Photoelectric sensors FADR 14U4470/S14/IO Distance sensors dimension drawing 19,6 34,3 LED 4,5 4,2 15,4 * 17,7 11 4,5 29,8 51 61,8 REF 5,8 M12 x 1 10,2 20 10,9 * emitter axis general data photo measuring distance Sd 50 ... 400 mm special type Washdown design adjustment IO-Link Teach-in range min. > 20 mm power on indication LED green soiled lens indicator LED red resolution 0,1 ... 1 mm linearity error ± 1,5 ... ± 4 mm light source pulsed point source LED wave length 660 nm beam type point beam diameter 8 mm temperature drift < 0,1 % Sde/K approvals/certificates Ecolab connection diagram electrical data response time / release time < 3 ms BN (1) voltage supply range +Vs 14 ... 26 VDC WH (2) current consumption max. (no load) 80 mA output circuit analog output signal 0 ... 10 VDC load resistance (analog U) > 100 kOhm output current < 100 mA alarm output push-pull short circuit protection yes reverse polarity protection yes, Vs to GND Analog BK (4) BU (3) +Vs analog 0...10 V alarm (I/O-Link) 0V mechanical data width / diameter 19,6 mm height / length 51 mm depth 34,3 mm type rectangular housing material stainless steel 1.4404 (V4A); LSR IO-Link: Measuring range limit, average determination, service status, alarm output, switching window front (optics) PMMA LSR = Liquid Silicon Rubber connection types connector M12 FADR 14U4470/S14/IO Sensor FDA compliant and Ecolab approved www.baumer.com 7/1/2014 Photoelectric sensors FADR 14U4470/S14/IO Distance sensors ambient conditions operating temperature 0 ... +50 °C protection class IP 68/69K & proTect+ FADR 14U4470/S14/IO www.baumer.com 7/1/2014