FAB Fuseholders www.schurter.com/PG02 Shock-Safe Fuseholder, 5 x 20 mm, Slotted Cap, horizontal 250 VAC · 2.5 W / 10 A (VDE)12 A (UL) Description Weblinks -Kinked or straight PCB-terminals -Horizontal style -Compact size pdf-datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH, SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for product Standards -IEC 60127-6␣Edition 2.0 -UL 4248-1 -CSA 22.2 no. 4248.1 Approvals -VDE Certificate Number: 133921 -UL File Number: E39328 Technical Data Shock-Safe Category Fuse-Link Mounting Terminal Rated Voltage Rated current Rated Power Acceptance IEC Soldering Methods PC2 5 x 20 mm PCB Solder THT 250 VAC 10 A (VDE), 12 A (UL) 2.5 W / 10 A @ Ta 23 °C Admissible power acceptance at higher ambient temperature see derating curves Degree of Protection IP 40 Protection Class Suitable for appliances with protection class I or II acc. to IEC 61140 Admissible Ambient Air Temp. -40 °C to 85 °C Climatic Category 40/085/21 acc. to IEC 60068-1 Material: Socket Thermoplastic, UL 94V-0 Material: Cap Thermoplastic, UL 94V-0 Material: Terminals Tin-Plated Copper Alloy Unit Weight 5.4 g Storage Conditions 0 °C to 60 °C, max. 70% r.h. Product Marking , Type, Rated Voltage, Rated current, Power Rating, Approvals Dimension Solderability Resistance to Soldering Heat Contact Resistance Dielectric Strength Impulse Withstand Voltage Insulation Resistance Overvoltage Category Pollution Degree Resistance to Vibration Wave Soldering Profile 245 °C / 3 sec acc. to IEC 60068-2-20, Test Ta, method 1 260 °C / 10 sec acc. to IEC 60068-2-20, Test Tb, method 1 ≤ 10 mΩ at 20 mV acc. to IEC 60127-6 > 3 kV between Life parts (50 Hz; 1 min) > 4 kV between Life parts ≥ 10 MΩ between Life parts (500 VDC; 1 min) III acc. to IEC 60664-1 3 acc. to IEC 60664-1 acc. to IEC 60068-2-6, test Fc 31.5 mm 12 ±0.2 31.5 6 +0.1 0 5 16.25 10 ±0.3 Variant 0031.3551 and 0031.3558 5 5 1.8 10.06 +0.1 0 1.3 10 ±0.1 1.1 Drilling diagram Fuses 1 FAB Fuseholders www.schurter.com/PG02 Derating Curves 5x20 mm Admissible Power Acceptance in Watt 2.5 2.0 I = 1.0 In 1.5 I = 0.7 In I = < < In 1.0 0.5 0.0 0 20 40 60 80 100 Ambient Air Temperature Ta °C All Variants Holder Cap Terminal Degree of Protection Order Number l slotted straight IP 40 0031.3551 █ l slotted kinked IP 40 0031.3558 █ █ Most Popular. Availability for all products can be searched real-time:http://www.schurter.com/StockCheck/Stock-Check-SCHURTER Bulk (100 pcs.) 05.06.2016 Packaging Unit 2 Fuses The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.