ENGINEERING TEST REPORT NUMBER: 10215290EICES1 ON Model No.(s): MB-PRO-MVK, MCU-430F5438A-MVK, AFE-BREAKOUT-MVK, RF-BREAKOUT-MVK, & RF-TCA8418-MVK IN ACCORDANCE WITH: ICES-003, ISSUE 4: 2004 TESTED FOR: Texas Instruments, Inc. 12500 TI Boulevard, M/S 8669 Dallas TX, 75243 TESTED BY: Nemko USA, Inc. 802 N. Kealy Lewisville, Texas 75057-3136 Total Pages 20 Nemko USA, Inc. authorizes the above named company to reproduce this report provided it is reproduced in its entirety, for use by the company’s employees only. This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Nemko USA, Inc. is a NVLAP accredited laboratory. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko USA, Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. This report applies only to the items tested. APPROVED BY: Art Ruvalcaba EMC Engineer TESTED BY: DATE: DATE: Brian Boyea, EMC Engineer 3-Nov-2011 19-Oct-2011 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Table of Contents Section 1. Summary of Test Results ................................................................ 3 Section 2. Equipment Under Test (E.U.T.) ....................................................... 4 Section 3. Equipment Configuration ................................................................. 6 Section 4. Conducted Emissions (Mains ports) ................................................ 8 Section 5. Radiated Emissions ....................................................................... 13 Section 6. Test Methods and Block Diagrams. .............................................. 18 Page 2 of 20 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Section 1. Summary of Test Results General: All measurements are traceable to national standards. These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with ICES-003, Issue 4 February, 2004, Class B, Interference-Causing Equipment Standard, Digital Apparatus in accordance with the measurement method described in: Canadian Standards Association Standard CAN/CSA-CEI/IEC CISPR 22-02 “Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment” Frequencies were initially identified in a semi-anechoic chamber. Amplitude measurements were made in a semi-anechoic chamber. Details of the chamber are on file with the FCC and Industry Canada. Abstract: Emissions: Name of Test Conducted Emissions (Mains port) Radiated Emissions Basic Standard ICES-003, Issue 4 February, 2004 ICES-003, Issue 4 February, 2004 Results Complies Complies THE FOLLOWING DEVIATIONS FROM, ADDITIONS TO, OR EXCLUSIONS FROM THE TEST SPECIFICATIONS HAVE BEEN MADE: NONE Page 3 of 20 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Section 2. Equipment Under Test (E.U.T.) Manufacturer: Texas Instruments, Inc. Name: Development Evaluation Modules Model Number: MB-PRO-MVK, MCU-430F5438A-MVK, AFE-BREAKOUT-MVK, RF-BREAKOUT-MVK, & RF-TCA8418-MVK Serial Number: None Part Number: MB-PRO-MVK, MCU-430F5438A-MVK, AFE-BREAKOUT-MVK, RF-BREAKOUT-MVK, & RF-TCA8418-MVK Production Status: Production E.U.T. Arrival Date: 10/19/11 Description of E.U.T.: Development Evaluation Modules Clock, Oscillator, Highest Frequencies Utilized: 25.0 MHz Modifications Incorporated in E.U.T. The E.U.T. has not been modified from what is described by the brand name and unique type identification stated above. Justification: The E.U.T. was configured for testing as per typical installation. Position and bundling of cables were investigated