typ NH-DIN 2 - DIN 2C 500V

NH-DIN 2 - DIN 2C 500V
Heavy current*
www.schurter.com/PG13_14_15
Fuse NH-DIN2-DIN2C 500V
Description
Weblinks
pdf-datasheet, html-datasheet, CE declaration of conformity, RoHS,
REACH, SCHURTER-Stock-Check, CAD-Drawings, Detailed request for
product
-Characteristic gG (gL)
-According to IEC 269
-According VDE 0636
-Selectiviti 1:1.6
-Removal tags energized
Technical Data
Rated Current In
Rated Voltage
Breaking Capacity
Rated Power Operating Frequency fe
40- 400 A
500 VAC
120 kA
50 Hz
Contact blade
Characteristic resistance
Full contact blades, Cu silvered even with alternating load
nonagin to VDE 0636 Combi indicator Indicator
Basic Design
Insulator
Metal components
Ceramic corrosion-resistant (rustproof) Power Dissipation (Watt) operating temperature max.
The power dissipation is the so called power loss at rated current load and operation temeperature acc. VDE 0636 . It is to be measeured in Watt at
AC condition. The voltage tap is to be assured that the power dissipation of the blade contacts are included. This means the measure contact need
to be applied at the ends of the blade contacts. The standard VDE 0636 part 1 and 2 requires that following maximal permissiable power losses are
not exceeded.
Dimensions
e3
a4
10 -0.3
10 -1
d
3 -0.5
6 -0.3
b1
e1
c1
1)
2 min.
a3
2)
a2
6 ±0.2
a1
DIN
e2
a1
a2
a3
a4
b1
c1
d
e1
e2
e3
2
150 ±2,5
75 -10
62 ±2,5
68 ±2,5
25 +0,2
48 ±0,8
2,5 +1,5/-0,5
59
50 ±0,70
20 +5/-2
2C
150 ±2,5
75 -10
62 ±2,5
68 ±2,5
20 +0,2
48 ±0,8
2,5 +1,5/-0,5
49
40 ±0,65
20 +5/-2
1) Centre indicator
2) Flat indicator
other products
1
NH-DIN 2 - DIN 2C 500V
Heavy current*
www.schurter.com/PG13_14_15
Time-Current-Curves
DIN00 - DIN3, 400-500 V
10'000
Time in Seconds
A
0
160
A
A
A
800
0A
125
0
100
10
630
A
355
A
500
A
125
A
200
A
250
A
100
A
160
A
224
A
5
31
A
0
40
80 A
63 A
40 A
25 A
35 A
50 A
20 A
32 A
16 A
100
10 A
6A
4A
2A
1000
1
0.1
0.01
0.001
1
10
Current in Amperes
2
other products
100
1000
10'000
100'000
NH-DIN 2 - DIN 2C 500V
Heavy current*
www.schurter.com/PG13_14_15
Current limiting diagram
0A
160
0A
125 1000 A
A
630
00 A
100
8
10
16 A
A
400
A
315 A
224
A
160
A
100
63 A
40 A
32 A
20 A
10 A
ID in Ka
A
500
A
355
A
250
A
200
A
125
80 A
50 A
35 A
25 A
6A
1
χ=
2
χ=
1
.6
χ=
1
0.1
0.1
1
IP in Ka
10
100
The prospective short circuit current is the value of the current, that would flow if there was no protection in the circuit.
ID
Let-through courrent
IG
Value of DC component
IP
Prospective short-circuit current
IS
Short-circuit peak current
X
Factor (X=2 für cosφ=0; X=1 für cosφ=1)
other products
3
NH-DIN 2 - DIN 2C 500V
Heavy current*
www.schurter.com/PG13_14_15
All Variants
Rated current
Style
Power Loss
Order Number
E-No
[A]
[Compact]
[W]
40
C
50
C
3.8
1301.0321
840502149
4.6
1301.0322
63
840502159
C
5.8
1301.0323
840502179
80
C
6.4
1301.0324
840502199
100
C
8.3
1301.0325
840502209
125
C
10.0
1301.0326
840502219
160
C
12.8
1301.0327
840502239
200
C
15.8
1301.0328
840502249
█
250
C
19.1
1301.0330
840502269
█
315
-
21.6
1301.0311
840102289
█
400
-
26.8
1301.0313
840102309
█
█ Most Popular.
Availability for all products can be searched real-time:http://www.schurter.com/Stock-Check/Stock-Check-SCHURTER
3 Pcs 20.06.2016
Packaging unit 4
other products
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.