LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification SPECIFICATION FOR APPROVAL ( ♦ ) Preliminary Specification ( ) Final Specification Title 10.4” SVGA TFT LCD SUPPLIER BUYER MODEL LG.Philips LCD Co., Ltd. Model LP104S5 SUFFIX A2VT * When you obtain standard approval , please use the above model name without suffix. SIGNATURE DATE APPROVED BY / S. H. Kang / G.Manager / REVIEWED BY J. H. Lee / Manager H.S. Yoon / Manager / PREPARED BY S.Y. Lee / Engineer J.H. Hwang / Engineer Please return 1 copy for your confirmation DATE Product Engineering Dept. with your signature and comments. LG.Philips LCD Co., Ltd. Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 1 / 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification CONTENTS NO. ITEM Page - COVER 1 - CONTENTS 2 - RECORD OF REVISIONS 3 1 GENERAL DESCRIPTION 4 2 ABSOLUTE MAXIMUM RATINGS 5 3 ELECTRICAL SPECIFICATIONS 3-1 ELECTRICAL CHARACTERISTICS 6 3-2 INTERFACE CONNECTIONS 7 3-3 SIGNAL TIMING SPECIFICATIONS 9 3-4 SIGNAL TIMING WAVEFORMS 10 3-5 COLOR INPUT DATA REFERENCE 11 3-6 POWER SEQUENCE 12 4 OPTICAL SPECIFICATIONS 13 5 MECHANICAL CHARACTERISTICS 16 6 RELIABILITY 20 7 INTERNATIONAL STANDARDS 7-1 SAFETY 21 7-2 EMC 21 8 PACKING 8-1 DESIGNATION OF LOT MARK 22 8-2 PACKING FORM 22 9 PRECAUTIONS 23 Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 2 / 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification RECORDS OF REVISIONS Version No Date Page 0.0 Oct 06, 2000 - DESCRIPTION First draft Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 3 / 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 1. General Description The LP104S5-A2VT is a Color Active Matrix Liquid Crystal Display with an integral Cold Cathode Fluorescent Lamp(CCFL) backlight system. The matrix employs a-Si Thin Film Transistor as the active element. It is a transmissive type display operating in the normally white mode. This TFT-LCD has a 10.4 inches diagonally measured active display area with SVGA resolution(600 vertical by 800 horizontal pixel array). Each pixel is divided into Red, Green and Blue sub-pixels or dots which are arranged in vertical stripes. Gray scale or the brightness of the sub-pixel color is determined with a 6-bit gray scale signal for each dot, thus, presenting a palette of more than 262,144 colors. The LP104S5-A2VT is intended to support applications where thin thickness is critical factors and graphic displays are important. In combination with the vertical arrangement of the sub-pixels, the LP104S5-A2VT characteristics provide an excellent flat panel display for office automation products such Timing Control Block Column driver circuit Row Driver circuit TTL interface CN1 as Notebook PC. Power Block CN2 TFT-LCD (800 X 600) Backlight Ass’y CN1: FI-XB30S-HF10 or equivalent , CN2: BHSR-02VS-1(JST) General Features Active screen size 10.4 inches(264.16mm) diagonal Outline dimensions 224.5(H) X 172.0(V) X 5.7(D) mm (Typ.) Pixel pitch 0.264 mm X 0.264 mm Pixel format 800 horiz. by 600 vert. pixels RGB stripe arrangement Color depth 6-bit, 262,144 colors Luminance,White 170 cd/m (Typ.) Power Consumption Total 3.9 Watt(Typ.) Weight 310g (Typ.) Display operating mode Surface treatments 2 Transmissive mode, normally white Hard coating (3H), Anti-glare treatmentAlpha of the front Point Ltd.polarizer Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 4 / 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 2. Absolute Maximum Ratings The following are maximum values which, if exceeded, may cause faulty operation or damage to the unit. Table 1 Parameter Power Input Voltage Operating Temperature Operating Tempe. for Panel Storage Temperature Operating Ambient Humidity Storage Humidity ABSOLUTE MAXIMUM RATINGS Values symbol Min. Max. 4.0 VCC -0.3 50 0 TOP 60 0 60 -20 TST 90 10 HOP 90 10 HST Units Notes Vdc at 25 ± 5°C 1 2 1 1 1 °C °C °C %RH %RH Note: 1. Temperature and relative humidity range are shown in the figure below. Wet bulb temperature should be 39°C Max, and no condensation of water. 2. The surface temperature caused by self heat radiation of cell itself is specified on this item. Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 5 / 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 3. Electrical Specifications 3-1. Electrical Characteristics The LP104S5-A2VT requires two power inputs. One is employed to power the LCD electronics and to drive the TFT array and liquid crystal. The second input which powers the CCFL, is typically generated by an inverter. The inverter is an external unit to the LCD. Table 2 ELECTRICAL CHARACTERISTICS: Parameter Symbol Values Min. Typ. Max. Module 3.6 3.3 3.0 VCC Power Supply Input Voltage 360 290 ICC Power Supply Input Current 1.2 0.96 Pc Power Consumption 1.5 1.0 IRUSH Rush Current Lamp 475(7mA) 500(6mA) 640(3mA) VBL Operating Voltage IBL Operating Current 3.0 6.0 7 845 Established Starting Voltage at 25°C 1015 0°C 3 Ts Discharge Stabilization Time 80 fBL 45 60 Operating Frequency 3.3 PBL 3.0 Power Consumption 20,000 Life Time Units Notes Vdc A W A 1 1 3 4 VRMS mA 5 VRMS 5 VRMS 7 min 6 kHz 8 Watts 9 Hours Notes: The design of the inverter must have specifications for the lamp in LCD Assembly. The performance of the Lamp in LCM,for example life time or brightness,is extremely influenced by the characteristics of the DC-AC Inverter.So all the parameters of an inverter should be carefully designed so as not to produce too much leakage current from high-voltage output of the inverter. When you design or order the inverter,please make sure unwanted lighting caused by the mismatch of the lamp and the inverter(no lighting,flicker,etc) never occurs.When you confirm it,the LCD Assembly should be operated in the same condition as installed in your instrument. 1. The specified current and power consumption are under the Vcc = 3.3V , 25°C, fv = 60Hz condition whereas mosaic pattern is displayed. 2. The duration of rush current is about 20ms. 3. The variance of the voltage is ±10%. 4. The voltage above Vs should be applied to the lamps for more than 1second for start-up. Otherwise,the lamps may not be turned on. 5. The output of the inverter must have symmetrical(negative and positive) voltage waveform and symmetrical current waveform.(Unsymmetrical ratio is less than 10%) Please do not use the inverter which has unsymmetrical voltage and unsymmetrical current and spike wave. Lamp frequency may produce interference with horizontal synchronous frequency and as a result this may cause beat on the display. Therefore lamp frequency shall be as away as possible from the horizontal synchronous frequency and from its harmonics in order to prevent interference. 6. Let’s define the brightness of the lamp after being lighted for 5 minutes as 100%. Ts is the time required for the brightness of the center of the lamp to be not less than 95%. Ver 0.0 Oct.06. 2000 Page 6 / 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 7. The lamp power consumption shown above does not include loss of external inverter. 8. The life time is determined as the time at which brightness of lamp is 50% compared to that of initial value at the typical lamp current on condition of continuous operating at 25 ±2°C. Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 7 / 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 3-2. Interface Connections This LCD employs interface connection, a 30 pin connector is used for the module electronics and a two pin connector is used for the backlight system. The electronic interface connector is a FI-XB30S-HF10, manufactred by JAE. The pin configuration for the connector is shown in the table below. Table 3 MODULE CONNECTOR PIN CONFIGURATION (LVDS) Pin Symbol Description Notes 1 Vcc Power (3.3V) 1. Connector 2 Vcc Power (3.3V) 1.1 LCD: FI-XB30S-HF10 or equivalent 3 GND Ground 1.2 Mating:FI-30M (FPC Type) 4 DTMG Data Enable FI-X30H (Cable Type) 5 VSYNC Vertical sync 1.3 Connector pin arrangement 6 HSYNC Horizontal sync 7 GND Ground 8 DCLK Data Clock 30 1 9 GND Ground 10 R5 Red data (MSB) 11 R4 Red data 12 R3 Red data 13 R2 Red data [ LCD Module Rear View ] 14 R1 Red data 15 R0 Red data (LSB) 16 GND Ground 17 G5 Green data(MSB) 18 G4 Green data 19 G3 Green data 20 G2 Green data 21 G1 Green data 22 G0 Green data(LSB) 23 GND Ground 24 B5 