to establish maximum amplitude of emissions. Exercise Program: The E.U.T. exercise program used during radiated and conducted testing was designed to exercise the various system components in a manner similar to typical use. The EUT was in the following exercise mode: Powered on running. Page 4 of 20 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ E.U.T. Photographs: Page 5 of 20 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Section 3. Equipment Configuration Date: 10/19/2011 Company: T.I. NEMKO USE ONLY 10215290 JOB # EQUIPMENT CONFIGURATION LIST (HARDWARE/PERIPHERALS): Place an "*" next to EUT and any item that is part of the EUT. Item (A) (B) (C) (D) (E) (F) (G) (H) (I) (J) (K) (L) (M) * * Generic Description Evaluation Module Laptop PowerSupply ¹ FCC ID STATUS 1. FCC DOC 2. FCC A/B Verification Manufacturer T.I. Dell Dell Model No. TMDSDOCK28027 Latitude D610 HA65NS0-00 Serial # Rev. FCC ID Status¹ 20618812117 3. None - (If performing FCC testing, contact lab manager) 4. Certification (include FCC ID in parenthesis) INTER-CONNECTION CABLES: Place an "*" next to EUT and any item that is part of the EUT. Cable Type Item * (1) * USB (2) * Power Supply (3) Manufacturer Generic T.I. EVM TMDSDOCK28343 Page 6 of 20 Ln (m) Term² Shield 1 1 Qty. 1 1 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Client Name: T.I. Work Order #: 10215290 Model Number: Date: Test Configuration: 10/196/11 Powered on Transmitting AC 2 B A 1 C Page 7 of 20 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Section 4. Conducted Emissions (Mains ports) Purpose: The test is intended to demonstrate the compliance of the Equipment Under Test (E.U.T.) to the limits for conducted emissions as defined by ICES-003, Issue 4, February 2004, Class B, in accordance with the measurement method described in: Canadian Standards Association Standard CAN/CSA-CEI/IEC CISPR 22-02. Specification Limits: Limits for conducted disturbance at the mains ports Frequency Range (MHz) Quasi-peak Limits (dBuV) 0.15 to 0.50 66-56 0.50 to 5.00 56 5.00 to 30.00 60 Average Limits (dBuV) 56-46 46 50 Method of Measurement (Procedure CISPR 22): Measurements were made using a spectrum analyzer with 10 kHz RBW, Peak detector. Any emissions that are close to the limit are measured using a test receiver with 9 kHz bandwidth, CISPR Quasi-Peak detector. Test Method: See Section 6. Page 8 of 20 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Test #: CEPV-01 Tested By: Brian Boyea Date of Tests: 10/19/11 Test Conditions: Test Voltage: 120 Vac Temperature: 25˚C Humidity: 45% Test Results: The E.U.T. complies. TEST EQUIPMENT Asset Tag Description Manufacturer Model Serial # Last Cal Next Cal 674 704 Limiter Filter, High Pass, 5KHz 0.5m Cable Assy LISN .15mhz30mhz Spectrum Analyzer Cable, Coaxial Hewlett Packard Solar Electronics Nemko USA 11947A 7930-5.0 3107A02200 933126 26-Oct-2010 29-Sep-2010 26-Oct-2011 29-Sep-2011 25-Feb-2011 25-Feb-2012 EMCO 3825/2 1305 25-Oct-2010 25-Oct-2011 Rohde & Schwartz Nemko USA, Inc. FSP3 100073 2-Sept-2011 2-Sept-2013 03-Nov-2010 03-Nov-2011 749 1258 1663 1988 RG213 Page 9 of 20 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Test Data –Conducted Emissions, Power Lines Test#CEPV-01 Line 1 Nemko FCC B Conducted Emissions Line 1 Peaks Operator: Brian Frequency Peaks MHz 0.152 0.161 0.169 0.177 0.185 0.194 0.203 0.228 0.278 0.525 48.90 47.48 45.99 46.88 47.09 39.50 42.96 40.49 