Ultrasonic sensors UNCK 09G8914/KS35A/IO Ultrasonic distance measuring sensors dimension drawing 14,5 6,5 17,4 ,5 20,5 30 ø3 ,2 LED* 5 3, ø2 ø 2x 4x 2x ,2 3x M3x5,8 10,2 ø3 23,6 24,5 ,2 ø3 2,95 3,25 8,2 15 55 49,6 48 44,8 36,75 8,9 Teach-in 13,8 LED* 19,9 8 15 L ca. 30 8,6 *LED visible from opposite only 3,9 M8 2x ø 3,2 general data photo scanning range sd 30 ... 200 mm scanning range close limit Sdc 30 ... 200 mm scanning range far limit Sde 30 ... 200 mm repeat accuracy < 0,5 mm repeat accuracy (filter active) < 0,1 mm resolution < 0,3 mm resolution (filter active) < 0,1 mm response time ton < 7 ms temperature drift < 2 % of distance to target So sonic frequency 380 kHz adjustment Teach-in and IO-Link alignment aid target indication flashing light indicator green LED / red LED connection diagram electrical data voltage supply range +Vs 18 ... 30 VDC current consumption max. (no load) 35 mA output circuit push-pull / IO-Link baud rate 38400 short circuit protection yes reverse polarity protection yes BN (1) Push Pull +VS BK (4) Z BU (3) Z WH (2) output (IO-Link) 0V control / Teach-in mechanical data type rectangular housing material PA 12 width / diameter 8,6 mm height / length 55 mm depth 24,5 mm connection types flylead connector M8, L=200 mm ambient conditions operating temperature 0 ... +60 °C protection class IP 67 UNCK 09G8914/KS35A/IO www.baumer.com IO-Link: Measuring range, switching window, absolute/relative teach-in, service status, object presence, temperature compensation on/off 23/4/2015