45
V
Maximum average forward rectified current (fig. 1)
IF(AV)
10
A
Peak forward surge current 8.3 ms single half sine-wave
superimposed on rated load
IFSM
100
A
TJ, TSTG
-40 to +150
°C
Operating junction and storage temperature range
Revision: 04-Dec-13
Document Number: 89970
1
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
V10WL45-M3
www.vishay.com
Vishay General Semiconductor
ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
TEST CONDITIONS
IF = 5 A
IF = 10 A
Instantaneous forward voltage
IF = 5 A
IF = 10 A
VR = 45 V
Reverse current
SYMBOL
TA = 25 °C
VF (1)
TA = 125 °C
TA = 25 °C
TYP.
MAX.
0.43
-
0.49
0.57
0.33
-
V
0.41
0.52
-
1700
μA
16
41
mA
IR (2)
TA = 125 °C
UNIT
Notes
(1) Pulse test: 300 μs pulse width, 1 % duty cycle
(2) Pulse test: Pulse width  5 ms
THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
Typical thermal resistance
SYMBOL
V10WL45
RJC
1.8
RJA (1)(2)
65
UNIT
°C/W
Notes
(1) The heat generated must be less than the thermal conductivity from junction-to-ambient: dP /dT < 1/R
D
J
JA
(2) Free air, without heatsink
ORDERING INFORMATION (Example)
PREFERRED P/N
UNIT WEIGHT (g)
PACKAGE CODE
BASE QUANTITY
DELIVERY MODE
0.38
I
2500/reel
13" diameter plastic tape and reel
V10WL45-M3/I
6
12
D = 0.5
RthJA = RthJC = 1.8 °C/W
Average Power Loss (W)
Average Forward Rectified Current (A)
RATINGS AND CHARACTERISTICS CURVES (TA = 25 °C unless otherwise noted)
10
8
RthJA = 65 °C/W
6
4
2
D = 0.8
D = 0.3
5
D = 0.2
4
D = 0.1
D = 1.0
3
T
2
1
D = tp/T
tp
0
0
0
25
50
75
100
125
Case Temperature ( °C)
Fig. 1 - Forward Current Derating Curve
150
0
1
2
3
4
5
6
7
8
9
10 11 12
Average Forward Current (A)
Fig. 2 - Forward Power Loss Characteristics
Revision: 04-Dec-13
Document Number: 89970
2
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
V10WL45-M3
Vishay General Semiconductor
10 000
100
Junction Capacitance (pF)
Instantaneous Forward Current (A)
www.vishay.com
TA = 150 °C
10
TA = 125 °C
TA = 100 °C
1
TA = 25 °C
TJ = 25 °C
f = 1.0 MHz
Vsig = 50 mVp-p
1000
100
0.1
0
0.1
0.2
0.3
0.4
0.5
0.6
0.1
0.7
1
Reverse Voltage (V)
Instantaneous Forward Voltage (V)
TA = 150 °C
TA = 125 °C
10
TA = 100 °C
1
0.1
TA = 25 °C
0.01
0.001
20
30
40
50
60
70
80
90
Percent of Rated Peak Reverse Voltage (%)
Fig. 4 - Typical Reverse Characteristics
100
Fig. 5 - Typical Junction Capacitance
Transient Thermal Impedance (°C/W)
Instantaneous Reverse Current (mA)
Fig. 3 - Typical Instantaneous Forward Characteristics
100
10
10
Junction to Case
1
0.1
0.01
0.1
1
10
100
t - Pulse Duration (s)
Fig. 6 - Typical Transient Thermal Impedance
Revision: 04-Dec-13
Document Number: 89970
3
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
V10WL45-M3
www.vishay.com
Vishay General Semiconductor
PACKAGE OUTLINE DIMENSIONS in inches (millimeters)
TO-252 (D-PAK)
A
E
Mounting Pad Layout
in inches (millimeters)
0.002"
c
-A-
0.244 MIN.
(6.2)
0.05 mm
b3
L3
1.55 mm REF.
0.256
(6.5) MIN.
D
H
A1
L4
b2
0.39 (9.9)
0.488 (12.4)
b
e
See detail A
0.094 MIN.
(2.4)
c
0.051 MIN.
(1.3)
0.086 (2.19)
0.094 (2.39)
L2
D1
E1
θ
L
0.004"
0.1 mm
SYMBOL
INCHES
MILLIMETERS
MIN.
MAX.
MIN.
MAX.
A
0.086
0.094
2.19
2.38
A1
-
0.005
-
0.13
b
0.025
0.035
0.64
0.89
b2
0.033
0.045
0.84
1.14
b3
0.205
0.215
5.21
5.46
c
0.018
0.024
0.46
0.61
D
0.235
0.250
5.97
6.22
D1
0.205
-
5.21
-
E
0.250
0.265
6.35
6.73
E1
0.190
-
4.83
-
e
0.090 BSC.
2.29 BSC.
H
0.380
0.410
9.65
10.41
L
0.055
0.070
1.40
1.78
L2
0.020 BSC.
0.51 BSC.
L3
0.035
0.050
0.89
1.27
L4
0.025
0.039
0.64
1.01

0°
8°
0°
8°
Note
• Conforms to JEDEC TO-252 variation AA except dimension “D”
Revision: 04-Dec-13
Document Number: 89970
4
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1
Document Number: 91000