Features • 5 Smart Card Interfaces • • • • • • • • – Compliance with ISO 7816, EMV2000, GIE-CB and GSM Standards – Direct Connection to the Smart Cards Logic Level Shifters Short Circuit Current Limitation 4kV+ ESD Protection (MIL/STD 883 Class 3) – 1 or 2 Master Smart Card interfaces Synchronous Card support (with C4 and C8 Contacts) Card Detection and Automatic de-activation sequence on card extraction – 1 to 4 SAM/SIM cards (15 to 30mA each) – Programmable Voltage for each smart card Class A: 5V ±0.4V at 60 mA (±0.25V at 65 mA with VCC= 5V±10%) Class B: 3V ±0.2V at 60 mA Class C: 1.8V ±0.14V at 40mA – Low Ripple Noise: < 200 mV – Programmable Activation Sequence – Automatic de-activation on card power-fail or over-current and system power-fail – Card Clock Stop High or Low for Card Power-down Modes Versatile Host Interface – Two Wire Interface (TWI) Link at 400kbit/s Programmable Address allow up to 4 AT83C26 on the bus – Programmable Interrupt Output Reset Output Includes – Power-On Reset (POR) – Power-Fail Detector (PFD) Extended Voltage Operation: 3 to 5.5V Low Power Consumption – 5 mA Maximum Operating Current (without Smart Card) – 150 mA Maximum In-rush Current (each DC/DC) – 30 µA Typical Power-down Current (without Smart Card) 4 to 48 MHz Clock Input System clock derived from the external clock input Industrial Temperature Range: -40 to +85°C Packages: QFN48, VQFP48 Smart Card Reader Interface With Power Management AT83C26 Description The AT83C26 is a smart card reader interface IC for smart card reader/writer applications such as EFT/POS terminals and set top boxes. It enables the management of any type of smart card from any kind of host. Up to 4 AT83C26 can be connected in parallel thanks to the programmable TWI address. Its high efficiency DC/DC converters and low quiescent current in stand-by mode make it particularly suited to low power and portable applications. The reduced bill of material allows to lower significantly the system size and cost. A sophisticated protection system guarantees timely and controlled shutdown upon error conditions. 7511B–SCR–10/05 Acronyms TWI: Two Wire Interface POR: Power On Reset PFD: Power Fail Detect ART: Automatic Reset Transition ATR: Answer To Reset Block Diagram VCC VSS CVSSB CVCCB CVCCINB LIB LIA CVSS1 CVCCIN1 DC/DC Converter A BYPASS DC/DC Converter B Voltage supervisor POR/PFD EVCC RESET CVCC1 LDO CVCC2 LDO CVCC3 LDO CVCC4 LDO CVCC5 INT A2/CK, A1/RST CPRES1 SCL TWI Controller SDA CRST1 Main Control & Logic Unit smart card 1 Timer 16 bits CIO1 SC1 CC41 CC81 CCLK1 CPRES2 CRST2 smart card 2 I/O1 I/O2 I/0 Selection AUX1 AUX2 CIO2 SC2 CCLK2 Analog Drivers CC42, see (1) CC82, see (1) CRST3, see (1) SAM/SIM 1 CIO3, see (1) SC3 CCLK3 Clock Circuit CCLK Clock Controller CRST4 SAM/SIM 2 CIO4 SC4 CCLK4 CLK CRST5 SAM/SIM 3 CIO5 SC5 CCLK5 Note: 2 1. CRST3/CC82 are on the same pin. CIO3/CC42 are on the same pin. If complete Smart card 2 interface is used, SAM/SIM3 isn’t available. Respectively, if SAM/SIM3 is used, complete Smart card 2 isn’t available. AT83C26 7511B–SCR–10/05 AT83C26 Pin Description Pinout (Top View) CIO2 CCLK2 CRST2 CVCC2 CVCCINB CPRES2 RESET CVCCB CVCCB LIB CVSSB EVCC VQFP48 Pinout 48 47 46 45 44 43 42 41 40 39 38 37 36 1 2 INT CLK A2/CK 33 A1/RST 32 AUX1 31 AUX2 30 IO1 29 IO2 28 SCL 27 SDA 26 BYPASS 25 VSS 35 34 3 4 5 6 VQFP 48 TOP VIEW 7 8 9 10 VCC 11 12 13 14 15 16 17 18 19 20 21 22 23 24 CC81 CC41 CIO1 CCLK1 CRST1 CVCCIN1 CPRES1 CVCC1 CVCC1 LIA CVSS1 CVCC3 CRST3/CC82 CCLK3 CIO3/CC42 CVCC4 CRST4 CCLK4 CIO4 CIO5 CCLK5 CRST5 CVCC5 CIO2 CCLK2 CRST2 CVCC2 CVCCINB CPRES2 RESET CVCCB CVCCB LIB CVSSB EVCC QFN48 Pinout 48 47 46 45 44 43 42 41 40 39 38 37 36 1 2 35 34 3 33 4 5 6 QFN 48 TOP VIEW 7 8 9 10 32 31 30 29 28 27 26 INT CLK A2/CK A1/RST AUX1 AUX2 IO1 IO2 SCL SDA BYPASS VSS VCC 11 12 25 13 14 15 16 17 18 19 20 21 22 23 24 CC81 CC41 CIO1 CCLK1 CRST1 CVCCIN1 CPRES1 CVCC1 CVCC1 LIA CVSS1 CVCC3 CRST3/CC82 CCLK3 CIO3/CC42 CVCC4 CRST4 CCLK4 CIO4 CIO5 CCLK5 CRST5 CVCC5 3 7511B–SCR–10/05 Signals Table 1. Ports Description VQFP48 or QFN48 Pad Name Pin number Pad Internal ESD Limits Pad Type 4kV+ PWR Description Power Supply 1 CVCC3 2 CRST3/CC82 CVCC3 4kV+ 3 CCLK3 CVCC3 4kV+ 4 CIO3/CC42 CVCC3 4kV+ 5 CVCC4 6 CRST4 7 I/O pull up O I/O pull up VCC pin for SC3 interface. See SC2_CFG1 register: If SC2_FULL bit = 0, CRST pin for SC3 interface. If SC2_FULL bit = 1, CC8 pin for SC2 interface. CCLK pin for SC3 interface. See SC2_CFG1 register: If SC2_FULL bit = 0, CIO pin for SC3 interface. If SC2_FULL bit = 1, CC4 pin for SC2 interface. 4kV+ PWR VCC pin for SC4 interface. CVCC4 4kV+ O RST pin for SC4 interface. CCLK4 CVCC4 4kV+ O CCLK pin for SC4 interface. 8 CIO4 CVCC4 4kV+ 9 CIO5 CVCC5 4kV+ 10 CCLK5 CVCC5 4kV+ O CCLK pin for SC5 interface. 11 CRST5 CVCC5 4kV+ O RST pin for SC5 interface. 12 CVCC5 4kV+ PWR VCC pin for SC5 interface. 13 CC81 CVCC1 4kV+ 14 CC41 CVCC1 4kV+ 15 CIO1 CVCC1 4kV+ 16 CCLK1 CVCC1 4kV+ O CCLK pin for SC1 interface. 17 CRST1 CVCC1 4kV+ O RST pin for SC1 interface. 18 CVCCIN1 4kV+ PWR 19 CPRES1 VCC 4kV+ I/O pull up I/O pull up I/O pull up I/O pull up I/O pull up I pull up CIO pin for SC4 interface. CIO pin for SC5 interface. CC8 pin for SC1 interface. CC4 pin for SC1 interface. CIO pin for SC1 interface. This pin must be connected to CVCC1 pins next to the package. Card presence for SC1 interface. An internal pull up to VCC can be activated in the pad if necessary using PULLUP1 bit in SC1_CFG1 register (activated by default). VCC pin for SC1 interface. 4 20 CVCC1 4kV+ PWR 21 CVCC1 4kV+ PWR The two CVCC1 pins are connected together near the package. Only one wire goes to the smart card connector. The reason of two CVCC1 pins is to reduce noise. VCC pin for SC1 interface. AT83C26 7511B–SCR–10/05 AT83C26 Table 1. Ports Description (Continued) VQFP48 or QFN48 Pad Name Pin number Pad Internal ESD Limits Pad Type Description Power Supply DC/DCA input. LIA must be tied to VCC pin through an external coil (typically 10µH) and provides the current for the charge pump of the DC/DCA converter. 22 LIA 2kV PWR 23 CVSS1 2kV GND 24 VCC 2kV PWR VCC is used to power the internal voltage regulators and I/O buffers. 25 VSS 2kV GND Ground. 26 BYPASS VCC 2kV I 27 SDA VCC 2kV 28 SCL VCC 2kV 29 IO2 EVCC 2kV 30 IO1 EVCC 2kV 31 AUX2 EVCC 2kV 32 AUX1 EVCC 2kV I/O It may be directly connected to VCC if the step-up converter is not used (see STEPREGA bit in SC1_CFG4 register and see minimum VCC values in Table 50.for class A and Table 51. for class B) DC/DCA input. This pin must be directly connected to the VSS of power supply. A high level on this pin activates a low power consumption mode with internal regulator bypassed. Micro controller interface function: TWI serial data. open drain An external pull up must be connected on SDA pin (4.7kOhms). I/O Micro controller interface function: TWI clock. open drain An external pull up must be connected on SCL pin (4.7kOhms). I/O pull up I/O pull up I/O pull up I/O pull up The behavior of this pin depends on IOSEL[3/0] bits values (see IO_SELECT register). The behavior of this pin depends on IOSEL[3/0] bits values (see IO_SELECT register). The behavior of this pin depends on IOSEL[3/0] bits values (see IO_SELECT register). The behavior of this pin depends on IOSEL[3/0] bits values (see IO_SELECT register). The TWI address depends on the value present on this pin at reset. 33 A1/RST EVCC 2kV I If CRST transparent mode is selected, the A1/RST signal is connected to CRST1 or CRST2 pins (see CRST_SEL1 and CRST_SEL2 bits respectively in SC1_CFG4 and SC2_CFG2 registers). The TWI address depends on the value present on this pin at reset. 34 A2/CK EVCC 2kV I If CCLKn transparent mode is selected, the A2/CK signal is connected to CCLKn pins (with n=1 to 5). See CKSn[2:0] bits respectively in SC1_CFG1, SC2_CFG2, SC3_CFG2, SC4_CFG2, SC5_CFG2 registers. 35 CLK EVCC 2kV 36 INT VCC 2kV I O open drain Master clock. Interruption status. An internal pull up to VCC can be activated in the pin if necessary using INT_PULLUP bit in SC1_CFG4 (deactivated by default). Extra supply voltage (Micro controller power supply). EVCC is used to supply the internal level shifters of host interface pins. 37 EVCC PWR EVCC is connected to the host power supply. EVCC voltage can be directly connected to VCC if the host power supply and the AT83C26 power supply is the same. 5 7511B–SCR–10/05 Table 1. Ports Description (Continued) VQFP48 or QFN48 Pad Name Pin number 38 Pad Internal ESD Limits Pad Type Description Power Supply CVSSB GND DC/DCB input. This pin must be directly connected to the VSS of power supply. DC/DCB input. 39 LIB 2kV PWR LIB must be tied to VCC pin through an external coil (typically 10µH) and provides the current for the charge pump of the DC/DCB converter. It may be directly connected to VCC if the step-up converter is not used (see STEPREGB bit in DCDCB register and see minimum VCC values in Table 53.for class A and Table 54. for class B) DC/DCB output. 40 CVCCB 2kV PWR The two CVCCB pins are connected together near the package. CVCCB pin is only used for DC/DCB voltage measurements.The reason of two CVCCB pins is to reduce noise. 41 CVCCB 2kV PWR DC/DCB output. Micro controller interface function: reset signal. 42 6 RESET 43 CPRES2 44 CVCCINB 45 CVCC2 46 CRST2 47 48 VCC VCC 2kV 4kV+ I/O • power on reset • A low level on this pin keeps the AT83C26 under reset even if applied on power-on. It also resets the AT83C26 if applied when the AT83C26 is running. • Asserting RESET open drain I pull up Card presence for SC2 interface. An internal pull to VCC can be activated in the pad if necessary using PULLUP2 bit in SC2_CFG1 register (activated by default). PWR This pin must be connected to CVCCB pins next to the package. 4kV+ PWR VCC pin for SC2 interface. CVCC2 4kV+ O CRST pin for SC2 interface. CCLK2 CVCC2 4kV+ O CCLK pin for SC2 interface. CIO2 CVCC2 4kV+ I/O pull up CIO pin for SC2 interface. AT83C26 7511B–SCR–10/05 AT83C26 Pad Type Description To simplify the understanding of Figure 1. to Figure 8., a shortcut is possible by replacing the weak transistor by a 100k Ohms pull-up resistor, the medium transistor by a 10k Ohms pull-up resistor and the strong transistor by a 1k Ohms pull-up resistor. Input/Output with Pull-up Configuration (IO1, IO2, AUX1, AUX2) This output type can be used as both an input and output without the need to reconfigure the port. This is possible because when the port outputs a logic high, it is weakly driven, allowing an external device to pull the pin low. When the port outputs a logic low state, it is driven strongly and able to sink a fairly large current. Figure 1. Input/Output with Pull-up Configuration P 2 DCCLK CLOCK DELAY P Strong Keep PMOS Pin Port latch Data N NMOS Input Data Input/Output with Pull-up Configuration (CIOn with n = 1, 2, 3, 4, 5) and (CC4n, CC8n with n = 1, 2) Figure 2. Input/Output with Pull-up Configuration P 2 DCCLK CLOCK DELAY P Strong Medium PMOS Slew control with CIOn_SLEW_CTRL bits (n= 1 to 5) Port latch Data Pin N NMOS Input Data 7 7511B–SCR–10/05 Input/Output with Open Drain Configuration (SDA, SCL, RESET) Figure 3. Input/Output with Open Drain Configuration Pin N Port latch Data NMOS Input Data Output Configuration (CCLKn with n = 1, 2, 3, 4, 5) Figure 4. Output Configuration P Strong PMOS Slew control with CIOn_SLEW_CTRL bits Pin N Port latch Data NMOS Output Configuration (CRSTn with n = 1, 2, 3, 4, 5) Figure 5. Output Configuration P Strong PMOS Pin Port latch Data N NMOS 8 AT83C26 7511B–SCR–10/05 AT83C26 Open drain Output with programmable pull-up Configuration (INT) Figure 6. Open Drain Output with programmable pull-up P Weak INT_PULLUP bit Pin N Port latch Data NMOS Input Configuration (A1, A2, CLK, BYPASS) Figure 7. Input Input Data Pin Input with programmable pull-up Configuration (CPRES1, CPRES2) Figure 8. Input with programmable pull-up P INT_PULLUP bit Weak Input Data Pin 9 7511B–SCR–10/05 Operational Modes TWI Bus Control The Atmel Two-wire Interface (TWI) interconnects components on a unique two-wire bus, made up of one clock line and one data line with speeds of up to 400 Kbits per second, based on a byte-oriented transfer format. The TWI-bus interface can be used: – To configure the AT83C26 – To select interface – To select the operating mode of the card: 1.8V, 3V or 5V – To configure the automatic activation sequence – To start or stop sessions (activation and de-activation sequences) – To initiate a warm reset – To control the clock to the card in active mode – To control the clock to the card in stand-by mode (stop LOW, stop HIGH or running) – To enter or leave the card stand-by or power-down modes – To select the interface (connection to the host I/O/C4/C8) – To request the status (card present or not, over-current and out of range supply voltage occurrence) – To drive and monitor the card contacts by software – To accurately measure the ATR delay when automatic activation is used – Re-use the AT83C24 command set for the first DC/DC and smart card interface with the following changes: •CKS extended to CONFIG2[0:3], CKS=8 selects CLK/3 and CKS>8 is reserved •The slave address byte for TWI write commands is 0100 A2A110 and 0100 A2A111 for TWI read commands TWI Commands Frame Structure The structure of the TWI bus data frames is made of one or a series of write and read commands completed by STOP. Write commands to the AT83C26 have the structure: ADDRESS BYTE + COMMAND BYTE + DATA BYTE(S) Read commands to the AT83C26 have the structure: ADDRESS BYTE + DATA BYTE(S) The ADDRESS BYTE is sampled on A2/CK and A1/RST after each reset (hard/soft/general call) but A2/CK, A1/RST can be used for transparent mode after the reset. 