39.39 40.19 FCC B FCC B Avg QP AVG QP Limit Limit Margin Margin 55.95 65.95 -7.05 -17.05 55.70 65.70 -8.22 -18.22 55.47 65.47 -9.48 -19.48 55.22 65.22 -8.34 -18.34 54.99 64.99 -7.89 -17.89 54.76 64.76 -15.25 -25.25 54.49 64.49 -11.53 -21.53 53.76 63.76 -13.27 -23.27 52.34 62.34 -12.95 -22.95 46.00 56.00 -5.81 -15.81 Page 10 of 20 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Line 2 FCC B Conducted Emissions Nemko Line 2 Peaks Operator: Brian Frequency Peaks MHz 0.151 0.159 0.167 0.175 0.184 0.192 0.203 0.211 0.228 0.517 41.55 39.94 42.85 41.13 41.57 40.99 38.92 39.14 37.26 37.38 FCC B FCC B Avg QP AVG QP Limit Limit Margin Margin 55.98 65.98 -14.43 -24.43 55.75 65.75 -15.81 -25.81 55.50 65.50 -12.65 -22.65 55.27 65.27 -14.15 -24.15 55.02 65.02 -13.46 -23.46 54.79 64.79 -13.80 -23.80 54.49 64.49 -15.57 -25.57 54.26 64.26 -15.12 -25.12 53.78 63.78 -16.52 -26.52 46.00 56.00 -8.62 -18.62 Page 11 of 20 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Test Photographs - Test # Page 12 of 20 CEPV-01 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Section 5. Radiated Emissions Purpose: The test is intended to demonstrate the compliance of the Equipment Under Test (E.U.T.) to the limits for radiated emissions as defined by ICES-003, Issue 4 February, 2004, Class B, in accordance with the measurement method described in: Canadian Standards Association Standard CAN/CSA-CEI/IEC CISPR 22-02. Specification Limits: Limits for radiated disturbance of Class B Frequency Range (MHz) 30-230 230-1000 3m Limits (dBuV) 40.0 47.0 Test Method: See Section 6. Page 13 of 20 10m Limits (dBuV) 30.0 37.0 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Test #: REHE-01 Tested By: Brian Boyea Date of Tests: 10/19/11 Test Conditions: Test Voltage: 120 Vac Temperature: 25˚C Humidity: 45% Test Results: The E.U.T. complies. TEST EQUIPMENT Asset Description Manufacturer Model Tag Serial # Last Cal Next Cal 1 1016 1025 1304 1763 1767 1783 3m SemiAnechoic Chamber Preamplifier Preamplifier, 25dB Antenna, Horn Antenna, Bilog Receiver, EMI Test 20Hz - 26.5 GHz - 150 - +30 dBm LCD Cable Assy, 3m Chamber Nemko USA, Inc. Chamber 1 26-Sept-2011 26-Sept-2012 Hewlett Packard Nemko USA, Inc. 8449A LNA25 2749A00159 399 20-July-2011 23-Feb-2011 20-July-2012 23-Feb-2012 Electro Metrics Schaffner Rohde & Schwartz RGA-60 CBL 6111D ESIB26 6151 22926 837491/0002 24-Nov-2010 11-Feb-2011 01-Dec-2010 24-Nov-2012 11-Feb-2012 01-Dec-2011 Nemko Chamber 26-Sept-2011 26-Sept-2012 Page 14 of 20 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Test Data – Radiated Emissions, Electric Field, Test# REHE-01 Horizontal Nem ko Scan MB-PRO-MVK Rev F, MCU-430F5438A-MVK FCC B Li mi t AFE-Breakout-MVK FCC Cla s s B 3 0 M Hz -1 GHz Scan Peaks RF-Breakout-MVK, RF-TCA8418-MVK Horizontal Scan Peaks 8 0 .0 7 0 .0 L i m i t L evel ( d B u V / m ) 6 0 .0 5 0 .0 4 0 .0 3 0 .0 2 0 .0 1 0 .0 0 3 0 .0 M 2 3 0 .0 M 4 3 0 .0 M 6 3 0 .0 M 8 3 0 .0 M Frequency (Hz) Operator: Brian Model Number: MB-PRO-MVK Rev F 06:41:36 AM, Thursday, October 27, 2011 Company: TI Vertical Nem ko Scan M B-PRO-M VK Re v F, M CU-4 3 0 F5 4 3 8 A-M VK FCC B Li mi t AFE-Bre a k out-M VK FCC Cla s s B 3 0 M Hz -1 GHz Scan Peaks RF-Bre a k out-M VK, RF-TCA8 4 1 8 -M VK Ve rtic a l Sc a n Peaks 80. 0 70. 0 A mp l i t u d e ( d b u V / m) 60. 0 50. 0 40. 0 30. 0 20. 0 10. 0 0 30. 0M 230. 0M 430. 0M 630. 0M 830. 