typ FAB

FAB
Fuseholders
www.schurter.com/PG02
Shock-Safe Fuseholder, 5 x 20 mm, Slotted Cap, horizontal
250 VAC · 2.5 W / 10 A (VDE)12 A (UL)
Description
Weblinks
-Kinked or straight PCB-terminals
-Horizontal style
-Compact size
pdf-datasheet, html-datasheet, General Product Information,
Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product
Standards
-IEC 60127-6␣Edition 2.0
-UL 4248-1
-CSA 22.2 no. 4248.1
Approvals
-VDE Certificate Number: 133921
-UL File Number: E39328
Technical Data
Shock-Safe Category
Fuse-Link
Mounting
Terminal
Rated Voltage
Rated current
Rated Power Acceptance IEC
Soldering Methods
PC2
5 x 20 mm
PCB
Solder THT
250 VAC 10 A (VDE), 12 A (UL)
2.5 W / 10 A @ Ta 23 °C
Admissible power acceptance at higher
ambient temperature see derating curves
Degree of Protection
IP 40
Protection Class
Suitable for appliances with protection
class I or II acc. to IEC 61140
Admissible Ambient Air Temp. -40 °C to 85 °C
Climatic Category
40/085/21 acc. to IEC 60068-1
Material: Socket
Thermoplastic, UL 94V-0
Material: Cap
Thermoplastic, UL 94V-0
Material: Terminals
Tin-Plated Copper Alloy
Unit Weight
5.4 g
Storage Conditions
0 °C to 60 °C, max. 70% r.h.
Product Marking
, Type, Rated Voltage, Rated current,
Power Rating, Approvals
Dimension
Solderability
Resistance to Soldering Heat
Contact Resistance
Dielectric Strength
Impulse Withstand Voltage
Insulation Resistance
Overvoltage Category
Pollution Degree
Resistance to Vibration
Wave
Soldering Profile
245 °C / 3 sec acc. to IEC 60068-2-20,
Test Ta, method 1
260 °C / 10 sec acc. to IEC 60068-2-20,
Test Tb, method 1
≤ 10 mΩ at 20 mV acc. to IEC 60127-6
> 3 kV between Life parts
(50 Hz; 1 min)
> 4 kV between Life parts
≥ 10 MΩ between Life parts
(500 VDC; 1 min)
III acc. to IEC 60664-1
3 acc. to IEC 60664-1
acc. to IEC 60068-2-6, test Fc
31.5 mm
12 ±0.2
31.5
6
+0.1
0
5
16.25 10 ±0.3
Variant 0031.3551 and 0031.3558
5 5
1.8
10.06
+0.1
0
1.3
10 ±0.1
1.1
Drilling diagram
Fuses
1
FAB
Fuseholders
www.schurter.com/PG02
Derating Curves
5x20 mm
Admissible Power Acceptance in Watt
2.5
2.0
I = 1.0 In
1.5
I = 0.7 In
I = < < In
1.0
0.5
0.0
0
20
40
60
80
100
Ambient Air Temperature Ta °C
All Variants
Holder
Cap
Terminal
Degree of Protection
Order Number
l
slotted
straight
IP 40
0031.3551
█
l
slotted
kinked
IP 40
0031.3558
█
█ Most Popular.
Availability for all products can be searched real-time:http://www.schurter.com/StockCheck/Stock-Check-SCHURTER
Bulk (100 pcs.)
05.06.2016
Packaging Unit 2
Fuses
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.