EN

Photoelectric sensors
FADR 14U4470/S14/IO
Distance sensors
dimension drawing
19,6
34,3
LED
4,5
4,2
15,4
* 17,7
11
4,5
29,8
51
61,8
REF
5,8
M12 x 1
10,2
20
10,9
* emitter axis
general data
photo
measuring distance Sd
50 ... 400 mm
special type
Washdown design
adjustment
IO-Link
Teach-in range min.
> 20 mm
power on indication
LED green
soiled lens indicator
LED red
resolution
0,1 ... 1 mm
linearity error
± 1,5 ... ± 4 mm
light source
pulsed point source LED
wave length
660 nm
beam type
point
beam diameter
8 mm
temperature drift
< 0,1 % Sde/K
approvals/certificates
Ecolab
connection diagram
electrical data
response time / release time
< 3 ms
BN (1)
voltage supply range +Vs
14 ... 26 VDC
WH (2)
current consumption max. (no load)
80 mA
output circuit
analog
output signal
0 ... 10 VDC
load resistance (analog U)
> 100 kOhm
output current
< 100 mA
alarm output
push-pull
short circuit protection
yes
reverse polarity protection
yes, Vs to GND
Analog
BK (4)
BU (3)
+Vs
analog
0...10 V
alarm
(I/O-Link)
0V
mechanical data
width / diameter
19,6 mm
height / length
51 mm
depth
34,3 mm
type
rectangular
housing material
stainless steel 1.4404 (V4A); LSR
IO-Link: Measuring range limit, average
determination, service status, alarm
output, switching window
front (optics)
PMMA
LSR = Liquid Silicon Rubber
connection types
connector M12
FADR 14U4470/S14/IO
Sensor FDA compliant and Ecolab
approved
www.baumer.com
7/1/2014
Photoelectric sensors
FADR 14U4470/S14/IO
Distance sensors
ambient conditions
operating temperature
0 ... +50 °C
protection class
IP 68/69K & proTect+
FADR 14U4470/S14/IO
www.baumer.com
7/1/2014