Blue data (MSB) 25 B4 Blue data 26 B3 Blue data 27 B2 Blue data 28 B1 Blue data 29 B0 Blue data (LSB) 30 GND Ground The backlight interface connector is a model BHSR-02VS-1, manufactured by JST. connector part number is SM02B-BHSS-1 or equivalent. The mating The pin configuration for the connector is shown in the table below. Table 4 Pin 1 2 Notes: BACKLIGHT CONNECTOR PIN CONFIGURATION Symbol Description Power supply for lamp HV (High voltage side) Power supply for lamp LV (Low voltage side) Notes 1 1 1. The high voltage side terminal is colored pink. The low voltage side terminal is black Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 8 / 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 3 - 3 . Signal Sign al Timing Specifications All of the interface signal timing should be satisfied with the following specifications for it’s proper operation. Table 6 Timing Table ITEM SYMBOL MIN. TYP. MAX. UNIT NOTE TYP. 38.5MHz Dclk Period tCLK 25 26 27 ns Hsync Period tHP 990 1024 1100 tCLK Width-Active tWH 12 - 120 Period tVP 604 625 730 tHP Frequency fV - 60 - Hz Width-Active tWV 1 - 24 tHP DE H-Back Porch tHBP 30 - - tCLK (Data H-Front Porch tHFP 30 - - Enable) V-Back Porch tVBP 0 - - V-Front Porch tVFP 3 - - Vsync Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland tHP Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 9 / 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 3-4. Signal Timing Waveforms Hsync, Vsync, DE, DATA 0.7Vcc 0.3Vcc 0.5V CC DCL VALID INVALID INVALID DAT DE(Data Enable) t HP H s ync t WH t HF t HBP D E(Data t VP t WV Vsync t VBP t VFP DE(Data Enable) Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 10/ 10/ 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 3-5. Color Input Data Reference The brightness of each primary color(red, green and blue) is based on the 6-bit gray scale data input for the color; the higher the binary input, the brighter the color. The table below provides a reference for color versus data input. Color MSB Table 7 COLOR DATA REFERENCE Input Color Data Red Green LSB MSB LSB MSB Blue LSB R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Black 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Red(63) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0 Green(63) Basic Blue(63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 Colors Cyan 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 1 Magenta 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 Yellow 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 White Red(00) Dark 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Red(01) 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 Red(02) 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 Red : : : : : : : : : : : : : : : : : : Red(61) 1 1 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 Red(62) 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 Red(63) Bright 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Green(00)Dark 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 Green(01) 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 Green(02) Green : : : : : : : : : : : : : : : : : : 0 0 0 0 0 0 1 1 1 1 0 1 0 0 0 0 0 0 Green(61) 0 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 0 Green(62) Green(63)Bright 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0 Blue(00) Dark 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Blue(01) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 Blue(02) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 Blue : : : : : : : : : : : : : : : : : : Blue(61) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 1 Blue(62) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0 Blue(63) Bright 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 11/ 11/ 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 3-6. Power Sequence 90% Power Supply For LCD VCC 90% 10% 10% 0V T2 T5 T1 Interface Signal, Vi (LVDS Signal of Transmitter) Data Power for Lamp 0 200 200 0 400 T1 T2 T3 T4 T5 T6 T7 T3 Values Typ. - T4 LAMP ON OFF Min. T7 Valid 0V Parameter T6 OFF Units Max. 10 50 50 10 - ms Notes: 1. Please avoid floating state of interface signal at invalid period. 