cable sockets Female connector M12 with attached RADOX®-cable, shielded dimension drawing •4-wire, shielded ø 14,8 •shield connected with cap-nut (360°) M12 L •RADOX® halogen-free •for railway applications ø 16 31,7 ø 16 •self-locking cap nut M12 ø 14,8 43,6 L 34,6 General data Nominal current at 40 °C 4A Nominal voltage 250 V Number of positions 4 Insulation resistance ≥ 100 MΩ Length of cable see listing Stripping length of the free conductor end 50 mm Ambient temperature (operation) -40 ... +85 °C type Mat.-No. length straight ESG 34AB0200G ESG 34AB0500G ESG 34AB1000G 11164785 11163204 11164786 2m 5 m 10 m ESW 33AB0200G 11164783 ESW 33AB0500G 11164782 ESW 33AB1000G 11164784 2m 5m 10 m angular General characteristics (grip-body) Coding A-standard Surge voltage category II Pollution degree 3 Degree of protection IP65 Flammability rating according to UL 94 V0 Contact material CuSn Contact surface material Ni/Au Contact carrier material PA 6.6 Material of grip body PA 6.6 Standards/regulations Material, knurls PA 6.6: Fire protection in rail vehicles requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) Zinc die-cast, nickel-plated Sealing material NBR Status display no Insertion/withdrawal cycles ≥ 100 Torque 0.4 Nm (M12 connector) other lengths on request pin assignment 3 4 2 1 1 2 3 4 = = = = WH 1 WH 2 WH 3 WH 4 contact assignment Strands 1 Socket 1 WH 2 WH 2 3 WH 3 4 WH 4 Technical specifications subject to change Page 1/2 Baumer Electric AG P.O. Box Hummelstrasse 17 CH-8501 Frauenfeld Phone +41 (0)52 728 11 22 Fax +41 (0)52 728 11 44 Drawn: 01.03.16/in Checked: 07.03.16/zi Released: 07.03.16/zi Last change: www.baumer.com cable sockets Female connector M12 with attached RADOX®-cable, shielded Conductor data Cable type RADOX® halogen-free black, shielded Conductor cross section 4 x 0,5 mm2 AWG signal line 20 Conductor structure signal line 19x 0.18 mm Core diameter including insulation 1,43 mm Wire colors white 1, white 2, white 3, white 4 Overall twist 4 wires, twisted Shielding tinned copper braided shield External sheath, color black External cable diameter D 5,4 ±0,3 mm Minimum bending radius, fixed installation 3xD Minimum bending radius, flexible installation 4xD Cable weight 56 kg/km Outer sheath, material EC-X Material conductor insulation EC-X Conductor material tin-plated Cu litz wires Conductor resistance ≤ 40,1 Ω/km Nominal voltage, cable Halogen-free 600 V AC (Core-ground, U0) 1000 V AC (Core-ground, U) ≤ 720 V AC (core-ground) ≤ 1200 V AC (Core-ground, Um) ≤ 900 V DC (Core-ground, V0) ≤ 1500 V DC (core-core) 3500 V AC (50 Hz, 5 min.) 8400 V DC (50 Hz, 5 min.) BS 6853 (Category Ia, Ib, II) GM/RT 2130 (Category Ia, Ib, II) EN 45545 (Risk level HL1 - HL3) DIN 5510 (Fire protection level 1, 2, 3, 4) NF F16-101 (Category A1, A2, B) NF F16-101 (Class C/F0) NFPA 130 UNI CEI 11170 (Risk level LR1 - LR4) EN 60332-1-2 EN 50266 EN 50305, 9.1.2 NF C32-070, 2.1 NF C32-070, 2.2 UL 1685, 12 (FT4) in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01) according to EN 50267-2-1 Resistance to oil according to IRM 902, 72 h at 100 °C Other resistance resistance to fuels according to IRM 903, 168 h at 70 °C BS 6853 D.8.7 EN 61034-2 UL 1685, 12 (FT4) EN 50267-2-2 Test voltage, cable Fire protection in rail vehicles Flame resistance Concentration of fumes Fume corrosiveness Fume toxicity BS 6853 B.1 EN 50305, 9.2 -50 °C ... 120 °C (cable, fixed installation) -25 °C ... 90 °C (cable, flexible installation) Ambient temperature (operation) Technical specifications subject to change Page 2/2 Baumer Electric AG P.O. Box Hummelstrasse 17 CH-8501 Frauenfeld Phone +41 (0)52 728 11 22 Fax +41 (0)52 728 11 44 Drawn: 01.03.16/in Checked: 07.03.16/zi Released: 07.03.16/zi Last change: www.baumer.com