PESD15VS4UD NXP Product Reliability

Reliability Investigation Results, Type: PESD15VS4UD
Time period Q4/2012 to Q3/2013
AEC Q101 Test
Conditions
Duration
Quantity
Rejects
all parts
see
below
41480
0
#1
TEST
Pre- and Post-Stress
Electrical Test
Ta = 25 °C
N/A
#2
PC
Preconditioning
JESD22 -A113
Bake Ta = 125 °C
Soak Ta = 85 °C, RH = 85%
Reflow soldering
24 hours
168 hours
3 cycles
#5
#7
HTRB
High Temperature
Reverse Bias
TC
Temperature Cycling
JESD22 -A108
Tj = Tjmax, Vr > 80% of max.
breakdown Voltage
1000 hours
5840
0
JESD22- A104
-55 °C to Tjmax
1000 cycles
11040
0
#8
AC
Autoclave
JESD22- A102
Ta = 121 °C, RH = 100 %
Pressure = 205 kPa (29.7 psia)
96 hours
11040
0
#9
H3TRB
High Humidity High
Temperature Reverse
Bias
JESD22- A101
Ta = 85 °C, 85% RH, Vr > 80% of
rated breakdown voltage
1000 hours
11040
0
# 10
IOL
Intermittent Operating Life
MIL-STD-750 Method 1037
ton = toff, Devices powered to insure
ΔTj = 125 °C for 7500 cycles or
ΔTj = 100 °C for 15000 cycles
1000 hours
8720
0
JESD22-A111 / JESD22- B106
260 °C ± 5 °C
10 s
2700
0
J-STD-002
245 °C ± 5 °C
3s
3330
0
# 20
# 21
RSH
Resistance to Solder Heat
SD
Solderability
Calculation of FIT and MTBF
Test considered for FIT calculation: High Temp. Reverse Bias (HTRB, AEC Q101 Test # 5)
Confidence level 60%, derated to 55 °C, activation energy 0.7 eV, test time 168-1000 hours
Wafer Fab
Technology
Quantity
Rejects
Failure Rate
MTBF
NXP DHAM
Zener / Protection
5840
0
0.73 FIT
156880 years
© 2014 NXP Semiconductors N.V.
All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The
information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and
may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof
does not convey nor imply any license under patent- or other industrial or intellectual property rights. Date of release: Jun 2014