AN54416 Using CY8CPLC20 in Powerline Communication (PLC) Applications.pdf

AN54416
Using CY8CPLC20 in Powerline Communication (PLC) Applications
Author:Aditya Yadav
Associated Project: Yes
Associated Part Family: CY8CPLC20
Software Version: PSoC ® Designer™5.4 CP1
Related Application Notes: For a complete list of the application notes, click here.
AN54416 describes how to use the Powerline Transceiver (PLT) User Module on the CY8CPLC20 device for PLC
applications. The application note also includes a spreadsheet to estimate the power consumption by CY8CPLC20
and focuses on four code examples. The first example provides steps to develop an example project to communicate
between two nodes on the powerline. The second example discusses how to develop a UART Host interface for
CY8CPLC20. The third example discusses how to develop an I2C Host interface for CY8CPLC20. The fourth shows
how to use CY8CPLC20 with average low-power consumption of less than 50 mW.
Contents
Introduction ....................................................................... 2
CY8CPLC20 Device Description ....................................... 2
Powerline FSK Modem PHY ........................................ 2
Powerline Network Protocol Stack ............................... 2
Estimating CY8CPLC20 Power Consumption ................... 3
Powerline Transceiver User Module ............................. 3
Spreadsheet Description .............................................. 3
Example Projects .............................................................. 6
Using PLT UM in a Code Example .................................... 6
Software Requirements ................................................ 6
Using the PLT User Module in an Example Project ...... 6
UART Interface for CY8CPLC20 ..................................... 14
UART Packet Structure .............................................. 16
UART Application ....................................................... 16
UART Host Example .................................................. 16
UART Hardware Connection ...................................... 17
2
I C Interface for CY8CPLC20 .......................................... 17
PLT Configuration ...................................................... 18
I2C Interface Write Packet Structure ........................... 19
I2C Interface Read Packet Structure........................... 19
I2C Application ............................................................ 19
I2C Host Example ....................................................... 19
I2C Hardware Connection ........................................... 19
I2C Hardware Connection ........................................... 20
Low-Power Firmware for CY8CPLC20 ............................ 20
Basic Operation .......................................................... 20
Power Consumption ................................................... 21
Adaptive Carrier Detect Threshold ............................. 21
www.cypress.com
Code Example ............................................................ 21
Firmware Algorithm .................................................... 23
Implementation on Hardware ..................................... 23
Summary ......................................................................... 24
Related Application Notes ............................................... 24
Appendix A - BIU, TX, RX Interrupt Service Routines
(Section of PLT_1INT.asm) ............................................. 25
Worldwide Sales and Design Support ............................. 29
Document No. 001-54416 Rev. *H
1
Using CY8CPLC20 in Powerline Communication (PLC) Applications
Introduction
CY8CPLC20 Device Description
The Cypress PLC family is a single-chip solution for
powerline communication (PLC). Cypress‟s PLC solution
combined with a simple powerline coupling circuit form a
low-cost communication interface using the existing power
lines. This interface can be used for intelligent command
and control systems such as:



The CY8CPLC20 is a
Communication chip with a:


Programmable
Powerline
Powerline FSK Modem PHY
Powerline NetworkProtocol Stack.
Lighting control
Powerline FSK Modem PHY
Automatic meter reading
The heart of the CY8CPLC20 device is the frequency shift
keying (FSK) modem. The FSK modulator sends digital
data through two distinct frequencies: one frequency
represents a digital 1 and the other represents a digital 0
(see Figure 2). The FSK demodulator must receive the
transmitted analog signals and demodulate them to
determine the correct sequence of 1s and 0s.
Home automation
The CY8CPLC20 device combines the FSK modem and
network protocol with the Cypress PSoC® core. The PSoC
contains a 24-MHz CPU with configurable digital and
analog blocks.
Figure 1 shows a block diagram of the Cypress
CY8CPLC20 PLC solution. To interface the CY8CPLC20
device to the powerline, a coupling circuit is required.
Figure 2. Sample FSK Waveform*
0
0
1
1
0
1
0
Data
Complete PLC evaluation and development kits compliant
with PLC standards in Europe and North America are
available at www.cypress.com/go/plc.
Figure 1. Cypress CY8CPLC20 PLC Solution
1
Modulated
Signal
Powerline Communication Solution
* This diagram is only for conceptual understanding and is
not to scale
Powerline
Network Protocol
Programmable
System Resources
Digital and Analog
Peripherals
Physical Layer
FSK Modem
PLC Core
Additional System
Resources
MAC, Decimator,
I2C, SPI, UART etc.
CY8CPLC20
Embedded Application
PSoC Core
AC/DC Powerline Coupling Circuitry
Powerline NetworkProtocol Stack
The network protocol that runs on the processor supports:




Bidirectional half-duplex communication
Master-slave or peer-to-peer network topologies
Multiple masters on powerline network
Addressing

8-bit logical addressing supports up to 256
Powerline nodes

16-bit extended logical addressing supports up to
65536 Powerline nodes
Powerline

64-bit physical addressing supports up to 264
Powerline nodes
This application note also explains how to use the
Powerline Transceiver (PLT) User Module (UM) on the
CY8CPLC20 device with the help of an example project to
communicate between two nodes on the powerline.

Individual broadcast or group mode addressing
www.cypress.com

Carrier Sense Multiple Access (CSMA)
The protocol provides the random selection of a
period between 85 ms and 115 ms (out of seven
possible values in this range) in which the band-in-use
(BIU) detector must indicate that the line is not in use
before attempting a transmission.
Document No. 001-54416 Rev. *H
2
Using CY8CPLC20 in Powerline Communication (PLC) Applications

Band-In-Use (BIU)
Spreadsheet Description
A BIU detector, as defined under CENELEC EN
50065-1, is active whenever a signal that exceeds
86 dBuVrms anywhere in the range 131.5 kHz to
133.5 kHz is present for at least 4 ms. This threshold
can be configured for different end-system
applications not requiring CENELEC compliance. The
modem tries to retransmit after every 85 ms to 115 ms
when the band is in use. The transmitter times out
after 1.1 seconds to 3.5 seconds (depending on the
noise on the Powerline) and generates an interrupt to
indicate that the transmitter was unable to acquire the
Powerline.
The first tab of the associated spreadsheet
(AN54416_Power_Consumption.xls) lists the available
resources when the PLT UM is placed in a project for a
CY8CPLC20 device. For additional resources, the
calculator adds the additional current to the PLT current to
provide the total current. See Figure 3.
Note that for non-CENELEC compliant systems, the
BIU interval can be modified for improved
performance by modifying the Timing_Config register.
Refer the PLT UM datasheet for more details.

Verifies the address and packet integrity (CRC) of
received packets

Transmits acknowledgments after receiving a valid
packet, and automatically retransmits if a packet is
dropped
Estimating CY8CPLC20 Power
Consumption
This section describes how to estimate power
consumption for a CY8CPLC20 PSoC Designer™ project,
which is done using the spreadsheet available with this
document. The spreadsheet estimates power consumption
of the CY8CPLC20 device in different configurations.
PLT User Module
Cypress provides the pre-configured PLT UM for
powerline
communication
implementation
in
its
development software, PSoC Designer. A developer can
place and run this PLT UM in a CY8CPLC20 device.
The PLT UM occupies nine analog and eight digital blocks
in the CY8CPLC20 device. It has the following settings
that affect power consumption:
Analog Power = SC On/Ref High
The fields in the spreadsheet are color coded as follows:



