Precision Cooling for Business-Critical Continuity™ Liebert HPC-M The Data Center FreeCooling Chiller with the Lowest Impact on the Environment Emerson Network Power, a division of Emerson Electric Co., is a global company that combines technology with design to supply innovative solutions for the benefit of its customers. Emerson Network Power is the leader in the “business-critical continuity” field, thanks to the company’s products and services. Emerson Network Power’s broad technology base and global expertise supports a full spectrum of enterprise-wide solutions for today’s vital business needs. Regardless of your size, you can’t afford for your critical business systems to go down and you can’t waste time recovering your IT infrastructure after a disruption. Leave that to us, the experts in business-critical continuity: from grid to chip, from the biggest to the smallest data centers, we are ready to serve your needs with the solutions we have developed. 2 More standardization, so you don’t need further budget allocations to install it. More simplification so you don’t need to be a specialist to get the best for your business. More support, so while you are enjoying doing business, we are protecting you. That’s why we can say we OptimizeIT! Emerson Network Power Liebert HPC Chiller in conjunction with the SmartAisleTM to deliver the lowest operating costs. 3 Liebert HPC-M: When Reliability and High Efficiency Count. Cooling data centers or other Liebert HPC-M is the new Emerson Network Power product line of air-cooled chillers, from 350 to 800 kW, designed to combine the best performance in terms of efficiency and reliability with the lowest impact on the environment. technological installations requires units designed to be reliable. Reliability enables high system availability. With Liebert HPC-M we have added efficiency to the equation as this strongly impacts on the operating costs of the data center. With Liebert HPC Emerson Network Power has introduced to the market a product able to extend its operating conditions to a wider range of water temperatures. In fact, data center applications may require variable cooling capacity during the day involving a water temperature much higher than the 7-12° C that a conventional chiller delivers. These performances can be 4 obtained when the entire system is setup to work in a SmartAisleTM configuration where the floor mounted or in the row cooling units can interact with the chiller, thanks to the iCOM control, providing the best performances with the lowest energy consumption. Liebert HPM Extended Indoor Room Cooling chilled water units from 30 to 200 kW. • Up to 50% increased efficiency • Designed for SmartAisle applications • Optimized for maximizing freecooling chiller efficiency SmartAisleTM • Aisle containment • Provides highest energy efficiency • Works with any Liebert Cooling Unit Liebert HPC Wide range of high- efficiency freecooling chillers from 40 kW to 1600 kW • Designed specifically for data center applications and to work with SmartAisleTM • Premium energy efficiency version • iCOM control featured Liebert XD Refrigerant based high density cooling installed close to the server • Hot spot management for up to 30 kW per rack • On-demand upgrade with plug and play • High efficiency and 100% sensible cooling Liebert CRV Row-based high efficiency precision cooling units available in DX or CW versions • Decoupled control for airflow and cooling capacity • Modulating cooling capacity with digital scroll • iCOM control with remote rack sensors TrellisTM Solutions Liebert HPC is ready to be integral to the benefits of the TrellisTM platform. TrellisTM is the first integrated, single information-source data center infrastructure management (DCIM) platform. It brings together IT equipment and facilities infrastructure and allows data center managers to make smarter decisions on the interplay between efficiency, availability and capacity utilization of the entire infrastructure and in particular of Liebert HPC chillers, Liebert HPM floor mounted units and of the overall Emerson Network Power Precision cooling system. 