PoE Consortium Clause # 33 Parametric Report

Power Over Ethernet Consortium
Clause 33 PD Parametric Test Suite Version 1.3
InterOperability Lab — 121 Technology Drive, Suite 2
Durham, NH 03824 — (603) 862-0230
Consortium Manager:
Technician:
Gerard Nadeau
Jeremy Kent
[email protected]
[email protected]
August 18, 2003
Dave Dwelley
Linear Technology Corp
1630 McCarthy Blvd
Milpitas, CA 95035
Mr. Dwelley,
Enclosed are the results from the Clause 33 PD Parametric Test Suite performed on:
Linear Technology LTC 42571S8 485A Evaluation Board
This testing pertains to a set of standard requirements, put forth in the Clause 33 of IEEE Std. 802.3af, 2003 Edition.
The tests performed are part of the Clause 33 PD Parametric Test Suite, which is available on the UNH
InterOperability Lab’s website:
ftp://ftp.iol.unh.edu/pub/poe/PoE_PD_Parametric_test_suite.pdf
There were no issues uncovered during the testing process.
As always, we welcome any comments regarding this test suite. If you have any questions or comments about test
procedures or results, please feel free to contact me via e-mail at [email protected] or by phone at (603) 862-4196.
Regards,
Jeremy Kent
The following table contains possible results and their meanings.
Result
PASS
FAIL
PASS with
Comments
Warning
Refer to
Comments
Not Appl icable
Not Available
Not Tested
Borderline
Informative
Interpretation
The DUT was observed to exhibit conformant behavior.
The DUT was observed to exhibit non-compliant behavior.
The DUT was observed to exhibit conformant behavior, however this behavior deviated from
previous compliant results. An additional explanation of the situation is included.
The DUT was observed to exhibit behavior that is not recommended.
From the observations, a valid pass or fail could not be determined. An additional
explanation of the situation is included.
The DUT does not support the technology required to perform these tests.
Due to testing station or time limitations, the tests could not be performed, or were performed
in a limited capacity.
Not tested due to time constraint of the test period.
The observed values of the parameter is valid at one extreme, and invalid at
the other extreme.
Results are for informative purposes only and are not judged on a pass or fail basis.
Clause 33 PD Parametric Test Suite
DUT: Linear Technology LTC 42571S8 485A Evaluation Board
GROUP 1: PARAMETRIC TESTING
Test #
33.1.1
PD Source Power
Comments on Test Procedure
Test Label
a
Result
PASS
Purpose: To verify that the DUT does not source power on its PI.
a.
The DUT should not source power on its PI at any time.
Comments on Test Results
a.
The DUT was observed to not source power on either of its two sets of PI conductors.
Test #
33.1.2
Test Label
PD Pinout
a
b
Result
PASS
Not
Available
Comments on Test Procedure
Purpose: To verify that the DUT is insensitive to the polarity of the power supply and is able to operate in either
Mode A or Mode B.
a.
b.
In all cases the DUT should accept the applied power and become operational once the requested power has
been supplied.
The DUT should not accept power on Mode A and Mode B simultaneously.
Comments on Test Results
a.
b.
The DUT became operational when power was applied to Mode A (MDI and MDI-X), or Mode B (MDI and
MDI-X).
Due to testing station limitations this test could not be performed.
Power Over Ethernet Consortium Test Suite
1
Clause 33 PD Parametric Report
Version 1.2
Clause 33 PD Parametric Test Suite
DUT: Linear Technology LTC 42571S8 485A Evaluation Board
Test #
33.1.3
Test Label
Valid PD Detection Signature Characteristics
a
b
c
d
Result
PASS
PASS
Not
Available
Not
Available
Comments on Test Procedure
Purpose: To verify that the DUT presents a valid detection signature while it is requesting power on the PI.
a.
b.
c.
d.
The observed signature resistance should between 23.75 and 26.25 kΩ (inclusive).
The DUT should have either a voltage offset less than of equal to 1.9 V, or a current offset less than or equal to
10 µA.
The DUT should have a signature capacitance between 0.05 and 0.12 µF (inclusive).
The observed signature inductance should be less than or equal to 100 µH.
Comments on Test Results
a.
b.
c.
d.
Mode A – 24.44 kΩ ≤ Rsig ≤ 25.28 kΩ
Mode B – 24.45 kΩ ≤ Rsig ≤ 25.28 kΩ
Refer to the signature resistance plots on the following pages for further information regarding this test.
Mode A - Voffset ≤ 1.03 V
Mode B - Voffset ≤ 1.03 V
Due to testing station limitations this test could not be performed.
Due to testing station limitations this test could not be performed.