2. When the interface signal is invalid, be sure to pull down the power supply for LCD VCC to 0V. 3. Lamp power must be turn on after power supply for LCD and interface signal are valid. Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 12/ 12/ 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 4. Optical Specifications Optical characteristics are determined after the unit has been ‘ON’ and stable for approximately 30 minutes in a dark environment at 25°C. The values specified are at an approximate distance 50cm from the LCD surface at a viewing angle of Φ and θ equal to 0°C. FIG 1. presents additional information concerning the measurement equipment and method. FIG. 1 Optical Characteristic Measurement Equipment and Method Optical Stage(x,y) LCD Module Field = 1° Prichard 880 or equivalent 500mm Table 8 mA) ( Ta=25°C, Vcc=3.3V, f V =60Hz, Dclk=38.5MHz, IBL= 6 OPTICAL CHARACTERISTICS Parameter Symbol Contrast Ratio Surface Luminance, white Luminance Variation Response Time Rise Time Decay Time CIE Color Coordinates Red Green Blue White Viewing Angle x axis, right (Φ=0º) x axis, left(Φ=180º) y axis, up(Φ=90º) y axis, down (Φ=270º) Gray Scale Min. Values Typ. Max. 150 - 200 170 1.35 - xR yR xG yG xB yB xW yW θr θl θu θd CR L WH δ WHITE Tr TrR TrD Units Notes 1.45 cd/m2 1 2 3 30 30 50 50 ms 4 0.283 0.299 TBD TBD TBD TBD TBD TBD 0.313 0.329 0.343 0.359 40 40 10 30 - - degree 5 - - - 6 Notes: 1. Contrast Ratio (CR) is defined mathematically as : Surface Luminance with all white pixels Contrast Ratio = Surface Luminance with all black pixels 2. Surface luminance is the center point across the LCD surface 50cm from the surface with all Ver 0.0 Oct.06. 2000 Page 13/ 13/ 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification pixels displaying white. For more information see FIG 1. 3. The variation in surface luminance, δ WHITE is determined by measuring LON at each test position 1 through 5, and then dividing the maximum L ON of 5 points luminance by minimum L ON of 5 points luminance. For more information see FIG 2. δ WHITE Maximum (LON1, L ON2, ....L ON5) ÷ Minimum (LON1, LON2, ....LON5) 4. Response time is the time required for the display to transition from white to black (Rise Time, TrR) and from black to white (Decay Time, TrD). For additional information see FIG 3. 5. Viewing angle is the angle at which the contrast ratio is greater than 10. The angles are determined for the horizontal or x axis and the vertical or y axis with respect to the z axis which is normal to the LCD surface. For more information see FIG 4. 6.Gray scale specification. * Gamma Value = 2.2 Gray Level Luminance(%) (Typ.) L0 TBD L7 TBD L15 TBD L23 TBD L31 TBD L39 TBD L47 TBD L55 TBD L63 100 FIG. 2 Luminance <measuring point for luminance variation> 200 400 600 400 2 1 1 50 300 300 3 4 <measuring point for surface luminance > 5 450 Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 14/ 14/ 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification FIG. 3 Response Time The response time is defined as the following figure and shall be measured by switching the input signal for ‘black’ and ‘white’. TrD TrR % 100 90 Opt i c a l Res p o n s e 10 0 whi t e whi t e bl ack FIG. 4 Viewing angle <Definition of viewing angle range> φ = 90 (12:00) θ= 0 yu z A θ φ xl φ =180 φ= 0 (9:00) (3:00) TFT LCD MODULE z' yd xr φ =270 (6:00) A: Eye o Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 15/ 15/ 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 5. Mechanical Characteristics The contents provide general mechanical characteristics for the model LP104S5-B2AP LCD. In addition, the figures in the next page are detailed mechanical drawings of the LCD. Outside dimensions : Horizontal 224.5 ± 0.5 mm Vertical 172.0 ± 0.5 mm Depth 5.7 ± 0.3 mm Horizontal 214.2 ± 0.5 mm Vertical 161.8 ± 0.5 mm Bezel area : Active Display area : Horizontal 211.2 mm Vertical 158.4 mm Weight (approximate) : 310g (Typ.), 320g(Max.) Surface Treatment : Hard coating (3H) Anti-glare treatment of the front polarizer Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 16/ 16/ 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification < FRONT VIEW > Ver 0.0 Oct.06. 