5 Liebert HPC-M: Drive Down the CO2 Emission with the Data Center FreeCooling Chiller. Liebert HPC-M (300-800kW) Best Goals Are: Maximized energy efficiency thanks to: •New compressor design optimized to guarantee high efficiency especially in partial load •Evaporators: a new advanced DX evaporator optimized for R134a, with counter current configuration. -PHE (frame with 6-8 fans) -Shell & Tube (frame with 10-12 fans) •EEV (Electronic Expansion Valve): stability and efficiency guaranteed in all conditions EC Fans: High efficiency motors guarantee energy consumption 25% less than traditional AC motors. Lower sound emission, without any electromagnetic noise. Adapt Your Chiller to the Environment, and Protect IT. Liebert HPC-M efficiency is at its greatest when it comes to the 6 “G” version. Designed for extreme external conditions, like tropical temperatures found in the Middle East, this model contains technologies that bring the highest efficiency. For this reason, it is not only suitable for the environments already mentioned, but also for a wider operating range, including various industrial applications, where the required water temperature is higher than the conventional operating conditions of a standard chiller. The Fast Start Ramp: Never-Ending Availability. The Fast Start Ramp is the innovative technology that in the case of any emergency, like a power failure, restores the optimal operation of the chiller. Liebert HPC-M 100% capacity is available in 40 seconds, avoiding any unacceptable increase in water temperature. Your business continuity is safe. Main Components •Air cooled screw chiller •Chiller & Free-cooling versions •R134a •2 screw compressors •2 independent refrigerant circuits •Step less capacity control •EEV •29 sizes •Compact design •EC Fans •Extremely low noise •High Efficiency •Wider Operating Range Liebert HPC-M is the chiller voted of maximum efficiency, equipped with those techonologies that provide the best performance having the environment in mind. 40000 Energy cons.[kWh] 35000 30000 25000 20000 15000 10000 5000 40000 Energy cons.[kWh] 35000 30000 25000 20000 15000 Frankfurt profile Load 500kW Chiller/Fluid T: 15-10°C -32% FG4052/Fluid T: 15-10°C -29% -60 % FG4046/Fluid T: 21-15°C -20% FG4039/Fluid T 24-18°C 5000 -20 -10 0 T[°C] FG4052/Fluid T: 15-10°C -29% -60 % FG4046/Fluid T: 21-15°C -20% FG4039/Fluid T 24-18°C SCREW COMPRESSOR Liebert HPC-M is equipped with screw compressors to improve efficiency and reliability of performance. -20 -10 0 T[°C] FAST START RAMP Liebert HPC-M, always reliable. Fast Start Ramp ensures your chiller is restored to full capacity in only 40 seconds after a power failure. 10000 0 -30 0 -30 Chiller/Fluid T: 15-10°C -32% 10 20 30 40 HIGH EFFICIENCY Maximized efficiency, even when working in tropical regions. Up to 60% energy saving with the “G” version. Liebert HPC-M with SmartAisleTM compared with a conventional chiller installation. Start pump - check flow Power Failure 1° Compressor loading 2° Compressor loading iCOM under UPS power supply fast start routine 0’’ 20’’ 40’’ 60’’ EXTREMELY LOW NOISE A silent Chiller, thanks to the HyBlade EC Fans and special acoustic insulation for the greatest comfort iCOM Advanced unit and teamwork control to maximize energy efficiency. It operates at extreme ambient and water temperature conditions. FREE COOLING Integrated Freecooling section, to get additional energy saving and greater reliability. Liebert HPC M Fast Start Ramp routine. 