Inductive sensors IWRM 06 Inductive distance measuring sensors sample drawing 46 ø 6,5 M8 x 1 general data sample picture mounting type quasi-flush measuring distance Sd 0 ... 2 mm resolution repeat accuracy < 0,001 mm (stat.) < 0,005 mm (dynam.) < 0,02 mm linearity error ± 100 µm temperature drift ± 5 % (Full Scale) electrical data response time (factory characteristic) < 0,7 ms voltage supply range +Vs 15 ... 30 VDC short circuit protection yes reverse polarity protection yes voltage output current consumption max. (no load) 25 mA output signal 0 ... 10 VDC load resistance > 1000 Ohm current output current consumption max. (no load) 35 mA output signal 0 ... 10 mA load resistance +Vs min. < 910 Ohm load resistance +Vs max. < 2400 Ohm mechanical data type cylindrical smooth housing material stainless steel dimension 6,5 mm ambient conditions operating temperature 10 ... +60 °C protection class IP 67 order reference output circuit housing length connection types IWRM 06I9501 current output 40 mm cable, 2 m connector M8 IWRM 06I9501/S35 current output 46 mm IWRM 06U9501 voltage output 40 mm cable, 2 m IWRM 06U9501/S35 voltage output 46 mm connector M8 1 www.baumer.com 24/5/2016