Data entry cells are yellow
Resultant current cells are green
If the value is out of range, the cell turns red
Each field in the spreadsheet is explained as follows. As
the power of the PLT user module is already calculated,
these fields (except CPU current) only apply when adding
additional user modules (for example, PWM, ADC, and so
on).
CPU Current
Enter the frequency of the CPU in the CPU Frequency
field. The estimated CPU current will appear in the
corresponding green cell. Unused clock dividers (VC1,
VC2, and VC3) should be set to the maximum value to
minimize power.
Note When using the PLT user module, the allowed
values are between 3 MHz (SysClk/8) and 24 MHz
(SysClk/1) and the clock dividers (VC1, VC2, and VC3)
cannot be changed.
Digital Block Current
Enter the input clock value for each of the digital blocks
into the corresponding cells. For example, if a PWM is
added and has an input clock of VC1, which is set to
SysClk/6, then the frequency would be 4 MHz.
Row Current
Enter the frequency values of the used output rows into
the corresponding cells. Note that 12 MHz is the maximum
clock speed for rows.
OpAmpBias = 1 (High)
A_Buffer Power = 1 (High)
When placed and running, the PLT UM consumes ~35 mA
in receive mode and ~29 mA in transmit mode. This does
not include the CPU current, which ranges from 5.8 mA to
8.8 mA, depending on the CPU frequency.
To run the PLT UM with less power consumption, see
Low-Power Firmware for CY8CPLC20.
www.cypress.com
The second tab, shown in Figure 4, of the associated
spreadsheet lists the available resources when the PLT
user module is not placed. This is useful when
implementing dynamic reconfiguration in a project. In this
case, all resources are available and settings are
configurable. For more information on dynamic
reconfiguration, see application note AN2104 - PSoC®1 Dynamic Reconfiguration With PSoC® Designer™.
GPIO Current
The GPIO current depends on the GPIO frequency (“GPIO
Clk”) and the number of GPIOs at the same frequency
(“GPIO Count”). GPIO frequency has a 12-MHz limit
similar to the row frequency. For example, if three pins
have a 2-MHz signal, then enter „3‟ for “GPIO Count” and
„2‟ for “GPIO Clock”.
Document No. 001-54416 Rev. *H
3
Using CY8CPLC20 in Powerline Communication (PLC) Applications
An a l o g B l o c k C u r r e n t
the opamp bias level and power level of the occupied
analog blocks into the corresponding yellow cells. The
The analog block power level and opamp bias level
power level is set when the user module is started in code.
determine the current consumed by analog blocks. Enter
Figure 3. Power Consumption with PLT User Module
Estimated Power Calculations for CY8CPLC20 Family Devices (with the PLT UM placed and running)
Version 1.1
Fixed Settings for PLT UM
Reference Power SC On/Ref High
OpAmpBias
1 (High)
A_Buffer Power
1 (High)
CPU Frequency
Vdd
3.000
5.00
MHz
V
CPU Current
5.833
mA
Block Clk
Digital Block
(MHz)
DBB20
0.000
DBB21
0.000
DCB22
0.000
DCB23
0.000
DBB30
0.000
DBB31
0.000
DCB32
0.000
DCB33
0.000
Digital Block Current
Row Clk
Row
(MHz)
Row_2_Output_0
0.000
Row_2_Output_1
0.000
Row_2_Output_2
0.000
Row_2_Output_3
0.000
Row_3_Output_0
0.000
Row_3_Output_1
0.000
Row_3_Output_2
0.000
Row_3_Output_3
0.000
Row Current
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
SysClkx2Disable
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
Enter parameters in yellow
See estimated result in green
Indicates something is wrong
1
GPIO
GPIO Clk
Count
(MHz)
0
0.000
0
0.000
0
0.000
0
0.000
0
0.000
0
0.000
0
0.000
0
0.000
0
0.000
0
0.000
0
0.000
0
0.000
0
0.000
0
0.000
0
0.000
0
0.000
GPIO Current
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
Power
Analog Block
Level (0-3)
ACB02
0
ASC12
0
ASD22
0
Analog Block Current
Analog
Output Buffer
AnalogOutBuf_2
0
Analog Output Buffer Current
Estimated PLT Current
Estimated Additional Current
Estimated Total Device Current
Estimated Total Device Power
www.cypress.com
Document No. 001-54416 Rev. *H
0.000
0.000
0.000
0.000
mA
mA
mA
mA
0.000
0.000
mA
mA
RX Mode TX Mode
35.000
29.000 mA
5.833
5.833 mA
40.833
34.833 mA
204.165
174.165 mW
4
Using CY8CPLC20 in Powerline Communication (PLC) Applications
Figure 4. Power Consumption without PLT User Module
Estimated Power Calculations for the CY8CPLC20 Device (with the PLT UM not placed)
Version 1.1
CPU Frequency
Vdd
3.000
5.00
MHz
V
CPU Current
5.833
mA
SysClkx2Disable
Enter parameters in yellow
See estimated result in green
Indicates something is wrong
1
OpAmp Bias
Block Clk
Digital Block
(MHz)
DBB00
0.000
DBB01
0.000
DCB02
0.000
DCB03
0.000
DBB10
0.000
DBB11
0.000
DCB12
0.000
DCB13
0.000
DBB20
0.000
DBB21
0.000
DCB22
0.000
DCB23
0.000
DBB30
0.000
DBB31
0.000
DCB32
0.000
DCB33
0.000
Digital Block Current
Row Clk
Row
(MHz)
Row_0_Output_0
0.000
Row_0_Output_1
0.000
Row_0_Output_2
0.000
Row_0_Output_3
0.000
Row_1_Output_0
0.000
Row_1_Output_1
0.000
Row_1_Output_2
0.000
Row_1_Output_3
0.000
Row_2_Output_0
0.000
Row_2_Output_1
0.000
Row_2_Output_2
0.000
Row_2_Output_3
0.000
Row_3_Output_0
0.000
Row_3_Output_1
0.000
Row_3_Output_2
0.000
Row_3_Output_3
0.000
Row Current
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
GPIO
Count
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
GPIO Clk
(MHz)
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
GPIO Current
Reference Power
All Off
1
SC Off/Ref Low
0
SC Off/Ref Med
0
SC Off/Ref High
0
SC On/Ref Low
0
SC On/Ref Med
0
SC On/Ref High
0
Reference Circuit Current
For example, “PGA_1_Start(PGA_1_HIGHPOWER);” sets
the PGA‟s analog block current to high power. The opamp
bias level is set in the Global Resources window.
To minimize power consumption, use the lowest power
level that allows the analog block to meet system
requirements at the specified column clock frequency.
Refer to the user module‟s datasheet (for example, PGA)
to determine the performance impact of different power
levels.
Note You cannot modify the opamp bias level when the
PLT UM is placed.
An a l o g O u t p u t B u f f e r C u r r e n t
Analog output buffer power consumption is affected by the
analog buffer power level. Select the analog output buffer
power by writing „1‟ to the appropriate cell. To minimize
www.cypress.com
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
Power
Analog Block
Level (0-3)
ACB00
0
ACB01
0
ACB02
0
ACB03
0
ASC10
0
ASD11
0
ASC12
0
ASD13
0
ASD20
0
ASC21
0
ASD22
0
ASC23
0
Analog Block Current
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
0.000
0.000
0.000
0.000
0.000
mA
mA
mA
mA
mA
Estimated Total Device Current
5.833
mA
Estimated Total Device Power
29.165
mW
Analog Buffer Power
0.000
0.000
0.000
0.000
0.000
0.000
0.000
mA
mA
mA
mA
mA
mA
mA
0
0
Analog
Output Buffer
AnalogOutBuf_0
0
AnalogOutBuf_1
0
AnalogOutBuf_2
0
AnalogOutBuf_3
0
Analog Output Buffer Current
power, use high power for the buffer only if the output
frequency is greater than 50 kHz.
Note The analog output buffer current is not modifiable
when the PLT user module is placed.
Reference Circuit Current
Reference power should be set greater than or equal to
the power level of the highest-power analog block
occupied. If switched capacitor blocks are not used, the
reference power can be set to „SC Off/x‟, where x is any of
the reference level settings.
Note The reference circuit current field is only available
when the PLT UM is not placed.
Document No. 001-54416 Rev. *H
5
Using CY8CPLC20 in Powerline Communication (PLC) Applications
Example Projects
Using PLT UM in a Code Example
This application note also discusses four example
projects. To use these example projects, you should be
familiar with PSoC Designer. To learn more about
PSoC Designer,
you
can
see
the
link
www.cypress.com/?id=1162. A brief overview of each
code example is given here:
The PLT UM can be implemented on the device
CY8CPLC20. This section describes how to develop a
PLC application to communicate between two nodes with
the device CY8CPLC20.
Project
Description
Using PLT UM in a
Code Example
Associated
project:AN54416_PL
C_Transceiver
UART Interface for
CY8CPLC20
Associated project:
AN54416_UART_Ho
st_Interface
I2C Interface
CY8CPLC20
Low-Power
Firmware
CY8CPLC20
Software Requirements
Develop a PLC application to
communicate between two nodes
with the device CY8CPLC20.
Explains the UART configuration,
packet structure, application, and
provides an example algorithm for
how the host communicates with
the CY8CPLC20 device.
for
Associated project:
AN54416_I2C_Host
_Interface
for
Associated project:
AN54416_PLC_Low
_Power
The user is expected to know how to use PSoC Designer.
To learn more about PSoC Designer, you can see the link
www.cypress.com/?id=1162.
Explains the I2C configuration,
packet structure, application, and
provides an example project.
Shows how the Cypress PLC
device can perform with an
average low power consumption
of < 50 mW.