7 10 Annual Energy Consumption [kWh] 70000 65000 60000 55000 50000 45000 40000 35000 30000 25000 20000 15000 10000 5000 0 Oslo Liebert HPC-M: Energy Saving and Freecooling from Athens to Oslo. -22 -20-18-16 -14 -12-10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 8 Annual Energy Consumption [kWh] 70000 65000 60000 55000 50000 45000 40000 35000 30000 25000 20000 15000 10000 5000 0 Athens Oslo Annual Energy Consumption [kWh] 70000 65000 60000 35000 55000 50000 30000 45000 25000 40000 20000 35000 15000 30000 25000 10000 20000 5000 15000 0 10000 -12-10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 3840 42 5000 0 Outdoor -22 -20-18-16 -14 -12 -10 -8 -6 -4Temperature -2 0 2 4 6 [°C] 8 10 12 14 16 18 20 22 24 26 28 45000 40000 Savings of more than 30% in energy use and up to 40k€ in your energy bill! Outdoor Temperature [°C] Oslo Annual energy consumption (Chiller) Annual energy consumption, plus free cooling module Athens Annual Energy Consumption [kWh] Precision Cooling Benefits for Data Center & Industrial Applications •Lower annual energy consumption •Reduced space requirements •Reduction of compressors’ working hours •Higher reliability •Safe operation at extremely low temperatures (e.g. -25/-30°C) 60000 55000 50000 60000 55000 50000 More than 60% in energy saving, so up to 70k€ saved in your energy bill! 45000 40000 35000 30000 25000 20000 15000 10000 5000 0 -22 -20-18-12 -16-10 -14-8-12 2 1241461681810 1224 142616 2236 243826 -6-10 -4 -8 -2 -6 0 2-44-26 08 10 20 22 2818 3020 32 34 4028 42 Outdoor Temperature Outdoor Temperature [°C][°C] Annual energy consumption (Chiller) Athensplus free cooling module Annual energy consumption, 60000 55000 50000conditions represent the saving for a 800 kW Liebert HPC, working in combination with The above Annual Energy Consumption [kWh] Integrated Freecooling section takes advantage of low outdoor air temperatures in the water cooling process by enabling compressor operation to be progressively reduced until being stopped, thereby saving energy. The strategies adopted by iCOM control the fan, compressor and regulation valve components, whilst operating modes, mechanical and/or free cooling, together with the compressors’ continuous modulation, ensure typical energy savings greater than 40% (in Northern and Central Europe). Annual Energy Consumption [kWh] Outdoor Temperature [°C] TM SmartAisle 45000 , where the required supply air temperature is 24°C. The Freecooling Chiller is considered in the40000 worst case of full load. A lower load would determine an higher unit efficiency, and therefore higher savings. Cost of the energy considered is of 0,1€/kWh 35000 30000 25000 20000 15000 10000 5000 0 Liebert HPC can be configured according to individual installation requirements, meeting our customers’ needs with flexibility. Liebert HPC-M: Features Standard options •Electronic expansion valve •Evaporator water flow switch •Part winding starting method •Double set point •Shifting set point •Auto unit Delta T setting •Advanced low condensing pressure control •Intelligent fans control based on external temperature or timeframe •Demand limit •Intelligent inrush current control •Remote on/off relay •Voltage free contact: - chiller/pump operation - compressors operation - general alarm - general warning - freecooling status (configurable) •EC Fans (on “G” and “Q” version) Additional options •Star delta starting method •Economizer •Pumps group on board Inverter pumps •Hydraulic kit •Double power supply and Fast Start Ramp •Compressor suction shut off valve •Evaporator-pipes-pumps trace heating •No-Glycol •Heat Recovery •Electrical panel heaters •Energy meter •Condensing coils filters •Protection grid •Compressors power factor correction •Anti vibration mount, rubber or spring [KIT] •BMS communication: ModBUS, BACnet, Lon Works, SNMP 9 Aircooled Screw Chiller HPC-M Range G Model (The Best Efficiency Model) Refrigerant R134a Cooling Capacity 1 Total Power Input 1 Unit EER 1 Cooling Capacity 2 Total Power Input 2 Unit EER 2 SPL (Sound Pressure Level) 3 PWL (Sound Power Level) 4 Evaporator type Dimensions - L x D x H Operating Weight kW kW dB(A) dB(A) mm kg CB4031 CB4036 dB(A) dB(A) 307 101 3,05 339 115 2,94 78 97 344 117 2,95 384 137 2,81 78 97 mm kg 3691 kW kW kW kW L Model (Extremely Low Noise Model) Refrigerant R134a Cooling Capacity 1 Total Power Input 1 Unit EER 1 Cooling Capacity2 Total Power Input 2 Unit EER 2 SPL (Sound Pressure Level) 3 PWL (Sound Power Level) 4 Evaporator type Dimensions - L x D x H Operating Weight kW kW kW kW dB(A) dB(A) mm kg Q Model (Quiet