2000 Page 17/ 17/ 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification < REAR VIEW > <DETAIL DESCRIPTION OF SIDE MOUNTING SCREW> Ver 0.0 Oct.06. 2000 Page 18/ 18/ 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification ` TOP CASE (SUS Panel Supporter Main 4 -M2 Bottom Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Cover (SUS Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 19/ 19/ 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 6. Reliability - Environment test condition No. Test Item Conditions 1 High temperature storage test Ta = 60°C 240h 2 Low temperature storage test Ta = -20°C 240h 3 High temperature operation test Ta = 50°C 50%RH 240h 4 Low temperature operation test Ta = 0°C 240h 5 Vibration test (non-operating) 6 Sine wave, 10~500~10Hz, 1.5G, 0.37oct/min, 3 axis, 1 hour/axis Shock test Half sine wave, 180G, 2ms, (non-operating) one shock of each six faces (i.e. run 180G 2ms for all six faces.) 7 Altitude operating 0 - 10,000 feet (3048m) storage/shipment 0 - 40,000 feet (12192m) {Result Evaluation Criteria} There should be no change which might affect the practical display function when the display quality test is conducted under normal operating condition. Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 20/ 20/ 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 7. International Standards 7-1. Safety a) UL 1950 Third Edition, Underwriters Laboratories, Inc. Jan. 28, 1995. Standard for Safety of Information Technology Equipment Including Electrical Business Equipment. b) CAN/CSA C22.2 No. 950-95 Third Edition, Canadian Standards Association, Jan. 28, 1995. Standard for Safety of Information Technology Equipment Including Electrical Business Equipment. c) EN 60950 : 1992 + A1 : 1993 + A2 : 1993 + A3 : 1995 + A4 : 1997 + A11 : 1997 IEC 950 : 1991 + A1 : 1992 + A2 : 1993 + A3 : 1995 + A4 : 1996 European Committee for Electrotechnical Standardization (CENELEC) EUROPEAN STANDARD for Safety of Information Technology Equipment Including Electrical Business Equipment. 7-2. EMC a) ANSI C63.4 ‘Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9kHz to 40GHz.’ American National Standards Institute(ANSI),1992. b) C.I.S.P.R ‘Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment.’ International Special Committee on Radio Interference c) EN 55022 ‘Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment.’ European Committee for Electrotechnical Standardization (CENELEC),1988 Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 21/ 21/ 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 8. Packing 8-1. Designation of Lot Mark a) Lot Mark A B C D E F G H I J K L M A, B ,C : INCH CODE D : YEAR E : MONTH F,G : PANEL CODE H : ASSEMBLY CODE I,J,K,L,M : SERIAL NO. Note : 1. YEAR YEAR 97 98 99 2000 2001 2002 2003 2004 2005 2006 2007 Mark 7 8 9 0 1 2 3 4 5 6 7 2. MONTH MONTH Jan. Feb. Mar. Apr. May. Jun. Jul. Aug. Sep. Oct. Nov. Dec. Mark 1 2 3 4 5 6 7 8 9 A B C b) Location of Lot Mark Serial NO. Is printed on the label. The label is attached to the backside of the LCD module. This is subject to change without prior notice. 8-2. Packing Form a) Package quantity in one box : 10 pcs b) Box Size : 371mm X 239mm X 300mm Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 22/ 22/ 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 9.PRECAUTIONS Please pay attention to the followings when you use this TFT LCD module. 9.1 MOUNTING PRECAUTIONS (1) You must mount a module using holes arranged in four corners or four sides. (2) You should consider the mounting structure so that uneven force (ex. twisted stress) is not applied to the module. And the case on which a module is mounted should have sufficient strength so that external force is not transmitted directly to the module. (3) Please attach a transparent protective plate to the surface in order to protect the polarizer. Transparent protective plate should have sufficient strength in order to resist external force. (4) You should adopt radiation structure to satisfy the temperature specification. (5) Acetic acid type and