R126 Reliability Data

RELIABILITY DATA
LM101A / LM301
8/21/2006
• OPERATING LIFE TEST
PACKAGE
TYPE
SAMPLE
SIZE
CERDIP
FLATPAK/LCC
HERMETIC
281
320
828
1,429
• TEMP CYCLE FROM -65°C to +150°C
PACKAGE
TYPE
SAMPLE
SIZE
OLDEST
DATE CODE
NEWEST
DATE CODE
9010
8907
8301
9709
9203
0330
OLDEST
DATE CODE
NEWEST
DATE CODE
CERDIP
FLATPAK/LCC
HERMETIC
120
8427
80
8907
449
8328
649
• THERMAL SHOCK FROM -65°C to +150°C
PACKAGE
TYPE
SAMPLE
SIZE
OLDEST
DATE CODE
K DEVICE
HOURS (1)
AT +125°C
250.51
331.97
1,368.17
1,950.65
NEWEST
DATE CODE
12.00
8.00
17.00
37.00
60
8427
8930
65
8949
0244
125
(1) Assumes Activation Energy = 1.0 Electron Volts
(2) Failure Rate Equivalent to +55°C, 60% Confidence Level = 0.94 FITS
(3) Mean Time Between Failures in Years = 121,359
Note: 1 FIT = 1 Failure in One Billion Hours.
Form: 00-03-6209B. R126
0
0
0
0
NUMBER
OF
FAILURES
K DEVICE
CYCLES
CERDIP
HERMETIC
0
0
0
0
NUMBER
OF
FAILURES
K DEVICE
CYCLES
9010
9203
0330
NUMBER
OF (2)
FAILURES
0.90
0.98
1.88
0
0
0
Rev 24