Model) Refrigerant R134a Cooling Capacity 1 Total Power Input 1 Unit EER 1 Cooling Capacity 2 Total Power Input 2 Unit EER 2 SPL (Sound Pressure Level) 3 PWL (Sound Power Level) 4 Evaporator type Dimensions - L x D x H Operating Weight 1 2 3 4 CL4031 kW kW dB(A) dB(A) mm kg CB4039 389 132 2,94 428 152 2,81 78 97 Plate Heat Exchanger 4021x2260x2570 3.740 3.785 CL4036 CL4039 CG4046 297 97 3.07 331 114 2.90 65 84 CQ4039 344 387 108 124 3,19 3,11 384 426 128 145 3,00 2,95 65,5 65,5 85 85 Plate Heat Exchanger 4021x2260x2570 5017x2260x2570 3742 4.286 4.332 CG4058 CG4066 531 575 645 162 174 198 3,28 3,30 3,26 574 622 692 181 195 220 3,18 3,19 3,14 80 81 81 100 101 101 Shell & Tube 6013x2260x2570 7009x2260x2570 6.268 6.288 6.837 6.854 CB4046 CB4052 CB4058 426 141 3,02 473 164 2,89 78,5 98 506 167 3,03 551 190 2,91 78,5 98 544 181 3,01 596 207 2,88 79 99 5017x2260x2570 5.040 5.132 CL4046 344 396 426 113 129 136 3,04 3,08 3,13 384 435 472 134 147 159 2,87 2,96 2,97 70 70,5 70,5 89 90 90 Plate Heat Exchanger 4021x2260x2570 5017x2260x2570 3633 3.679 4.222 4.930 CQ4036 CG4052 442 138 3,20 486 157 3,09 80 100 303 99 3.06 337 115 2,93 70 89 CQ4031 kW kW CG4039 364 412 113 127 3,21 3,24 400 447 129 142 3,10 3,14 79,5 79,5 99 99 Plate Heat Exchanger 5017x2260x2570 4.476 4.522 kW kW B Model (Base Model) Refrigerant R134a Cooling Capacity 1 Total Power Input 1 Unit EER 1 Cooling Capacity 2 Total Power Input 2 Unit EER 2 SPL (Sound Pressure Level) 3 PWL (Sound Power Level) 4 Evaporator type Dimensions - L x D x H Operating Weight CG4036 CQ4046 CL4052 CB4066 618 205 3,01 670 233 2,88 79 99 Shell & Tube 6013x2260x2570 6.089 6.112 CL4058 CL4066 506 164 3,09 554 187 2,96 71 91 736 251 2,93 800 278 2,88 80 100 7009x2260x2570 6884 CL4078 544 631 721 174 196 249 3,12 3,22 2.90 596 680 786 202 220 279 2,96 3,09 2,82 71 72 72 91 92 92 Shell & Tube 6013x2260x2570 7009x2260x2570 5.910 5.928 6.469 6674 CQ4052 CQ4058 CQ4066 421 131 3,21 470 156 3,02 66 86 495 542 603 160 166 196 3,10 3,26 3,07 544 595 656 186 194 226 2,93 3,07 2,90 66 67 67 86 87 87 Shell & Tube 6013x2260x2570 7009x2260x2570 5.996 6.020 6.557 6.579 Cooling capacity at the following standard conditions: power supply 400V/3ph/50Hz; outdoor temperature 35°C; water inlet/outlet temperature 12/7 °C; ethylene glycol 0% Cooling capacity at the following standard conditions: power supply 400V/3ph/50Hz; outdoor temperature 35°C; economizer option water inlet/outlet temperature 12/7 °C; ethylene glycol 0% Measured with outdoor temperature 35 °C; 1m from the unit; free field conditions; according to ISO 3744 With outdoor temperature 35°C; calculated according to ISO 3744 10 CB4078 Freecooling Aircooled Screw Chiller HPC-M Range G Model (The Best Efficiency Model) Refrigerant R134a Cooling Capacity 1 Freecooling Capacity 1 Total Power Input 1 Unit EER 1 Cooling Capacity 2 Total Power Input 2 Unit EER 2 SPL (Sound Pressure Level) 3 PWL (Sound Power Level) 4 Evaporator type Dimensions - L x D x H Operating Weight kW kW kW dB(A) dB(A) mm kg FB4031 FB4036 dB(A) dB(A) 322 203 105 3,06 354 121 2,92 78 97 359 207 122 2,93 399 144 2,77 78 97 mm kg 4.322 kW kW kW kW kW L Model (Extremely Low Noise Model) Refrigerant R134a Cooling Capacity 1 Freecooling Capacity 1 Total Power Input 1 Unit EER 1 Cooling Capacity 2 Total Power Input 2 Unit EER 2 SPL (Sound Pressure Level) 3 PWL (Sound Power Level) 4 Evaporator type Dimensions - L x D x H Operating Weight kW kW kW kW kW dB(A) dB(A) mm kg Q Model (Quiet Model) Refrigerant R134a Cooling Capacity 1 Freecooling Capacity 1 Total Power Input 1 Unit EER 1 Cooling Capacity 2 Total Power Input 2 Unit EER 2 SPL (Sound Pressure Level) 3 PWL (Sound Power Level) 4 Evaporator type Dimensions - L x D x H Operating Weight FL4031 kW kW dB(A) dB(A) mm kg FB4039 396 212 143 2,78 437 166 2,63 78 97 Plate Heat Exchanger 4021x2260x2570 4.371 4.416 FL4036 FL4039 FG4046 304 166 104 2,93 339 124 2,73 65 84 FQ4039 360 396 218 223 114 134 3,17 2,97 400 436 136 157 2,95 2,78 65,5 65,5 85 85 Plate Heat Exchanger 4021x2260x2570 5017x2260x2570 4.371 5.046 5.092 FG4058 FG4066 