PSoC Designer 5.4 CP1 or higher
PSoC Programmer 3.14 or higher
These software tools can be
www.cypress.com/psocdesigner.
downloaded
from
Using the PLT UM in an Example Project
This section provides a guide to get started with the PLT
UM. The general steps are:
1.
Open PSoC Designer and create a new chip-level
Project.
2.
Select a CY8CPLC20 device (-28PVXI for 28-pin
SSOP or -48LFXI for 48-pin QFN) as shown in Figure
5.
3.
Both devices have the same number of available
hardware
blocks
and
memory
but
the
48-pin device has more GPIO pins.
Figure 5. Select Project Type
www.cypress.com
Document No. 001-54416 Rev. *H
6
Using CY8CPLC20 in Powerline Communication (PLC) Applications
Figure 6. CY8CPLC20 User Modules
4.
In the User Modules window, open the Powerline Communication folder and double-click the PLT User Module to place
it as shown in Figure 6.
When placing the PLT User Module, a window pops up, showing three options (see Figure 7).
“FSK Modem”
With this choice, only the FSK Modem is implemented. The user can implement a custom networking protocol to manage
the communication over the powerline.
“FSK Modem + Network Stack”:
With this option, the FSK modem and a proprietary network protocol layer is implemented. The user needs to create a
custom application that uses the provided protocol to communicate over the powerline.
“FSK Modem + Network Stack + I2C Bridge”:
With this option, the FSK modem a proprietary network protocol layer and an I2C bridge is implemented. There are no
APIs to communicate with the network layer; instead the system will receive commands from the external I2C host. For
detailed steps on how to implement this, see “I2C Interface for CY8CPLC20.”
Select the “FSK Modem + Network Stack”option. With this option, the FSK modem and the proprietary Cypress network
protocol is implemented. This allows you to focus on your custom application, while the network protocol manages the
CSMA, transmission, reception, and error detection. For details regarding the other two options, refer to the PLT UM
datasheet.
www.cypress.com
Document No. 001-54416 Rev. *H
7
Using CY8CPLC20 in Powerline Communication (PLC) Applications
Figure 7. PLT Multi-User Module Selection Window
5.
Open the PLT Configuration Wizard and set the properties shown in Figure 8 and Table 1. Note that these properties can
also be set in the application code using the PLT memory array.
Figure 8. PLT Config Wizard
www.cypress.com
Document No. 001-54416 Rev. *H
8
Using CY8CPLC20 in Powerline Communication (PLC) Applications
Table 1. PLT UM Configuration
No.
Property
Register
Value
1
Baud Rate
Modem_Config
2400bps (default)
Sets the baud rate for the PLC PHY
2
Tx Gain
TX_Gain
1.55Vp-p (default)
Set to 1.55 Vp-p. Set to 125 mVp-p (for
CENELEC).
3
Rx Gain
Rx_Gain
250uVrms
Sets the minimum input sensitivity for
the receiver
4
No ACK Received Interrupt
INT_Enable
Enable
Enable Interrupt for no
acknowledgment received after if
Service Type = 1 (ACK Mode)
5
No Response Received Interrupt
INT_Enable
Enable
Enable Interrupt for No Response
Received
6
Rx Packet Dropped Interrupt
INT_Enable
Enable
Enable Interrupt when RX Packet is
dropped because RX Buffer is full
7
Rx Data Available Interrupt
INT_Enable
Enable
Enable Interrupt when RX buffer has
new data
8
Tx Data Sent Interrupt
INT_Enable
Enable
Enable Interrupt when TX data is sent
successfully
9
Transmit Enable
PLC_Mode
Enable
Enables Transmit Mode
10
Transmit Source Address Type
TX_Config
Logical Address (default)
Logical Address / Physical Address
11
Transmit Destination Address Type
TX_Config
Logical Address (default)
Logical Address / Group Address /
Physical Address
12
Transmit Service Type
TX_Config
Acknowledgement Mode
Transmissions are acknowledged
13
Transmit Retry Count
TX_Config
3
Number of times a transmitter should
retry before sending a new packet
14
Transmit Payload Length
TX_Message_Leng
th
0
Length of the payload
15
Receive Enable
PLC_Mode
Enable
Enable Receiver Mode
16
Noise Threshold Value
Threshold_Noise
87dBuV (default)
Threshold for BIU detection (set to
87 dBuV for CENELEC)
17
Band In Use
PLC_Mode
Enable (default)
Should be enabled for CENELEC
18
BIU Time Interval (min)
Timing_Config
85ms (default)
85 ms for CENELEC
19
BIU Time Interval (span)
Timing_Config
30ms (default)
30 ms for CENELEC
20
BIU Timeout
Timing_Config
1.1s Timeout (default)
1.1 s for CENELEC
www.cypress.com
Document No. 001-54416 Rev. *H
Details
9
Using CY8CPLC20 in Powerline Communication (PLC) Applications
No.
Property
Register
Value
Details
21
BIU Timeout Interrupt
INT_Enable
Enable (default)
Enable Interrupt for BIU Timeout and
the Modem is unable to Transmit, if
Disable BIU = 0
22
ACK Timeout
Timing_Config
Auto +20ms
Time for which Transmitter waits for
ACK
23
Lock Configuration
PLC_Mode
Unlock (default)
Allow device to be configured
remotely
24
Rx Overwrite
PLC_Mode
Disable (default)
If RX Buffer is full, new RX Message
isdropped.
25
Destination Address Verification
PLC_Mode
Do not Ignore
Check if the Destination Address is a
match before processing the packet
26
CRC Address Verification
PLC_Mode
Do not Ignore
Drop the packet if CRC fails
27
Addressing Mode
PLC_Mode
8bit
28
Logical Address of Node
Local_LA_LSB
Local_LA_MSB
0
In this project, Logical Address is set
in the code.
29
Single Group Membership ID
Local_Group
0
For this example project Group
Membership is not used
30
Multiple Group Membership ID
Local_Group_Hot
0x0
For this example project Group
Membership is not used
31
FSK Bandwidth
Modem_ Config
3kHz (default)
Separation of FSK signals for logic „1‟
and „0‟
32
Modem Tx Delay
Modem_ Config
7ms (default)
This value is dependent on the BAUD
rate
Select between 8bit and 16bit
Note These settings can also be done with the following application code (not included in the example project as it is
already done in the PLC Config Wizard).
/* Set the baud rate to 2400bps with a 3kHz deviation */
PLT_Memory_Array[Modem_Config] = (Modem_FSKBW_3M | Modem_BPS_2400);
/* Enable the PLC Transmitter and Receiver*/
PLT_Memory_Array[PLC_Mode] = (TX_Enable | RX_Enable);
/* Enable Acknowledgement and 3 retries*/
PLT_Memory_Array[TX_Config] = (TX_Service_Type | 0x03);
/* Set the transmitter gain to 1.55Vp-p.*/
PLT_Memory_Array[TX_Gain] = 0x0b;
/* Set the receiver gain to 250uVrms */
PLT_Memory_Array[RX_Gain] = 0x06;
/* Set the length of the transmit buffer to 0x00 */
PLT_Memory_Array[TX_Message_Length] = 0x00;
/* Enable Interrupt reporting for all events */
PLT_Memory_Array[INT_Enable]
=
(INT_UnableToTX
|
INT_TX_NO_ACK
INT_RX_Packet_Dropped | INT_RX_Data_Available |INT_TX_Data_Sent);
6.
|INT_TX_NO_RESP
|
Select Build > Generate Configuration (or press Ctrl + F6) to generate the configuration that includes the user module
assembly and C code needed for the application.
www.cypress.com
Document No. 001-54416 Rev. *H
10
Using CY8CPLC20 in Powerline Communication (PLC) Applications
7.
Place an LCD UM and three LED UMs with the following parameters:
a.
LCD UM:
Name = “LCD” LCD_Port = “Port_4”. A LCD can be directly connected to the available LCD port.
i.
b.
c.
d.
3 x LED UM (The corresponding LEDs are already hardwired to the respective pins on the Cypress PLC
Development Kits CY3274)
i.
Name = “BIU_LED”, Port = “Port_2”, Pin = “Port_2_1”, Drive = “Active High”
ii.
Name = “RX_LED”, Port = “Port_2”, Pin = “Port_2_3”, Drive = “Active High”
iii.
Name = “TX_LED”, Port = “Port_2”, Pin = “Port_2_5”, Drive = “Active High”
Update the BIU, TX, and RX ISR code snippets in the PLT_1INT.asmfile from Appendix A - BIU, TX, RX Interrupt
Service Routines (Section of PLT_1INT.asm). Each ISR enables the appropriate LED when the status is active (for
example, turn on TX_LED when transmitting) or disables the appropriate LED when the status is complete.
i.
PLT_BIU_Active_ISR: This ISR is called when Band-In-Use is active
ii.
PLT_BIU_Complete_ISR: This ISR is called when Band-In-Use is no longer set
iii.
PLT_TX_Active_ISR: This ISR is called when the Transmitter is actively sending a message
iv.
PLT_TX_Complete_ISR: This ISR is called when the Transmitter has completed sending the message
v.
PLT_RX_Active_ISR: This ISR is called when the Receiver is in process of receiving a packet
vi.
PLT_RX_Complete_ISR: This ISR is called when the Receiver is no longer receiving a packet
Buttons
i.
Set P0[1] according to the settings shown below. This pin P01 should be manually connected to the button with a
jumper wire, which will be used to switch the transmit state on and off.
Name
ii.
Tx_Trigger
Port
P0[1]
Port
StdCPU
Drive
Pull Down
Interrupt
Falling Edge
Initial Value
0
Set P0[4] according to the settings shown below. This ping is used to select the Local Logical Address of
device.
Name
8.
ADD_Select
Port
P0[4]
Port
StdCPU
Drive
Pull Up
Interrupt
DisableInt
Initial Value
1
Copy the main.c code from the attached code example into this project‟s main.c file. A flowchart of the application code
and the block diagram are in Figure 9 and Figure 10 respectively. A high-level description of the code is as follows:
a.
The PLT and LCD User Modules are initialized. The global interrupts are enabled. The PLT UM is configured.
b.
Check if the Pin ADD_Select is HIGH. If yes, set the Local Logical Address to 0x01 and Destination Address to 0x02.