10 AT83C26 7511B–SCR–10/05 AT83C26 Figure 1. Data transfer on TWI bus SDA acknowledgement from slave command and/or data Address byte SCL 1 2 3 4 5 7 6 8 9 start condition Address Byte stop condition The first byte to send to the device is the address byte. The device controls if the hardware address (A2/CK, A1/RST pins on reset) corresponds to the address given in the address byte (A2, A1 bits). If the level is not stable on A2/CK pin at reset, the user has to manage the possible address taken by the device. Figure 2. Address Byte b7 b6 b5 b4 b3 b2 b1 0 1 0 0 A2 A1 1 b0 R/W Slave Address on 7 Bits 1 for READ Command 0 for WRITE Command Up to 4 devices can be connected on the same TWI bus. Each device is configured with a different combination on A2/CK, A1/RST pins. The address byte of each device for read/write operations are listed below. Table 2. Address Byte Values A2 (A2/CK pin) A1 (A1/RST pin) Address Byte for Read Command Address Byte for Write Command 0 0 0x43 0x42 0 1 0x47 0x46 1 0 0x4B 0x4A 1 1 0x4F 0x4E 11 7511B–SCR–10/05 RESET pin The TWI ADDRESS BYTE is sampled on A2/CK and A1/RST after a rising edge on RESET pin. The delay between the rising edge and the sampling of A2/CK and A1/RST is t1. The value for t1 is 22 CLK period. The minimum value for t2 is 40 CLK period. During the t2 time, the TWI bus is not ready to receive a command. The CLK period depends on the frequency of the signal on CLK pin. The RESET pin is an I/O with Open Drain. The host IO pin connected to RESET must be an I/O with open drain (with external pull-up) or an I/O with internal pull up (without external pull-up). Figure 3. Timings after reset Sampling of TWI address t1 RESET SDA t2 Address byte BYPASS pin A high level on this pin activates a low power consumption mode. At reset, the level on this pin must be fixed (VSS or VCC). Before to set BYPASS pin, SHUTDOWNA and SHUTDOWNB bits must be set. If SHUTDOWNA bit is set, DCDCA is switched off. If SHUTDOWNB bit is set, DCDCB is switched off. If SHUTDOWNA and SHUTDOWNB bits are set, the regulator is switched off. If BYPASS pin is at a high level, the bandgaps are switched off. Smart Card Interfaces The AT83C26 enables the management of up to 5 smart card interfaces. Due to shared IOs between SC2 and SC3, the user should choose between a full SC2 interface (with CC4 and CC8) or SC3 interface. The SC2_FULL bit in SC2_CFG1 register is used to select the SC2/SC3 interfaces configuration. 12 AT83C26 7511B–SCR–10/05 AT83C26 Table 3. SC2 and SC3 shared IOs Pin name SC2_FULL = 1 SC3 interface not available SC2_FULL = 0 SC2 without CC4and CC8 + SC3 interface CPRES2 CPRES2 CPRES2 CRST2 CRST2 CRST2 CIO2 CIO2 CIO2 CCLK2 CCLK2 CCLK2 CRST3/CC82 CC82 CRST3 CIO3/CC42 CC42 CIO3 CCLK3 unused CCLK3 DCDC Converters The DC/DC A converter is used to provide smart card voltage for the SC1 interface (CVCC1). The DC/DC B converter is used to provide smart card voltage for the SCn interfaces (n=2, 3, 4, 5). DC/DC converters need a clock of 4MHz (see Section “Clock Controller”). Two internal oscillators (one for each converter) provide the DC/DC clocks. The DC/DCB output is connected on 4 LDO regulators (Low Drop Output) to generate CVCCn voltage (n=2, 3, 4, 5). Clock Controller The clock controller outputs six clocks: 1. Five clocks for CCLK1, CCLK2, CCLK3, CCLK4 and CCLK5. Four different sources can be used: CLK pin, DCCLK signal, CARDCKn bit (n=1, 2, 3, 4, 5) or A2/CK. 2. A DCCLK clock used for pads and deactivation sequence. Clock controller for SCn (n=1, 2, 3, 4, 5) The transparent mode with A2/CK pin is available on SCn interface. The CKSn[2:0] register is used to select this transparent mode between A2/CK and CCLKn. The bit CKSTOPn must be cleared to have CCLKn running according to CKSn[2:0]. 13 7511B–SCR–10/05 Figure 4. Clock Block Diagram with Software Activation Internal oscillators CLK DC/DCA and B DCCLK DCK[2:0] CKSn[2:0] A2/CK 0 CARDCKn bit CCLKn 1 CKSTOPn bit CRST controller CRSTn for SCn interface (n=1, 2) The CRSTn output pin is driven by the CARDRSTn bit value or by A1/RST pin. Three modes are available: • If the ARTn bit is reset, CRSTn pin is driven by CARDRSTn bit. • If the ARTn bit is set, CRSTn pin is controlled and follows the “Automatic Reset Transition” (see Activation sequence page 25). • A transparent mode with A1/RST pin. Figure 5. CRSTn Block Diagram CARDRSTn bit 0 0 CARDRSTn bit tb delay CRSTn 1 1 ARTn bit A1/RST 14 CRST_SELn bit AT83C26 7511B–SCR–10/05 AT83C26 CRSTn for SCn interface (n= 3, 4, 5) The CRSTn output pin is driven by the CARDRSTn bit value (see SCn_CFG2 register). Two modes are available: • If the ARTn bit is reset, CRSTn pin is driven by CARDRSTn bit. • If the ARTn bit is set, CRSTn pin is controlled and follows the “Automatic Reset Transition” (see Activation sequence page 25). Figure 6. CRSTn Block Diagram CARDRSTn bit 0 CRSTn CARDRSTn bit 1 tb delay ARTn bit If SC2_FULL=1, the SC3 interface is not available. CIO, CC4, CC8 controller CIO1, CC41, CC81 controller for SC1 interface The CIO1, CC41, CC81 output pins are driven respectively by CARDIO1, CARDC41, CARDC81 bits values or by I/O1, I/O2, AUX1or AUX2 signals. This selection depends of the IODIS1 bit value (SC1_INTERFACE register) and of IOSEL[3:0] bits value (IO_SELECT register). Figure 7. CIO1, CC41, CC81 Block Diagram 0 CARDIO1 bit IO1 IO2 AUX1 AUX2 HiZ control 1 0 Multiplex CARDC41 bit IODIS1 bit CC41 1 0 CARDC81 bit CIO1 CC81 1 IOSEL[3:0] If IODIS1 is set, the CARDIO1 bit value is output on CIO1.The input selected by IOSEL for CIO1 is in High impedance state. CC41 and CC81 have the same behavior. If IODIS1 is reset, data are bidirectional between the I/O1, I/O2, AUX1, AUX2 pins (see IO_SELECT register) and CIO1, CC41, CC81 pins. 15 7511B–SCR–10/05 CIO2, CC42, CC82 controller for SC2 interface Figure 8. CIO2, CC42, CC82 Block Diagram 0 CARDIO2 bit IO1 IO2 AUX1 AUX2 HiZ control 1 0 Multiplex CARDC42 bit IODIS2 bit CC42 1 0 CARDC82 bit CIO2 CC82 1 IOSEL[3:0] The SC2_FULL bit must be set to use CC42 and CC82. CIOn controller for SCn interface (n=3, 4, 5) The CIOn output pin is driven by CARDIOn bit values or by I/O1, I/O2, AUX1 or AUX2 signals. This selection depends of the IODISn bit value. If IODISn is reset, data are bidirectional between the I/O1, I/O2, AUX1, AUX2 pins (see IO_SELECT register) and CIOn pins. Figure 9. CIOn Block Diagram IO1 IO2 AUX1 AUX2 HiZ control Multiplex 0 CARDIOn bit IODISn bit CIOn 1 IOSEL[3:0] CIOn (n=1 to 5), CC41, CC81, CC42, CC82 transparent mode description Two modes are available on CIOn, CC4n, CC8n signals: • Bit control (a bit controls the output pin) • Transparent mode (IO signal and CIO are linked after level shifter) According to IO_SELECT register value and IODISn bits values, one of 4 input pins (IO1, IO2, AUX1 or AUX2) is linked to the selected output. The idle state is the high level. Each signal is bidirectional. 16 AT83C26 7511B–SCR–10/05 AT83C26 Transparent mode arbitration system The first between IO and CIO to force a low level becomes the master. The slave signal is grounded after t1 delay: t1 max = 2* (CLK period). Figure 10. Bidirectional mode IO master slave t2 CIO slave master t1 t1 t1 t1 The minimum delay for a pulse at 0 or 1 to be detected is between 0.5 and 1.5 CLK period (depending on arrival time). If IO and CIO are both grounded, CIO becomes the master. The minimum delay to switch of master without electrical conflict is equal to: t2 min = 4 * (CLK period) + 2 * (DCCLK period) * (CLK period). If a master switch appears before this minimum delay, the electrical conflict delay is: t2 = 2 * (DCCLK period) * (CLK period) Figure 11. Electrical conflict CIO pad becomes output IO master slave t2 CIO slave master t1 17 7511B–SCR–10/05 CCLKn and CIOn (n=1 to 5) slew rate control Three registers SLEW_CTRL_1, SLEW_CTRL_2 and SLEW_CTRL_3 control the slew rate of the CIOn and CCLKn signals. Each signal has 2 control bits. An automatic mode is proposed. The VCARDn[1:0] value is used to automatically adjust the slew rate. For specific cases, like long wires between AT83C26 and smart card connector for example, the user can forced the slew rate. The rising edge and the falling edge are modified with the slew rate control for CCLKn. Only the rising edge is modified on CIOn with the slew rate control. See Table 63. to Table 68. in Electrical Characteristics. 18 AT83C26 7511B–SCR–10/05 AT83C26 Card Presence Detection Card presence detection for SC1 interface The card presence signal is connected on the CPRES1 pin. The polarity of card presence contact is selected with the CARDDET1 bit (see SC1_CFG1 register). A programmable filtering is controlled with the CDS1[2-0] bits. The internal pull-up on the CPRES1 pin can be disconnected in order to reduce the consumption. An external pull-up must be connected to Vcc. The PULLUP1 bit (see SC1_CFG1 register) controls this feature. Figure 12. SC1 presence Input VCC VCC VCC External Pull-up Resistor PULLUP1 Bit Card Presence Contact CARDDET1 Bit = 1 Closed = 0 Open = 1 No Card if CPRES1 = 0 = 0 No Card if CPRES1 = 1 CPRES1 FILTERING VCC Card Presence Contact = 1 Closed = 0 Open External Pull-down Resistor CDS1[2-0] CARDIN1 bit INT_PULLUP Bit = 1 Card Inserted = 0 No Card INT VSS VSS If the card presence contact is connected to Vcc, the internal pull-up must be disconnected and an external pull-down must be connected to the CPRES1 pin. An interrupt can be generated if a card is inserted or extracted (see Section “Interrupts”, page 30). Card Presence Detection for SC2 interface Figure 13. SC2 presence Input VCC VCC External Pull-up Resistor VCC CARDDET2 Bit PULLUP2 Bit Card Presence Contact = 1 Closed = 0 Open = 1 No Card if CPRES2 = 0 = 0 No Card if CPRES2 = 1 CPRES2 FILTERING VCC Card Presence Contact External Pull-down Resistor INT_PULLUP Bit = 0 Closed = 1 Open CDS2[2-0] CARDIN2 bit ITDIS2 Bit INT VSS = 1 Closed = 0 Open = 1 Card Inserted = 0 No Card VSS 19 7511B–SCR–10/05 DC/DC converters DC/DC A converter The DC/DC A converter is controlled by VCARD1[1:0], SHUTDOWNA, ICCADJA, STEPREGA, VCARD_OK1 and DEMBOOSTA[1:0] bits. The DC/DC A converter cannot be switched on while the CPRES1 pin remains inactive. If CPRES1 pin becomes inactive while the DC/DC A converter is operating an automatic shut down sequence of the DC/DC A converter is initiated by the electronics. A write operation in VCARD1[1:0] (0x01, 0x02, 0x03) starts the DC/DC. When the output voltage remains within the voltage range specified by VCARD1[1:0], the VCARD_OK1 bit is set. After a deactivation sequence (card extraction, DC/DC output voltage out of range, SHUTDOWNA bit =1...) the DC/DC A converter is automatically stopped. It is mandatory to switch off the DC/DC A converter before entering in Power-down mode. The DC/DC A Converter can work in two different modes which are selected by STEPREGA bit: • Pump Mode (STEPREGA = 0): an external inductance of 10 µH must be connected between pins LIA and VCC. VCC can be higher or lower than CVCC1. • Regulator mode (STEPREGA = 1): no external inductance is required but VCC must be always higher than CVCC+0.3V. The current drawn from power supply by the DC/DC A converter is controlled during the startup phase in order to avoid high transient current mainly in Pump Mode which could cause the power supply voltage to drop dramatically. This control is done by means of bits DEMBOOSTA[1:0], which increases progressively the startup current level. The DC/DCA sensitivity to any overflow current can be modified (20%) by using the ICCADJA bit (SC1_CFG3 register). Initialization Procedure for DC/DC A converter The initialization procedure is described in flow chart: • Select the CVCC1 level by means of bits VCARD1[1:0] in SC1_CFG0 register, • Set bits DEMBOOSTA[1:0] in SC1_CFG4 register following the current level control wanted. • Monitor VCARD_OK1 bit in SC1_STATUS register in order to know when the DC/DC A Converter is ready (CVCC1 voltage has reached the expected level) While VCC1 remains higher than 3.6V and startup current lower than 30 mA (depending on the load type), the DC/DC A converter should be ready without having to increment DEMBOOSTA[1:0] bits beyond [0:0] level. If at least one of the two conditions are not met (VCC < 3.6V or startup current > 30 mA), it will be necessary to increment the DEMBOOSTA[1:0] bits until the DC/DC converter is ready. Increment of DEMBOOSTA[1:0] bits increases at the same time the current overflow level in the same proportion as the startup current. So once the DC/DC converter is ready it advised to decrement the DEMBOOSTA[1:0] bits to restore the overflow current to its normal or desired value. 