558 607 680 358 425 440 173 185 213 3,23 3,28 3,20 603 655 729 195 209 238 3,09 3,14 3,06 80 81 81 100 101 101 Shell & Tube 6013x2260x2570 7009x2260x2570 7.278 7.301 8.008 8.089 FB4046 FB4052 FB4058 447 273 148 3,03 494 172 2,87 78,5 98 517 281 180 2,88 563 207 2,73 78,5 98 579 341 191 3,04 632 220 2,88 79 99 5017x2260x2570 5.852 5.946 FL4046 353 413 439 196 256 257 122 135 146 2,90 3,07 3,00 393 451 487 145 154 173 2,71 2,92 2,82 70 70,5 70,5 89 90 90 Plate Heat Exchanger 4021x2260x2570 5017x2260x2570 4.262 4.310 4.982 5.742 FQ4036 FG4052 475 343 145 3,28 519 165 3,14 80 100 317 192 103 3,06 350 120 2,91 70 89 FQ4031 kW kW kW FG4039 383 424 280 287 118 135 3,24 3,14 418 460 135 152 3,10 3,02 79,5 79,5 99 99 Plate Heat Exchanger 5017x2260x2570 5.236 5.282 kW kW B Model (Base Model) Refrigerant R134a Cooling Capacity 1 Freecooling Capacity 1 Total Power Input 1 Unit EER 1 Cooling Capacity 2 Total Power Input 2 Unit EER 2 SPL (Sound Pressure Level) 3 PWL (Sound Power Level) 4 Evaporator type Dimensions - L x D x H Operating Weight FG4036 FQ4046 FL4052 FB4066 644 348 222 2,90 699 255 2,75 79 99 Shell & Tube 6013x2260x2570 7.100 7.154 FL4058 FL4066 FB4078 762 421 271 2,81 827 304 2,72 80 100 7009x2260x2570 8.104 FL4078 540 318 173 3,12 587 198 2,96 71 91 569 659 746 320 387 394 188 213 270 3,02 3,10 2,76 624 712 811 220 242 306 2,84 2,94 2,65 71 72 72 91 92 92 Shell & Tube 6013x2260x2570 7009x2260x2570 6.920 6.941 7.697 7.892 FQ4052 FQ4058 FQ4066 449 268 139 3,22 499 166 3,00 66 86 517 567 629 276 329 336 173 180 214 2,99 3,15 2,94 566 623 686 203 212 249 2,79 2,94 2,75 66 67 67 86 87 87 Shell & Tube 6013x2260x2570 7009x2260x2570 7.012 7.032 7.728 7.807 1 Cooling capacity at the following standard conditions: power supply 400V/3ph/50Hz; outdoor temperature 35°C; coolant inlet/outlet temperature 15/10 °C; ethylene glycol 30% Freecooling capacity at the following standard conditions: power supply 400V/3ph/50Hz; outdoor temperature 5°C; coolant inlet temperature 15°C; ethylene glycol 30%; coolant fluid flow as indicated at (1) conditions 2 Cooling capacity at the following standard conditions: power supply 400V/3ph/50Hz; outdoor temperature 35°C; economizer option coolant inlet/outlet temperature 15/10 °C; ethylene glycol 30% 3 Measured with outdoor temperature 35 °C; 1m from the unit; free field conditions; according to ISO 3744 4 With outdoor temperature 35°C; calculated according to ISO 3744 11 Liebert HPC-M Witness Test Area: Know Your Chiller Before Installing It. The goal is to help our customers achieve excellence in terms of product quality, reduced Energy consumption and improved operations. Gain confidence right from the outset: come and witness test your Liebert Chiller enjoying the new testing cabin, designed to reproduce the most severe conditions. The quality and performance of a new product starts with the Research and Development phase. It then continues with a design which employs first quality components and integrates them together to reach the highest efficiency and reliability that our customers are looking for. “Design” includes the manufacturing process and test phases, which warrant that every unit is produced to achieve the capabilities for which it has been conceived. The commitment we have with our customers is “come to see and test your product before it is shipped to your location”. Why test a product? To monitor different operating sequences that a customer may want to double check before the installation, obtain performance measurement at a given load, become familiar with the new product, or to 12 simply enjoy the pleasure to be where your unit is manufactured and tested. There are details which are important; we want you to know about them! Think about the test of a Freecooling Chiller up to 1600kW, with a tolerance up to 0.1 °C: the test cabin precisely reproduces the external working conditions, exactly those conditions that may happen one day during the year. The test cabin can fully reproduce the conditions, so you’ll be sure that if they do occur the performance of your