Otherwise, set the Local Logical Address to 0x02 and Destination Address to 0x01.
www.cypress.com
Document No. 001-54416 Rev. *H
11
Using CY8CPLC20 in Powerline Communication (PLC) Applications
c.
After the initial configuration, the Host will continuously loop to check for a received message. If a packet is received,
the RX_Count is incremented and the LCD is updated. If the transmitter mode is enabled, then the Tx_Count is also
updated on the LCD.
d.
When a GPIO interrupt occurs (for example, a button press) on pin P01, the transmitter state is inverted. If the
transmitter is enabled, then a packet is transmitted to the destination address in the TX_DA register. TX_Count is
incremented and the LCD is updated. If an acknowledgement is received, then the TX_Success_Count is
incremented and the LCD is updated. The PSoC Host will continue to initiate data transmission until a GPIO interrupt
occurs again.
Figure 9. Block Diagram of Example Project
P2[1]
P2[3]
P2[5]
TX Trigger
P0[1]
ADD Select
P0[4]
Start
CY8CPLC20
(Transceiver)
P4[7:0]
BIU LED
RX LED
TX LED
Figure 10. Code Example Flow Chart
LCD Display
Initialize PLT and LCD
Enable GPIO interrupt (button press)
Configure PLT UM
Powerline
FSK Signal
BIU LED
RX LED
TX LED
P2[1]
P2[3]
P2[5]
TX Trigger
P0[1]
ADD Select
P0[4]
CY8CPLC20
(Transceiver)
P4[7:0]
Pin ADD_Select = HIGH?
No
Yes
LCD Display
PLC Logical Address = 0x01
PLC Transmit Destination Address =
0x02
PLC Logical Address = 0x02
PLC Transmit Destination Address =
0x01
PLC Message
Received?
No
GPIO Interrupt
(Button press)
Yes
No
Increment received count
Display received count on LCD
Invert Transmitter State
Transmitter State enabled?
No
Return to Main
Yes
Start PLC transmission
Increment TX count
Display Transmit Statistic on LCD
TX Success
(Acknowledgment
Received)?
No
Yes
Increment TX Success count and
display on LCD
www.cypress.com
Document No. 001-54416 Rev. *H
12
Using CY8CPLC20 in Powerline Communication (PLC) Applications
Figure 13. Programming Settings
Evaluating the Example Project on
Hardware
This example is designed to run on the CY3274 highvoltage PLC DVK. You can see the latest kit
documentation for this board (CY3274). The BIU, RX, and
TX LEDs on the board are hardwired to P2[1], P2[3], and
P2[5], respectively.
Programming the Boards
1. Connect the LCD daughter card to the LCD
connector.
2.
Connect the power cable to one of the boards. The
Blue Power LED should turn on.
Figure 11. Hardware Setup for CY3274
Reset Button
7.
Click the arrow at the bottom right corner to start
programming. After the progress bar is complete, the
status should say „Programming Successful‟.
8.
Remove MiniProg from the ISSP header and press
the RESET pushbutton to reset the device.
9.
Repeat the above steps to program another board.
ISSP Header
Hardw are Setup
Follow the steps below to set up the board as shown in
Figure 14.
3.
Attach one end of the MiniProg programmer to the
ISSP header and the other end to the PC through the
USB cable.
Figure 14. Hardware Setup for CY3274
Figure 12. Connecting the MiniProg Programmer
4.
Open PSoC Designer and
AN54416_PLC_Transceiver.
5.
Click Program > Program Part.
6.
On the Program Part window, set “Acquire Mode” to
Reset. This is because the board is already powered.
www.cypress.com
open
the
project
1.
Connect P0[1] to Switch SW (this is the Switch S4 for
toggling the Tx state).
2.
Connect P0[4] to one of the 8 DIP switches.
3.
Power up the board and make sure the blue power
LED is turned ON.
4.
Repeat Steps 1 to 3 to set up the second board.
Document No. 001-54416 Rev. *H
13
Using CY8CPLC20 in Powerline Communication (PLC) Applications
5.
6.
Turn on the DIP switch on the first board and reset it.
Make sure the other board the DIP switches is
different. The board should display local logical
address, LA=02. Press the reset button on both
boards to load the addresses.
Press the switch S4. The first board will continuously
transmit 1000 packets to the second board with
logical address 0x01.
Figure 15. Transmitter Board After Sending 10
Packets
Destination Address of
Transmitted Packets
UART Interface for CY8CPLC20
U AR T C o n f i g u r a t i o n
The UART in this code example is designed to run at
9600 bps, which means a 76.8 kHz clock needs to be
generated (8x the UART baud rate). Since the VC1, VC2,
and VC3 clock dividers are used by the PLT user module,
a PWM8 user module is needed.
Figure 17. UART Connections
Number of Received
Packets
Number of Transmitted Packets Acknowledged /
Total Number of Transmitted Packets
When the tranceiver is transmitting, the LCD updates
the destination address and the transmitter statistics,
that is., total number of succesfully transmitted data
packets upon the total number of transmitted packets.
Figure 16. Receiver LCD after Receiving 10 Packets
Source Address of
Received Packets
Number of Received
Packets
In this example, Pin P1[2] will be the input (RX) and P1[6]
will be the output (TX).
1.
Place a PWM8 user module (PWMs folder) and set
the following parameters (including Name) shown in
Figure 18. The clock frequency is determined by
knowing (from the Global Resources window) that
VC2 = (VC1 / 6) = ( (SysClk / 2) / 6) = 2 MHz. The
actual divider for this clock is (Period + 1) = 26.
Therefore, the generated clock from the PWM is
2 MHz / 26 = 76.9 kHz.
Figure 18. PWM8_UART Parameters
Number of Transmitted Packets Acknowledged /
Total Number of Transmitted Packets
When the tranceiver is receiving the LCD updates the
source address and the number of received data
packets.
www.cypress.com
Document No. 001-54416 Rev. *H
14
Using CY8CPLC20 in Powerline Communication (PLC) Applications
2.
Place a UART UM (Digital Comm folder) and set the
following parameters (including Name) shown in
Figure 19. The key parameters are Clock, RX Input,
TX Output, ClockSync, and RxCmdBuffer. Note that
the Clock input is from the bus that is connected to
the output of the PWM8_UART.
Figure 21. Row 2 Input 2 Connection
Figure 19. UART Parameters
b.
UARTTx should be connected to P1[6].
Set the P1[6] properties as shown in Figure 22.
Connect Row_2_Ouput_2 to the column bus
GlobalOutOdd_6, as shown in Figure 23.
Figure 22. Pin P1[6] Parameters
3.
UART Pinouts
a.
UART Rx should be connected to P1[2].
Set the P1[2] properties as shown in Figure 20.
Connect
column
bus
GlobalInOdd_2
Row_2Input_2, as shown in Figure 21.
to
Figure 20. Pin P1[2] Parameters
Figure 23. Row 2 Output 2 Connection
www.cypress.com
Document No. 001-54416 Rev. *H
15
Using CY8CPLC20 in Powerline Communication (PLC) Applications
UART Packet Structure
To run the UART in the application, it is important to understand how and when the packets are sent to and from the host. The
host always initiates communication and configures the PLT user module, transmits, and receives data by writing to and
reading from the PLT_Memory_Array table. To write data, the host must send a write packet. To read data, the host must send
a read packet and then wait for the CY8CPLC20 device to reply with a read response packet. Host write packets are
processed immediately by the CY8CPLC20 device (handled in an ISR Host_UART_ISR). However, the response packets
are transmitted only when the device is not busy.
U AR T I n t e r f a c e H o s t W r i t e P a c k e t S t r u c t u r e
When the host wants to write data to the PLT_Memory_Array, it sets the MSb of the first byte to „0‟ to indicate a write. The
remaining seven bits indicate how many bytes will be written to the memory array. The next byte indicates the starting offset of
the PLT_Memory_Array that will be written to. The subsequent bytes contain the data that will be stored.
7
Byte 0
0
Byte 1
Offset
Byte 2+
Data
6
5
4
3
2
1
0
Length
U AR T I n t e r f a c e H o s t R e a d P a c k e t S t r u c t u r e
When the host wants to read data from the PLT_Memory_Array, it sets the MSb of the first byte to „1‟ to indicate a read. The
remaining seven bits indicate how many bytes should be read from the memory array. The next byte indicates the starting
offset of the PLT_Memory_Array that will be read from.
7
Byte 0
1
Byte 1
Offset
6
5
4
3
2
1
0
Length
U AR T I n t e r f a c e C Y 8 C P L C 2 0 R e a d R e s p o n s e P a c k e t S t r u c t u r e
After receiving the read command, the device responds by sending the requested data from the PLT_Memory_Array. The
number of bytes to send was set by the Length parameter in the Read packet from the host.
7
Byte 0+
6
5
4
3
2
1
0
Data
UART Application
When a new byte of data is received, the ISR Host_UART_ISR is triggered. This executes a state machine based on the byte
position of the packet that is received. Initially, the position is 0, so the length and read/write bit will be stored. Then, based on
the read/write bit, the subsequent received bytes are processed accordingly. To make sure that the byte position is aligned
correctly, a timeout resets the positions if a byte is not received within ~2.5 ms. A byte should be received every ~1.25 ms
(9600 bps including start and stop bits), so there is a buffer of ~100%. The 2.5 ms timeout is achieved by incrementing the
value bUART_Cycles in the PWM8_UART_ISR, which occurs for every cycle (76.9 kHz). After the value reaches 200, the
timeout occurs.
