POLYFUSE® RESETTABLE FUSES VTD Strap Type, 16 V Specifications Standard Packaging A small pack D standard Materials Insulating material: Polyester Tape Terminals: Nickel Max. Device Surface Temperature in Tripped State 110 °C Operating / Storage Temperature -40 ºC to +85 ºC (consider derating) Humidity Ageing +60 °C, 95 % R.H., 1000 hours, ± 10 % typical resistance change Vibration MIL-STD-883C, Condition A, no change Thermal Shock MIL-STD-202F, Method 107G +85 °C to -40 °C 10 times ±5 % typical resistance change Marking “P”, Part Code, identification, lot number UL 1434 1st Edition CSA C22.2 No. 0 CSA TIL No. CA-3A Approvals cULus Recognition TÜV Features The new VTD product series feature a slim, low profile and low resistance design. These devices are ideal to be installed directly onto the latest generation batteries including cylindrical and prismatic cells. The VTD product offers protection against both overcurrent and overtemperature fault conditions. Dimensions (mm) S: one slot SS: two slots Dimensions (mm) Model A Min Max Fig VTD170 VTD170XS VTD175 VTD175S VTD175L VTD175XL VTD200 VTD200S VTD210 VTD210S VTD210SS VTD210L VTD210LS VTD240 1 2 1 2 1 4 1 2 1 2 3 1 2 1 15.4 20.9 20.9 20.9 26.0 25.5 20.9 20.9 20.9 20.9 20.9 24.0 24.0 24.2 B Min Max 17.5 22.9 22.2 22.2 28.0 28.2 23.1 23.1 23.1 23.1 23.1 26.0 26.0 26.2 7.0 4.9 3.5 3.5 3.5 3.5 3.8 3.8 4.9 4.9 4.9 4.9 4.9 4.9 C Min Max 7.4 5.3 3.8 3.8 3.8 3.9 4.3 4.3 5.3 5.3 5.3 5.3 5.3 5.3 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 D Min 0.8 0.8 0.7 0.7 0.8 0.8 0.7 0.7 0.8 0.8 0.8 0.8 0.8 0.8 4.0 4.0 4.0 4.0 6.5 8.7 4.0 4.0 4.1 4.1 4.1 5.0 5.0 5.0 E F Min Max Min 3.9 3.9 2.9 2.9 2.9 2.4 2.9 2.9 3.9 3.9 3.9 3.9 3.9 3.9 4.1 4.1 3.1 3.1 3.1 2.6 3.1 3.1 4.1 4.1 4.1 4.1 4.1 4.1 5.7 packaging quantity small pack standard 500 500 500 500 500 500 500 500 500 500 500 500 500 500 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 Permissible continuous operating current is ≤ 100 % at ambient temperature of 20 ºC (68 ºF). NOTE: I hold = I trip = Vmax = I max = Vmax. dc (V) Imax. (A) max. time to trip (s @ A) Pd max. (W) R min.( ) 3.40 3.40 3.80 3.80 3.80 3.80 4.50 4.50 4.70 4.70 4.70 4.70 4.70 5.40 15 15 15 15 15 15 15 15 15 15 15 15 15 15 100 100 100 100 100 100 100 100 100 100 100 100 100 100 3.0 @ 8.5 3.0 @ 8.5 3.0 @ 8.5 3.0 @ 9.0 3.0 @ 9.0 5.0 @ 8.75 4.0 @ 10.0 4.0 @ 10.0 5.0 @ 10.0 5.0 @ 10.0 5.0 @ 10.0 5.0 @ 10.0 5.0 @ 10.0 4.0 @ 12.0 1.40 1.40 1.40 1.40 1.40 1.40 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 0.030 0.030 0.025 0.025 0.025 0.029 0.021 0.021 0.018 0.018 0.018 0.018 0.018 0.015 Hold current: maximum current device will pass without tripping in 20 °C still air. Trip current: minimum current at which the device will trip in 20 °C still air. Maximum voltage device can withstand without damage at rated current (I max) Maximum fault current device can withstand without damage at rated voltage (Vmax) Order Information 041006 1.70 1.70 1.75 1.75 1.75 1.75 2.00 2.00 2.10 2.10 2.10 2.10 2.10 2.40 ITrip (A) Qty. OrderNumber Model Resistance Approvals R max.( ) RI max.( ) 0.052 0.052 0.045 0.045 0.045 0.051 0.039 0.039 0.030 0.030 0.030 0.030 0.030 0.026 0.105 0.105 0.045 0.090 0.090 0.102 0.080 0.080 0.060 0.060 0.060 0.060 0.060 0.052 TÜV VTD170 VTD170XS VTD175 VTD175S VTD175L VTD175XL VTD200 VTD200 VTD210 VTD210S VTD210SS VTD210L VTD210LS VTD240 Ihold (A) cURus Model • • • • • • • • • • • • • • • • • • • • • • • • • • • • Pd = Power dissipated from device when in the tripped state at 20 °C still air. Minimum resistance of device in initial (un-soldered) state. R min= Maximum resistance of device at 20 °C measured one hour after tripping for 20 s. R 1max= Caution: Operation beyond the specified rating may result in damage and possible arcing and flame. Specifications are subject to change without notice Packaging In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com POLYFUSE® RESETTABLE FUSES VTD AB A: VTD170 B: VTD210 100.00 Time-to-Trip (s) 10.00 1.00 0.10 0.01 1.00 10.00 100.00 Fault Current (A) Further Time-Current-Curves on request Thermal Derating Chart Model VTD170 VTD170XS VTD175 VTD175S VTD175L VTD175XL VTD200 VTD200S VTD210 VTD210S VTD210SS VTD210L VTD210LS VTD240 041006 Ambient Operation Temperature - Ihold (A) -40 °C -20 °C 0 °C 23 °C 40 °C 50 °C 60 °C 70 °C 85 °C 3.20 3.20 3.20 3.20 3.20 3.20 3.70 3.70 4.10 4.10 4.10 4.10 4.10 4.40 2.70 2.70 2.70 2.70 2.70 2.70 3.20 3.20 3.50 3.50 3.50 3.50 3.50 3.70 2.20 2.20 2.20 2.20 2.20 2.20 2.60 2.60 2.90 2.90 2.90 2.90 2.90 3.10 1.70 1.70 1.75 1.75 1.75 1.75 2.00 2.00 2.10 2.10 2.10 2.10 2.10 2.40 1.30 1.30 1.30 1.30 1.30 1.30 1.50 1.50 1.60 1.60 1.60 1.60 1.60 1.80 1.00 1.00 1.00 1.00 1.00 1.00 1.20 1.20 1.30 1.30 1.30 1.30 1.30 1.50 0.80 0.80 0.80 0.80 0.80 0.80 0.90 0.90 1.00 1.00 1.00 1.00 1.00 1.20 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.70 0.70 0.70 0.70 0.70 0.90 0.10 0.10 0.10 0.10 0.10 0.10 0.10 0.10 0.10 0.10 0.10 0.10 0.10 0.10 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com