DEMO CIRCUIT 1454A LTC3601 QUICK START GUIDE LTC3601 1.5A, 15V, MONOLITHIC SYNCHRONOUS STEP-DOWN REGULATOR DESCRIPTION Demonstration circuit 1454 is a step-down converter, using the LTC3601 monolithic synchronous buck regulator. The DC1454A has a maximum input voltage 15V, and is capable of delivering up to 1.5A of output current at a minimum input voltage of 4V. The output voltage of the DC1454A can be set as low as 0.6V, the reference voltage of the LTC3601. At low load currents, the DC1454A operates in discontinuous mode, and during shutdown, it consumes less than 40 uA of quiescent current. In continuous mode operation, the DC1454A is a high efficiency circuit - over 80%. The DC1454A can track another voltage with the LTC3601 track function. Because of the high switching frequency of the LTC3601, which is programmable up to 4 MHz, the DC1454A uses low profile surface mount components. All these features make the DC1454A an ideal circuit for use in Lithium-Ion Battery applications and distributed power systems. Gerber files for this circuit are available. Call the LTC Factory. Design files for this circuit board are available. Call the LTC factory. As Shipped Performance Summary PARAMETER CONDITIONS VALUE Minimum Input Voltage 4V Maximum Input Voltage 15V GND = Shutdown Run/Shutdown VIN = 4V to 15V, IOUT = 0A to 1.5A VIN = Run 1.2V ±4% (1.152V – 1.248V) VIN = 4V to 15V, IOUT = 0A to 1.5A 1.8V ±4% (1.728V – 1.872V) VIN = 4.5V to 15V, IOUT = 0A to 1.5A 3.3V ±4% (3.168V – 3.432V) Typical Output Ripple Voltage VIN = 12V, VOUT = 1.8V, IOUT = 1.5A (20 MHz BW) < 20mVP–P Burst Mode VIN = 12V, VOUT = 1.8V < 400 mA Nominal Switching Frequency RT = 324k 1 MHz ± 20% Output Voltage Regulation Table 1. Jumper Description JUMPER FUNCTION JP1 Vout Setting. JP5 Tracking or Soft-Start (SS) JP6 Mode: Forced Continuous Mode (FCM), Burst Mode, or External Synchronization (SYNC) JP7 Run JP8 Frequency JP9 ITH: Compensation RANGE/SETTING (DEFAULT) 1.2V (SS) - TRACK (FCM) – SYNC – Burst Mode (ON) - OFF (1 MHz) - 2 MHz INT – (EXT) 1 LTC3601 QUICK START PROCEDURE Vary the input voltage from 4V to 15V and adjust the load current from 0 to 1.5A. Vout should set the input voltage to 15V and the output current to 1.5A. Measure the output ripple voltage; it should measure less than 20 mVAC. Demonstration Circuit 1454 is easy to set up to evaluate the performance of the LTC3601. For proper measurement equipment configuration, set up the circuit according to the diagram in Figure 1. Before proceeding to test, insert shunts into the 1.2V position of the output voltage header JP1, into the SS (soft-start) position of Track/SS header JP5, into the FCM (Forced Continuous Mode) position of MODE header JP6, into the OFF position of RUN header JP7, into the 1 MHz position of FREQ header JP8, and into the EXT position of ITH header JP9. Observe the voltage waveform at the switch pins (the other side of the inductor from the output). Verify the switching frequency is between 800 kHz and 1.2 MHz (T = 1.25 us and 0.833 us), and that the switch node waveform is rectangular in shape. When measuring the input or output voltage ripple, care must be taken to avoid a long ground lead on the oscilloscope probe. Measure the input or output voltage ripple by touching the probe tip directly across the Vin or Vout and GND terminals. See Figure 2 for proper scope probe measurement technique. Change the JP6 shunt from forced continuous mode to Burst Mode. Also set the input voltage to 12V and the output current to any current less than 400 mA. Observe the discontinuous mode of operation at the switch node, and measure the output ripple voltage. It should measure less than 150 mV. With the DC1454 set up according to the proper measurement configuration and equipment in Figure 1, apply 6.3V at Vin (Do not hot-plug Vin or increase Vin over the rated maximum supply voltage of 15V, or the part may be damaged.). Measure Vout; it should read 0V. Turn on the circuit by inserting the shunt in header JP7 into the ON position. The output voltage should be regulating. Measure Vout - it should measure 1.2V +/- 2% (1.176V to 1.224V). Insert the JP7 shunt into the OFF position and move the shunt in the 1.2V output JP1 header into any of the two remaining output voltage option headers: 1.8V (JP2) or 3.3V (JP3). Just as in the 1.2V Vout test, the output voltage should read Vout +/- 2% tolerance under static line and load conditions and +/- 1% tolerance under dynamic line and load conditions (+/- 2% total). Also, the circuit operation in discontinuous mode will be the same. When finished, turn off the circuit by inserting the shunt in header JP7 into the OFF position. 2 LTC3601 Figure 1. Proper Equipment Measurement Set-Up Figure 2. Measuring Input or Output Ripple 3 LTC3601 Normal Switching Frequency & Output Ripple Voltage Waveforms Figure 3. Switch Node & Output Ripple Voltage Waveforms VIN = 12V, VOUT = 1.8V, IOUT = 1.5A, FSW = 2 MHz Trace 2: Output Ripple Voltage (20 mV/div AC) Trace 1: Switch Voltage (10 V/div) 4 LTC3601 Load Step Response Waveform Figure 4. Load Step Response VIN = 12V, VOUT = 1.8V, 1.5A Load Step (0A <-> 1.5A) Forced Continuous Mode FSW = 2 MHz Trace 3: Output Voltage (50mV/div AC) Trace 4: Output Current (0.5A/div) 5 LTC3601 6