EN

Photoelectric sensors
FLDM 170G1011/S42
Copy counters
dimension drawing
70
64
30
17
158
M16 x 0,75
Display and
keypad
47°
Laser
beam
Interface
connector
Main
connector
68
35 23,5
6
M6
ø 6,4
170
13
12
general data
photo
measuring distance Sd
0 ... 90 mm
optimum operating distance
70 mm
counting rate
< 3000000 copies/h
object speed
5 m/sec
object cycle distance
> 1 mm
sensitivity
single sheet/edge thickness 0,1 mm
sync. input
yes
measuring point
visible red laser line 6 mm
light source
pulsed red laser diode
wave length
670 nm
laser class
2
edge indicator
LED yellow
power on indication
LED green
false pulse suppression
4 program options
direct gap detection
yes
sensitivity adjustment
4 preset levels or level set by customer
connection diagram
electrical data
voltage supply range +Vs
10 ... 30 VDC
current consumption max. (no load)
230 mA
output circuit
push-pull
output pulse length
0,3 ... 100 ms selectable
short circuit protection
yes
reverse polarity protection
yes
interface
serial for ScaDiag software
200mA 10 Ω
polyfuse
(3)
+VS
(1)
output
(6)
ground
laser warning
LASER RADIATION
DO NOT STARE INTO BEAM
Wavelength: 620...680nm
Max. av. Output: < 1mW
IEC 60825-1, Ed. 2, 2007
CLASS 2 LASER PRODUCT
mechanical data
width / diameter
30 mm
type
rectangular
housing material
die-cast zinc
connector base (main connector)
DIN 45322, 6 pin
connector base (interface)
DIN 45326, 8 pin
front (optics)
glass
Complies with 21 CFR 1040.10 and 1040.11 except for deviations
pursuant to laser notice No. 50, dated June 24, 2007
A software package called ScaDiag allows
to control all functions and settings.
ambient conditions
operating temperature
0 ... +50 °C
protection class
IP 54
FLDM 170G1011/S42
Also the software allows to record
and display measurement sequences
speeding up troubleshooting.
www.baumer.com