AGILENT N2102B

Agilent
PXIT 10.3125 Gb/s Pattern Generator N2102B
and PXIT Synthesizer N2099A
Data Sheet
The N2102B PXIT pattern generator is a 2-slot PXI module capable of generating a
number of industry standard patterns, with very low jitter, from 622 Mb/s to 10.3125 Gb/s.
The N2102B requires an external clock source for operation at these rates.
The N2099A PXIT synthesizer is a 2-slot PXI module with dual RF outputs, tunable
over a 2 GHz range. There are three options available that cover different frequency
ranges depending on the required application.
The N2099A is the ideal clock source for the N2102B.
Both instruments form part of the Agilent PXIT family of modules. Other modules
available include the N2100B PXIT DCA and the N2101B PXIT BERT which can
also be used (via its at rate clock out) to drive the N2102B PXIT pattern generator.
PXIT 10.3125 Gb/s
Pattern Generator
N2102B
Features
•
•
•
•
•
•
•
•
•
PRBS generations 2n – 1, (n = 7, 9, 11, 15, 23, 31)
User selectable data patterns: K28.5, K28.7, CRPAT
Single error and error rate injection
Differential data output
SMA trigger output (clock/128, pattern, user defined burst enable )
SMA clock input and output
Requires external clock
2-slot PXI module
User defined patterns
▫ 2048 bits maximum length
▫ 16 Kbytes if pattern length is divisable by 64.
Specifications
Parameter
Specification
Bit rate operation
Output rise/fall time (20% - 80%)
Output intrinsic jitter
Output voltage range (single-ended)
Output voltage resolution
Pattern trigger/clock output voltage
Front panel connectors
Clock input voltage range
622 Mb/s to 10.3125 Gb/s
25 ps (max) 22 ps characteristic
2.5 ps RMS (max) 1.5 RMS ps characteristic
250 mV to 1 V pp
5 mV
1 V pp (characteristic)
SMA
500 mV to 1 V pp (characteristic)
Note: Unless otherwise stated all signals are AC coupled and 50 Ω terminations are expected
User friendly configuration screen
The N2101B eye output at 10.3125 Gb/s viewed
on the DCA-J
2
PXIT Synthesizer
N2099A
The N2099A synthesizer is a 2-slot PXI instrument. This permanent magnet YIG
(PMYTO) based synthesizer can be tuned over a 2 GHz frequency range.
ActiveX drivers provide an easy to use software interface and a graphical user
interface is provided for manual operation of the module.
Features
•
•
•
•
•
•
•
Two frequency ranges available between 4.25 and 11.5 GHz
2 GHz tuning range
2 outputs
10 MHz reference output
Excellent phase noise performance
Non-volatile storage of set frequency – unit powers up at previously set frequency
2-slot PXI module
Specifications
Parameter
Specification
Output frequency (center)
Tuning range
Output power minimum
5.25 and 10.5 GHz
±1.0 GHz
+8 dBm (4, 5 and 6 GHz) characteristic
+6 dBm (9, 10 and 11 GHz) characteristic
±3 dB
1 kHz
100 kHz
250 kHz
100 ms typical
50 Ω
10 MHz
Power variation over temp/freq
Step size minimum
• Option 052
• Option 105
Switching speed, 100 MHz step
Output impedance
External reference osc output freq (TCXO)
Software
Both instruments and accompanying software fully comply with PXI
specifications. To achieve this, a Windows® application is provided through
which the user can control either without any user development.
To ease program development and compatibility, an ActiveX control is supplied
allowing program development in any ActiveX compliant programming
environment. These include Visual C++, Visual Basic, C#, Excel®, LabVIEW™
and many other environments.
Software features include:
• Simple programming through the ActiveX interface
• A Windows application control panel
• Requires VISA distribution software (from National Instruments)
3
Typical Configuration
RF ouput (clock in to BERT)
www.agilent.com
Online assistance:
www.agilent.com/find/pxit
10M hz ref (clock in to DCA)
For more information on Agilent Technologies’ products, applications or services,
please contact your local Agilent office.
The complete list is available at:
www.agilent.com/find/contactus
SFP module
Rx
Optical signal
Tx
Differential electrical signal
Test board
Ordering
N2099B PXIT synthesizer
N2102B PXIT pattern generator
Option 052 4.25 GHz to 6.25 GHz
Option 105 9.5 GHz to 11.5 GHz
Option 300 622 Mb/s to 10.3125 Gb/s
Remove all doubt
www.agilent.com/find/emailupdates
Get the latest information on the
products and applications you select.
www.agilent.com/find/agilentdirect
Quickly choose and use your test
equipment solutions with confidence.
Microsoft, EXCEL and Visual Basic are U.S.
registered trademarks of Microsoft Corporation.
LabVIEW is a trademark of
National Instruments Corporation.
Our repair and calibration services will get
your equipment back to you, performing
like new, when promised. You will get
full value out of your Agilent equipment
throughout its lifetime. Your equipment
will be serviced by Agilent-trained technicians using the latest factory calibration
procedures, automated repair diagnostics
and genuine parts. You will always have the
utmost confidence in your measurements.
Agilent offers a wide range of additional
expert test and measurement services for
your equipment, including initial start-up
assistance onsite education and training,
as well as design, system integration, and
project management.
For more information on repair and
calibration services, go to
www.agilent.com/find/removealldoubt
Americas
Canada
Latin America
United States
(877) 894-4414
305 269 7500
(800) 829-4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Thailand
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
1 800 226 008
Europe & Middle East
Austria
Belgium
Denmark
Finland
France
01 36027 71571
32 (0) 2 404 93 40
45 70 13 15 15
358 (0) 10 855 2100
0825 010 700*
*0.125 €/minute
Germany
07031 464 6333
Ireland
1890 924 204
Israel
972-3-9288-504/544
Italy
39 02 92 60 8484
Netherlands
31 (0) 20 547 2111
Spain
34 (91) 631 3300
Sweden
0200-88 22 55
Switzerland
0800 80 53 53
United Kingdom
44 (0) 118 9276201
Other European Countries:
www.agilent.com/find/contactus
Revised: August 14, 2008
Product specifications and descriptions in this
document subject to change without notice.
© Agilent Technologies, Inc. 2007, 2008
Printed in USA, October 13, 2008
5989-7067EN