ATMEL ATAR092X-YYY

Features
•
•
•
•
•
•
•
•
•
•
•
•
Extended Temperature Range for High Temperature up to 125°C
4-Kbyte ROM, 256 × 4-bit RAM
16 Bi-directional I/Os
Up to 7 External/Internal Interrupt Sources
Multifunction Timer/Counter with
– IR Remote Control Carrier Generator
– Bi-phase, Manchester and Pulse-width Modulator and Demodulator
– Phase Control Function
Programmable System Clock with Prescaler and Five Different Clock
Sources
Wide Supply-voltage Range (1.8 V to 6.5 V)
Very Low Sleep Current (< 1 µA)
Synchronous Serial Interface (2-wire, 3-wire)
Watchdog, POR and Brown-out Function
Voltage Monitoring Inclusive Lo_BAT Detect
Flash Controller ATAM893 Available (SSO20)
Low-current
Microcontroller
for Wireless
Communication
Description
The ATAR092-D is a member of Atmel’s family of 4-bit single-chip microcontrollers. It
offers the highest integration for IR and RF data communication, remote-control and
phase-control applications. The ATAR092-D is suitable as a transmitter as well as a
receiver. They contain ROM, RAM, parallel I/O ports, two 8-bit programmable multifunction timer/counters with modulator and demodulator function, voltage supervisor,
interval timer with watchdog function and a sophisticated on-chip clock generation
w i t h ex t e r n a l c l o c k i n p u t , i n t e g r a t e d R C - , 3 2 -k H z c r y s t a l - a n d 4 - M H z
crystal-oscillators.
ATAR092-D
Figure 1. Block Diagram
VSS
VDD
Brown-out protect.
RESET
Voltage monitor
External input
OSC1 OSC2
RC
Crystal
oscillators oscillators
UTCM
External
clock input
Clock management
Timer 1
interval- and
watchdog timer
Timer 2
VMI
BP10
Port 1
BP13
Data direction
BP23
Port 2
BP22
RAM
256 x 4 bit
T2I
T2O
SD
SSI
BP20/NTE
BP21
ROM
4 K x 8 bit
8/12-bit timer
with modulator
MARC4
Serial interface
4-bit CPU core
Timer 3
8-bit
timer/counter
with modulator
and demodulator
I/O bus
Data direction +
alternate function
Data direction +
interrupt control
Data direction +
alternate function
Port 4
Port 5
Port 6
BP42
BP40
BP50
BP52
INT3
INT6
T2O
INT1
SC
BP43
BP41
BP53
BP51
INT3
VMI
INT6
INT1
T2I
SD
BP60
T3O
SC
T3O
T3I
BP63
T3I
Rev. 4594C–4BMCU–12/04
Pin Configuration
Figure 2. Pinning SSO20
VDD
BP40/INT3/SC
BP53/INT1
BP52/INT1
BP51/INT6
BP50/INT6
OSC1
OSC2
BP60/T3O
BP10
1
2
3
4
5
6
7
8
9
10
20
19
18
17
16
15
14
13
12
11
VSS
BP43/INT3/SD
BP42/T2O
BP41/VMI/T2I
BP23
BP22
BP21
BP20/NTE
BP63/T3I
BP13
Pin Description
2
Name
Type
Function
Alternate Function
VDD
VSS
BP10
BP13
Pin No.
Reset State
–
Supply voltage
–
1
NA
–
Circuit ground
–
20
NA
I/O
Bi-directional I/O line of Port 1.0
–
10
Input
I/O
Bi-directional I/O line of Port 1.3
–
11
Input
BP20
I/O
Bi-directional I/O line of Port 2.0
NTE-test mode enable, see section “Master Reset”
13
Input
BP21
I/O
Bi-directional I/O line of Port 2.1
–
14
Input
BP22
I/O
Bi-directional I/O line of Port 2.2
–
15
Input
BP23
I/O
Bi-directional I/O line of Port 2.3
–
16
Input
BP40
I/O
Bi-directional I/O line of Port 4.0
SC-serial clock or INT3 external interrupt input
2
Input
17
Input
BP41
I/O
Bi-directional I/O line of Port 4.1
VMI voltage monitor input or T2I external clock
input Timer 2
BP42
I/O
Bi-directional I/O line of Port 4.2
T2O Timer 2 output
18
Input
BP43
I/O
Bi-directional I/O line of Port 4.3
SD serial data I/O or INT3-external interrupt input
19
Input
BP50
I/O
Bi-directional I/O line of Port 5.0
INT6 external interrupt input
6
Input
BP51
I/O
Bi-directional I/O line of Port 5.1
INT6 external interrupt input
5
Input
BP52
I/O
Bi-directional I/O line of Port 5.2
INT1 external interrupt input
4
Input
BP53
I/O
Bi-directional I/O line of Port 5.3
INT1 external interrupt input
3
Input
BP60
I/O
Bi-directional I/O line of Port 6.0
T3O Timer 3 output
9
Input
BP63
I/O
Bi-directional I/O line of Port 6.3
T3I Timer 3 input
12
Input
OSC1
I
Oscillator input
4-MHz crystal input or 32-kHz crystal input or
external clock input or external trimming resistor
input
7
Input
OSC2
O
Oscillator output
4-MHz crystal output or 32-kHz crystal output or
external clock input
8
NA
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Introduction
The ATAR092-D is a member of Atmel’s family of 4-bit single-chip microcontrollers.
