FFAK 17PTD1001/L

Photoelectric sensors
FFAK 17PTD1001/L
Liquid level and leakage sensors
dimension drawing
25
ø 12
81
20
G3/8"
SW 30
LED
general data
photo
type
liquid level sensor
light source
pulsed infrared diode
nominal pressure (probe tip)
10 bar
output indicator
LED yellow
sensitivity adjustment
no
wave length
880 nm
measurement type
contact with medium
electrical data
voltage supply range +Vs
10 ... 30 VDC
current consumption max. (no load)
15 mA
voltage drop Vd
< 2 VDC
output function
normally open (NO)
output circuit
PNP
output current
< 200 mA
short circuit protection
no
reverse polarity protection
yes, Vs to GND
connection diagram
BN (1)
PNP
mechanical data
BK (4)
BU (3)
width / diameter
30 mm
height / length
81 mm
thread
G 3/8”
type
cylindrical
material (sensing device)
polysulphone
housing material
polysulphone
connection types
cable 3 pin, 2 m
+VS
output
Z
0V
switched when dipped
ambient conditions
operating temperature
0 ... +65 °C
protection class
IP 67
FFAK 17PTD1001/L
www.baumer.com
24/4/2015