20 AT83C26 7511B–SCR–10/05 AT83C26 Figure 9. DC/DC A Converter Initialization Procedure DEMBOOSTA[1:0]=[0:0] Set Time-out to 3 ms VCARD_OK1=1 Time-out Expired Decrement DEMBOOSTA[1:0] to adjust the current overflow END Increment DEMBOOSTA[1:0] DEMBOOSTA[1:0] is at Maximum? DC/DC A Converter Initialization Failure END DC/DC B converter The DC/DC B converter is controlled by DCDCB register. The DC/DC B converter can be switched on even if CPRES2 pin remains inactive. A write operation in VDCB[1:0] (0x01, 0x02, 0x03) starts the DC/DC. When the output voltage remains within the voltage range specified by VDCB_OK[1:0], the VDCB_OK bit is set. The DC/DC B Converter can work in two different modes which are selected by STEPREGB: • Pump Mode (STEPREGB = 0): an external inductance of 10 µH must be connected between pins LIB and VCC. VCC can be higher or lower than selected voltage. • Regulator mode (STEPREGB = 1): no external inductance is required but VCC must be always higher than selected voltage+0.3V. The current drawn from power supply by the DC/DC B converter is controlled during the startup phase in order to avoid high transient current mainly in Pump Mode which could cause the power supply voltage to drop dramatically. This control is done by means of bits DEMBOOSTB[1:0], which increases progressively the startup current level. 21 7511B–SCR–10/05 The DC/DCB sensitivity to any overflow current can be modified (20%) by using the ICCADJB bit (DC/DCB register). Initialization Procedure for DC/DC B converter The initialization procedure is described in flow chart: • Select the DC/DC B level by means of bits VDCB[1:0] in DCDCB register, • Set bits DEMBOOSTB[1:0] in INTERFACEB register following the current level control wanted. • Monitor VDCB_OK bit in DCDCB register in order to know when the DC/DC B Converter is ready Figure 10. DC/DC B Converter Initialization Procedure DEMBOOSTB[1:0]=[0:0] Set Time-out to 3 ms VDCB_OK=1 Time-out Expired Decrement DEMBOOSTB[1:0] to adjust the current overflow END (ready to start LDO) Increment DEMBOOSTB[1:0] DEMBOOSTB[1:0] is at Maximum? DC/DC B Converter Initialization Failure END Increment of DEMBOOSTB[1:0] bits increases at the same time the current overflow level in the same proportion as the startup current. So once the DC/DC B converter is ready it advised to decrement the DEMBOOSTB[1:0] bits to restore the overflow current to its normal or desired value. 22 AT83C26 7511B–SCR–10/05 AT83C26 LDO initialization Procedure When the DC/DC B voltage rises the selected voltage (VDCB_OK=1), the card voltage selection on CVCC2, CVCC3, CVCC4 or CVCC5 starts the corresponding LDO. The CVCC2 card voltage must be started in first (if needed). When the VCARD_OK2 is set, the CVCC3,CVCC4, CVCC5 card voltage are started one after each other (if needed) with the same procedure. The SC2_FULL bit must be set to use SC2 full interface: CIO3/CC42 is CC42 and CRST3/CC82 is CC82. As the power supply of CIO3/CC42 and of CRST3/CC82 is CVCC3, when SC2_FULL=1, CVCC3 = CVCC2. The SC3 interface is disable and LDO3 receives LDO2 command (VCARD3[1:0] = VCARD2[1:0]). Figure 11. LDOn Initialization Procedure (n = 2, 3, 4, 5) Init condition: DCDCB started (VDCB_OK = 1) Start LDOn, write VCARDn[1:0] Set Timer 2ms IPLUSn = 1 VCARD_OKn = 1 LDOn started Time-out Expired and IPLUSn=1 ? LDOn initialization failure The LDOn output voltage must be at 0V before to program 1.8V/3V/5V. 23 7511B–SCR–10/05 Activation Sequence Overview (n=1, 2, 3, 4, 5) The activation sequence on SC1 is only available if a card is detected on CPRES1 (CARDIN1 bit = 1). The activation sequence on SC2 is only available if a card is detected on CPRES2 (CARDIN2 bit = 1). The activation sequence on SC3, SC4, SC5, is only available if DC/DC B is started (VDCB_OK = 1). The SCn interface starts the activation sequence after a TWI write command in VCARDn[1:0] bits to program the CVCCn voltage. The SC3, SC4, SC5 interfaces (SIM/SAM interfaces) don’t have card presence detector. After the DC/DC start, the user application will check the ATR to detect if a SIM/SAM is present in the connector. The automatic reset transition mode (ART=1) controls the CRST pin and check if the first start bit of the ATR respects ISO7816 timings. All status bits of an interface (see bits in registers with ”This bit is cleared by hardware when this register is read”) must be cleared before to start an activation sequence. Software Activation for SCn interfaces (n=1, 2, 3, 4, 5) with ARTn bit = 0 The activation sequence is controlled by software using TWI commands, depending on the cards to support. For ISO 7816 cards, the following sequence can be applied: 1. Card Voltage is set by software to the required value (VCARDn[1:0] bits). The TWI writing command in VCARDn[1:0] starts the DC/DC (or LDO). 2. Wait of the end of the DC/DC (or LDO) init with a polling on VCARD_OKn bit or wait for INT to go Low. When VCARD_OKn bit is set (by hardware), CARDIOn bit should be set by software. 3. CKSTOPn, IODISn are programmed by software. CKSTOPn bit is reset to have the clock running. IODISn (see IO_SELECT for SC2, SC3, SC4, SC5) is reset to enable the transparent mode on CIOn,CC4n, CC8n. 4. CRSTn pin is controlled by software using CARDRSTn bit. 24 AT83C26 7511B–SCR–10/05 AT83C26 Figure 14. Software activation without automatic control (ARTn bit = 0) CVCCn CRSTn 4 1 3 CCLKn CIOn ATR 2 Note: – It is assumed that initially VCARDn[1:0], CARDCKn, CARDIOn and CARDRSTn bits are cleared, CKSTOPn and IODISn are set (those bits are further explained in the registers description) – The user should check the AT83C26 status and possibly resume the activation sequence if one TWI transfer is not acknowledged during the activation sequence. Software activation for SCn (n=1, 2, 3, 4, 5) interfaces and ARTn bit = 1 The following sequence can be applied: 1. Card Voltage is set by software to the required value (VCARDn1:0] bits in SCn_CFG0 register). This writing starts the DC/DC converter (or LDO). 2. Wait of the end of the DC/DC init (or LDO) with a polling on VCARD_OKn bit or wait for INT to go Low. When VCARD_OKn bit is set (by hardware), CARDIOn bit should be set by software. 3. CKSTOPn, IODISn are programmed by software. CKSTOPn bit is reset to have the clock running. IODISn is reset to enable the transparent mode on CIOn,CC4n, CC8n. 4. CARDRSTn bit is set by software. Automatic Reset Transition description: A 16-bit counter starts when CARDRSTn bit is set. It counts card clock cycles. The CRSTn signal is set when the counter reaches the TIMER_MSB and TIMER_LSB value which corresponds to the “tb” time (Figure 15).The counter is reseted when the CRSTn pin is released and it is stopped at the first start bit of the Answer To Request (ATR) on CIOn pin. The CIOn pin is not checked during the first 200 clock cycles (ta, Figure 15). If the ATR arrives before the counter reaches TIMER_MSB and TIMER_LSB values, the activation sequence fails, 25 7511B–SCR–10/05 the CRSTn signal is not set and the CAPTURE_MSB and CAPTURE_LSB registers contain the value of the counter at the arrival of the ATR. If the ATR arrives after the rising edge on CRSTn pin and before the card clock counter overflows (65535 clock cycles), the activation sequence completes. The CAPTURE_MSB and CAPTURE_LSB registers contain the value of the counter at the arrival of the ATR (tc time on Figure 15). Figure 15. Software activation with ARTn bit = 1 CARDRSTn bit set CVCCn 4 3 1 CRSTn CCLKn CIOn ta 2 tb tc ISO 7816 constraints: ta = 200 card clock cycles 400 card clock cycles< = tb 400 card clock cycles< = tc < = 40000 card clock cycles Timer[1-0] reset value is 400. Warm reset (n=1, 2, 3, 4, 5) The AT83C26 offers a simple and accurate way to control the CRSTn signal during a warm reset. After an activation sequence (cold reset), a warm reset is started with a low level on CRST during a define delay (between 40000 and 45000 clock cycles for example). The ARTn bit, the TIMER_MSB and the TIMER_LSB are used to control CRSTn. The first step is to load the number of CCLK cycles with CRSTn=0 in TIMER registers. The warm reset is started by setting ART bit (if ART bit is already set, reset ART before). 26 AT83C26 7511B–SCR–10/05 AT83C26 The CRST signal will be equal to 0 during the number of clock cycles programmed in TIMER_MSB and TIMER_LSB. Then, the CRST signal will be at 1. Figure 16. Warm reset with ARTn bit = 1 ART = 1 CVCCn CRSTn CCLKn CIOn t t = TIMER value Deactivation Sequence Overview The deactivation sequence should follows the order defined in ISO7816-3 specification. The AT83C26 has two deactivation modes: • Standard deactivation mode: This mode is used to stop exchange with smart card when the AT83C26 power supply is present. The DCCLK signal is used for deactivation sequence timings. • Emergency deactivation mode: This mode is used when the AT83C26 power supply is took off. Deactivation sequence on SCn interface (n=1, 2, 3, 4, 5) The card automatic deactivation is triggered when one the following condition occurs: • ICARDERR1 bit is set by hardware (SC1) • VCARDERRn bit is set by hardware (or by software) • INSERT1 is set and CARDIN1 is cleared (SC1) • INSERT2 is set and CARDIN2 is cleared (SC2) • SHUTDOWNA bit is set by software (SC1) • SHUTDOWNB bit is set by software (SC2, SC3, SC4, SC5) 27 7511B–SCR–10/05 • Reset pin going low (SC1, SC2, SC3, SC4, SC5) • Power Fail (VPFDP) It is a self-timed sequence which cannot be interrupted when started (see Figure 17). Each step is separated by a delay based on Td equal to 8 periods of DCCLK, typically 2 to 2.4 µs: 1. T0: CARDRSTn is cleared, SHUTDOWNA (for SC1) bit is set. 2. T0 + 5 x Td:CARDCKn is cleared, CKSTOPn, CARDIOn and IODIS are set. 3. T0 + 6 x Td: CARDIOn is cleared. 4. T0 + 7 x Td: VCARDn[1:0] = 00. Figure 17. Deactivation Sequence CVCC CRST CCLK CIO, CC4, CC8 5 x Td t1 Notes: Td Td t2 1. Setting ICARDERR1 by software does not trigger a deactivation on SC1. VCARDERRn can be used to deactivate the card by software. 2. If CCLKn=A2 or A2/2, deactivation follows fig13 with 2 timing modifications: t1=5.5*Td and t2=0.5*Td. 3. Td is based on DCCLK clock. Emergency deactivation sequence on SCn interface (n=1, 2, 3, 4, 5) The card emergency automatic deactivation is triggered when one the following condition occurs: • Software TWI Reset (SC1, SC2, SC3, SC4, SC5) • Power fail on VCC (SC1, SC2, SC3, SC4, SC5) If the power supply is disconnected, a standard deactivation is started when VCC = VPFDP. When VCC is equal to VPFDM, the emergency deactivation occurs and eventually ends the standard deactivation. 28 AT83C26 7511B–SCR–10/05 AT83C26 Figure 18. Power Fail Detection VCC start standard deactivation VPFDP VPFDM start emergency deactivation Figure 19. Emergency deactivation sequence CVCC CRST CCLK CIO, CC4, CC8 During an emergency deactivation, the signals fall according to the order described in Fig18. Transparent mode Full transparent mode on SCn interfaces (n=1, 2) If the micro controller outputs ISO 7816 signals, a transparent mode allows to connect, CCLK, CIO, CRST, CC4 and CC8 signals on outputs after an electrical level control. The AT83C26 level shifters adapt the card signals to the smart card voltage selection. The CCLK micro controller signal can be connected to the A2/CK pins (see CKSn[2:0]). CKSn[2:0] bits allow to select standard or transparent configuration for the CCLKn pin. A2/CK inputs always give the TWI address at reset. If A2/CK input is tied to the host micro controller and its reset value is unknown, a general call on the TWI bus allows to reset all the AT83C26 devices and set its address after A2/CK input is fixed. 