If a read packet is successfully received, the requested data is transferred to the TX buffer as a response packet. Also, a flag
bHost_Reply is set to notify the application that there is a message to be sent. When the application code reaches the
point to check for this flag, it transmits the response.
UART Host Example
An example algorithm of a host trying to send a PLC message is:
1.
Send {0x01, 0x06, 0x81} which writes the value 0x81 to PLT_Memory_Array[0x06] to send a one-byte message
2.
Send {0x81, 0x69} which reads from PLT_Memory_Array[0x69] to read the status of transmission
3.
Wait until receiving one byte of data
4.
If the received byte contains an event update of the transmission, it is done. Otherwise, repeat step 2.
www.cypress.com
Document No. 001-54416 Rev. *H
16
Using CY8CPLC20 in Powerline Communication (PLC) Applications
UART Hardware Connection
On the PLC DVKs, to connect the CY8CPLC20 device to the RS232 port, connect a jumper wire from P12 to RX on header
J20 and another wire from P16 to TX on header J20, as shown with the white wires in Figure 24.
Figure 24. UART Hardware Connection
I2C Interface for CY8CPLC20
This section describes how the I2C interface is developed. The I2C interface is compatible with the Cypress PLC control panel
GUI, which can be downloaded here. This section explains the I2C configuration, packet structure, application, and provides an
example algorithm for how the host communicates with the CY8CPLC20 device.
www.cypress.com
Document No. 001-54416 Rev. *H
17
Using CY8CPLC20 in Powerline Communication (PLC) Applications
PLT Configuration
Follow these steps to set up the PLT UM with I2C interface:
1.
Place the PLT UM and Select the “FSK Modem + Network Stack + I2C Bridge” option as shown below.
Figure 25. Select Option "FSK Modem + Network Stack + I2C Bridge"
2.
#include <m8c.h>
// part specific constants and macros
#include"PSoCAPI.h"
//
PSoC
API
definitions for all user modules
void main(void)
{
PLT_Start();
//Initialize the PLT module
do
{
PLT_Check_I2C_Activity();
//Act on any I2C activity
PLT_Poll();
// Run the network protocol
}while(1);
}
Set the I2C address in the PLT Configuration window.
Note that all the other parameters are set by the Host.
Figure 26. PLT Configuration
3.
Copy the sample code below for “FSK Modem +
2
Network Stack + I C Bridge”.
www.cypress.com
4.
3 x LED UM (The corresponding LEDs are already
hardwired to the respective pins on the Cypress PLC
Development Kit CY3274)
Document No. 001-54416 Rev. *H
18
Using CY8CPLC20 in Powerline Communication (PLC) Applications
5.
a.
Name = “BIU_LED”, Port = “Port_2”, Pin =
“Port_2_1”, Drive = “Active High”
a.
PLT_BIU_Active_ISR: This ISR is called when
the Band In Use is active
b.
Name = “RX_LED”, Port = “Port_2”, Pin =
“Port_2_3”, Drive = “Active High”
b.
PLT_BIU_Complete_ISR: This ISR is called
when the Band In Use is no longer set
c.
Name = “TX_LED”, Port = “Port_2”, Pin =
“Port_2_5”, Drive = “Active High”
c.
PLT_TX_Active_ISR: This ISR is called when the
Transmitter is actively sending a message
Update the BIU, TX and RX ISR code snippets in
PLT_1INT.asm from Appendix A - BIU, TX, RX
Interrupt
Service
Routines
(Section
of
PLT_1INT.asm). Each ISR enables the appropriate
LED when the status is active (for example, turn on
TX_LED when transmitting) or disable the appropriate
LED when the status is complete.
d.
PLT_TX_Complete_ISR: This ISR is called when
the Transmitter has completed sending the
message
e.
PLT_RX_Active_ISR: This ISR is called when the
Receiver is in process of receiving a packet
f.
PLT_RX_Complete_ISR: This ISR is called when
the Receiver is no longer receiving a packet
I2C Interface Write Packet Structure
The I2C interface follows the packet structure defined by the I2C specification. The write packet is as follows. The master
always sends the entire packet.
7
6
5
4
Byte 0
I2C Address (0b0000001)
Byte 1
Offset
Byte 2+
Data from host to CY8CPLC20 (Optional)
3
2
1
0
0
I2C Interface Read Packet Structure
The I2C interface follows the packet structure defined by the I2C specification. The read packet is as follows. The master sends
the first byte. The offset is set by sending a write packet for that offset (sending data is not necessary).
7
6
Byte 0
I2C Address (0b0000001)
Byte 1+
Data from CY8CPLC20 to host
5
4
3
2
1
0
1
I2C Application
The I2C write and read messages are processed
automatically by the EzI2Cs user module by the ISRs
associated with the user module. It is important to note
that I2C interrupts are disabled by the PLT user module
when it is transmitting. During this time, if the host initiated
an I2C message, the CY8CPLC20 device holds the SCL
bus low until it finishes transmitting the PLC packet. It then
resumes processing the I2C message.
1.
Send {0x02, 0x06, 0x81} which writes the value 0x81
to the PLT_Memory_Array[0x06] to send a one-byte
message
2.
Send {0x03, 0x69} which reads from the
PLT_Memory_Array[0x69] to read the status of
transmission
3.
Read one byte of data
4.
If the received byte contains an event update of the
transmission, it is done. Otherwise, repeat step 2.
I2C Host Example
I2C Hardware Connection
An example algorithm of a host trying to tell the
CY8CPLC20 message (I2C address 0x01) to send a PLC
message would be (Note that the I2C address is shifted left
by one bit):
On the PLC DVKs, to connect the CY8CPLC20 device to
the PC, a CY3240 Cypress USB-I2C bridge can be
connected to the 5-pin I2C header, as shown in Figure 27.
www.cypress.com
Document No. 001-54416 Rev. *H
19
Using CY8CPLC20 in Powerline Communication (PLC) Applications
I2C Hardware Connection
On the PLC DVKs, to connect the CY8CPLC20 device to the PC, a CY3240 Cypress USB-I2C bridge can be connected to the
5-pin I2C header, as shown in Figure 27.
Figure 27. I2C Hardware Connection
Low-Power Firmware for CY8CPLC20
This section describes how the Cypress PLC device can
perform with an average low-power consumption of
< 50 mW. The code example for the CY8CPLC20 is
attached.
Basic Operation
Under normal receive mode operation; CY8CPLC20
devices consume ~43 mA of current, which is equivalent
to 215 mW of power at 5-V VCC. For systems that have a
requirement of <50 mW average power consumption, the
PLC device can be configured in a low-power „listen‟
mode, where it turns off most of the PLT blocks, turn on
the carrier detect blocks, and wait to detect a signal on the
www.cypress.com
powerline. After a signal is detected, the device turns on
the remaining PLT blocks for demodulating the PLC signal
and forming the PLC packet.
If the packet is intended for this node, the PLC device
processes it and then returns to ‟listen‟ mode. If the packet
received is not intended for this node or if there is
excessive noise that wakes the node up, the device
returns to‟listen‟ mode when the carrier detection is lost or
after a 300-ms timeout period. See the following figure for
the basic low-power algorithm.
Document No. 001-54416 Rev. *H
20
Using CY8CPLC20 in Powerline Communication (PLC) Applications
Figure 28. PLC Low-Power Firmware Basic Operation
Table 2. Average Power Consumption
Average Power
(mW)
Start
Current
(mA)
Listen Mode
Put PLT into low
power listen mode
Receive Mode
Power
(mW)
97% Free Line
7
35
34
43.6
218
6.5
Total
40.54
Adaptive Carrier Detect Threshold
The carrier detect threshold is designed to adapt to the
noise on the line so that the average power consumption
stays under 50 mW. If noise causes two consecutive false
triggers, the threshold is increased. On the other hand, if
there is no signal on the line for >500 ms, the threshold is
decreased. This is to ensure that the device has the best
sensitivity possible while consuming <50 mW.
Put device in sleep
mode for ~2 ms
(sleep timer
period)
Carrier
Detected?
N
To differentiate between noise and PLC signals, the free
time between carrier detections is measured. According to
the CENELEC Band-In-Use (BIU) protocol, which is used
by the Cypress PLC solution, there must be at least 85-ms
free time before another PLC signal can be transmitted.
Note that this system uses 80 ms as the threshold.
Y
Put PLT in full
power mode
Start packet timer
for 300 ms
Message
received?
N
Y
Signal
lost for >1 ms
or packet timer
expired?
The minimum threshold is 125 µVrms and the maximum
threshold is 5 mVrms. Therefore, if a signal that exceeds
this carrier detect threshold is present for at least three
sleep timer cycles (~6 ms total), the device switches to the
receive mode so that it can demodulate the PLC signal.
The TX Delay parameter should be set to the maximum
(25 ms) in order to provide enough time for the receiver to
detect the signal and switch to receive mode in time to
demodulate the signal.
N
Y
Code Example
The code example was created with PSoC Designer 5.4.
A screenshot of the chip level view of the code example is
shown in Figure 29. The following user modules are used
in the code example:
Process Message
Power Consumption
In the „listen‟ mode, the device‟s current consumption was
8.8 mA (power consumption of 44 mW). In the normal
receive mode, the device‟s current consumption was 43
mA (power consumption of 215 mW). If the line is clean at
least 97% of the time, the total average power consumed
is <50 mW as seen in Table 2.
www.cypress.com



