EN

Ultrasonic sensors
UNCK 09G8914/KS35A/IO
Ultrasonic distance measuring
sensors
dimension drawing
14,5
6,5
17,4
,5
20,5
30
ø3
,2
LED*
5
3,
ø2
ø
2x
4x
2x
,2
3x M3x5,8
10,2
ø3
23,6
24,5
,2
ø3
2,95
3,25
8,2
15
55
49,6
48
44,8
36,75
8,9 Teach-in
13,8
LED*
19,9
8
15
L
ca. 30
8,6
*LED visible from
opposite only
3,9
M8
2x ø 3,2
general data
photo
scanning range sd
30 ... 200 mm
scanning range close limit Sdc
30 ... 200 mm
scanning range far limit Sde
30 ... 200 mm
repeat accuracy
< 0,5 mm
repeat accuracy (filter active)
< 0,1 mm
resolution
< 0,3 mm
resolution (filter active)
< 0,1 mm
response time ton
< 7 ms
temperature drift
< 2 % of distance to target So
sonic frequency
380 kHz
adjustment
Teach-in and IO-Link
alignment aid
target indication flashing
light indicator
green LED / red LED
connection diagram
electrical data
voltage supply range +Vs
18 ... 30 VDC
current consumption max. (no load)
35 mA
output circuit
push-pull / IO-Link
baud rate
38400
short circuit protection
yes
reverse polarity protection
yes
BN (1)
Push
Pull
+VS
BK (4)
Z
BU (3)
Z
WH (2)
output
(IO-Link)
0V
control /
Teach-in
mechanical data
type
rectangular
housing material
PA 12
width / diameter
8,6 mm
height / length
55 mm
depth
24,5 mm
connection types
flylead connector M8, L=200 mm
ambient conditions
operating temperature
0 ... +60 °C
protection class
IP 67
UNCK 09G8914/KS35A/IO
www.baumer.com
IO-Link: Measuring range, switching
window, absolute/relative teach-in,
service status, object presence,
temperature compensation on/off
23/4/2015