29 7511B–SCR–10/05 Figure 20. Transparent Mode Description AT83C26 Micro controller CCLK A2/CK CCLKn CRST A1/RST CRSTn CIO I/O1 CIOn CC4 AUX1 CC4n CC8 AUX2 CC8n SMART CARD Full transparent mode on SCn interfaces (n= 3, 4, 5) The transparent mode with A2/CK is also available for SC3, SC4 and SC5 interfaces without CC4 and CC8. Figure 21. Transparent Mode Description AT83C26 Micro controller CCLK A2/CK CCLKn CRSTn CIO I/O2 SIM/SAM CIOn Interrupts The INT output is High by default. INT is driven Low by at least one of the following event: 30 – INSERT1 or INSERT2 bits set (card insertion/extraction or bit set by software) – VCARD_INTn (n=1,2,3,4,5) bits set (the DC/DC A or LDO2 to LDO5 output voltage has settled) – VDCB_INT bit set (the DC/DC B output voltage has settled) – over-current detection on CVCC1 – VCARDERRn bit set (out of range voltage on CVCCn or bit set by software) (n=1,2,3,4,5) – ATRERRn bit set (no ATR before the card clock counter overflows or bit set by software) (n=1,2,3,4,5) AT83C26 7511B–SCR–10/05 AT83C26 Several AT83C26 devices can share the same interrupt pin and the micro controller can identify the interrupt sources by polling the interrupt bits of the AT83C26 devices using TWI commands. A TWI read command of the interrupt bit corresponding to the IT clears the bit. When all IT bits are cleared, the INT output becomes high. The ITDIS register contains 4 bits to control SCn interrupts (n= 2,3,4,5). If ITDISn bit is set, the flags are set but the INT pin isn’t driven low if an interrupt event appears. Table 4. Interrupt bits description Bit name Register name Mask on INT pin Remark INSERT1 SC1_CFG0 INSERT2 SC2_CFG0 VCARD_INT1 SC1_STATUS VCARD_INT2 SC2_CFG0 ITDIS2 VCARD_OK2 is set VCARD_INT3 SC3_CFG0 ITDIS3 VCARD_OK3 is set VCARD_INT4 SC4_CFG0 ITDIS4 VCARD_OK4 is set VCARD_INT5 SC5_CFG0 ITDIS5 VCARD_OK5 is set VDCB_INT DCDCB VDCB_OK is set ICARDERR1 SC1_CFG0 Over current on DCDCA. VCARDERR1 SC1_CFG0 Ouput voltage out of range on DCDCA VCARDERR2 SC2_CFG0 ITDIS2 Ouput voltage out of range on LDO2 VCARDERR3 SC3_CFG0 ITDIS3 Ouput voltage out of range on LDO3. VCARDERR4 SC4_CFG0 ITDIS4 Ouput voltage out of range on LDO4 VCARDERR5 SC5_CFG0 ITDIS5 Ouput voltage out of range on LDO5 ATRERR1 SC1_CFG0 ATRERR2 SC2_CFG0 ITDIS2 Error on SC2 for ATR reception in automatic mode ATRERR3 SC3_CFG0 ITDIS3 Error on SC3 for ATR reception in automatic mode ATRERR4 SC4_CFG0 ITDIS4 Error on SC4 for ATR reception in automatic mode ATRERR5 SC5_CFG0 ITDIS5 Error on SC5 for ATR reception in automatic mode Smart card inserted/extracted in SC1 ITDIS2 Smart card inserted/extracted in SC2 VCARD_OK1 is set Error on SC1 for ATR reception in automatic mode 31 7511B–SCR–10/05 After the reading and the clear of the interrupt bits, several bits are used to control the status. Table 5. Status bits description Bit name Register name Remark CARDIN1 SC1_STATUS Smart card presence in SC1 CARDIN2 SC1_STATUS Smart card presence in SC2 VCARD_OK1 SC1_STATUS CVCC1 voltage in range programmed in VCARD1[1:0] VCARD_OK2 SC2_CFG0 CVCC2 voltage in range programmed in VCARD2[1:0] VCARD_OK3 SC3_CFG0 CVCC3 voltage in range programmed in VCARD3[1:0] VCARD_OK4 SC4_CFG0 CVCC4 voltage in range programmed in VCARD4[1:0] VCARD_OK5 SC5_CFG0 CVCC5 voltage in range programmed in VCARD5[1:0] VDCB_OK DCDCB CVCCB voltage in range programmed in VDCB[1:0] The status for the ICARDERR1 and VCARDERRn (n= 1 to 5) bits is controlled with VCARD_OKn bits. The status for the ATRERRn (n= 1 to 5) is controlled by reading of values in CAPTURE_MSB and CAPTURE_LSB. Slew rate control The AT83C26 proposed a slew rate control on CIOn and CCLKn pins (n=1, 2, 3, 4, 5). The control operates on rising and falling edges of CCLKn and only on rising edge of CIOn. Four modes are available: • Automatic mode: The slew rate depends on VCARDn[1:0] value. The slew rate value is optimized according to CVCCn. • Mode 1, 2 , 3 (1.8V, 3V, 5V): The user can forced the slew rate if needed. For example if CVCCn = 5V, the user can program 1.8V or 3V to speed up the slew rate in case of long wire connection between AT83C26 and smart cards. Power down mode SHUTDOWNA bit and SHUTDOWNB bit must be set to activate power down mode on DCDCA and DCDCB converters. If SHUTDOWNA = SHUTDOWNB = 1, the AT83C26 internal regulator also enters in power down mode. The consumption is then about 30µA. To exit from power down mode, TWI commands are needed to clear SHUTDOWNA and SHUTDOWNB. 32 AT83C26 7511B–SCR–10/05 AT83C26 Write Commands The write commands are: 1. General Call Reset: A general call followed by the value 06h has the same effect as a Reset command. 2. Reset: Initialize all the logic and the TWI interface as after a power-up or power-fail reset. If the interface is activated, an emergency de-activation sequence is also performed. This is a one-byte command. 3. Write SC1_CFG0, SC1_CFG1, SC1_CFG2, SC1_CFG3, SC1_CFG4: Configure the device according to the last six bits in the SC1_CFG0 register and to the following four bytes in SC1_CFG1, SC1_CFG2, SC1_CFG3 then SC1_CFG4 registers. This is a five bytes command. Figure 22. Command byte format for Write SC1_CFG0 command b7 b6 b5 b4 b3 b2 b1 b0 1 0 X X X X X X SC1_CFG0 on 6 Bits 4. Write TIMER_MSB, TIMER_LSB: Program the 16-bit automatic reset transition timer with the following two bytes. This is a three bytes command. 5. Write SC1_INTERFACE: Program the interface byte. This is a one-byte command. The MSB of the command byte is fixed at 0. 6. Write common config smart cards: IO_SELECT, INTERFACE_B, ITDIS: Configuration of parameters for smart card interfaces. 7. Write SC2 interface: SC2_CFG0, SC2_CFG1, SC2_CFG2 Configuration of smart card interface 2. 8. Write SC3 interface: SC3_CFG0, SC3_CFG2 Configuration of SIM/SAM interface 3. 9. Write SC4 interface: SC4_CFG0, SC4_CFG2 Configuration of SIM/SAM interface 4. 33 7511B–SCR–10/05 10. Write SC5 interface: SC5_CFG0, SC5_CFG2 Configuration of SIM/SAM interface 5. 11. Write DCDCB config: DCDCB, LDO Configuration of DCDCB converter. 12. Write SLEW_CTRL config: SLEW_CTRL_1, SLEW_CTRL_2, SLEW_CTRL_3 Configuration of slew rate for CCLKn and CIOn (n = 1, 2, 3, 4, 5). Table 6. Write Commands Description Address Byte (See Table 2) Command Byte [0] Data Byte 1 Data Byte 2 [1] Data Byte 3 [2] [3] 1. General Call Reset 0000 0000 0000 0110 2. Reset 0100 XX10 1111 1111 3. Write config 0100 XX10 (10 + SC1_CFG0 6 bits) SC1_CFG1 SC1_CFG2 4. Write Timer 0100 XX10 1111 1100 TIMER_MSB TIMER_LSB 5. Write Interface 0100 XX10 (0+SC1_INTERFACE 7 bits) 6.Write Config SC on DCDCB 0100 XX10 1111 1000 IO_SELECT INTERFACE_B ITDIS 7. Write SC2 interface 0100 XX10 1111 1001 SC2_CFG0 SC2_CFG1 SC2_CFG2 8. Write SC3 interface 0100 XX10 1111 1010 SC3_CFG0 SC3_CFG2 9. Write SC4 interface 0100 XX10 1111 1011 SC4_CFG0 SC4_CFG2 10. Write SC5 interface 0100 XX10 1111 1101 SC5_CFG0 SC5_CFG2 11. Write DCDCB config 0100 XX10 1111 1110 DCDCB LDO 12. Write SLEW_CTRL config 0100 XX10 1111 0111 SLEW_CTRL_1 SLEW_CTRL_2 34 Data Byte 4 [4] SC1_CFG3 SC1_CFG4 SLEW_CTRL_3 AT83C26 7511B–SCR–10/05 AT83C26 Read Command After a write command, even with a length of 0 byte, the next read operation is performed on the corresponding byte. The write command sets the “read pointer”. After the reset, the “read pointer” is on SC1 registers FFh is completing the transfer if the micro controller attempts to read beyond the last byte. Flags are only reseted after the corresponding byte read has been acknowledged by the master. Figure 23. Read command byte b7 b6 b5 b4 b3 b2 b1 b0 0 1 0 0 X X 1 1 A2 A1 levels on reset Table 7. Read Commands Description 1. After reset or 2. After write command write 5. After 6. After 7. After 8. After write command write command write command write number 6 write write command command number 7 number 8 number 2, 3, 4 command number 9 number 10 number 11 number 12 3. After 4. After command [0] SC1_STATUS STATUSB SC2_CFG0 SC3_CFG0 SC4_CFG0 SC5_CFG0 DCDCB SLEW_CTRL_1 [1] SC1_CFG0 IO_SELECT SC2_CFG1 SC3_CFG2 SC4_CFG2 SC5_CFG2 LDO SLEW_CTRL_2 [2] SC1_CFG1 INTERFACE_B SC2_CFG2 0xFF 0xFF 0xFF 0xFF SLEW_CTRL_3 [3] SC1_CFG2 ITDIS 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF [4] SC1_CFG3 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF [5] SC1_CFG4 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF [6] SC1_INTERFACE 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF [7] TIMER_MSB 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF [8] TIMER_LSB 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF [9] CAPTURE_MSB 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF [10] CAPTURE_LSB 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF [11] 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 35 7511B–SCR–10/05 Registers summary The table below gives a quick view on AT83C26 registers. Table 8. Smart card 1 interface registers 7 6 5 4 3 2 1 0 SC1_CFG0 1 0 ATRERR1 INSERT1 ICARDERR1 VCARDERR1 VCARD11 VCARD10 SC1_CFG1 X ART1 SHUTDOWNA CARDDET1 PULLUP1 CDS12 CDS11 CDS10 SC1_CFG2 0 DCK2 DCK1 DCK0 X CKS12 CKS11 CKS10 SC1_CFG3 X X X ICCADJA X X X X SC1_CFG4 X DEMBOOSTA1 DEMBOOSTA0 STEPREGA INT_PULLUP X X CRST_SEL1 SC1_INTERFACE 0 IODIS1 CKSTOP1 CARDRST1 CARDC81 CARDC41 CARDCK1 CARDIO1 CC81 CC41 CARDIN1 VCARD_OK1 X VCARD_INT1 CRST1 CIO1 SC1_STATUS Table 9. Smart card 2 interface registers 7 6 5 4 3 2 1 0 SC2_CFG0 VCARD_INT2 VCARD_OK2 ATRERR2 INSERT2 X VCARDERR2 VCARD21 VCARD20 SC2_CFG1 X X SC2_FULL CARDDET2 PULLUP2 CDS22 CDS21 CDS20 SC2_CFG2 ART2 CRST_SEL2 CARDRST2 CARDCK2 CKSTOP2 CKS22 CKS21 CKS20 Table 10. SIM/SAM 3 interface registers 7 6 5 4 3 2 1 0 SC3_CFG0 VCARD_INT3 VCARD_OK3 ATRERR3 X X VCARDERR3 VCARD31 VCARD30 SC3_CFG2 ART3 X CARDRST3 CARDCK3 CKSTOP3 CK32 CKS31 CKS30 Table 11. SIM/SAM 4 interface registers 7 6 5 4 3 2 1 0 SC4_CFG0 VCARD_INT4 VCARD_OK4 ATRERR4 X X VCARDERR4 VCARD41 VCARD40 SC4_CFG2 ART4 X CARDRST4 CARDCK4 CKSTOP4 CKS42 CKS41 CKS40 Table 12. SIM/SAM 5 interface registers 7 6 5 4 3 2 1 0 SC5_CFG0 VCARD_INT5 VCARD_OK5 ATRERR5 X X VCARDERR5 VCARD51 VCARD50 SC5_CFG2 ART5 X CARDRST5 CARDCK5 CKSTOP5 CKS52 CKS51 CKS50 36 AT83C26 7511B–SCR–10/05 AT83C26 Table 13. Common registers for SC1/SC2/SC3/SC4/SC5 7 6 5 4 3 2 1 0 TIMER_MSB Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 TIMER_LSB Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 CAPTURE_MSB Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 CAPTURE_LSB Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 X X X X IOSEL3 IOSEL2 IOSEL1 IOSEL0 IO_SELECT Table 14. Common registers for SC2/SC3/SC4/SC5 7 6 5 4 3 2 1 0 INTERFACEB X CARDC82 CARDIO5 CARDIO4 CARDIO3/ CARDC42 CARDIO2 DEMBOOSTB1 DEMBOOSTB0 STATUSB X CARDIN2 CIO5 CIO4 CRST3/ CC82 CIO3/ CC42 CRST2 CIO2 IODIS5 IODIS4 IODIS3 IODIS2 ITDIS5 ITDIS4 ITDIS3 ITDIS2 ITDIS Table 15. DC/DC B registers DCDCB LDO 7 6 5 4 3 2 1 0 SHUTDOWNB VDCB_INT VDCB_OK 0 ICCADJB STEPREGB VDCB1 VDCB0 IPLUS5 IPLUS4 IPLUS3 IPLUS2 X X X X Table 16. Slew control registers for CIO and CCLK pins 7 6 5 4 3 2 1 0 SLEW_CTRL_1 CCLK2_SLEW_CTR L1 CCLK2_SLEW_CT RL0 CIO2_SLEW_CT RL1 CIO2_SLEW_CT RL0 CCLK1_SLEW_CT RL1 CCLK1_SLEW_CT RL0 CIO1_SLEW_CT RL1 CIO1_SLEW_CTR L0 SLEW_CTRL_2 CCLK4_SLEW_CTR L1 CCLK4_SLEW_CT RL0 CIO4_SLEW_CT RL1 CIO4_SLEW_CT RL0 CCLK3_SLEW_CT RL1 CCLK3_SLEW_CT RL0 CIO3_SLEW_CT RL1 CIO3_SLEW_CTR L0 SLEW_CTRL_3 X X X X CCLK5_SLEW_CT RL1 CCLK5_SLEW_CT RL0 CIO5_SLEW_CT RL1 CIO5_SLEW_CTR L0 37 7511B–SCR–10/05 Registers Table 17. SC1_ CFG0(Config Byte 0 for SC1) 7 6 5 4 3 2 1 0 1 0 ATRERR1 INSERT1 ICARDERR1 VCARDERR1 VCARD11 VCARD10 Bit Number Bit Mnemonic 7-6 1-0 Description These bits cannot be programmed and are read as 1-0. Answer to Reset Interrupt for SC1 5 ATRERR1 This bit is set when the card clock counter overflows (no falling edge on CIO1 is received before the overflow of the card clock counter). This bit is cleared by hardware when this register is read. It can be set by software for test purpose. 4 INSERT1 Card Insertion Interrupt This bit is set when a card is inserted or extracted: a change in CARDIN value filtered according to CDS[2-0]. It can be set by software for test purpose. This bit is cleared by hardware when this register is read. It cannot be cleared by software. 3 ICARDERR1 Card Over Current Interrupt This bit is set when an over current is detected on CVCC. It can be set by software for test purpose (no card deactivation is performed). This bit is cleared by hardware when this register is read. It cannot be cleared by software. 