PLN-100 100W Single Output Switching Power Supply series Features : Universal AC input / Full range (up to 295VAC) High efficiency up to 88.5% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection Built-in active PFC function IP64 design for indoor or outdoor installations Pass LPS Class 2 power unit 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications Suitable for dry / damp locations Compliance to worldwide safety regulations for lighting 2 years warranty 110 F M M SELV LPS ( for 48V only) ( except for 48V ) IP64 SPECIFICATION MODEL DC VOLTAGE PLN-100-12 PLN-100-15 PLN-100-20 PLN-100-24 PLN-100-27 PLN-100-36 PLN-100-48 12V 15V 20V 24V 27V 36V 48V CONSTANT CURRENT REGION Note.6 9 ~ 12V OUTPUT RATED CURRENT Note.5 5A RATED POWER Note.5 60W 18 ~ 24V 20.25 ~ 27V 27 ~ 36V 36 ~ 48V 4A 3.55A 2.65A 2A 75W 96W 96W 95.85W 95.4W 96W 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p VOLTAGE ADJ. RANGE (SVR1) 10.2 ~ 12V 12.8 ~ 15V 17 ~ 20V 20.4 ~ 24V 23 ~ 27V 30.6 ~ 36V 40.8 ~ 48V CURRENT ADJ. RANGE(SVR2) 3.75 ~ 5A 3.75 ~ 5A 3.6 ~ 4.8A 3 ~ 4A 2.6 ~ 3.55A 2 ~ 2.65A 1.5 ~ 2A 3.0% 3.0% 2.0% 2.0% VOLTAGE TOLERANCE Note.3 3.0% LINE REGULATION 1.0% 3.0% 2.0% 60ms/230VAC 30ms/115VAC at full load HOLD UP TIME (Typ.) VOLTAGE RANGE 3.0% 1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load SETUP, RISE TIME Note.4 90 ~ 295VAC 127 ~ 417VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER CURRENT SHORT CIRCUIT PROTECTION 15 ~ 20V 4.8A RIPPLE & NOISE (max.) Note.2 150mVp-p LOAD REGULATION INPUT 11.25 ~ 15V 5A OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS Note.7 83% 85% 12V:0.8A/115VAC 88.5% 88.5% 0.4A/230VAC 0.3A/277VAC 20V ~ 48V:1.1A/115VAC 0.55A/230VAC COLD START 40A/230VAC 88% 15V:0.9A/115VAC 88% 0.45A/277VAC <0.75mA / 240VAC 95 ~ 102% Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed 13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 30 ~ 36V 39 ~ 48V 90 10 (RTH2) Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +50 (Refer to "Derating Curve") 20 ~ 95% RH non-condensing -40 ~ +80 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes UL879, UL1310, UL8750, CSA C22.2 No. 207-M89(except for 48V), TUV EN61347-1, EN61347-2-13 independent, TUV EN60950-1, CAN/CSA C22.2 No. 223-M91(except for 48V), CSA C22.2 No. 250.0-08(except for 48V), IP64, J61347-1, J61347-2-13 approved ; design refer to UL60950-1 I/P-O/P:3.75KVAC EMC ISOLATION RESISTANCE EMC EMISSION I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (>75% load) ; EN61000-3-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A MTBF 303.1Khrs min. MIL-HDBK-217F (25 200*70.5*35mm (L*W*H) 0.52Kg; 20pcs/12.5Kg/0.76CUFT DIMENSION PACKING NOTE 52 ~ 64V Protection type : Shut down and latch off o/p voltage, re-power on to recover SAFETY & WITHSTAND VOLTAGE OTHERS 88.5% 0.45A/230VAC 0.35A/277VAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 6. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. File Name:PLN-100-SPEC 2012-03-12 PLN-100 100W Single Output Switching Power Supply Mechanical Specification Case No.955A series Unit:mm 200 2-R2.5 310 20 310 20 T case +V(Red) -V(Black) 100 35.25 70.5 AC/L(Brown) AC/N(Blue) FG (Green/Yellow) SVT 18AWG 3C SVT 18AWG 2C 22.84 22.84 6.26 6.26 35 T case: Max. Case Temperature. Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2 shown in the diagram. SVR1 SVR2 SVR1 Output voltage adjustment SVR2 Output current adjustment Fosc : 100KHz Block Diagram EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V O.L.P. FG O.L.P. PFC CONTROL DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. Derating Curve Static Characteristics 100 100 90 80 230VAC Input only 80 70 LOAD (%) LOAD (%) 60 40 20 -30 -25 -10 0 15 30 40 AMBIENT TEMPERATURE ( ) 50 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 295 INPUT VOLTAGE (V) 60Hz File Name:PLN-100-SPEC 2012-03-12 PLN-100 100W Single Output Switching Power Supply series Power Factor Characteristic PF Constant Current Mode 1 .0 0 0 .9 8 0 .9 6 0 .9 4 0 .9 2 0 .9 0 0 .8 8 0 .8 6 0 .8 4 0 .8 2 0 .8 0 0 .7 8 277V ac 230V ac 115V ac 50% 60% 70% 80% 90% 100% (100W) LOAD EFFICIENCY vs LOAD (48V Model) PLN-100 series possess superior working efficiency that up to 89% can be reached in field applications. 92 88 EFFICIENCY (%) 84 80 277Vac 76 230Vac 72 115Vac 68 64 60 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE There are two major kinds of LED drive method "direct drive" and "with LED driver". A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs. Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)]. Vo(%) 100 (B) Constant Current area (A) Constant Voltage area 75 (max.) (C) Hiccup Protection 50 100 Io (%) Typical LED power supply I-V curve File Name:PLN-100-SPEC 2012-03-12