EN

Inductive sensors
IWFM 08U9501
Inductive distance measuring
sensors
dimension drawing
ø 3,1
8 4
16
ø 6,5
4,7
8
general data
photo
mounting type
quasi-flush
measuring distance Sd
0 ... 2 mm
resolution
repeat accuracy
< 0,001 mm (stat.)
< 0,005 mm (dynam.)
< 0,02 mm
linearity error
± 100 µm
temperature drift
± 5 % (Full Scale)
electrical data
response time (factory characteristic)
< 1 ms
voltage supply range +Vs
15 ... 30 VDC
current consumption max. (no load)
10 mA
output circuit
voltage output
output signal
0 ... 10 VDC
load resistance
> 3000 Ohm
short circuit protection
yes
reverse polarity protection
yes
IWFM
mechanical data
type
rectangular
housing material
die-cast zinc nickel plated
dimension
8 mm
housing length
16 mm
connection types
cable, 2 m
ambient conditions
operating temperature
10 ... +60 °C
protection class
IP 67
IWFM 08U9501
connection diagram
www.baumer.com
~
~
~
BN (1)
+VS
BK (4)
BU (3)
output
Z
0V
extra flat housing
through bore for M3 screw
24/5/2016