data sheet - family

Inductive sensors
IWRM 30 (dist. 5...10 mm)
Inductive distance measuring
sensors
sample drawing
50
60
M30 x 1,5
SW 36
general data
sample picture
mounting type
flush
measuring speed
< 1,5 mm / ms
repeat accuracy
< 0,02 mm
temperature coefficient
1 µm / (K mm)
electrical data
voltage supply range +Vs
15 ... 30 VDC
residual output ripple
< 0,5 % Vs
short circuit protection
yes
reverse polarity protection
yes
voltage output
current consumption max. (no load)
20 mA
output signal
1 ... 9 VDC
load resistance
> 1000 Ohm
current output
current consumption max. (no load)
35 mA
output signal
4 ... 20 mA
load resistance +Vs min.
< 500 Ohm
load resistance +Vs max.
< 1000 Ohm
mechanical data
type
cylindrical threaded
housing material
brass nickel plated
dimension
30 mm
housing length
60 mm
connection types
cable, 2 m
ambient conditions
operating temperature
0 ... +60 °C
protection class
IP 67
order reference
measuring distance Sd
reference distance
output circuit
linearity error
IWRM 30I9501
5 ... 10 mm
7,1 ... 7,9 mm
current output
± 200 µm
IWRM 30U9501
5 ... 10 mm
7,1 ... 7,9 mm
voltage output
± 200 µm
IWRM 30U9502
5 ... 9 mm
6,7 ... 7,3 mm
voltage output
± 150 µm
1
www.baumer.com
24/5/2016