IRF ASA2812D/ES

PD-94540A
ASA28XXD SERIES
28V Input, Dual Output
HYBRID-HIGH RELIABILITY
DC/DC CONVERTER
Description
The ASA28XXD Series of DC/DC converters are high
reliability thick film hybrid converters that use flyback
topology operating at a nominal frequency of 550KHz.
High input to output isolation is achieved through the
use of transformers in the flyback power and feed back
circuits.
The advanced feedback design provides fast loop
response for superior line and load transient
characteristics and offers greater reliability than devices
incorporating optical feedback circuits.
This device is designed to meet MIL-STD-704 input
requirements offering full performance over a 16V to
40V input range. Output Power of up to 5W is available
for either balanced or unbalanced loads.
Connecting the inhibit pin (pin 5) to the input common
(pin 7) will cause the converter to shut down. It is
recommended that the inhibit pin be driven by an open
collector device capable of sinking at least 400µA. The
open circuit voltage of the inhibit pin is 11.5 ± 0.5V.
ASA
Features
Up To 5.0W Output Power
±5V, ±12V, ±15V Outputs
High Reliability
Wide Input Voltage Range -16V To 40V
Indefinite Short Circuit and Overload Protection
Popular Industry Standard Pin-Out
Military Screening
Parallel Seam Welded Package
No External Capacitors Required
Input Voltage Surge Protected to MIL-STD-704
Under Voltage Lockout
Standard Microcircuit Drawings Available
Manufactured in a facility fully qualified to MIL-PRF38534, these converters are fabricated utilizing DSCC
qualified processes. For available screening options,
refer to device screening table in the data sheet.
Variations in electrical, mechanical and screening can
be accommodated. Extensive computer simulation
using complex modeling enables rapid design
modification to be provided. Contact IR Santa Clara
with specific requirements.
www.irf.com
1
01/11/07
ASA28XXD Series
Specifications
Absolute Maximum Ratings
Input voltage
Power output
Soldering temperature
Operating case temperature
Storage case temperature
-0.5V to +50VDC Continous, 80V, 100 msec
Internally limited ( 6.5W typical )
300°C for 10 seconds
-55°C to +125°C
-65°C to +135°C
Conditions
-55° ≤ TC ≤+125°C
V IN = 28V dc ±5% C L = 0
unless otherwise specified
TEST
Output voltage
Output current
ASA2812D/XX
ASA2815D/XX
Min
Max
Min
Max
Min
Max
1
±4.95
±5.05
±11.88
±12.12
±14.85
±15.15
2, 3
±4.90
±5.10
±11.76
±12.24
±14.70
±15.30
VIN = 16, 28, and 40 V dc
either output
1, 2, 3
200
1000
84
333
67
267
mA
VIN = 16, 28 and 40 V dc
1, 2, 3
470
200
290
mV PP
VIN = 16, 28, and 40 V dc
1, 2, 3
50
50
50
mV
1, 2, 3
50
50
50
mV
20% to 80% load change
1, 2, 3
15
8.0
8.0
%
IOUT = 0
Pin 5 connected to pin 7
1, 2, 3
12
12
12
60
60
60
100
100
100
IOUT = 0
1, 2
3, 4
Output ripple voltage
Line regulation
ASA2805D/XX
4
Group A
Subgroups
Unit
V
IOUT = 0, 50%, 100% IMAX
4
Load regulation
VIN = 16, 28, and 40 V dc
IOUT = 0, 50%, 100% IMAX
5
Cross regulation
Input current
IOUT = 0 Pin5 open
3, 4
Input ripple current
Efficiency
IOUT = IMAX
4
Capacitive load
1, 3
70
71
71
2
66
68
68
Input to output or any pin to
case (except pin 8) at 500 V
dc, Tc = +25° C
1
100
100
100
No effect on dc performance,
total for both outputs
4
200
IOUT = IMAX
Isolation
6, 7
Power dissipation load fault
1, 2, 3
Overload
8
1, 2, 3
Short circuit
4
Switching frequency
Output response to step
transient load changes
IOUT = IMAX
4, 9
Recovery time, step
transient load changes
4, 9, 10
4, 5, 6
IOUT = 0 50% IMAX
IOUT = 50% 100% IMAX
step line changes
4, 7, 11
Recovery time transient step
line changes
4, 7, 10, 11
Turn on overshoot
4
4, 12
Load fault recovery
MΩ
200
µF
W
4.0
4.0
4.0
2.0
2.0
2.0
600
500
600
500
600
-400
+400
-400
+400
-400
+400
-800
+800
-800
+800
-800
+800
KHz
mV pk
100
100
100
2000
2000
2000
4, 5, 6
VIN =16 40Vdc,IOUT= IMAX
4, 5, 6
VIN=16 40Vdc, IOUT= IMAX
4, 5, 6
1200
IOUT = 0 and IMAX
4, 5, 6
IOUT = 0 and IMAX
7
mA PP
%
500
IOUT = 0 50% IMAX
Output response transient
Turn on delay
IOUT = 50% 100% IMAX
4, 5, 6
200
mA
-750
+750
- 750
+750
-750
µs
+750
mV pk
1200
1200
µs
600
600
600
mV pk
4, 5, 6
25
25
25
ms
4, 5, 6
25
25
25
ms
For Notes to Specifications, refer to page 3
2
www.irf.com
ASA28XXD Series
Notes to Specifications
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
Parameter guaranteed by line, load, and cross regulation tests.
