Technical Data
Rated Current
Rated inductance
Power Operating Frequency
Terminal Type
Weight
Material: Housing
Sealing Compound
16 - 25 A @ Ta 40 °C
0.02 - 0.04 mH, Tol. ±15%
> 5 MHz
Wire leads 17 - 51 g
UL 94V-0 UL 94V-0 Dimension
16A
Isolation Voltage
Climatic Category
Allowable Operation Temp.
2 kV eff., winding to ambient
25/100/21 acc. to IEC 60068-1
-25 °C to 100 °C
25A
+5
10 -2
+5
10 -2
33 ±5
58 ±5
33 ±5
12 max.
60 ±5
80 ±5
EMC Products
60 ±5
17 max.
1
DEH
Suppression Chokes
www.schurter.com/PG81_82
Diagrams
Example of a perfect earth line system using a radiator and an ground line choke
All Variants
In [A]
Ln [mH]
Rcu
[mΩ]
fRES
[MHz]
Weight [g]
Packing unit [pcs.]
Order Number
16
0.02
15
30
17 g
100
DEHL-10-0001
25
0.04
10
20
51 g
50
DEH-15-0001
█
█ Most Popular.
05.06.2016
Availability for all products can be searched real-time:http://www.schurter.com/Stock-Check/StockCheck-SCHURTER
2
EMC Products
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.