LITTELFUSE VTD210L

POLYFUSE® RESETTABLE FUSES
VTD
Strap Type, 16 V
Specifications
Standard
Packaging
A
small pack
D
standard
Materials
Insulating material: Polyester Tape
Terminals:
Nickel
Max. Device Surface Temperature in Tripped State
110 °C
Operating / Storage Temperature
-40 ºC to +85 ºC (consider derating)
Humidity Ageing
+60 °C, 95 % R.H., 1000 hours, ± 10 % typical
resistance change
Vibration
MIL-STD-883C, Condition A, no change
Thermal Shock
MIL-STD-202F, Method 107G
+85 °C to -40 °C 10 times ±5 % typical resistance
change
Marking
“P”, Part Code, identification, lot number
UL 1434 1st Edition
CSA C22.2 No. 0 CSA TIL No. CA-3A
Approvals
cULus Recognition
TÜV
Features
The new VTD product series feature a slim, low
profile and low resistance design. These devices
are ideal to be installed directly onto the latest
generation batteries including cylindrical and
prismatic cells. The VTD product offers protection against both overcurrent and overtemperature fault conditions.
Dimensions (mm)
S: one slot
SS: two slots
Dimensions (mm)
Model
A
Min Max
Fig
VTD170
VTD170XS
VTD175
VTD175S
VTD175L
VTD175XL
VTD200
VTD200S
VTD210
VTD210S
VTD210SS
VTD210L
VTD210LS
VTD240
1
2
1
2
1
4
1
2
1
2
3
1
2
1
15.4
20.9
20.9
20.9
26.0
25.5
20.9
20.9
20.9
20.9
20.9
24.0
24.0
24.2
B
Min Max
17.5
22.9
22.2
22.2
28.0
28.2
23.1
23.1
23.1
23.1
23.1
26.0
26.0
26.2
7.0
4.9
3.5
3.5
3.5
3.5
3.8
3.8
4.9
4.9
4.9
4.9
4.9
4.9
C
Min Max
7.4
5.3
3.8
3.8
3.8
3.9
4.3
4.3
5.3
5.3
5.3
5.3
5.3
5.3
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
D
Min
0.8
0.8
0.7
0.7
0.8
0.8
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
4.0
4.0
4.0
4.0
6.5
8.7
4.0
4.0
4.1
4.1
4.1
5.0
5.0
5.0
E
F
Min Max Min
3.9
3.9
2.9
2.9
2.9
2.4
2.9
2.9
3.9
3.9
3.9
3.9
3.9
3.9
4.1
4.1
3.1
3.1
3.1
2.6
3.1
3.1
4.1
4.1
4.1
4.1
4.1
4.1
5.7
packaging quantity
small pack standard
500
500
500
500
500
500
500
500
500
500
500
500
500
500
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
Permissible continuous operating current is ≤ 100 % at ambient temperature of 20 ºC (68 ºF).
NOTE:
I hold =
I trip =
Vmax =
I max =
Vmax. dc
(V)
Imax.
(A)
max. time to trip
(s @ A)
Pd max.
(W)
R min.( )
3.40
3.40
3.80
3.80
3.80
3.80
4.50
4.50
4.70
4.70
4.70
4.70
4.70
5.40
15
15
15
15
15
15
15
15
15
15
15
15
15
15
100
100
100
100
100
100
100
100
100
100
100
100
100
100
3.0 @ 8.5
3.0 @ 8.5
3.0 @ 8.5
3.0 @ 9.0
3.0 @ 9.0
5.0 @ 8.75
4.0 @ 10.0
4.0 @ 10.0
5.0 @ 10.0
5.0 @ 10.0
5.0 @ 10.0
5.0 @ 10.0
5.0 @ 10.0
4.0 @ 12.0
1.40
1.40
1.40
1.40
1.40
1.40
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
0.030
0.030
0.025
0.025
0.025
0.029
0.021
0.021
0.018
0.018
0.018
0.018
0.018
0.015
Hold current: maximum current device will pass without tripping in 20 °C still air.
Trip current: minimum current at which the device will trip in 20 °C still air.
Maximum voltage device can withstand without damage at rated current (I max)
Maximum fault current device can withstand without damage at rated voltage (Vmax)
Order
Information
041006
1.70
1.70
1.75
1.75
1.75
1.75
2.00
2.00
2.10
2.10
2.10
2.10
2.10
2.40
ITrip
(A)
Qty.
OrderNumber
Model
Resistance
Approvals
R max.( ) RI max.( )
0.052
0.052
0.045
0.045
0.045
0.051
0.039
0.039
0.030
0.030
0.030
0.030
0.030
0.026
0.105
0.105
0.045
0.090
0.090
0.102
0.080
0.080
0.060
0.060
0.060
0.060
0.060
0.052
TÜV
VTD170
VTD170XS
VTD175
VTD175S
VTD175L
VTD175XL
VTD200
VTD200
VTD210
VTD210S
VTD210SS
VTD210L
VTD210LS
VTD240
Ihold
(A)
cURus
Model
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Pd =
Power dissipated from device when in the tripped state at 20 °C still air.
Minimum resistance of device in initial (un-soldered) state.
R min=
Maximum resistance of device at 20 °C measured one hour after tripping for 20 s.
R 1max=
Caution: Operation beyond the specified rating may result in damage and possible arcing and flame.
Specifications are subject to change without notice
Packaging
In our continuing strategy to deliver unparalleled circuit protection solutions,
technical expertise and application leadership, we proudly introduce the
WICKMANN Group and its products to the Littelfuse portfolio.
www.littelfuse.com
POLYFUSE® RESETTABLE FUSES
VTD
AB
A: VTD170
B: VTD210
100.00
Time-to-Trip (s)
10.00
1.00
0.10
0.01
1.00
10.00
100.00
Fault Current (A)
Further Time-Current-Curves on request
Thermal Derating Chart
Model
VTD170
VTD170XS
VTD175
VTD175S
VTD175L
VTD175XL
VTD200
VTD200S
VTD210
VTD210S
VTD210SS
VTD210L
VTD210LS
VTD240
041006
Ambient Operation Temperature - Ihold (A)
-40 °C
-20 °C
0 °C
23 °C
40 °C
50 °C
60 °C
70 °C
85 °C
3.20
3.20
3.20
3.20
3.20
3.20
3.70
3.70
4.10
4.10
4.10
4.10
4.10
4.40
2.70
2.70
2.70
2.70
2.70
2.70
3.20
3.20
3.50
3.50
3.50
3.50
3.50
3.70
2.20
2.20
2.20
2.20
2.20
2.20
2.60
2.60
2.90
2.90
2.90
2.90
2.90
3.10
1.70
1.70
1.75
1.75
1.75
1.75
2.00
2.00
2.10
2.10
2.10
2.10
2.10
2.40
1.30
1.30
1.30
1.30
1.30
1.30
1.50
1.50
1.60
1.60
1.60
1.60
1.60
1.80
1.00
1.00
1.00
1.00
1.00
1.00
1.20
1.20
1.30
1.30
1.30
1.30
1.30
1.50
0.80
0.80
0.80
0.80
0.80
0.80
0.90
0.90
1.00
1.00
1.00
1.00
1.00
1.20
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.70
0.70
0.70
0.70
0.70
0.90
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
In our continuing strategy to deliver unparalleled circuit protection solutions,
technical expertise and application leadership, we proudly introduce the
WICKMANN Group and its products to the Littelfuse portfolio.
www.littelfuse.com