Energy Labeling Information(AC product) According to Commission Regulation (EU) No 626/2011 Supplier's name - Samsung Electronics Co., Ltd. Model name (Indoor/Outdoor) - AR12HSFSPWKN / AR12HSFSPWKX Sound Power Level (Inside/Outside) dBA 58/62 Refrigerant name1) - R-410a GWP - 2088 SEER 7,5 Energy efficiency class (SEER) - A++ QCE2) (cooling season) kWh/a 163 Pdesignc kW 3,5 SCOP - 4,8 Energy efficiency class (SCOP) - A++ QHE3) (heating season) kWh/a 875 Other heating seasons suitable for use - Pdesignh (Average) kW 3,0 Back up heating capacity(Average) kW 0,0 Declared capacity(Average) kW 3,0 Pdesignh (Warmer) kW - Back up heating capacity (Warmer) kW - Declared capacity (Warmer) kW - Pdesignh (Colder) kW 3,0 Back up heating capacity (Colder) kW 0,0 Declared capacity (Colder) kW 3,0 1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [2088]. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [2088] times higher than 1 kg of CO 2 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. 2) Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located. 3) Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located. Print ErP Information(AC Product)AR12HSFSPWKN / AR12HSFSPWKX According to Commission Regulation (EU) No 206/2012 If function includes heating: Indicate the heating season the information relates to. Indicated values should relate to one heating season at a time. Include at least the heating season 'Average' Function (indicate if persent) cooling Y Average Y heating Y Warmer (if designated) N Colder (if designated) Y Item symbol valu e uni t Design load Item symbol value unit Seasonal efficiency Cooling Pdesign c 3,5 kW cooling SEER 7,5 - heating/Avera ge Pdesign h 3,0 kW heating/Averag e SCOP/ A 4,8 - heating/Warm er Pdesign h - kW heating/Warme r SCOP/ W - - heating/Colder Pdesign h 3,0 kW heating/Colder SCOP/C 4,0 - Declared capacity(*) for cooling, at indoor temperature 27(19) ℃ and outdoor temperature Tj Declared energy efficiency ratio(*), at indoor temperature 27(19) ℃ and outdoor temperature Tj Item symbol valu e unit Item symbol value unit Tj = 35 ℃ Pdc 3,5 kW Tj = 35 ℃ EERd 3,63 - Tj = 30 ℃ Pdc 2,5 kW Tj = 30 ℃ EERd 5,4 - Tj = 25 ℃ Pdc 1,6 kW Tj = 25 ℃ EERd 9,0 - Tj = 20 ℃ Pdc 0,8 kW Tj = 20 ℃ EERd 15 - Declared capacity(*) for heating/Average season, at indoor temperature 20 ℃ and outdoor temperature Tj Declared coefficient of performance(*)/Average season, at indoor temperature 20 ℃ and outdoor temperature Tj Tj = - 7 ℃ Pdh 2,7 kW Tj = -7 ℃ COPd 3,2 - Tj = 2 ℃ Pdh 1,7 kW Tj = 2 ℃ COPd 4,8 - Tj = 7 ℃ Pdh 1,1 kW Tj = 7 ℃ COPd 5,8 - Tj = 12 ℃ Pdh 0,9 kW Tj = 12 ℃ COPd 7,6 - Tj = bivalent temperature Pdh 3,0 kW Tj = bivalent temperature COPd 2,9 - Tj = operating limit Pdh 3,0 kW Tj = operating limit COPd 3,0 - Declared capacity(*) for heating/Warmer season, at indoor temperature 20 ℃ and outdoor temperature Tj Declared coefficient of performance(*)/Warmer season, at indoor temperature 20 ℃ and outdoor temperature Tj Tj = 2 ℃ Pdh - kW Tj = 2 ℃ COPd - - Tj = 7 ℃ Pdh - kW Tj = 7 ℃ COPd - - Tj = 12 ℃ Pdh - kW Tj = 12 ℃ COPd - - Tj = bivalent temperature Pdh - kW Tj = bivalent temperature COPd - - Tj = operating limit Pdh - kW Tj = operating limit COPd - - Declared capacity(*) for heating/Colder season, at indoor temperature 20 ℃ and outdoor temperature Tj Declared coefficient of performance(*)/Colder season, at indoor temperature 20 ℃ and outdoor temperature Tj Tj = -7 ℃ Pdh 1,9 kW Tj = -7 ℃ COPd 3,4 - Tj = 2 ℃ Pdh 1,2 kW Tj = 2 ℃ COPd 4,8 - Tj = 7 ℃ Pdh 0,7 kW Tj = 7 ℃ COPd 5,5 - Tj = 12 ℃ Pdh 0,8 kW Tj = 12 ℃ COPd 7,1 - Tj = bivalent temperature Pdh 3,0 kW Tj = bivalent temperature COPd 2,0 - Tj = operating Pdh 2,7 kW Tj = operating COPd 1,9 - limit Tj = -15 ℃ limit Pdh 2,4 kW Bivalent temperature Tj = -15 ℃ COPd 2,5 - Operating limit temperature heating/Avera ge Tbiv -10 ℃ heating/Averag e Tol -10 ℃ heating/Warm er Tbiv - ℃ heating/Warme r Tol - ℃ heating/Colder Tbiv -22 ℃ heating/Colder Tol -25 ℃ Cycling interval capacity Cycling interval efficiency for cooling Pcycc - kW for cooling EERcyc - - for heating Pcych - kW for heating COPcyc - - kW Degradation co-efficient heating(**) Cdh 0,25 - Degradation co-efficient cooling(**) Cdc 0,25 Electric power input in power modes other than 'active mode' Annual electricity consumption off mode POFF 0,0 kW cooling QCE 163 kWh/a standby mode PSB 0,0 kW heating/Averag e QHE 875 kWh/a thermostat-off mode PTO 0,0 kW heating/Warme r QHE - kWh/a crankcase heater mode PCK 0,0 kW heating/Colder QHE 1575 kWh/a Capacity control (indicate one of three options) Other items fixed N Sound power level (indoor/outdoo r) LWA 58/62 dB(A) staged N Global warming potential GWP 2088 kgCO 2 eq. variable Y Rated air flow (indoor/outdoo r) - 660/192 0 m3/h Contact details for obtaining more information (*)For staged capacity units, two values divided by a slash ('/') will be declared in each box in the section 'Declared capacity of the unit' and 'declared EER/COP' of unit. (**) If default Cd = 0,25 is chosen then (results from) cycling tests are not required. Otherwise either the heating or cooling cycling test value is required.