PZU15BL NXP Product Reliability

Product Reliability
Reliability Investigation Results for Product Type PZU15BL
Time period:
Q4/2013 to Q3/2014
Test Results
AEC-Q101 Test
Conditions
Duration
Quantity
Rejects
all parts
see below
8650
0
#1
TEST
Pre- and Post-Stress
Electrical Test
Tamb = 25 °C
N/A
#2
PC
Preconditioning
JESD22-A113
Bake Tamb = 125 °C
Soak Tamb = 85 °C, RH = 85%
Reflow soldering
24 hours
168 hours
3 cycles
#5
HTRB
High Temperature Reverse
Bias
JESD22-A108
Tj = Tjmax, VR > 80% of max. breakdown
voltage
1000 hours
5760
0
#7
TC
Temperature Cycling
JESD22-A104
-55 °C to Tjmax
1000 cycles
2320
0
#8
AC
Autoclave
JESD22-A102
Tamb = 121 °C, RH = 100 %
Pressure = 205 kPa (29.7 psia)
96 hours
2090
0
#9
H3TRB
High Humidity High
Temperature Reverse Bias
JESD22-A101
Tamb = 85 °C, RH = 85%, VR > 80 % of
rated breakdown voltage
1000 hours
2320
0
# 10
IOL
Intermittent Operating Life
MIL-STD-750 Method 1037
ton = toff, devices powered to insure
ΔTj = 125 °C for 7500 cycles or
ΔTj = 100 °C for 15000 cycles
1000 hours
1920
0
# 20
RSH
Resistance to Solder Heat
JESD22-A111 / JESD22-B106
260 °C ± 5 °C
10 s
570
0
# 21
SD
Solderability
J-STD-002
245 °C ± 5 °C
3s
570
0
Calculation of FIT and MTBF
Test considered for FIT calculation: High Temperature Reverse Bias (HTRB, AEC-Q101 Test # 5)
Confidence level 60%, derated to 55 °C, activation energy 0.7 eV, test time 168 to 1000 hours
Wafer Fab
Technology
Quantity
Rejects
Failure Rate
MTBF
NXP DHAM
Zener / Protection
5760
0
0.74 FIT
154731 years
www.nxp.com
© 2015 NXP Semiconductors N.V.
All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this
document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be
accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent – or other industrial or
intellectual property rights.