Powerline Transceiver
Counter16: For the 300 ms timeout. The configuration
is shown in Figure 30.
OneShot: Stabilizes the filtered received signal to
generate a constant high logic level when a carrier is
present. It drops to a low logic level when the carrier
is absent for ≥ 8 * clock period = 8 * ~50 µs =
~400 µs. The configuration of the OneShot user
module is shown in Figure 31. The output of the
OneShot User Module is connected to the port pin
P2[6] to be monitored for the carrier detection in code.
Document No. 001-54416 Rev. *H
21
Using CY8CPLC20 in Powerline Communication (PLC) Applications

LED: Three LED user modules (TX, RX, BIU) are
used to represent when the PLT User Module is
transmitting, receiving, or has detected a BIU timeout
condition, respectively. In the debug mode (when
PLC_DEBUG = 1), there are two additional LED user
modules that are used to indicate the power mode of
the device. ReceiveMode_LED will go low when the
PLT is in „listen‟ mode and go high when in full-power
receive
mode.
In
the
listen
mode,
the
SleepMode_LED user module will go HIGH when the
CPU is in low-power sleep mode, go LOW when it is
checking for a carrier. In full-power receive mode, the
SleepMode_LED will always be LOW. The pins used
are as follows:

After placing the user modules, the following global
resources were modified to reduce power consumption:



P2[1] = BIU LED

P2[3] = RX LED

P2[5] = TX LED

P1[2] = Sleep Mode LED

P1[6] = Full Power Receive LED
LCD: When a message is received, it will display the
first byte of data on the second row of the LCD. The
LCD also displays the number of messages received
on the first row of the LCD. In the debug mode (when
PLC_DEBUG = 1), it will also display the carrier
detect threshold level in the bottom right corner of the
LCD.