2 VCARDERR1 Card Out of Range Voltage Interrupt This bit is set when the output voltage goes out of the voltage range specified by VCARD field. It can be set by software for test purpose and deactivate the card. This bit is cleared by hardware when this register is read. It cannot be cleared by software. Card Voltage Selection VCARD1[1:0] = 00: 0V VCARD1[1:0] = 01: 1.8V VCARD1[1:0] = 10: 3V 1-0 VCARD1[1:0] VCARD1[1:0] = 11: 5V VCARD1[1:0] writing to 1.8V, 3V, 5V starts the DC/DC if a card is detected. VCARD1[1:0] writing to 0 stops the DC/DC. No card deactivation is performed when the voltage is changed between 1.8V, 3V or 5V. The micro controller should deactivate the card before changing the voltage. Reset value = 0x 1000 0000 38 AT83C26 7511B–SCR–10/05 AT83C26 SC1_CFG Table 18. SC1_CFG1 (Config Byte 1 for SC1 7 6 5 4 3 2 1 0 X ART1 SHUTDOWNA CARDDET1 PULLUP1 CDS12 CDS11 CDS10 Bit Number Bit Mnemonic 7 X 6 ART1 Description Automatic Reset Transition Set this bit to have the CRST1 pin changed according to activation sequence. Clear this bit to have the CRST1 pin immediately following the value programmed in CARDRST1. Shutdown DC/DCA 5 SHUTDOWNA Set this bit to reduce the power consumption. An automatic de-activation sequence will be done. VCARD[1:0] bits are reset. Clear this bit to enable VCARD1[1:0] selection. Card Presence Detection Polarity 4 CARDDET1 Set this bit to indicate the card presence detector is closed when no card is inserted (CPRES is low). Clear this bit to indicate the card presence detector is open when no card is inserted (CPRES is high). Pull-up Enable 3 PULLUP1 Set this bit to enable the internal pull-up on the CPRES pin. This allows to minimize the number of external components. Clear this bit to disable the internal pull-up and minimize the power consumption when the card detection contact is on. Then an external pull-up must be connected to VCC (typically a 1 MΩ resistor). Card Detection filtering CPRES1 is sampled by the master clock provided on CLK input. A change on CPRES1 is detected after: CDS1[2-0] = 0: no sample(1) CDS1[2-0] = 1: 4 identical samples CDS1[2-0] = 2: 8 identical samples (reset value) CDS1[2-0] = 3: 16 identical samples 2-0 CDS1[2:0] CDS1[2-0] = 4: 32 identical samples CDS1[2-0] = 5: 64 identical samples CDS1[2-0] = 6: 128 identical samples CDS1[2-0] = 7: 256 identical samples Note: 1. When CDS[2-0] = 0, a card insertion (even if CLK is stopped) puts a low level on INT pin. This can be used to wake up the external micro controller and restart CLK when a card is inserted in the AT83C24. Reset value = 0x X000 1010 39 7511B–SCR–10/05 Table 19. SC1_CFG2 (Config Byte 2 for SC1) 7 6 5 4 3 2 1 0 0 DCK2 DCK1 DCK0 X CKS12 CKS11 CKS10 Bit Number Bit Mnemonic 7 0 Description This bit must be always at 0. DCK is the first level of prescaler factor. CLK signal is divided by the prescaler value and outputs DCCLK signal. DCCLK is an input for CCLK prescaler. DCK[2:0] = 0: prescaler factor equals 1 DCK[2:0] = 1: prescaler factor equals 2 DCK[2:0] = 2: prescaler factor equals 4 6-4 DCK[2:0] DCK[2:0] = 3: prescaler factor equals 6 DCK[2:0] = 4: prescaler factor equals 8 DCK[2:0] = 5: prescaler factor equals 10 DCK[2:0] = 6: prescaler factor equals 12 DCK[2:0] = 7: Reserved DCCLK is used for pad management and dectivation sequence. 3 X Card Clock prescaler factor for CCLK1. CKS1 [2:0] = 0: CCLK1 = CLK (the maximum frequency on CLK is 24 MHz) CKS1 [2:0] = 1: CCLK1 = DCCLK CKS1[2:0] = 2: CCLK1 = DCCLK / 2 2-0 CKS1[2:0] CKS1[2:0] = 3: CCLK1 = DCCLK / 4 CKS 1[2:0] = 4: CCLK1 = A2 CKS1 [2:0] = 5: CCLK1 = A2 / 2 CKS1[2:0] = 6: CCLK1 = CLK / 2 CKS1 [2:0] = 7: CCLK1 = CLK / 4 Reset value = 0x 0001 X000 Notes: 40 1. When CKS1 value is changed a special logic insures no glitch occurs on the CCLK1 pin and actual configuration changes can be delayed by half a period to two periods of CCLK1. 2. CCLK1 must be stopped with CKSTOP1 bit before switching from CKS1 = (0, 1, 2, 3, 6, 7) to CKS1 = (4, 5) or vice versa. AT83C26 7511B–SCR–10/05 AT83C26 Table 20. SC1_CFG3 (Config Byte 3 for SC1) 7 6 5 4 3 2 1 0 X X X ICCADJA X X X X Bit Number Bit Mnemonic 7-5 X Description CICC overflow adjust This bit controls the DC/DCA sensitivity to any overflow current. 4 ICCADJA Set this bit to decrease the DC/DCA sensitivity (CICC_ovf is increased by about 20%). Clear this bit to have a normal configuration. The reset value is 0. 3 X 2 X 1 X 0 X Reset value = 0x XXX0 XXXX 41 7511B–SCR–10/05 Table 21. SC1_CFG4 (Config Byte 4 for SC1) 7 6 5 4 3 2 1 0 X DEMBOOSTA1 DEMBOOSTA0 STEPREGA INT_PULLUP X X CRST_SEL1 Bit Number Bit Mnemonic 7 X Description DC/DC A Maximum Startup Current drawn from power supply 00: Normal: 80 mA average 6-5 DEMBOOSTA[1-0] 01: Normal + 18% 10: Normal + 18% (and boost on oscillator) 11: Normal + 40% 4 STEPREGA Step Regulator mode Clear this bit to enable the automatic step-up converter (CVCC is stable even if VCC is not higher than CVCC). Set this bit to permanently disable the step-up converter (CVCC is stable only if VCC is sufficiently higher than CVCC). This bit must always be set if no external self is used Internal pull-up 3 INT_PULLUP Set this bit to activate the internal pull-up (connected internally to VCC) on INT pin. Clear this bit to deactivate the internal pull-up. 2 X 1 X Card Reset Selection 0 CRST_SEL1 Set this bit to have the CRST1 pin driven by hardware through the A1/RST pin. Clear this bit to have the CRST1 pin driven by software through the CARDRST bit. The reset value is 0. Reset value = 0x X000 0000 42 AT83C26 7511B–SCR–10/05 AT83C26 _ Table 22. SC1_INTERFACE (Interface Byte for SC1) 7 6 5 4 3 2 1 0 0 IODIS1 CKSTOP1 CARDRST1 CARDC81 CARDC41 CARDCK1 CARDIO1 Bit Number 7 Bit Mnemonic 0 Description This bit should not be set. Card I/O isolation 6 IODIS1 Set this bit to drive the CIO1, CC41, CC81 pins according to CARDIO1, CARDC41, CARDC81 respectively. Clear this bit to drive the CIO1, CC41 and CC81 pins connected to inputs according to IOSEL[3/0] bits. CARD Clock Stop 5 CKSTOP1 Set this bit to stop CCLK1 according to CARDCK1. This can be used to set asynchronous cards in powerdown mode (GSM) or to drive CCLK1 by software. Clear this bit to have CCLK1 running according to CKS1. This can be used to activate asynchronous cards. Note: 4 CARDRST1 When this bit is changed a special logic ensures that no glitch occurs on the CCLK1 pin and actual configuration changes can be delayed by half a period to two periods of CCLK1. Card Reset Set this bit to enter a reset sequence according to ART1 bit value. Clear this bit to drive a low level on the CRST1 pin. Card C8 3 CARDC81 Set this bit to drive the CC81 pin High with the on-chip pull-up (according to IODIS1 bit value). The pin can then be an input (read in SC1_STATUS register). Clear this bit to drive a low level on the CC81 pin (according to IODIS1 bit value). Card C4 2 CARDC41 Set this bit to drive the CC41 pin High with the on-chip pull-up (according to IODIS1 bit value). The pin can then be an input (read in SC1_STATUS register). Clear this bit to drive a low level on the CC41 pin (according to IODIS1 bit value). Card Clock 1 CARDCK1 Set this bit to set a high level on the CCLK1 pin (according to CKSTOP1 bit value). Clear this bit to drive a low level on the CCLK1 pin. Card I/O 0 CARDIO1 Set this bit to drive the CIO1 pin High with the on-chip pull-up (according to IODIS1 bit value). The pin can then be an input (read in SC1_STATUS register). Clear this bit to drive a low level on the CIO1 pin (according to IODIS1 bit value). Reset value = 0x 0110 0000 43 7511B–SCR–10/05 Table 23. SC1_STATUS (Status Byte for SC1) 7 6 5 4 3 2 1 0 CC81 CC41 CARDIN1 VCARD_OK1 X VCARD_INT1 CRST1 CIO1 Bit Number Bit Mnemonic 7 CC81 Card CC8 This bit provides the actual level on the CC8 pin when read. 6 CC41 Card CC4 This bit provides the actual level on the CC4 pin when read. 5 CARDIN1 4 VCARD_OK1 3 X 2 VCARD_INT1 Description Card Presence Status This bit is set when a card is detected. It is cleared otherwise. SC1 Voltage Status This bit is set by the DCDCA when the output voltage remains within the voltage range specified by VCARD1[1:0] bits. It is cleared otherwise. SC1 Smart Card voltage interrupt This bit is set when VCARD_OK1 bit is set. This bit is cleared when read by the micro controller. 1 CRST1 0 CIO1 Card RST This bit provides the actual level on the CRST pin when read. Card I/O This bit provides the actual level on the CIO pin when read. Reset value = reset value depends on hardware configuration 44 AT83C26 7511B–SCR–10/05 AT83C26 Table 24. SC2_CFG0 () 7 6 5 4 3 2 1 0 VCARD_INT 2 VCARD_OK 2 ATRERR2 INSERT2 X VCARDERR2 VCARD21 VCARD20 Bit Number Bit Mnemonic 7 VCARD_INT2 Description SC2 voltage interrupt This bit is set when VCARD_OK2 bit is set. This bit is cleared when read by the micro controller. 6 VCARD_OK2 SC2 Voltage Status This bit is set by the LD02 when the output voltage remains within the voltage range specified by VCARD2[1:0] bits. It is cleared otherwise. Answer to Reset Interrupt for SC2 5 ATRERR2 This bit is set when the card clock counter overflows (no falling edge on CIO2 is received before the overflow of the card clock counter). This bit is cleared by hardware when this register is read. It can be set by software for test purpose. 4 INSERT2 Card Insertion Interrupt This bit is set when a card is inserted or extracted in SC2 connector: a change in CARDIN2 value filtered according to CDS2[2-0]. It can be set by software for test purpose. This bit is cleared by hardware when this register is read. It cannot be cleared by software. 3 2 X VCARDERR2 Interface 2 Card Out of Range Voltage Interrupt This bit is set when the output voltage on CVCCN goes out of the voltage range specified by VCRDN field. It can be set by software for test purpose and deactivate the card. This bit is cleared by hardware when this register is read. It cannot be cleared by software. The reset value is 0. Interface 2 Card Voltage Selection VCRD2[1:0] = 00: 0V VCRD2[1:0] = 01: 1.8V class C 1-0 VCARD2[1:0] VCRD2[1:0] = 10: 3V class B VCRD2[1:0] = 11: 5V class A No card deactivation is performed when the voltage is changed. The micro controller should deactivate the card before changing the voltage and activating the card again. The reset value is 00. Reset value = 0x 0000 X000 45 7511B–SCR–10/05 Table 25. SC2_CFG1 () 7 6 5 4 3 2 1 0 X X SC2_FULL CARDDET2 PULLUP2 CDS22 CDS21 CDS20 Bit Number Bit Mnemonic 7-6 X Description Set this bit to activate full IO interface on Smart card 2: • 5 SC2_FULL CIO3/CC42 is CC42 and CRST3/CC82 is CC82. • Interface 3 LDO is disabled. • CARDCK3 is reset and CKSTOP3 to stop CCLK on SC3. • ITDIS3 is set to disable interrupts from SC3. CVCC2 and CVCC3 shall be connected externally and SC2_FULL must be set before activating the LDO. Clear this bit only to use only CIO on interface 2: • CIO3/CC42 is CIO3 and CRST3/CC82 is CRST3. • Interface 3 can then be used independently to connect a SIM/SAM card. The reset value is 1. Card Presence Detection Polarity - Interface 2 4 CARDDET2 Set this bit to indicate the card presence detector is closed when no card is inserted (CPRES2 is low). Clear this bit to indicate the card presence detector is open when no card is inserted (CPRES2 is high). The reset value is 0. Pull-up Enable 3 Set this bit to enable the internal pull-up on the CPRES2 pin. This allows to minimize the number of external components. PULLUP2 Clear this bit to disable the internal pull-up and minimize the power consumption when the card detection contact is on. Then an external pull-up must be connected to VCC (typically a 1 MΩ resistor). The reset value is 1. Card Detection filtering - Interface 2 CPRES2 is sampled by the master clock provided on CLK input. A change on CPRES2 is detected after: CDS2[2-0] = 0: no sample(1) CDS2[2-0] = 1: 4 identical samples CDS2 [2-0] = 2: 8 identical samples (reset value) CDS2[2-0] = 3: 16 identical samples 2-0 CDS2[2:0] CDS2[2-0] = 4: 32 identical samples CDS2[2-0] = 5: 64 identical samples CDS2[2-0] = 6: 128 identical samples CDS2[2-0] = 7: 256 identical samples Note: 1. When CDS2[2-0] = 0 and ITDIS2 = 0, a card insertion (even if CLK is stopped) puts a low level on INT pin. This can be used to wake up the external micro controller and restart CLK when a card is inserted in the AT83C24. Reset value = 0x XX10 1010 46 AT83C26 7511B–SCR–10/05 AT83C26 Table 26. SC2_CFG2 () 7 6 5 4 3 2 1 0 ART2 CRST_SEL2 CARDRST2 CARDCK2 CKSTOP2 CKS22 CKS21 CKS20 Bit Number Bit Mnemonic 7 ART2 Description Automatic Reset Transition Set this bit to have the CRST2 pin changed according to activation sequence. Clear this bit to have the CRST2 pin immediately following the value programmed in CARDRST2. Card Reset Selection 6 CRST_SEL2 Set this bit to have the CRST2 pin driven by hardware through the A1/RST pin. Clear this bit to have the CRST pin driven by software through the CARDRST bit. The reset value is 0. 5 CARDRST2 Card Reset Set this bit to enter a reset sequence according to ART2 bit value. Clear this bit to drive a low level on the CRST2 pin. Card Clock 4 CARDCK2 Set this bit to set a high level on the CCLK2 pin (according to CKSTOP2 bit value). Clear this bit to drive a low level on the CCLK2 pin. CARD Clock Stop 3 CKSTOP2 Set this bit to stop CCLK2 according to CARDCK2. This can be used to set asynchronous cards in powerdown mode (GSM) or to drive CCLK2 by software. Clear this bit to have CCLK2 running according to CKS2. This can be used to activate asynchronous cards. Note: When this bit is changed a special logic ensures that no glitch occurs on the CCLK2 pin and actual configuration changes can be delayed by half a period to two periods of CCLK2. Interface 2 Card Clock Selection CKS2 [2:0] = 0: CCLK2 = CLK (then the maximum frequency is 24 MHz) CKS2 [3:0] = 1: CCLK2 = DCCLK CKS2 [3:0] = 2: CCLK2 = DCCLK / 2 2-0 CKS2[2:0] CKS2 [3:0] = 3: CCLK2 = DCCLK / 4 CKS2 [3:0] = 4: CCLK2 = A2 CKS2 [3:0] = 5: CCLK2 = A2 / 2 CKS2 [3:0] = 6: CCLK2 = CLK / 2 CKS2 [3:0] = 7: CCLK2 = CLK / 4 Reset value = 0x00001000 Notes: 1. When CKS2 value is changed a special logic insures no glitch occurs on the CCLK2 pin and actual configuration changes can be delayed by half a period to two periods of CCLK2. 