typ T13-212

T13-212
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Circuit Breaker for Equipment thermal, Threaded neck type, Reset type, Screw terminals
Description
Applications
-Threaded neck type
-Thermal circuit breaker
-1‑pole
-Reset type
-Wide current range
-High breaking capacity
-Bolts and nuts
-Power supplies
-Uninterruptible power supply
-Power tools
-Household appliances
Weblinks
pdf-datasheet, html-datasheet, General Product Information,
Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product, Product News
Unique Selling Proposition
-Compact design
-Positively trip-free release
-Available with cover
-Different mounting possibilities
Standards
- IEC 60934
- UL 1077
- CSA C22.2 No. 235
- GB 17701
Technical Data
Rated Voltage AC
Rated Voltage DC
Rated current range AC
Conditional short circuit capacity
Short circuit capacity Icn
␣
␣
Degree of Protection
Dielectric Strength
Insulation resistance
Endurance typical
Endurance minimum
240/277 V; 50/60 Hz, see approbations
28 V
0.05 - 30 A
IEC: Inc, PC1, AC 240 V: 1 kA at In < 7 A/240 VAC : 8 x In at In ≥ 7 A/240 VAC : 400 A AC/DC 28 V : 400 A from front side IP 40 acc. to IEC 60529
50 Hz: 1.5 kV
Impulse 1.2/50 μs: > 2.5 kV
500 VDC > 100 MΩ
2 x Ir: 3000 switching cycles
Reset type AC : 2 x Ir , cos φ 0.6 : DC : 2 x Ir , L/R = 2 - 3 ms : 50 switching cycles
Overload
␣
Ambient temperature
Vibration Resistance
Shock Resistance
Tripping Type
Actuation type
Weight
IEC: min. 40 trips
@ 6 x Ir, cos φ 0.6
UL / CSA: min. 50 trips
@ 1.5 x Ir, cos φ 0.75
-5 °C to 60 °C
± 1.5 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Fc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc
100 G / 6 ms
acc. to IEC 60068-2-27, test Ea
Thermal Reset type ca. 10 g
Circuit Breakers
1
T13-212
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Dimension
T13-212
1
2
3/8-27UNS-2A
Ø 13
8.8
6.3
45 - 0.3
8
20
16
Ø5
M4
20.4
+0.4
11.5 - 0.2
31 - 0.0
16
Ø9
.6
8.9
+0.1
- 0.0
Diagrams
T13-...
1
2
2
Circuit Breakers
11.5
T13-212
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Approvals
Approval
Rated current
Rated voltage AC
Rated voltage DC
UL 1077
0.05...30 A
277 V
28 V
CSA C22.2 No. 235
0.05...30 A
277 V
28 V
EN 60934
0.05...30 A
240 V
-
GB 17701
0.05...30 A
240 V
-
Typical internal resistance
Rated Current [A]
Internal Resistance [Ω]
0.05
376.500
0.50
4.40
1.00
1.10
2.00
0.31
3.00
0.14
4.00
0.068
5.00
0.048
6.00
0.033
8.00
0.026
9.00
0.0125
10.00
0.0125
11.00
0.0085
12.00
0.0085
13.00
0.0085
14.00
0.007
15.00
0.007
16.00
0.007
17.00
0.0047
18.00
0.0047
19.00
0.0047
20.00
0.004
21.00
0.0035
22.00
0.003
23.00
0.003
24.00
0.003
25.00
0.003
26.00
0.0022
27.00
0.002
28.00
0.002
29.00
0.002
30.00
0.002
Circuit Breakers
3
T13-212
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Time-Current-Curves
[ min ] [ sec]
10'000
< 7,0 A
> 7,0A
60
30
20
2`000
1`000
10
500
5
200
Time in Seconds
100
1
50
20
10
5
2
1
0,5
0, 3
0, 2
0,1
1,05 1,32
2
3
4
5
8
10
Multiple of Rated Current In
Reference Temperature +23°
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient temperature [°C]
Correction factor
-5
0.88
0
0.90
10
0.95
23
1.00
30
1.05
40
1.10
50
1.18
60
1.26
Example: Rated current = 5 A; Environmental temperature = 40 °C; --> Correction factor =
1.1; Resulting current = 5.5 A --> Fount to next higher rated current: 6 A
Config. Code
T13|-|1|2|3|B|-|1.23|
The characters are placeholders for the correspondingly keys of selections from the key tables.
T13|-| 1 |2|3|B|-|1.23| = Mounting
T13|-|1|2| 3 |B|-|1.23| = Terminal
Mounting
Configuration
key
Threaded neck type with knurled nut
2
T13|-|1| 2 |3|B|-|1.23| = Actuation type
Actuation type
4
1
Circuit Breakers
Screw clamp terminals
Configuration
key
2
T13|-|1|2|3| B |-|1.23| = Setting indication
Configuration
key
Reset type
Terminal
Setting indication
Setting indication
Configuration
key
R
T13-212
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
T13|-|1|2|3|B|-| 1.23 | = Rated current
Rated current
Rated current
Configuration
key
0.05 A
0.05
0.1 A
0.1
0.15 A
0.15
0.2 A
0.2
0.3 A
0.3
0.4 A
0.4
0.5 A
0.5
0.6 A
0.6
0.7 A
0.7
0.8 A
0.8
0.9 A
0.9
1.0
1
1.1 A
1.1
1.2 A
1.2
1.3 A
1.3
1.4 A
1.4
1.5 A
1.5
1.6 A
1.6
1.7 A
1.7
1.8 A
1.8
1.9 A
1.9
2.0 A
2
2.1 A
2.1
2.3 A
2.3
2.5 A
2.5
2.8 A
2.8
3.0 A
3
3.3 A
3.3
Configuration
key
3.5 A
3.5
4.0 A
4
4.5 A
4.5
5.0 A
5
5.5 A
5.5
6.0
6
6.5 A
6.5
7.0 A
7
7.5 A
7.5
8.0 A
8
8.5 A
8.5
9.0 A
9
9.5 A
9.5
10.0 A
10
11.0 A
11
12.0 A
12
13.0 A
13
14.0 A
14
15.0 A
15
16.0 A
16
17.0 A
17
18.0 A
18
19.0 A
19
20.0 A
20
22.0 A
22
25.0 A
25
28.0 A
28
30.0 A
30
Other rated currents on request
Other rated currents on request
Variants
Rated current
Setting indication
Config. Code
Order Number
16.0 A
T13-212-16
4411.0012
30.0 A
T13-212-30
4411.0067
12.0 A
T13-212-12
4411.0099
11.0 A
l
T13-212R-11
4411.0210
15.0 A
l
T13-212R-15
4411.0211
Availability for all products can be searched real-time:http://www.schurter.com/Stock-Check/
Stock-Check-SCHURTER
Packaging Unit 20 Pcs Circuit Breakers
5
T13-212
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Accessories
Description
T-Linie Zubehör
Accessories to T-Line
06.06.2016
6
Circuit Breakers
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.