Power Over Ethernet Consortium Test Suite
2
Clause 33 PD Parametric Report
Version 1.2
−4
6
PD Signature V−I Curve - Mode A
x 10
Current − mA
5
4
3
2
1
0
0
1
2
3
4
5
Voltage − V
6
7
8
9
10
8
9
10
Resistance − kOhms
PD Signature R Curve - Mode A
30
25
20
15
0
1
2
3
4
5
Voltage − V
6
7
−4
6
PD Signature V−I Curve - Mode B
x 10
Current − mA
5
4
3
2
1
0
0
1
2
3
4
5
Voltage − V
6
7
8
9
10
8
9
10
Resistance − kOhms
PD Signature R Curve - Mode B
30
25
20
15
0
1
2
3
4
5
Voltage − V
6
7
Clause 33 PD Parametric Test Suite
DUT: Linear Technology LTC 42571S8 485A Evaluation Board
Test #
33.1.4
Test Label
Non-Valid PD Detection Signature Characteristics
a
b
Result
PASS
Not
Available
Comments on Test Procedure
Purpose: To verify that the DUT presents a non-valid detection signature while it is not requesting power, or once
powered, at the PI of the non-powered pairs.
a.
b.
The PD should have a non-valid input resistance less than 12 kΩ or greater than 45 kΩ.
The PD should have an input capacitance of less than 10µF.
Comments on Test Results
a.
b.
The DUT properly displayed an invalid detection signature when it was not requesting power.
Due to testing station limitations this test could not be performed.
Test #
33.1.5
Test Label
PD Classification Characteristics
a
b
Result
PASS
PASS
Comments on Test Procedure
Purpose: To verify that the DUT provides proper information about its maximum power requirements, and that those
require ments fall within the acceptable range.
a.
b.
The current drawn by the DUT should fall within the range (inclusive) specified for each supported class.
The power drawn by the DUT should fall within the range (inclusive) specified for each supported class.
Comments on Test Results
a.
b.
The DUT was observed to present the appropriate classification signature for both Mode A and Mode B. Refer
to the classification plots on the following pages for further information regarding this test.
Mode A – 0.83 W ≤ Pport ≤ 0.91 W
Mode B – 0.83 W ≤ Pport ≤ 0.91 W
Power Over Ethernet Consortium Test Suite
3
Clause 33 PD Parametric Report
Version 1.2
Classification Current Draw - Mode A
Class: 0
0.6
0.55
Current (mA)
0.5
0.45
0.4
0.35
0.3
14
15
16
17
18
Voltage (V)
19
20
21
Classification Current Draw - Mode B
Class: 0
0.65
0.6
Current (mA)
0.55
0.5
0.45
0.4
0.35
0.3
14
15
16
17
18
Voltage (V)
19
20
21
Classification Current Draw - Mode A
Class: 1
10.65
10.6
Current (mA)
10.55
10.5
10.45
10.4
10.35
10.3
14
15
16
17
18
Voltage (V)
19
20
21
Classification Current Draw - Mode B
Class: 1
10.65
10.6
Current (mA)
10.55
10.5
10.45
10.4
10.35
10.3
14
15
16
17
18
Voltage (V)
19
20
21
Classification Current Draw - Mode A
Class: 2
18.8
18.75
18.7
Current (mA)
18.65
18.6
18.55
18.5
18.45
18.4
14
15
16
17
18
Voltage (V)
19
20
21
Classification Current Draw - Mode B
Class: 2
18.8
18.75
18.7
Current (mA)
18.65
18.6
18.55
18.5
18.45
18.4
14
15
16
17
18
Voltage (V)
19
20
21
Classification Current Draw - Mode A
Class: 3
27.9
27.85
27.8
Current (mA)
27.75
27.7
27.65
27.6
27.55
27.5
14
15
16
17
18
Voltage (V)
19
20
21
Classification Current Draw - Mode B
Class: 3
27.9
27.85
27.8
Current (mA)
27.75
27.7
27.65
27.6
27.55
27.5
14
15
16
17
18
Voltage (V)
19
20
21
Classification Current Draw - Mode A
Class: 4
40.6
40.55
40.5
Current (mA)
40.45
40.4
40.35
40.3
40.25
40.2
14
15
16
17
18
Voltage (V)
19
20
21
Classification Current Draw - Mode B
Class: 4
40.6
40.55
40.5
Current (mA)
40.45
40.4
40.35
40.3
40.25
40.2
14
15
16
17
18
Voltage (V)
19
20
21
Clause 33 PD Parametric Test Suite
DUT: Linear Technology LTC 42571S8 485A Evaluation Board
Test #
33.1.6
Test Label
PD Power Supply Turn On / Off
a
b
c
Result
Not
Applicable
Not
Applicable
Not
Applicable
Comments on Test Procedure
Purpose: To verify that the DUT will turn on once power has been applied to the PI, will remain on over the entire
port voltage range, and turn off once power is removed.
a.
b.
c.
The DUT should become fully operational at a port voltage less than 42 V.
Once the DUT has turned on, it should remain operational for port voltages between 44 V and 57 V.
The DUT should turn off at a port voltage greater than 30V and less than 36 V.
Comments on Test Results
The DUT was an evaluation board, and there were no means to determine when the DUT became operational;
therefore this test did not apply.
Power Over Ethernet Consortium Test Suite
4
Clause 33 PD Parametric Report
Version 1.2