chlorine type materials for the cover case are not desirable because the former generates corrosive gas of attacking the polalizer at high temperature and the latter causes circuit break by electro-chemical reaction. (6) Do not touch, push or rub the exposed polarizers with glass, tweezers or anything harder than HB pencil lead. And please do not rub with dust clothes with chemical treatment. Do not touch the surface of polarizer for bare hand or greasy cloth. (Some cosmetics are detrimental to the polarizer.) (7) When the surface becomes dusty, please wipe gently with absorbent cotton or other soft materials like chamois soaked with petroleum benzene. Normal-hexane is recommended for cleaning the adhesives used to attach front / rear polarizers. Do not use acetone, toluene and alcohol because they cause chemical damage to the polarizer. (8) Wipe off saliva or water drops as soon as possible. Their long time contact with polarizer causes deformations and color fading. (9) Do not open the case because inside circuits do not have sufficient strength. 9.2 OPERATING PRECAUTIONS (1) The spike noise causes the mis-operation of circuits. It should be lower than following voltage : V = ± 200mV (Over and under shoot voltage). (2) Response time depends on the temperature. (In lower temperature, it becomes longer.) (3) Brightness depends on the temperature. (In lower temperature, it becomes lower.) And in lower temperature, response time (required time that brightness is stable after turned on ) becomes longer. (4) Be careful for condensation at sudden temperature change. Condensation makes damage to polarizer or electrical contacted parts. And after fading condensation, smear or spot will occur. (5) When fixed patterns are displayed for a long time, remnant image is likely to occur. (6) Module has high frequency circuits. Sufficient suppression to the electromagnetic interference shall be done by system manufacturers. Grounding and shielding methods may be important to minimize the interference. Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 23/ 23/ 23 LP104S5LP104S5- A2VT Liquid Crystal Display Product Specification 9.3 ELECTROSTATIC DISCHARGE CONTROL Since a module is composed of electronic circuits, it is not strong to electrostatic discharge. Make certain that treatment persons are connected to ground through wrist band etc . And don’t touch interface pin directly. 9.4 PRECAUTIONS FOR STRONG LIGHT EXPOSURE Strong light exposure causes degradation of polarizer and color filter. 9.5 STORAGE When storing modules as spares for a long time, the following precautions are necessary. (1) Store them in a dark place. Do not expose the module to sunlight or fluorescent light. Keep the temperature between 5°C and 35°C at normal humidity. (2) The polarizer surface should not come in contact with any other object. It is recommended that they be stored in the container in which they were shipped. 9.6 HANDLING PRECAUTIONS FOR PROTECTION FILM (1) When the protection film is peeled off, static electricity is generated between the film and polarizer. This should be peeled off slowly and carefully by people who are electrically grounded and with well ion- blown equipment or in such a condition, etc. (2) The protection film is attached to the polarizer with a small amount of glue. If some stress is applied to rub the protection film against the polarizer during the time you peel off the film, the glue is apt to remain on the polarizer. Please carefully peel off the protection film without rubbing it against the polarizer. (3) When the module with protection film attached is stored for a long time, sometimes there remains a very small amount of glue still on the polarizer after the protection film is peeled off. (4) You can remove the glue easily. When the glue remains on the polarizer surface or its vestige is recognized, please wipe them off with absorbent cotton waste or other soft material like chamois soaked with normal-hexane. Alpha Point Ltd. Vernissakatu 8A 01300 Vantaa, Finland Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2 http://www.alpha.fi Ver 0.0 Oct.06. 2000 Page 24/ 24/ 23