They contain ROM, RAM, parallel I/O ports, two 8-bit programmable multifunction
timer/counters, voltage supervision, interval timer with watchdog function, a sophisticated on-chip clock generation with integrated RC-, 32-kHz crystal- and 4-MHz crystal
oscillators.
Table 1. Available Variants of ATAxx9x
Version
Type
ROM
E2PROM Peripheral
Packages
Flash device
ATAM893
4-Kbyte EEPROM
64 byte
SSO20
Production
ATAR092
4-Kbyte mask ROM
–
SSO20
Production
ATAR892
4-Kbyte mask ROM
64 byte
SSO20
MARC4 Architecture
General Description
The MARC4 microcontroller consists of an advanced stack-based, 4-bit CPU core and
on-chip peripherals. The CPU is based on the HARVARD architecture with physically
separate program memory (ROM) and data memory (RAM). Three independent buses,
the instruction bus, the memory bus and the I/O bus, are used for parallel communication between ROM, RAM and peripherals. This enhances program execution speed by
allowing both instruction prefetching, and a simultaneous communication to the on-chip
peripheral circuitry. The extremely powerful integrated interrupt controller with associated eight prioritized interrupt levels supports fast and efficient processing of hardware
events. The MARC4 is designed for the high-level programming language qFORTH.
The core includes both an expression and a return stack. This architecture enables
high-level language programming without any loss of efficiency or code density.
Figure 3. MARC4 Core
MARC4 CORE
Reset
Program
memory
Reset
Clock
PC
Instruction
bus
X
Y
SP
RP
Memory bus
Instruction
decoder
System
clock
Sleep
RAM
256 x 4-bit
TOS
CCR
Interrupt
controller
ALU
I/O bus
On-chip peripheral modules
3
4594C–4BMCU–12/04
Components of MARC4
Core
The core contains ROM, RAM, ALU, a program counter, RAM address registers, an
instruction decoder and an interrupt controller. The following sections describe each
functional block in more detail.
ROM
The program memory (ROM) is mask programmed with the customer application program during the fabrication of the microcontroller. The 4 Kbytes ROM size is addressed
by a 12-bit wide program counter. An additional 1 Kbyte of ROM exists which is
reserved for quality control self-test software. The lowest user ROM address segment is
taken up by a 512-byte zero page which contains predefined start addresses for interrupt service routines and special subroutines accessible with single byte instructions
(SCALL).
The corresponding memory map is shown in Figure 4. Look-up tables of constants can
also be held in ROM and are accessed via the MARC4’s built-in table instruction.
Figure 4. ROM Map
ROM
(4 K x 8 bit)
7FFh
1FFh
Zero page
000h
SCALL addresses
1F8h
1F0h
1E8h
1E0h
FFFh
020h
018h
010h
008h
000h
Zero
page
1E0h
INT7
1C0h
INT6
180h
INT5
140h
INT4
100h
INT3
0C0h
INT2
080h
INT1
040h
INT0
008h
000h
$AUTOSLEEP
$RESET
RAM
The ATAR092-D contain 256 x 4-bit wide static random access memory (RAM). It is
used for the expression stack, the return stack and data memory for variables and
arrays. The RAM is addressed by any of the four 8-bit wide RAM address registers SP,
RP, X and Y.
Expression Stack
The 4-bit wide expression stack is addressed with the expression stack pointer (SP). All
arithmetic, I/O and memory reference operations take their operands from, and return
their results to the expression stack. The MARC4 performs the operations with the top of
stack items (TOS and TOS-1). The TOS register contains the top element of the expression stack and works in the same way as an accumulator. This stack is also used for
passing parameters between subroutines and as a scratch pad area for temporary storage of data.
Return Stack
The 12-bit wide return stack is addressed by the return stack pointer (RP). It is used for
storing return addresses of subroutines, interrupt routines and for keeping loop index
counts. The return stack can also be used as a temporary storage area.
The MARC4 instruction set supports the exchange of data between the top elements of
the expression stack and the return stack. The two stacks within the RAM have a user
definable location and maximum depth.
4
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 5. RAM Map
RAM
(256 x 4-bit)
Autosleep
RAM Address Register:
FCh
Expression stack
3
0
TOS
TOS-1
TOS-2
FFh
Global
variables
X
SP
4-bit
Y
SP
Expression
stack
TOS-1
Return stack
11
0
RP
Return
stack
RP
Global
v
variables
07h
03h
04h
00h
12-bit
Registers
The MARC4 controller has seven programmable registers and one condition code register. They are shown in the following programming model (Figure 6).
