For Instructions, please see: http://www.erni.com/DB/derating/DERATING-Instructions.pdf DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b) Current (A] Power Tap connector (SVA) version 2 with 10 contacts (pressfit termination) 80 70 60 50 40 30 20 Base curve [A] Derating curve [A] 10 Temperature [°C] 0 0 Base curve [A] Derating curve [A] © ERNI Elektroapparate GmbH 2006 10 20 57,5 46 30 54,5 43,6 40 51 40,8 50 47 37,6 60 42,5 34 70 37 29,6 80 30,5 24,4 90 22 17,6 All rights reserved. Only for information. Subject to modification without prior notice. 100 10 8 110