0M Fre que nc y Ope ra tor: Bria n M ode l Num be r: M B-PRO-M VK Re v F 0 6 :4 1 :3 4 AM , Thurs da y , Oc tobe r 2 7 , 2 0 1 1 Com pa ny : TI Page 15 of 20 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Nemko, Lewisville, TX FCC 3 Meter Chamber Final Quasi Peak Measurements Operator: Brian Frequency Limit Horizontal QP Vertical Vertical MHz QP Margin QP Margin 60.00 40.00 24.84 -15.16 96.01 43.50 32.06 -11.44 108.86 43.50 30.76 -12.75 147.78 43.50 30.99 -12.51 218.76 47.00 17.22 -29.79 232.67 47.00 28.68 -18.32 400.96 47.00 13.34 -33.66 500.03 47.00 20.13 -26.87 800.01 47.00 31.70 -15.30 27.77 -19.23 837.86 47.00 15.48 -31.52 871.63 47.00 27.52 -19.48 899.95 47.00 29.96 -17.04 900.01 47.00 34.24 -12.76 996.38 54.00 26.33 -27.67 MB-PRO-MVK Rev F, MCU-430F5438A-MVK AFE-Breakout-MVK, RF-Breakout-MVK, RF-TCA8418-MVK 30 MHz to 1GHz was the spectrum searched. RBW = 120kHz VBW = 120kHz Page 16 of 20 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Test Photos Page 17 of 20 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Section 6 Test Methods and Block Diagrams. Conducted Emissions (Mains Ports) Applicable Test Standard: CFR 47, FCC Pt 15, Subpart B The test set-up is as per the test configuration diagram. The E.U.T. is configured as typically used. The E.U.T. and any accessories are operated with typical load conditions. Conducted power line measurements are made from 150 kHz to 30 MHz. For each current carrying conductor of each power cord associated with the E.U.T., the emission closest to the limit is recorded. Initial measurements are made using a spectrum analyzer with 10 kHz RBW, peak detector. If emissions are below the Average limit, the unit is deemed to be compliant. Any emissions within 6dB of the quasi peak limit are measured using a test receiver with 9 kHz bandwidth, CISPR quasi-peak detector. Bandwidths used on the test receiver are those specified in CISPR 16-1. Test Configuration - Power line Conducted Emissions: EUT Line Impedance Stabilization Network (L.I.S.N.) Spectrum Analyzer or Test Receiver Page 18 of 20 AC Power Source ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Radiated Emissions Test Method: Applicable Test Standard: CISPR 22: 2006 for Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement. The test set-up in the semi-anechoic chamber is as per the test configuration diagram. The E.U.T. is configured as typically used. The equipment was tested for radiated emissions from 30 MHz to 1000 MHz in accordance with the requirements of ICES-003. Equipment with oscillator frequencies above 108 MHz were tested to the fifth harmonic or in accordance with the requirements of CAN/CSA-CEI/IEC CISPR 22-02. Details of the chamber are on file with the FCC and Industry Canada. Variations in antenna height, antenna polarization, and E.U.T. azimuth are explored to produce the emission that has the highest amplitude relative to the limit. If less than six emissions are better than 20 dB below the limit, the noise level of the measuring instrument at representative frequencies is also reported. Page 19 of 20 ICES-003, ISSUE 4: 2004, CLASS B INFORMATION TECHNOLOGY EQUIPMENT REPORT NO.10215290EICES1 EQUIPMENT: EVM Units ______________________________________________________________________________________ Test Configuration - Radiated Emissions Radiated Pre-scan: ANTENNA E.U.T. SPECTRUM ANALYZER AND PLOTTER OR TEST RECEIVER Semi-Anechoic Chamber SHIELDED ROOM COMPUTER Page 20 of 20