2. CCLK2 must be stopped with CKSTOP2 bit before switching from CKS2 = (0, 1, 2, 3, 6, 7) to CKS2 = (4, 5) or vice versa. 47 7511B–SCR–10/05 Table 27. SC3_CFG0() 7 6 5 4 3 2 1 0 VCARD_INT3 VCARD_OK3 ATRERR3 X X VCARDERR3 VCARD31 VCARD30 Bit Number Bit Mnemonic 7 VCARD_INT3 Description SC3 voltage interrupt This bit is set when VCARD_OK3 bit is set. This bit is cleared when read by the micro controller. 6 VCARD_OK3 SC3 Voltage Status This bit is set by the LDO3 when the output voltage remains within the voltage range specified by VCARD3[1:0] bits. It is cleared otherwise. Answer to Reset Interrupt for SC3 5 ATRERR3 This bit is set when the card clock counter overflows (no falling edge on CIO3 is received before the overflow of the card clock counter). This bit is cleared by hardware when this register is read. It can be set by software for test purpose. 4 X 3 X 2 VCARDERR3 Interface 3 Card Out of Range Voltage Interrupt This bit is set when the output voltage on CVCCN goes out of the voltage range specified by VCRDN field. It can be set by software for test purpose and deactivate the card. This bit is cleared by hardware when this register is read. It cannot be cleared by software. The reset value is 0. Interface 3 Card Voltage Selection VCRD3[1:0] = 00: 0V VCRD3[1:0] = 01: 1.8V class C 1-0 VCARD3[1:0] VCRD3[1:0] = 10: 3V class B VCRD3[1:0] = 11: 5V class A No card deactivation is performed when the voltage is changed. The micro controller should deactivate the card before changing the voltage and activating the card again. The reset value is 00. Reset value = 0x 000X 0000 48 AT83C26 7511B–SCR–10/05 AT83C26 Table 28. SC3_CFG2 () 7 6 5 4 3 2 1 0 ART3 X CARDRST3 CARDCK3 CKSTOP3 CK32 CKS31 CKS30 Bit Number Bit Mnemonic 7 ART3 Description Automatic Reset Transition Set this bit to have the CRST3 pin changed according to activation sequence. Clear this bit to have the CRST3 pin immediately following the value programmed in CARDRST3. 6 5 X CARDRST3 Card Reset Set this bit to enter a reset sequence according to ART3 bit value. Clear this bit to drive a low level on the CRST3 pin. This bit must be cleared to use AUX2 pin for CRST3 source. Card Clock 4 CARDCK3 Set this bit to set a high level on the CCLK3 pin (according to CKSTOP3 bit value). Clear this bit to drive a low level on the CCLK3 pin. CARD Clock Stop 3 CKSTOP3 Set this bit to stop CCLK3 according to CARDCK3. This can be used to set asynchronous cards in powerdown mode (GSM) or to drive CCLK3 by software. Clear this bit to have CCLK3 running according to CKS3. This can be used to activate asynchronous cards. Note: When this bit is changed a special logic ensures that no glitch occurs on the CCLK3 pin and actual configuration changes can be delayed by half a period to two periods of CCLK3. Interface 4Card Clock Selection CKS3 [2:0] = 0: CCLK3 = CLK (then the maximum frequency is 24 MHz) CKS3 [3:0] = 1: CCLK3 = DCCLK CKS3 [3:0] = 2: CCLK3 = DCCLK / 2 2-0 CKS3[2:0] CKS3 [3:0] = 3: CCLK3 = DCCLK / 4 CKS3 [3:0] = 4: CCLK3 = A2 CKS3 [3:0] = 5: CCLK3 = A2 / 2 CKS3 [3:0] = 6: CCLK3 = CLK / 2 CKS3 [3:0] = 7: CCLK3 = CLK / 4 The reset value is 0. Reset value = 0x 0X00 1000 Notes: 1. When CKS3 value is changed a special logic insures no glitch occurs on the CCLK3 pin and actual configuration changes can be delayed by half a period to two periods of CCLK3. 2. CCLK3 must be stopped with CKSTOP3 bit before switching from CKS3 = (0, 1, 2, 3, 6, 7) to CKS3 = (4, 5) or vice versa. 49 7511B–SCR–10/05 Table 29. SC4_CFG0() 7 6 5 4 3 2 1 0 VCARD_INT4 VCARD_OK4 ATRERR4 X X VCARDERR4 VCARD41 VCARD40 Bit Number Bit Mnemonic 7 VCARD_INT4 Description SC4 voltage interrupt This bit is set when VCARD_OK4 bit is set. This bit is cleared when read by the micro controller. 6 VCARD_OK4 SC4 Voltage Status This bit is set by the LD04 when the output voltage remains within the voltage range specified by VCARD4[1:0] bits. It is cleared otherwise. Answer to Reset Interrupt for SC4 5 ATRERR4 This bit is set when the card clock counter overflows (no falling edge on CIO4 is received before the overflow of the card clock counter). This bit is cleared by hardware when this register is read. It can be set by software for test purpose. 4 X 3 X 2 VCARDERR4 Interface 4 Card Out of Range Voltage Interrupt This bit is set when the output voltage on CVCCN goes out of the voltage range specified by VCRDN field. It can be set by software for test purpose and deactivate the card. This bit is cleared by hardware when this register is read. It cannot be cleared by software. The reset value is 0. Interface 4 Card Voltage Selection VCRD4[1:0] = 00: 0V VCRD4[1:0] = 01: 1.8V class C 1-0 VCARD4[1:0] VCRD4[1:0] = 10: 3V class B VCRD4[1:0] = 11: 5V class A No card deactivation is performed when the voltage is changed. The micro controller should deactivate the card before changing the voltage and activating the card again. The reset value is 00. Reset value = 0x 000X X000 50 AT83C26 7511B–SCR–10/05 AT83C26 Table 30. SC4_CFG2 () 7 6 5 4 3 2 1 0 ART4 X CARDRST4 CARDCK4 CKSTOP4 CKS42 CKS41 CKS40 Bit Number Bit Mnemonic 7 ART4 Description Automatic Reset Transition Set this bit to have the CRST4 pin changed according to activation sequence. Clear this bit to have the CRST4 pin immediately following the value programmed in CARDRST4. 6 X 5 CARDRST4 Card Reset Set this bit to enter a reset sequence according to ART4 bit value. Clear this bit to drive a low level on the CRST4 pin. Card Clock 4 CARDCK4 Set this bit to set a high level on the CCLK4 pin (according to CKSTOP4 bit value). Clear this bit to drive a low level on the CCLK4 pin. CARD Clock Stop 3 CKSTOP4 Set this bit to stop CCLK4 according to CARDCK4. This can be used to set asynchronous cards in powerdown mode (GSM) or to drive CCLK4 by software. Clear this bit to have CCLK4 running according to CKS4. This can be used to activate asynchronous cards. Note: When this bit is changed a special logic ensures that no glitch occurs on the CCLK4 pin and actual configuration changes can be delayed by half a period to two periods of CCLK4. Interface 4Card Clock Selection CKS4 [2:0] = 0: CCLK4 = CLK (then the maximum frequency is 24 MHz) CKS4 [3:0] = 1: CCLK4 = DCCLK CKS4 [3:0] = 2: CCLK4 = DCCLK / 2 2-0 CKS4[2:0] CKS4 [3:0] = 3: CCLK4 = DCCLK / 4 CKS4 [3:0] = 4: CCLK4 = A2 CKS4 [3:0] = 5: CCLK4 = A2 / 2 CKS4 [3:0] = 6: CCLK4 = CLK / 2 CKS4 [3:0] = 7: CCLK4 = CLK / 4 The reset value is 0. Reset value = 0x 0X00 1000 Notes: 1. When CKS4 value is changed a special logic insures no glitch occurs on the CCLK4 pin and actual configuration changes can be delayed by half a period to two periods of CCLK4. 2. CCLK4 must be stopped with CKSTOP4 bit before switching from CKS4 = (0, 1, 2, 3, 6, 7) to CKS4 = (4, 5) or vice versa. 51 7511B–SCR–10/05 Table 31. SC5_CFG0() 7 6 5 4 3 2 1 0 VCARD_INT5 VCARD_OK5 ATRERR5 X X VCARDERR5 VCARD51 VCARD50 Bit Number Bit Mnemonic 7 VCARD_INT5 Description SC5 voltage interrupt This bit is set when VCARD_OK5 bit is set. This bit is cleared when read by the micro controller. 6 VCARD_OK5 SC5 Voltage Status This bit is set by the LDO5 when the output voltage remains within the voltage range specified by VCARD5[1:0] bits. It is cleared otherwise. Answer to Reset Interrupt for SC5 5 ATRERR5 This bit is set when the card clock counter overflows (no falling edge on CIO5 is received before the overflow of the card clock counter). This bit is cleared by hardware when this register is read. It can be set by software for test purpose. 4 X 3 X 2 VCARDERR5 Interface 5 Card Out of Range Voltage Interrupt This bit is set when the output voltage on CVCCN goes out of the voltage range specified by VCRDN field. It can be set by software for test purpose and deactivate the card. This bit is cleared by hardware when this register is read. It cannot be cleared by software. The reset value is 0. Interface 5 Card Voltage Selection VCRD5[1:0] = 00: 0V VCRD5[1:0] = 01: 1.8V class C 1-0 VCARD5[1:0] VCRD5[1:0] = 10: 3V class B VCRD5[1:0] = 11: 5V class A No card deactivation is performed when the voltage is changed. The micro controller should deactivate the card before changing the voltage and activating the card again. The reset value is 00. Reset value = 0x 000X X000 52 AT83C26 7511B–SCR–10/05 AT83C26 Table 32. SC5_CFG2 () 7 6 5 4 3 2 1 0 ART5 X CARDRST5 CARDCK5 CKSTOP5 CKS52 CKS51 CKS50 Bit Number Bit Mnemonic 7 ART5 Description Automatic Reset Transition Set this bit to have the CRST5 pin changed according to activation sequence. Clear this bit to have the CRST5 pin immediately following the value programmed in CARDRST5. 6 X 5 CARDRST5 Card Reset Set this bit to enter a reset sequence according to ART5 bit value. Clear this bit to drive a low level on the CRST5 pin. Card Clock 4 CARDCK5 Set this bit to set a high level on the CCLK5 pin (according to CKSTOP5 bit value). Clear this bit to drive a low level on the CCLK5 pin. CARD Clock Stop 3 CKSTOP5 Set this bit to stop CCLK5 according to CARDCK5. This can be used to set asynchronous cards in powerdown mode (GSM) or to drive CCLK5 by software. Clear this bit to have CCLK5 running according to CKS5. This can be used to activate asynchronous cards. Note: When this bit is changed a special logic ensures that no glitch occurs on the CCLK5 pin and actual configuration changes can be delayed by half a period to two periods of CCLK5. Interface 5Card Clock Selection CKS5 [2:0] = 0: CCLK5 = CLK (then the maximum frequency is 24 MHz) CKS5 [3:0] = 1: CCLK5 = DCCLK CKS5 [3:0] = 2: CCLK5 = DCCLK / 2 2-0 CKS5[2:0] CKS5 [3:0] = 3: CCLK5 = DCCLK / 4 CKS5 [3:0] = 4: CCLK5= A2 CKS5 [3:0] = 5: CCLK5 = A2 / 2 CKS5 [3:0] = 6: CCLK5 = CLK / 2 CKS5 [3:0] = 7: CCLK5 = CLK / 4 The reset value is 0. Reset value = 0x 0X00 1000 Notes: 1. When CKS5 value is changed a special logic insures no glitch occurs on the CCLK5 pin and actual configuration changes can be delayed by half a period to two periods of CCLK5. 2. CCLK5 must be stopped with CKSTOP5 bit before switching from CKS5 = (0, 1, 2, 3, 6, 7) to CKS5 = (4, 5) or vice versa. 53 7511B–SCR–10/05 Table 33. TIMER_MSB (Timer MSB for SC1, SC2, SC3, SC4, SC5) 7 6 5 4 3 2 1 0 Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit Number Bit Mnemonic 7-0 Bits 15 - 8 Description Timer MSB (bits 15 to 8) Reset value = 0x 0000 0001 Table 34. TIMER_LSB (Timer LSB for SC1, SC2, SC3, SC4, SC5) 7 6 5 4 3 2 1 0 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Bit Number Bit Mnemonic 7-0 bits 7 - 0 Description Timer LSB (bits 7to 0) Reset value = 0x 1001 0000 Table 35. CAPTURE_MSB (Capture MSB for SC1, SC2, SC3, SC4, SC5) 7 6 5 4 3 2 1 0 bit 15 bit 14 bit 13 bit 12 bit 11 bit 10 bit 9 bit 8 Bit Number Bit Mnemonic 7-0 bits 15 - 8 Description See Section “Software activation for SCn (n=1, 2, 3, 4, 5) interfaces and ARTn bit = 1”, page 25 Reset value = 0x 0000 0000 Table 36. CAPTURE_LSB (Capture LSB for SC1, SC2, SC3, SC4, SC5) 7 6 5 4 3 2 1 0 bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 Bit Number Bit Mnemonic 7-0 bits 7 - 0 Description See Section “Software activation for SCn (n=1, 2, 3, 4, 5) interfaces and ARTn bit = 1”, page 25 Reset value = 0x 0000 0000 54 AT83C26 7511B–SCR–10/05 AT83C26 Table 37. IO_SELECT (Selection byte for IO) 7 6 5 4 3 2 1 0 X X X X IOSEL3 IOSEL2 IOSEL1 IOSEL0 Bit Number Bit Mnemonic 7 X 6 X 5 X 4 X Description IO Selection 3-0 IOSEL[3:0] This field indicates the IO routing between the host and the Smart Card Interfaces when activated, seeTable 38 and IODISn value (n=1, 2, 3, 4, 5). When no host IO is routed to a smart card pin, this pin is driven according to the Interface register. See Section “CIO, CC4, CC8 controller”, page 15. Reset value = 0x XXXX 1000 Table 38. IO Selection IOSEL[3:0] IO1 IO2 AUX1 AUX2 0000 CIO1 - (1) - (1) - (1) 0001 CIO2 - (1) - (1) - (1)- 0010 CIO3 - (1) - (1) - (1) 0011 CIO4 - (1) - (1) - (1) 0100 CIO5 - (1) - (1) - (1) 0101 CIO1 CIO2 CC41 CIO3/CC42 0110 CIO1 CIO2 CC41 CIO4 0111 CIO1 CIO2 CC41 CIO5 1000 CIO1 CIO2 CC41 CC81 1001 CIO1 CIO3 CC41 CC81 1010 CIO1 CIO4 CC41 CC81 1011 CIO1 CIO5 CC41 CC81 1100 CIO1 CIO5 CIO3/CC42 CIO4 1101 CIO2 CIO5 CIO3/CC42 CIO4 1110 CIO2 CIO4 CIO3/CC42 CRST3/CC82 1111 CIO2 CIO5 CIO3/CC42 CRST3/CC82 Reset value for IOSEL[3:0]= 0x1000 55 7511B–SCR–10/05 Note: 1. If no input (IO1, IO2, AUX1, AUX2) is selected for a SCIB pin (CIOn, CC4n CC8n), and if the smart card interface is started, the electrical level on the SCIB pin corresponds to the CARDIOn, CARDC4n or CARDC8n bit value. 2. For IOSEL[3:0] = 0xOE and IOSEL[3:0] = 0x0F, the CARDRST3 bit must be set to connect AUX2 to CRST3/CC82 pin. 56 AT83C26 7511B–SCR–10/05 AT83C26 Table 39. INTERFACEB () 7 6 5 4 3 2 1 0 X CARDC82 CARDIO5 CARDIO4 CARDIO3/CAR DC42 CARDIO2 DEMBOOSTB1 DEMBOOSTB0 Bit Number Bit Mnemonic 7 X 6 CARDC82 Description Set this bit to drive the CRST3/CC82 pin High with the on-chip pull-up (according to IODIS2 bit value). The pin can then be an input (read in STATUSB register). Clear this bit to drive a low level on the CC82 pin (according to IODIS2 bit value). 