Up to 80% of full power is available from either output provided the total output does not exceed 5W.
Bandwidth of DC to 20MHz is guaranteed by design. Tested for 20KHz to 2MHz.
Load current split equally between +V OUT and -VOUT .
1.0W load on output under test, 1.0W to 4.0W load change on other output.
Capacitive load may be any value from 0 to the maximum limit without compromising DC performance. A capacitive load in excess
of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry,
appearing as a short circuit during turn-on.
Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall
be guaranteed to the limits specified.
An overload is a condition with a load in excess of rated but less than that necessary to trigger the short circuit protection and is
the condition of maximum power dissipation.
Load step transition time between 2µs and 10µs.
Recovery time is measured from the initiation of the transient to where V OUT has returned to within ±1% of V OUT at 50% load.
Input step transition time between 2µs and 10µs.
Turn-on delay time measurements is for either a step application of power at the input or the removal of ground connection from
enable pin (pin 5) with power applied to the input.
Block Diagram
+Output
+Input
1
6
Output
Return
2
-Output
3
Error
Amplifier
Input
Return
Case
7
8
Inhibit
5
www.irf.com
Controller
3
ASA28XXD Series
Mechanical Outline
1.075
0.800
1
2
3
0.270
4
5
1.075
8
7
0.800
±.005
6
0.025 ± .003 Dia Pins
0.220
Pin Designation
Pin #
Designation
1
+ Output
2
Output Return
3
- Output
4
NC
5
Inhibit
6
+ Input
7
Input Return
8
Case Ground
Standard Microcircuit Drawing Equivalence Table
Standard Microcircuit
Drawing Number
4
IR Standard
Part Number
5962-94649
ASA2815D
5962-95648
ASA2812D
www.irf.com
ASA28XXD Series
Device Screening
Requirement
MIL-STD-883 Method
ES HB
CH
-20°C to +85°C -55°C to +125°C -55°C to +125°C -55°C to +125°C
Temperature Range
Element Evaluation
No Suffix
MIL-PRF-38534
N/A
N/A
N/A
Class H
2023
N/A
N/A
N/A
N/A
2017
Yes
Yes
Yes
Non-Destructive
Bond Pull
Internal Visual
Temperature Cycle
1010
N/A
Cond B
Cond C
Cond C
Constant Acceleration
2001, Y1 Axis
N/A
500 Gs
3000 Gs
3000 Gs
N/A
N/A
PIND
2020
N/A
N/A
Burn-In
1015
N/A
48 hrs@hi temp
Final Electrical
MIL-PRF-38534
25°C
25°C 160 hrs@125°C 160 hrs@125°C
-55°C, +25°C,
-55°C, +25°C,
( Group A )
& Specification
+125°C
+125°C
PDA
MIL-PRF-38534
N/A
N/A
N/A
10%
Seal, Fine and Gross
1014
Cond A
Cond A, C
Cond A, C
Cond A, C
Radiographic
2012
N/A
N/A
N/A
N/A
External Visual
2009
Yes
Yes
Yes
Notes:
Best commercial practice
Sample tests at low and high temperatures
-55°C to +105°C for AHE, ATO, ATW
Part Numbering
ASA 28 05 D /CH
Model
Screening Level
Input Voltage
No Suffix, ES, HB, CH
28 = 28V
Output Voltage
05 = ±5V
12 = ±12V
15 = ±15V
(Please refer to Screening Table)
Output
D = Dual
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105
IR SANTA CLARA: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice. 01/2007
www.irf.com
5