Liebert Chiller will not be affected. Others could say “Our catalogue says it works“ ... you instead can say “I have seen it and I know it works! “. The Witness Test Cabins has been built to improve the reliability of the tests so that our customers can rely on our chillers even before installing them. 13 Emerson Network Power Business-Critical Continuity Expert TM Today’s successful businesses depend on adaptable technologies to help them respond quickly to market demands. Your data center must be built on a support infrastructure designed to match the power and cooling needs of rapidly changing IT initiatives such as virtualization and consolidation. Each IT change, move or addition will affect the entire support infrastructure so you need products and support that ensure your IT systems will operate reliably in these environments. Get More on line: www.eu.emersonnetworkpower.com 14 More than 35,000 organizations in 70 countries depend on our Business - Critical Continuity TM Promise: your IT infrastructure stays up to support your Business! 15 Ensuring The High Availability Of Mission-Critical Data And Applications. Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader in enabling Business-Critical Continuity™ from grid to chip for telecommunication networks, data centers, health care and industrial facilities. Emerson Network Power provides innovative solutions and expertise in areas including AC and DC power and precision cooling systems, embedded computing and power, integrated racks and enclosures, power switching and controls, infrastructure management, and connectivity. All solutions are supported globally by local Emerson Network Power service technicians. Liebert AC power, precision cooling and monitoring products and services from Emerson Network Power deliver Efficiency Without Compromise™ by helping customers optimize their data center infrastructure to reduce costs and deliver high availability. For more information, visit: www.Liebert.com, www.EmersonNetworkPower.com or www.Eu.EmersonNetworkPower.com Locations Emerson Network Power - Headquarters EMEA Via Leonardo Da Vinci 16/18 Zona Industriale Tognana 35028 Piove di Sacco (PD) Italy Tel: +39 049 9719 111 Fax: +39 049 5841 257 [email protected] Emerson Network Power - Service EMEA Via Leonardo Da Vinci 16/18 Zona Industriale Tognana 35028 Piove di Sacco (PD) Italy Tel: +39 049 9719 111 Fax: +39 049 9719 045 [email protected] United States 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Tel: +1 614 8880246 Contacts: Emerson Network Power has a worldwide network of Sales Representatives Offices and Distributors. To get the list of the nearest in your country, send an e mail to: [email protected] While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting fromuse of this information or for any errors or omissions. ©2011 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. HPCM0-BRO-EN-0211-01 Emerson Network Power The global leader in enabling Business-Critical Continuity™ Asia 7/F, Dah Sing Financial Centre 108 Gloucester Road,Wanchai Hong Kong Tel: +852 2572220 Fax: +852 28029250 Emerson Network Power SrL- ISO 9001:2008. Design, manufacturing, assembling and sales of chilled water mixture and equipment for high precision air conditioning. Sales of small uninterruptible power supply (UPS Small and Micro) Emerson Network Power SrL-ISO 14001:2004: Design, manufacturing, assembling and sales of chilled water mixture and equipment for high precision air conditioning. Sales of uninterruptible power supply (UPS Power). Design of uninterruptible power supply (UPS Power). Sales of small uninterruptible power supply (UPS Small and Micro). HQ Service Activities (Spare parts warehouse, Technicians training) AC Power Embedded Computing Outside Plant Racks & Integrated Cabinets Connectivity Embedded Power Infrastructure Management & Monitoring Power Switching & Controls Services Precision Cooling Surge Protection DC Power Emerson, Business-Critical Continuity and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2011 Emerson Electric Co.