5 CARDIO5 Set this bit to drive the CIO5 pin High with the on-chip pull-up when isolated from the host (See “ITDIS ()” on page 59.). The pin can then be an input (read in STATUSB register). Clear this bit to drive a low level on the CIO5 pin when isolated from the host. 4 CARDIO4 Set this bit to drive the CIO4 pin High with the on-chip pull-up when isolated from the host (See “ITDIS ()” on page 59.). The pin can then be an input (read in STATUSB register). Clear this bit to drive a low level on the CIO4/C45 pin when isolated from the host. 3 CARDIO3/ Set this bit to drive the CIO3/CC42 pin High with the on-chip pull-up when isolated from the host (See “ITDIS ()” on page 59.). The pin can then be an input (read in STATUSB register). CARDC42 Clear this bit to drive a low level on the CIO3/CC42 pin when isolated from the host. This bit is CIO3 when AUX=0 or when AUX=1 and IFN=2, otherwise it is CC42. 2 CARDIO2 Set this bit to drive the CIO2 pin High with the on-chip pull-up when isolated from the host (See “ITDIS ()” on page 59.). The pin can then be an input (read in STATUSB register). Clear this bit to drive a low level on the CIO2 pin when isolated from the host. Configuration for DC/DCB startup current. 00: Normal: 80 mA average 1-0 DEMBOOSTB[1-0] 01: Normal + 18% 10: Normal + 18% (and boost on oscillator) 11: Normal + 40% Reset value = 0x X000 0000 57 7511B–SCR–10/05 Table 40. STATUSB () - Read Only 7 6 5 4 X CARDIN2 CIO5 CIO4 Bit Number Bit Mnemonic 7 X 6 CARDIN2 5 CIO5 4 CIO4 3 CRST3/CC82 2 CIO3/CC42 1 CRST2 0 CIO2 3 2 CRST3/ CIO3/ CC82 CC42 1 0 CRST2 CIO2 Description Card Presence Status 2 This bit is set when a card is detected. It is cleared otherwise. Card CIO5 This bit provides the actual level on the CIO5 pin when read. Card CIO4 This bit provides the actual level on the CIO4 pin when read. Card CRST3 This bit provides the actual level on the CRST3 pin when read. Card CIO3 This bit provides the actual level on the CIO3 pin when read. Card CRST2 This bit provides the actual level on the CRST2 pin when read. Card CIO2 This bit provides the actual level on the CIO2 pin when read. Reset value = reset value depends on hardware configuration 58 AT83C26 7511B–SCR–10/05 AT83C26 Table 41. ITDIS () 7 6 5 4 3 2 1 0 IODIS5 IODIS4 IODIS3 IODIS2 ITDIS5 ITDIS4 ITDIS3 ITDIS2 Bit Number Bit Mnemonic Description Card I/O isolation 7 IODIS5 Set this bit to drive CIO5 pin according to CARDIO5. Clear this bit to drive the CIO5 pin connected to inputs according to IO_SELECT registers. If IOSEL config doesn’t link an input to CIO5, CIO5 outputs CARDIO5 value. Card I/O isolation 6 IODIS4 Set this bit to drive CIO4 pin according to CARDIO4. Clear this bit to drive the CIO4 pin connected to inputs according to IO_SELECT registers. If IOSEL config doesn’t link an input to CIO4, CIO4 outputs CARDIO4 value. Card I/O isolation 5 IODIS3 Set this bit to drive CIO3 pin according to CARDIO3. Clear this bit to drive the CIO3 pin connected to inputs according to IO_SELECT registers. If IOSEL config doesn’t link an input to CIO3, CIO3 outputs CARDIO3 value. Card I/O isolation 4 IODIS2 Set this bit to drive the CIO2, CC42, CC82 pins according to CARDIO2, CARDC42, CARDC82 respectively. Clear this bit to drive the CIO2, CC42 and CC82 pins connected to inputs according to IO_SELECT register. If IOSEL config doesn’t link an input to CIO2, CIO2 outputs CARDIO2 value. Interrupt Disable of Smart Card Interface 5 3 ITDIS5 Set this bit to disable interrupts from the interface 5 (the flags are set but INT pin is not driven). Clear this bit to allow interrupts. Interrupt Disable of Smart Card Interface 4 2 ITDIS4 Set this bit to disable interrupts from the interface 4(the flags are set but INT pin is not driven). Clear this bit to allow interrupts. Interrupt Disable of Smart Card Interface 3 1 ITDIS3 Set this bit to disable interrupts from the interface 3 (the flags are set but INT pin is not driven). Clear this bit to allow interrupts. Interrupt Disable of Smart Card Interface 2 0 ITDIS2 Set this bit to disable interrupts from the interface 2(the flags are set but INT pin is not driven). Clear this bit to allow interrupts. Reset value = 0x 1111 0010 59 7511B–SCR–10/05 Table 42. DCDCB (Config Interface B Byte 2) 7 6 SHUTDOWNB Bit Number 5 VDCB_INT Bit Mnemonic VDCB_OK 4 0 3 ICCADJB 2 STEPREGB 1 0 VDCB1 VDCB0 Description Shutdown DCDCB 7 SHUTDOWNB Set this bit to reduce the power consumption. An automatic de-activation sequence will be done. Clear this bit to enable VDCB. The reset value is 0. DC/DC B voltage interrupt 6 VDCB_INT This bit is set when VCARD_OKB bit is set. This bit is cleared when read by the micro controller. The reset value is 0. 5 VDCB_OK DC/DC B Voltage Status This bit is set by the DCDC when the output voltage remains within the voltage range specified by VDCB[1:0] bits. It is recommended to wait for this bit to be set before activating a card at the corresponding voltage. It is cleared otherwise. The reset value is 0. 4 0 This bit must be always at 0. CICC overflow adjust This bit controls the DC/DCB sensitivity to any overflow current. 3 ICCADJB Set this bit to decrease the DC/DCB sensitivity (CICC_ovf is increased by about 20%). Clear this bit to have a normal configuration. The reset value is 0. DC/DC B Step-up Regulator Mode 2 STEPREGB Set this bit to permanently disable the step-up converter (CVCC is stable only if VCC is sufficiently higher than CVCC). This bit must always be set if no external self is used. Clear this bit to enable the automatic step-up converter (CVCC is stable even if VCC is not higher than CVCC). The reset value is 0. DC/DC B Voltage Selection VDCB[1:0] = 00: 0V VDCB[1:0] = 01: 2.2V (for Class C) VDCB[1:0] = 10: 3.2V (for Class B and C) VDCB[1:0] = 11: 5.2V (for Class A, B and C) 1-0 VDCB[1:0] No card deactivation is performed when the voltage is changed. The voltage must be set higher than the voltage of all the active cards. If a Class A card is deactivated and the remaining cards are in Class B or C, VDCB can be reduced to 3.2V to reduce power consumption. If a Class B card is deactivated and the remaining cards are in Class C, VDCB can be reduced to 2.2V to reduce power consumption.It is not reset when cards are deactivated. It must be cleared by the micro controller to stop DC/DC B (e.g. to reduce power consumption). The reset value is 00. Reset value = 0x 0000 0000 60 AT83C26 7511B–SCR–10/05 AT83C26 Table 43. LDO 7 6 5 4 3 2 1 0 IPLUS5 IPLUS4 IPLUS3 IPLUS2 1 1 1 1 Bit Number Bit Mnemonic Description 7 IPLUS5 If set, this bit increases the startup and overflow current of LDO5 (+60%) 6 IPLUS4 If set, this bit increases the startup and overflow current of LDO4 (+60%) 5 IPLUS3 If set, this bit increases the startup and overflow current of LDO3 (+60%) 4 IPLUS2 If set, this bit increases the startup and overflow current of LDO2 (+60%) 3 1 Do not clear this bit. 2 1 Do not clear this bit. 1 1 Do not clear this bit. 0 1 Do not clear this bit. Reset value = 0x 0000 1111 61 7511B–SCR–10/05 Table 44. SLEW_CTRL_1(Slew control for SC1 and SC2) 7 6 5 4 3 2 1 0 CCLK2_SLEW_CT RL1 CCLK2_SLEW_CT RL0 CIO2_SLEW_CT RL1 CIO2_SLEW_CT RL0 CCLK1_SLEW_CT RL1 CCLK1_SLEW_CTR L0 CIO1_SLEW_CTR L1 CIO1_SLEW_CT RL0 Bit Number Bit Mnemonic Description 0 0: Mode 1 (optimum for CVCC2=5V) 0 1: Mode 2 (optimum for CVCC2=3V) 7-6 CCLK2_SLEW_CTRL[1-0] 1 0: Mode 3 (optimum for CVCC2=1.8V) 1 1: Automatic mode The reset value is 11. 0 0: Mode 1 (optimum for CVCC2=5V) 0 1: Mode 2 (optimum for CVCC2=3V) 5-4 CIO2_SLEW_CTRL[1-0] 1 0: Mode 3 (optimum for CVCC2=1.8V) 1 1: Automatic mode The reset value is 11. 0 0: Mode 1 (optimum for CVCC1=5V) 0 1: Mode 2 (optimum for CVCC1=3V) 3-2 CCLK1_SLEW_CTRL[1-0] 1 0: Mode 3 (optimum for CVCC1=1.8V) 1 1: Automatic mode The reset value is 11. 0 0: Mode 1 (optimum for CVCC1=5V) 0 1: Mode 2 (optimum for CVCC1=3V) 1-0 CIO1_SLEW_CTRL[1-0] 1 0: Mode 3 (optimum for CVCC1=1.8V) 1 1: Automatic mode The reset value is 11. Reset value = 0x 1111 1111 62 AT83C26 7511B–SCR–10/05 AT83C26 Table 45. SLEW_CTRL_2 (Slew control for SC3 and SC4) 7 6 5 4 3 2 1 0 CCLK4_SLEW_CTR L1 CCLK4_SLEW_CT RL0 CIO4_SLEW_CT RL1 CIO4_SLEW_CT RL0 CCLK3_SLEW_CTR L1 CCLK3_SLEW_CTRL 0 CIO3_SLEW_CT RL1 CIO3_SLEW_CTR L0 Bit Number Bit Mnemonic Description 0 0: Mode 1 (optimum for CVCC4=5V) 0 1: Mode 2 (optimum for CVCC4=3V) 7-6 CCLK4_SLEW_CTRL[1-0] 1 0: Mode 3 (optimum for CVCC4=1.8V) 1 1: Automatic mode The reset value is 11. 0 0: Mode 1 (optimum for CVCC4=5V) 0 1: Mode 2 (optimum for CVCC4=3V) 5-4 CIO4_SLEW_CTRL[1-0] 1 0: Mode 3 (optimum for CVCC4=1.8V) 1 1: Automatic mode The reset value is 11. 0 0: Mode 1 (optimum for CVCC3=5V) 0 1: Mode 2 (optimum for CVCC3=3V) 3-2 CCLK3_SLEW_CTRL[1-0] 1 0: Mode 3 (optimum for CVCC3=1.8V) 1 1: Automatic mode The reset value is 11. 0 0: Mode 1 (optimum for CVCC3=5V) 0 1: Mode 2 (optimum for CVCC3=3V) 1-0 CIO3_SLEW_CTRL[1-0] 1 0: Mode 3 (optimum for CVCC3=1.8V) 1 1: Automatic mode The reset value is 11. Reset value = 0x 1111 1111 63 7511B–SCR–10/05 Table 46. SLEW_CTRL_3 (Slew control for SC5) 7 6 5 4 3 2 1 0 X X X X CCLK5_SLEW_CTR L1 CCLK5_SLEW_CTR L0 CIO5_SLEW_CTR L1 CIO5_SLEW_CT RL0 Bit Number Bit Mnemonic 7-4 X Description 0 0: Mode 1 (optimum for CVCC5=5V) 0 1: Mode 2 (optimum for CVCC5=3V) 3-2 CCLK5_SLEW_CTRL[1-0] 1 0: Mode 3 (optimum for CVCC5=1.8V) 1 1: Automatic mode The reset value is 11. 0 0: Mode 1 (optimum for CVCC5=5V) 0 1: Mode 2 (optimum for CVCC5=3V) 1-0 CIO5_SLEW_CTRL[1-0] 1 0: Mode 3 (optimum for CVCC5=1.8V) 1 1: Automatic mode The reset value is 11. Reset value = 0x XXXX 1111 64 AT83C26 7511B–SCR–10/05 AT83C26 Electrical Characteristics Absolute Maximum Ratings * *NOTICE: Ambient Temperature Under Bias: ....................- 40°C to 85°C Storage Temperature: ................................... -65°C to +150°C Voltage on VCC: ........................................ VSS -0.5V to +6.0V Voltage on SCIB pins (***): ......... CVSS -0.5V to CVCC + 0.5V Voltage on host interface pins:.......VSS -0.5V to EVCC + 0.5V Voltage on other pins: ...................... VSS -0.5V to VCC + 0.5V Stresses at or above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions may affect device reliability. Power Dissipation value is based on the maximum allowable die temperature and the thermal resistance of the package. Max Power Dissipation: .............................................. 350mW Thermal resistor of QFN package (**)......................24°C/W Thermal resistor of VQFP package...........................67°C/W (**) Exposed die attached pad must be soldered to ground Thermal resistor is measured on multi-layer PCB with 0 m/s air flow. (***) including shortages between any groups of smart card pins. AC/DC Parameters EVCC connected to host power supply: from 2.5V to 5.5V. TA = -40°C to +85°C; VSS = 0V; VCC = 3V to 5.5V. CLASS A (5V) for smart card 1, 2, 3, 4, 5 supplied with CVCC (+/- 8%) CLASS B (3V)for smart card 1, 2, 3, 4, 5 supplied with CVCC (+/- 8%) CLASS C (1.8V) for smart card 1, 2, 3, 4, 5 supplied with CVCC (+/- 8%) Table 47. Core (VCC) Symbol Parameter Min Typ Max Unit VPFDP Power fail high level threshold 2.46 2.59 2.71 V VPFDM Power fail low level threshold 2.26 2.40 2.56 V 100 190 300 mV µs Hysteresis Delta between (VPFDP - VPFDM) trise VCC rise time 1us 10s tfall VCC fall time 100us 10s Icc operating Operating current 15 mA Test Conditions DCDCA, DCDCB and LDOs on with load= 0 mA VCC = 5.5V SHUTDOWNA bit = 1 Icc power down Power down current 30 µA SHUTDOWNB bit = 1 VCC = 5.5V 65 7511B–SCR–10/05 Table 48. Host Interface (IO1, IO2, AUX1, AUX2, CLK, A2/CK, A1/RST, INT) Symbol Parameter VIL Input Low-voltage VIH Input High Voltage VOL Output low voltage VOH Output High Voltage Min Typ Max Unit 0.8 V 2.2 Test Conditions V 0.3 VCC - 0.7V V IOL = -500µA V IOH = +30µA Table 49. Host Interface (SCL, SDA, RESET) Symbol Parameter VIL Input Low-voltage VIH Input High Voltage VOL Output low voltage Min Typ Max Unit 0.8 V 2.2 Test Conditions V 0.3 V IOL = -3mA Table 50. Smart Card 1 Class A, 5V (CVCC1) Symbol Parameter CVCC Min Typ Max Unit Test Conditions 4.6 5 5.4 V Load = 60mA VCC = 3V to 5.5V if STEPREG = 0 VCC > 5.3V if STEPREG = 1 70 120 200 mA Ripple on CVCC 70 200 mV Spikes on CVCC 0.5 V Smart card voltage Card Supply Current Overflow: CICC_ovf ICCADJA = 0 (reset value) With low ESR capacitance (0.1 Ohms max) Vcardok up Vcardok high level threshold 5 V Vcardok down Vcardok low level threshold 4.65 V TVHL CVCC valid to 0.4V 100 500 μs CL =10μF TVLH CVCC 0 to valid 1000 4000 μs CL = 10μF Table 51. Smart Card 1 Class B, 3V (CVCC1) Symbol CVCC 66 Parameter Min Smart card voltage 2.76 Typ Max Unit Test