CPU Clock = SysClk / 8. Running the CPU at this
frequency (3 MHz) will reduce the current
consumption by ~3mA.
SysClk*2 Disable = Yes. Since the 48-MHz clock is
not used, this can be disabled. This will reduce the
current consumption by ~1mA.
Analog reference power, opamp bias, and analog
buffer power. These settings are dynamically modified
in the firmware. In the listen mode, they are set to low
power. In receive mode, they are set to high power.
Figure 29. PLC Low-Power PSoC Designer Chip View
www.cypress.com
Document No. 001-54416 Rev. *H
22
Using CY8CPLC20 in Powerline Communication (PLC) Applications
Figure 30. Counter16 Configuration
Figure 31. OneShot Configuration
Firmware Algorithm
The firmware is written in C, with the exception of the PLT
interrupt routines (in PLT_1INT.asm), which are modified
to drive the transmit, receive, and band-in-use LEDs.
The algorithm for the code example is shown in Figure 32
and it is based on the basic operation diagram shown in
Figure 27. It has additional details on detecting the carrier,
as well as adapting the threshold based on the noise in
the system. The received message is processed by
incrementing a count and displaying it on the LCD.
To evaluate the system, a second PLC board with an I2C
interface can be used. The PLC Control Panel GUI can be
run on a PC and interfaced to the board with the CY3240
USB-I2C bridge board (included in the PLC kits).A highvoltage AC example using two CY3274 boards is shown in
Figure 33. The receiving board displays the number of
packets successfully received on an LCD display. The
PLC Control Panel GUI can be downloaded at
www.cypress.com/?rID=38135. The GUI user‟s guide
contains instructions for programming the PLC DVKs to
work with the GUI.
The receiving board is programmed with the listen mode
firmware. The transmitting board has the following
configuration (set by the GUI):


Implementation on Hardware
The attached code example uses the same hardware as
any of the PLC development kits (CY3274).
1.
Connect the LCD User Module to the LCD header.
2.
Connect the power cable from the mains to the board.
The blue power LED should turn ON.
3.
Connect the USB cable from the PC to the MiniProg
programmer (included in the DVKs).
4.
Connect the MiniProg to the ISSP connector.
5.
Open the project in PSoC Programmer or in
PSoC Designer. Click Program>Program Part. Load
the PLC_Low_Power.hex file from the attached code
example. Make sure programming mode is set to
Reset. Program the device.
6.
Remove the MiniProg from the ISSP connector.
7.
Press the Reset button.
www.cypress.com



2400-bps baud rate
125-mVp-p transmit amplitude (CENELEC compliant
when using the external circuitry on the CY3274). If
using the low-voltage PLC boards, then a 1.55-Vp-p
amplitude is recommended.
25-ms Transmit Delay (for ensuring a clean line
before signal transmission and to give the PLC device
time to wake up from listen mode)
Acknowledgment mode
Retry Count of 1
Document No. 001-54416 Rev. *H
23
Using CY8CPLC20 in Powerline Communication (PLC) Applications
Figure 32. PLC Low-Power Code Example
Figure 33. PLC Hardware Test Setup
Start
PC
with Cypress PLC Control
Panel GUI
Initialize all user
modules
USB-I2C
Bridge
LCD
Display
CY3274
CY3274
(Low Power)
Put PLT into low
power listen mode
120-240 VAC Powerline
Put device in sleep
mode for ~2 ms
(sleep timer
period)
Signal
detected?
Summary
N
No signal for
> 500 ms?
Y
Y
Put PLT in full
power RX mode
Start packet timer
for 300 ms
Decrease signal
detect threshold
Message
received?
N
Related Application Notes
N
Signal
lost for >1 ms
or packet timer
expired?
Y
Y
Increment
RX_Count and
display on LCD
False
trigger (time since
previous signal
<80ms)?
Y
Increase signal
detect threshold
www.cypress.com
The CY8CPLC20 device provides a flexible and easy-touse solution for developing a highly integrated PLC-based
system. With the flexibility of the PSoC core inside the
CY8CPLC20, this code example can be modified to add
additional
functionality
(for
example,
voltage
measurement, current measurement, motor control, and
so on) to create an intelligent end-user system.
N

AN60685 - PLC - Interfacing the Cypress Powerline
Communication Solution to CyFi Low-Power RF
Module


