INFINEON KP21X

Product Brief
KP21x/MAP
Integrated Pressure Sensor IC
for Manifold Air Pressure Measurement
Applications
Application
The manifold air pressure (MAP) is an important parameter to compute the airfuel ratio provided to the engine for lower emission due to better combustion
and increased efficiency. For cost sensitive engine systems a MAP sensor show
the potential to complement or even substitute mass air flow (MAF) sensors. In
addition manifold pressure data can be used to compute diagnostics of leakages
and malfunctions of the exhaust gas recirculation valve. In automotive applications
where high production volumes are common there is substantial interest in
precision, low-cost and fully integrated sensors. In this context products of the
developed MAP sensor family KP21x are the optimum solution for aspirated or turbo
diesel and gasoline engines management systems.
Typical Application
 Engine control/MAP applications
 Industrial controls
Features
 Absolute air pressure measurement
 Excellent accuracy of up to 1.0 kPa over a large temperature range
 Ratiometric analog output
 Output signal fully compensated
 Pressure range from 15 to 150 kPa
 Temperature range (ambient) from -40 to +140°C
 SMD package (PG-DSOF-8-16)
 Output clamping (optional for KP216)
 Complete Product Family (KP214, KP215, KP216)
Application Circuit for the Pressure Sensor System
5V
1
Test
KP21x
2 CLOCK/
VPROG
3
DATA IN
4
DATA OUT
VDD
GND
VOUT
GND
T-Sensor
MAP module
www.infineon.com/sensors
Sensors
5
6
7
8
Ref
C1
C2
R1*)
R3
R2*)
ADC
A/D IN
C3
Microcontroller
A/D IN
GND
*) R1 and R2 only alternatively
Electronic control unit (ECU)
Product Brief
Highly Integrated Sensors - Single Chip
VDD
CLOCK/VPROG
Internal
Reference
Voltage
EEPROM
(90 + 22 bits)
Temperature
Compensation
Digital Control
A
D
1 bit
1 kHz
12 bit
DATA IN
DATA OUT
Test and Programming
Interface
10 bit Optional 10 bit
D
Linearization
A
Clamping
30 kHz
VOUT
VDD
Clock
Generator
OBD
GND
Infineon offers an extensive broad product portfolio for diesel engine management systems from micro-machined sensors to smart
power ICs and microcontrollers. The KP21x pressure sensor as an integrated pressure sensor for manifold pressure measurement,
is a benchmark in terms of reliability, performance and integration level.
Product Summary
Parameter
Range
Min.
Unit
Typ.
Accuracy
Max.
1.0
% F.S.
Pressure Range
10
150
kPa
Sensitivity
40
88
mV/kPa
Supply Voltage
4.5
5.5
V
1.0
mA
5.0
Output Current
Output Voltage
0.1
4.85
V
Operating Temperature
-40
+140
°C
Transfer Function Pressure Min
15
60
kPa
Transfer Function Pressure Max
100
150
kPa
Transfer Function Voltage Min
0.1
0.5
V
Transfer Function Voltage Max
4.5
4.85
V
Lower Programmable Clamping Level (KP226)
0.0
0.63
V
Upper Programmable Clamping Level (KP226)
4.37
5.0
V
Programmable Transfer Functions
How to reach us:
http://www.infineon.com
Published by
Infineon Technologies AG
81726 Munich, Germany
© 2008 Infineon Technologies AG
All Rights Reserved.
Legal Disclaimer
The information given in this Product Brief shall in no event be
regarded as a guarantee of conditions or characteristics. With
respect to any examples or hints given herein, any typical values
stated herein and/or any information regarding the application of
the device, Infineon Technologies hereby disclaims any and all
warranties and liabilities of any kind, including without limitation,
warranties of non-infringement of intellectual property rights of
any third party.
Information
For further information on technology, delivery terms and
conditions and prices, please contact the nearest
Infineon Technologies Office (www.infineon.com).
Published by Infineon Technologies AG
Warnings
Due to technical requirements, components may contain
dangerous substances. For information on the types in question,
please contact the nearest Infineon Technologies Office.
Infineon Technologies components may be used in life-support
devices or systems only with the express written approval of
Infineon Technologies, if a failure of such components can
reasonably be expected to cause the failure of that life-support
device or system or to affect the safety or effectiveness of that
device or system. Life support devices or systems are intended
to be implanted in the human body or to support and/or maintain and sustain and/or protect human life. If they fail, it is
reasonable to assume that the health of the user or other
persons may be endangered.
Ordering No. B142-H9193-X-X-7600