Conditions 3.24 V Load = 60mA VCC = 3V to 5.5V if STEPREG = 0 VCC > 3.3V if STEPREG = 1 AT83C26 7511B–SCR–10/05 AT83C26 Table 51. Smart Card 1 Class B, 3V (CVCC1) (Continued) Symbol Min Typ Max Unit 70 115 200 mA Ripple on CVCC 60 200 mV Spikes on CVCC 0.4 V 3 V Vcardok low level threshold 2.82 V TVHL CVCC valid to 0.4V 100 400 μs CL =10μF TVLH CVCC 0 to valid 300 2000 μs CL = 10μF CICC_ovf Parameter Card Supply Current Overflow: ICCADJA = 0 (reset value) Vcardok up Vcardok high level threshold Vcardok down Test Conditions With low ESR capacitance (0.1 Ohms max) Table 52. Smart Card 1 Class C, 1.8V (CVCC1) Symbol CVCC CICC_ovf Parameter Min Smart card voltage 1.656 Max Unit Test Conditions 1.944 V Load = 35mA 90 150 mA Ripple on CVCC 20 200 mV Spikes on CVCC 0.05 V 1.8 V 1.69 V Card Supply Current Overflow: ICCADJA = 0 (reset value) 50 Vcardok up Vcardok high level threshold Vcardok down Vcardok low level threshold TVHL CVCC valid to 0.4V TVLH CVCC 0 to valid 30 Typ 80 400 μs CL =10μF 220 2000 μs CL = 10μF Table 53. Smart Card 2 Class A, 5V (CVCC2) Symbol CVCC CICC_ovf Parameter Smart card voltage Card Supply Current Overflow: ICCADJB = 0 (reset value) Ripple on CVCC Min Typ Max Unit Test Conditions 4.6 5 5.4 V Load = 60mA 70 120 200 mA 30 200 mV Spikes on CVCC V Vcardok up Vcardok high level threshold 5 V Vcardok down Vcardok low level threshold 4.65 V CVCC valid to 0.4V 150 TVHL 500 μs CL =2.2μF 67 7511B–SCR–10/05 Table 53. Smart Card 2 Class A, 5V (CVCC2) (Continued) Symbol TVLH Parameter Min CVCC 0 to valid Typ Max Unit 200 2000 μs Test Conditions CL = 2.2μF Table 54. Smart Card 2 Class B, 3V (CVCC2) Symbol CVCC Parameter Min Typ Max Unit Test Conditions Smart card voltage 2.76 3 3.24 V Load = 60mA 70 120 200 mA 30 200 mV Card Supply Current Overflow: CICC_ovf ICCADJB = 0 (reset value) Ripple on CVCC Spikes on CVCC V Vcardok up Vcardok high level threshold 3 V Vcardok low level threshold 2.8 V TVHL CVCC valid to 0.4V 100 500 μs CL =2.2μF TVLH CVCC 0 to valid 100 1000 μs CL = 2.2μF Vcardok down Table 55. Smart Card 2 Class C, 1.8V (CVCC2) Symbol CVCC Parameter Min Typ Max Unit Test Conditions Smart card voltage 1.656 1.8 1.944 V Load = 35mA 70 120 200 mA 30 200 mV Card Supply Current Overflow: CICC_ovf ICCADJB = 0 (reset value) Ripple on CVCC Spikes on CVCC V Vcardok up Vcardok high level threshold Vcardok down Vcardok low level threshold 1.8 V 1.69 V TVHL CVCC valid to 0.4V 70 500 μs CL =2.2μF TVLH CVCC 0 to valid 80 1000 μs CL = 2.2μF Table 56. Smart Card 3, 4, 5 Class A, 5V (CVCC3, CVCC4, CVCC5) Symbol CVCC CICC_ovf 68 Parameter Smart card voltage Card Supply Current Overflow: ICCADJB = 0 (reset value) Min Typ Max Unit Test Conditions 4.6 5 5.4 V Load = 30mA 70 120 200 mA AT83C26 7511B–SCR–10/05 AT83C26 Table 56. Smart Card 3, 4, 5 Class A, 5V (CVCC3, CVCC4, CVCC5) (Continued) Symbol Parameter Min Ripple on CVCC Typ Max Unit 30 200 mV Spikes on CVCC Test Conditions V Vcardok up Vcardok high level threshold 5 V Vcardok down Vcardok low level threshold 4.65 V TVHL CVCC valid to 0.4V 50 500 μs CL =470nF TVLH CVCC 0 to valid 200 2000 μs CL = 470nF Table 57. Smart Card 3, 4, 5 Class B, 3V (CVCC3, CVCC4, CVCC5) Symbol CVCC CICC_ovf Parameter Min Typ Max Unit Test Conditions Smart card voltage 2.76 3 3.24 V Load = 30mA 70 120 200 mA 30 200 mV Card Supply Current Overflow: ICCADJB = 0 (reset value) Ripple on CVCC Spikes on CVCC V Vcardok up Vcardok high level threshold 3 V Vcardok low level threshold 2.8 V TVHL CVCC valid to 0.4V 40 500 μs CL =470nF TVLH CVCC 0 to valid 100 2000 μs CL = 470nF Vcardok down Table 58. Smart Card 3, 4, 5 Class C, 1.8V (CVCC3, CVCC4, CVCC5) Symbol CVCC CICC_ovf Parameter Min Typ Max Unit Test Conditions Smart card voltage 1.656 1.8 1.944 V Load = 15mA 70 120 200 mA 30 200 mV Card Supply Current Overflow: ICCADJB = 0 (reset value) Ripple on CVCC Spikes on CVCC Vcardok up Vcardok high level threshold Vcardok down Vcardok low level threshold V 1.8 V 1.69 V TVHL CVCC valid to 0.4V 30 500 μs CL =470nF TVLH CVCC 0 to valid 100 2000 μs CL = 470nF 69 7511B–SCR–10/05 Table 59. Smart Card 1, 2, 3, 4, 5 Clock (CCLK1, CCLK2, CCLK3, CCLK4, CCLK5) Symbol Parameter Min Typ Max Unit 0.3 V Test Conditions Class A: IOL = -200µA VOL Output low voltage Class B: IOL = -200µA Class C: IOL = -200µA Class A: IOH = 200µA VOH Output High Voltage 0.8 CVCC V Class B: IOH = 200µA Class C: IOH = 200µA CL = 30pF Class A tR Rise time 16 ns CL = 30pF Class B CL = 30pF Class C CL = 30pF Class A tF Fall time 16 ns CL = 30pF Class B CL = 30pF Class C Low level voltage stability (taking into account PCB design) High level voltage stability (taking into account PCB design) CCLK -0.25 0.6 -0.25 0.4 -0.25 0.4 CVCC-0.5 CVCC+0.25 V 24 MHz Smart card clock frequency Class A V Class B Class C CVCC= Class A, Class B or Class C Table 60. Smart Card n I/Os (CIOn, CC4n, CC8n, CRSTn) (n =1, 2, 3, 4, 5) Symbol Parameter Min VIL Input Low-voltage VIH Input High Voltage VOL Output Low-voltage VOH Output High Voltage Typ Max Unit -0.5 0.15 CVCC V 0.7 CVCC CVCC + 0.5 V 0.3 V Test Conditions IOL = -1mA Class A: IOH = 20µA 0.8 CVCC V Class B: IOH = 20µA Class C: IOH = 20µA IIL Input Low Current IIH Input High Current IOS Output Short Circuit Current Low level voltage stability (taking into account PCB design) High level voltage stability (taking into account PCB design) tR Rise time 500 µA -20 +20 μA -15 +15 mA -0.25 0.6 -0.25 0.4 -0.25 0.4 CVCC-0.5 CVCC+0.25 V 100 μs Short to GND or CVCC Class A V Class B Class C CVCC= Class A, Class B or Class C CL = 30pF Class A CL = 30pF Class B CL = 30pF Class C 70 AT83C26 7511B–SCR–10/05 AT83C26 Table 60. Smart Card n I/Os (CIOn, CC4n, CC8n, CRSTn) (n =1, 2, 3, 4, 5) (Continued) Symbol tF Parameter Min Typ Fall time Max Unit 100 μs Test Conditions CL = 30pF Class A CL = 30pF Class B CL = 30pF Class C Table 61. Card Presence (CPRES1, CPRES2) Symbol Parameter Min Typ Max Unit Test Conditions Short to VSS IOL1 CPRES1 weak pull-up output current 3 10 25 µA PULLUP1 = 1: Internal pull-up active Short to VSS RCPRES2 CPRES2 weak pull-up output current 3 10 25 µA PULLUP2 = 1: Internal pull-up active Table 62. DCDCB Symbol Parameter CVCCB DCDCB output voltage Min Typ 4.9 5.3 3 3.35 2 2.4 Ripple on CVCCB Max Unit Load = 70mA V mV 5.3 Class A 3.35 V 2.4 Vcardok down Class B Class C 4.9 Vdcbok low level threshold Load = 40mA Load = 10mA 200 Vcardok up Vdcbok high level threshold Test Conditions Class A 3.1 V 2.1 Class B Class C TVHL VDCB valid to 0 100 500 μs TVLH VDCB 0 to valid 1000 4000 μs Max Unit Table 63. Slew rate on CIOn with CVCCn= 5V (n=1, 2, 3, 4, 5), Mode 1 Symbol tR/F Parameter Rise time/ Fall time with CIOn_SLEW_CTRL[1-0] = 00 (5V) Min Typ 12 ns 7 ns 2.7 ns Test Conditions or CIOn_SLEW_CTRL[1-0] = 11(mode auto) tR Rise time with CIOn_SLEW_CTRL[1-0] = 01 (3V) tR Rise time with CIOn_SLEW_CTRL[1-0] = 10 (1.8V) 71 7511B–SCR–10/05 Table 64. Slew rate on CIOn with CVCCn= 3V (n=1, 2, 3, 4, 5), Mode 2 Symbol tR/F Parameter Min Rise time/ Fall time with CIOn_SLEW_CTRL[1-0] = 01 (3V) Typ Max Unit 9 ns 4 ns Test Conditions or CIOn_SLEW_CTRL[1-0] = 11(mode auto) tR Rise time with CIOn_SLEW_CTRL[1-0] = 10 (1.8V) Table 65. Slew rate on CIOn with CVCCn= 1.8V (n=1, 2, 3, 4, 5), Mode 3 Symbol tR/F Parameter Min Rise time/ Fall time with CIOn_SLEW_CTRL[1-0] = 10 (1.8V) Typ Max 8.5 Unit Test Conditions ns or CIOn_SLEW_CTRL[1-0] = 11(mode auto) Table 66. Slew rate on CCLKn with CVCCn= 5V (n=1, 2, 3, 4, 5), Mode 1 Symbol tR/F Parameter Min Rise time/ Fall time with CCLKn_SLEW_CTRL[1-0] = 00 (5V) Typ Max Unit 12 ns 7 ns 2.7 ns Test Conditions or CCLKn_SLEW_CTRL[1-0] = 11(mode auto) tR/F Rise time/ Fall time with CCLKn_SLEW_CTRL[1-0] = 01 (3V) tR/F Rise time/ Fall time with CCLKn_SLEW_CTRL[1-0] = 10 (1.8V) Table 67. Slew rate on CCLKn with CVCCn= 3V (n=1, 2, 3, 4, 5), Mode 2 Symbol tR/F Parameter Min Rise time/ Fall time with CCLKn_SLEW_CTRL[1-0] = 01 (3V) Typ Max Unit 9 ns 4 ns Test Conditions or CCLKn_SLEW_CTRL[1-0] = 11(mode auto) tR/F Rise time/ Fall time with CCLKn_SLEW_CTRL[1-0] = 10 (1.8V) Table 68. Slew rate on CCLKn with CVCCn= 1.8V (n=1, 2, 3, 4, 5), Mode 3 Symbol tR Parameter Rise time/ Fall time with CCLKn_SLEW_CTRL[1-0] = 10 (1.8V) Min Typ 8.5 Max Unit Test Conditions ns or CCLKn_SLEW_CTRL[1-0] = 11(mode auto) 72 AT83C26 7511B–SCR–10/05 AT83C26 Typical Application VCC 100nF 4.7µF 10µH 100nF 2.2µF VSS Px.y RESET INT0 CVSS LIA INT Card 1 2.2µF VSS 4 * Px,y IO1,IO2, AUX1, AUX2 CCLK A2/CK CRST0 A1/RST Card 3..5 Card 2 CVSS Px.y LIB BYPASS VSS CLK_OUT CRST3..5 CIO3..5 CCLK3..5 CRST2 CIO2, CC42, CC82 CPRES2 CCLK2 CLK XTAL2 10µH 10µF 100nF VCC VSS 4 to 48 MHz VSS 10µF VSS VSS VSS CRST1 XTAL1 100nF 3 * 470nF CVCCB CVCCB CVCCBIN Smart Card Interface TWI SCL SDA VSS CVCC1 CVCC1 CVCC1IN CRST1 CIO1, CC41, CC81 CPRES1 CCLK1 AT83C26 CVCC2 CVCC3..5 EVCC 100k 4.7k HOST 4.7k VCC VSS VSS VSS VSS VCC VSS 4.7µH 100nF VSS CVSS LI A1/RST Vcc or Vss VSS A2/CK VCC VSS CVCC1 CVCC1IN A0 CLK 10µF 100nF CVSS SCL SDA AT83C24 DVCC 100nF RESET PRES/INT IO, C4, C8 CVSS CRST CIO, CC4, CC8 CPRES CCLK VSS Card 0 73 7511B–SCR–10/05 Ordering Information Part Number Supply Voltage Temperature Range Package Packing AT83C26-PLTUL 3V to 5.5V Industrial MLF48 Tray AT83C26-PLRUL 3V to 5.5V Industrial MLF48 Tape&Reel AT83C26-RKTUL 3V to 5.5V Industrial VQFP48 Tray AT83C26-RKRUL 3V to 5.5V Industrial VQFP48 Tape&Reel Part Number Supply Voltage Temperature Range Package Packing AT83C26-PLTEL 3V to 5.5V 25°C MLF48 Tray AT83C26-RKTEL 3V to 5.5V 25°C VQFP48 Tray Samples 74 AT83C26 7511B–SCR–10/05 AT83C26 Package Drawings VQFP48 75 7511B–SCR–10/05 QFN48 76 AT83C26 7511B–SCR–10/05 Atmel Corporation 2325 Orchard Parkway San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 487-2600 Regional Headquarters Europe Atmel Sarl Route des Arsenaux 41 Case Postale 80 CH-1705 Fribourg Switzerland Tel: (41) 26-426-5555 Fax: (41) 26-426-5500 Asia Room 1219 Chinachem Golden Plaza 77 Mody Road Tsimshatsui East Kowloon Hong Kong Tel: (852) 2721-9778 Fax: (852) 2722-1369 Japan 9F, Tonetsu Shinkawa Bldg. 1-24-8 Shinkawa Chuo-ku, Tokyo 104-0033 Japan Tel: (81) 3-3523-3551 Fax: (81) 3-3523-7581 Atmel Operations Memory 2325 Orchard Parkway San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 436-4314 RF/Automotive Theresienstrasse 2 Postfach 3535 74025 Heilbronn, Germany Tel: (49) 71-31-67-0 Fax: (49) 71-31-67-2340 Microcontrollers 2325 Orchard Parkway San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 436-4314 La Chantrerie BP 70602 44306 Nantes Cedex 3, France Tel: (33) 2-40-18-18-18 Fax: (33) 2-40-18-19-60 ASIC/ASSP/Smart Cards 1150 East Cheyenne Mtn. Blvd. Colorado Springs, CO 80906, USA Tel: 1(719) 576-3300 Fax: 1(719) 540-1759 Biometrics/Imaging/Hi-Rel MPU/ High Speed Converters/RF Datacom Avenue de Rochepleine BP 123 38521 Saint-Egreve Cedex, France Tel: (33) 4-76-58-30-00 Fax: (33) 4-76-58-34-80 Zone Industrielle 13106 Rousset Cedex, France Tel: (33) 4-42-53-60-00 Fax: (33) 4-42-53-60-01 1150 East Cheyenne Mtn. Blvd. Colorado Springs, CO 80906, USA Tel: 1(719) 576-3300 Fax: 1(719) 540-1759 Scottish Enterprise Technology Park Maxwell Building East Kilbride G75 0QR, Scotland Tel: (44) 1355-803-000 Fax: (44) 1355-242-743 Literature Requests www.atmel.com/literature Disclaimer: The information in this document is provided in connection with Atmel products. No license, express or implied, by estoppel or otherwise,to anyintellectualproperty right is granted by this document or in connection with the sale of Atmel products. EXCEPT AS SET FORTH IN ATMEL’S TERMS AND CONDI-TIONS OF SALE LOCATED ON ATMEL’S WEB SITE, ATMEL ASSUMES NO LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED OR STATUTORYWARRANTY RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULARPURPOSE, OR NON-INFRINGEMENT. IN NO EVENT SHALL ATMEL BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL OR INCIDEN-TAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION, OR LOSS OF INFORMATION) ARISING OUTOF THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF ATMEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Atmel makes norepresentationsor warranties with respect to the accuracy or completeness of the contents of this document and reserves the right to make changes to specificationsand product descriptions at any time without notice. Atmel does not make any commitment to update the information contained herein. Unless specifically provided otherwise, Atmel products are not suitable for, and shall not be used in, automotive applications. Atmel’s products are not intended, authorized, or warranted for useas components in applications intended to support or sustainlife. © Atmel Corporation 2005. All rights reserved. Atmel®, logo and combinations thereof, are registered trademarks, and Everywhere You Are SM are the trademarks of Atmel Corporation or its subsidiaries. Other terms and product names may be trademarks of others. Printed on recycled paper. 7511B–SCR–10/05