AN62792 - Updating Field Firmware with PLC

AN62769 - Encrypted Data Communication Using
Cypress PLC Solution

AN55427 - Cypress Powerline Communication Board
Design Analysis

AN58825 - PLC
Debugging Tools
AN62487 - Cypress Powerline Communication (PLC)
Repeater Implementation
-
Powerline
Communication
N
About the Author
Name:
Aditya Yadav
Title:
Applications Engineer
Document No. 001-54416 Rev. *H
24
Using CY8CPLC20 in Powerline Communication (PLC) Applications
Appendix A - BIU, TX, RX Interrupt Service Routines (Section of PLT_1INT.asm)
;----------------------------------------------------------------------------; FUNCTION NAME: _PLT_BIU_Active_ISR
;
; DESCRIPTION: Unless modified, this implements only a null handler stub.
;
This is not a true ISR, but is called when the Band In Use is active
;
;----------------------------------------------------------------------------;
_PLT_BIU_Active_ISR:
;@PSoC_UserCode_BIU_Active_BODY@ (Do not change this line.)
;--------------------------------------------------; Insert your custom code below this banner
;--------------------------------------------------;
NOTE: interrupt service routines must preserve
;
the values of the A and X CPU registers.
lcall _BIU_LED_On
;--------------------------------------------------; Insert your custom code above this banner
;--------------------------------------------------;@PSoC_UserCode_END@ (Do not change this line.)
ret
;----------------------------------------------------------------------------; FUNCTION NAME: _PLT_BIU_Complete_ISR
;
; DESCRIPTION: Unless modified, this implements only a null handler stub.
;
This is not a true ISR, but is called when the Band In Use is no longer set
;
;----------------------------------------------------------------------------;
_PLT_BIU_Complete_ISR:
;@PSoC_UserCode_BIU_Complete_BODY@ (Do not change this line.)
;--------------------------------------------------; Insert your custom code below this banner
;--------------------------------------------------;
NOTE: interrupt service routines must preserve
;
the values of the A and X CPU registers.
lcall _BIU_LED_Off
;--------------------------------------------------; Insert your custom code above this banner
;--------------------------------------------------;@PSoC_UserCode_END@ (Do not change this line.)
ret
www.cypress.com
Document No. 001-54416 Rev. *H
25
Using CY8CPLC20 in Powerline Communication (PLC) Applications
;----------------------------------------------------------------------------; FUNCTION NAME: _PLT_TX_Active_ISR
;
; DESCRIPTION: Unless modified, this implements only a null handler stub.
;
This is not a true ISR, but is called when the Transmitter is actively sending a
message
;
;----------------------------------------------------------------------------_PLT_TX_Active_ISR:
;@PSoC_UserCode_TX_Active_BODY@ (Do not change this line.)
;--------------------------------------------------; Insert your custom code below this banner
;--------------------------------------------------;
NOTE: interrupt service routines must preserve
;
the values of the A and X CPU registers.
lcall _TX_LED_On
;--------------------------------------------------; Insert your custom code above this banner
;--------------------------------------------------;@PSoC_UserCode_END@ (Do not change this line.)
ret
;----------------------------------------------------------------------------; FUNCTION NAME: _PLT_TX_Complete_ISR
;
; DESCRIPTION: Unless modified, this implements only a null handler stub.
;
This is not a true ISR, but is called when the Transmitter has completed sending the
message
;
;----------------------------------------------------------------------------;
_PLT_TX_Complete_ISR:
;@PSoC_UserCode_TX_Complete_BODY@ (Do not change this line.)
;--------------------------------------------------; Insert your custom code below this banner
;--------------------------------------------------;
NOTE: interrupt service routines must preserve
;
the values of the A and X CPU registers.
lcall _TX_LED_Off
;--------------------------------------------------; Insert your custom code above this banner
;--------------------------------------------------;@PSoC_UserCode_END@ (Do not change this line.)
ret
www.cypress.com
Document No. 001-54416 Rev. *H
26
Using CY8CPLC20 in Powerline Communication (PLC) Applications
;----------------------------------------------------------------------------; FUNCTION NAME: _PLT_RX_Active_ISR
;
; DESCRIPTION: Unless modified, this implements only a null handler stub.
;
This is not a true ISR, but is called when the Receiver is in process of receiving a
packet
;
;----------------------------------------------------------------------------;
_PLT_RX_Active_ISR:
;@PSoC_UserCode_RX_Active_BODY@ (Do not change this line.)
;--------------------------------------------------; Insert your custom code below this banner
;--------------------------------------------------;
NOTE: interrupt service routines must preserve
;
the values of the A and X CPU registers.
lcall _RX_LED_On
;--------------------------------------------------; Insert your custom code above this banner
;--------------------------------------------------;@PSoC_UserCode_END@ (Do not change this line.)
ret
;----------------------------------------------------------------------------; FUNCTION NAME: _PLT_RX_Complete_ISR
;
; DESCRIPTION: Unless modified, this implements only a null handler stub.
;
This is not a true ISR, but is called when the Receiver is no longer receiving a
packet
;
;----------------------------------------------------------------------------;
_PLT_RX_Complete_ISR:
;@PSoC_UserCode_RX_Complete_BODY@ (Do not change this line.)
;--------------------------------------------------; Insert your custom code below this banner
;--------------------------------------------------;
NOTE: interrupt service routines must preserve
;
the values of the A and X CPU registers.
lcall _RX_LED_Off
;--------------------------------------------------; Insert your custom code above this banner
;--------------------------------------------------;@PSoC_UserCode_END@ (Do not change this line.)
ret
www.cypress.com
Document No. 001-54416 Rev. *H
27
Using CY8CPLC20 in Powerline Communication (PLC) Applications
Document History
Document Title: Using CY8CPLC20 in Powerline Communication (PLC) Applications – AN54416
Document Number: 001-54416
Revision
ECN
Orig. of
Change
Submission
Date
Description of Change
**
2728604
FRE
07/02/09
New Spec.
*A
2751601
FRE
08/11/09
Updated code example with TX, RX, and BIU LEDs.
*B
2828349
FRE
12/15/09
Updated for PSoC Designer 5.0 SP6 Release
*C
3143567
FRE
01/20/2011
Updated for PSoC Designer 5.1 SP1 Release
Added analog voltage measurement to the transmitter code example
2
Added optional UART and I C interfaces to the transmitter code example
Added hardware evaluation procedure for example projects
Removed LED.asm modifications
*D
3623259
ADIY
05/21/2012
Updated template.
Updated for PSoC Designer 5.2 Release.
Combined the section s „PLT User Modules‟ and „Code Example‟ section in a
single section „Using PLT User Module in a Code Example‟.
Combined Transmitter and Receiver in a single project. Removed Voltage
measurement.
Made a separate project for Host interface.
Updated images and firmware for UART and I2C Host Interfaces.
Added section “Low Power Firmware”.
Added section “Estimating CY8CPLC20 Power Consumption”.
*E
4090968
ADIY
08/08/2013
Minor FW update in PLC_I2C_Host project.
Updated projects for PSoC Designer 5.4.
Updated Worldwide Sales and Design Support.
*F
4162892
ADIY
10/16/2013
Correct error in document history
*G
4402358
ROIT
06/09/2014
Removed Reference to CY3275 kit
Updated Figure 29 to reflect Designer 5.4
*H
4698464
SNVN
03/27/2015
Updated software version to PSoC Designer 5.4 CP1
Table 2. Average Power Consumption updated
Reference to CY3275 kit removed in Figure 33. PLC Hardware Test Setup
www.cypress.com
Document No. 001-54416 Rev. *H
28
Using CY8CPLC20 in Powerline Communication (PLC) Applications
Worldwide Sales and Design Support
Cypress maintains a worldwide network of offices, solution centers, manufacturer‟s representatives, and distributors. To find
the office closest to you, visit us at Cypress Locations.
PSoC® Solutions
Products
Automotive
cypress.com/go/automotive
psoc.cypress.com/solutions
Clocks & Buffers
cypress.com/go/clocks
PSoC 1 | PSoC 3 |PSoC4|PSoC 5LP
Interface
cypress.com/go/interface
Lighting & Power Control
cypress.com/go/powerpsoc
cypress.com/go/plc
Memory
cypress.com/go/memory
PSoC
cypress.com/go/psoc
Touch Sensing
cypress.com/go/touch
USB Controllers
cypress.com/go/usb
Wireless/RF
cypress.com/go/wireless
Cypress Developer Community
Community | Forums | Blogs | Video | Training
Technical Support
cypress.com/go/support
PSoCisa registered trademark of Cypress Semiconductor Corp. PSoC Designer is a trademark of Cypress Semiconductor Corp. All other trademarks or
registered trademarks referenced herein are the property of their respective owners.
Cypress Semiconductor
198 Champion Court
San Jose, CA 95134-1709
Phone
Fax
Website
: 408-943-2600
: 408-943-4730
: www.cypress.com
© Cypress Semiconductor Corporation, 2009-2015. The information contained herein is subject to change without notice. Cypress Semiconductor
Corporation assumes no responsibility for the use of any circuitry other than circuitry embodied in a Cypress product. Nor does it convey or imply any
license under patent or other rights. Cypress products are not warranted nor intended to be used for medical, life support, life saving, critical control or
safety applications, unless pursuant to an express written agreement with Cypress. Furthermore, Cypress does not authorize its products for use as
critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The
inclusion of Cypress products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies
Cypress against all charges.
This Source Code (software and/or firmware) is owned by Cypress Semiconductor Corporation (Cypress) and is protected by and subject to worldwide
patent protection (United States and foreign), United States copyright laws and international treaty provisions. Cypress hereby grants to licensee a
personal, non-exclusive, non-transferable license to copy, use, modify, create derivative works of, and compile the Cypress Source Code and derivative
works for the sole purpose of creating custom software and or firmware in support of licensee product to be used only in conjunction with a Cypress
integrated circuit as specified in the applicable agreement. Any reproduction, modification, translation, compilation, or representation of this Source
Code except as specified above is prohibited without the express written permission of Cypress.
Disclaimer: CYPRESS MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARD TO THIS MATERIAL, INCLUDING, BUT
NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Cypress reserves the
right to make changes without further notice to the materials described herein. Cypress does not assume any liability arising out of the application or
use of any product or circuit described herein. Cypress does not authorize its products for use as critical components in life-support systems where a
malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress‟ product in a life-support systems
application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress against all charges.
Use may be limited by and subject to the applicable Cypress software license agreement.
www.cypress.com
Document No. 001-54416 Rev. *H