Program Counter (PC)
The program counter is a 12-bit register which contains the address of the next instruction to be fetched from ROM. Instructions currently being executed are decoded in the
instruction decoder to determine the internal micro-operations. For linear code (no calls
or branches) the program counter is incremented with every instruction cycle. If a
branch-, call-, return-instruction or an interrupt is executed, the program counter is
loaded with a new address. The program counter is also used with the table instruction
to fetch 8-bit wide ROM constants.
Figure 6. Programming Model
11
0
PC
Program counter
0
7
0
RP
0
Return stack pointer
0
7
SP
Expression stack pointer
0
7
X
RAM address register (X)
7
0
Y
RAM address register (Y)
3
0
Top of stack register
TOS
CCR
3
C
--
B
0
I
Condition code register
Interrupt enable
Branch
Reserved
Carry/borrow
5
4594C–4BMCU–12/04
RAM Address Registers
The RAM is addressed with four 8-bit wide RAM address registers: SP, RP, X and Y.
These registers allow access to any of the 256 RAM nibbles.
Expression Stack Pointer (SP)
The stack pointer contains the address of the next-to-top 4-bit item (TOS-1) of the
expression stack. The pointer is automatically pre-incremented if a nibble is moved onto
the stack or post-decremented if a nibble is removed from the stack. Every post-decrement operation moves the item (TOS-1) to the TOS register before the SP is
decremented. After a reset the stack pointer has to be initialized with >SP S0 to allocate
the start address of the expression stack area.
Return Stack Pointer (RP)
The return stack pointer points to the top element of the 12-bit wide return stack. The
pointer automatically pre-increments if an element is moved onto the stack, or it postdecrements if an element is removed from the stack. The return stack pointer increments and decrements in steps of 4. This means that every time a 12-bit element is
stacked, a 4-bit RAM location is left unwritten. This location is used by the qFORTH
compiler to allocate 4-bit variables. After a reset the return stack pointer has to be initialized via >RP FCh.
RAM Address Registers
(X and Y)
The X and Y registers are used to address any 4-bit item in RAM. A fetch operation
moves the addressed nibble onto the TOS. A store operation moves the TOS to the
addressed RAM location. By using either the pre-increment or post-decrement addressing mode, arrays located in RAM can be compared, filled or moved
Top of Stack (TOS)
The top of stack register is the accumulator of the MARC4. All arithmetic/logic, memory
reference and I/O operations use this register. The TOS register receives data from the
ALU, ROM, RAM or I/O bus.
Condition Code Register (CCR)
The 4-bit wide condition code register contains the branch, the carry and the interrupt
enable flag. These bits indicate the current state of the CPU. The CCR flags are set or
reset by ALU operations. The instructions SET_BCF, TOG_BF, CCR! and DI allow
direct manipulation of the condition code register.
Carry/Borrow (C)
The carry/borrow flag indicates that the borrowing or carrying out of Arithmetic Logic
Unit (ALU) occurred during the last arithmetic operation. During shift and rotate operations, this bit is used as a fifth bit. Boolean operations have no affect on the C-flag.
Branch (B)
The branch flag controls conditional program branching. Should the branch flag have
been set by a previous instruction, a conditional branch will cause a jump. This flag is
affected by arithmetic, logic, shift, and rotate operations.
Interrupt Enable (I)
The interrupt enable flag globally enables or disables the triggering of all interrupt routines with the exception of the non-maskable reset. After a reset or while executing the
DI instruction, the interrupt enable flag is reset, thus disabling all interrupts. The core will
not accept any further interrupt requests until the interrupt enable flag has been set
again by either executing an EI or SLEEP instruction.
ALU
The 4-bit ALU performs all the arithmetic, logical, shift and rotate operations with the top
two elements of the expression stack (TOS and TOS-1) and returns the result to the
TOS. The ALU operations affect the carry/borrow and branch flag in the condition code
register (CCR).
6
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 7. ALU Zero-address Operations
RAM
SP
TOS-1
TOS
TOS-2
TOS-3
TOS-4
ALU
CCR
I/O Bus
The I/O ports and the registers of the peripheral modules are I/O mapped. All communication between the core and the on-chip peripherals takes place via the I/O bus and the
associated I/O control. With the MARC4 IN and OUT instructions the I/O bus allows a
direct read or write access to one of the 16 primary I/O addresses. More about the I/O
access to the on-chip peripherals is described in the section “Peripheral Modules”. The
I/O bus is internal and is not accessible by the customer on the final microcontroller
device, but it is used as the interface for the MARC4 emulation also see section
“Emulation”).
Instruction Set
The MARC4 instruction set is optimized for the high level programming language
qFORTH. Many MARC4 instructions are qFORTH words. This enables the compiler to
generate a fast and compact program code. The CPU has an instruction pipeline allowing the controller to prefetch an instruction from ROM at the same time as the present
instruction is being executed. The MARC4 is a zero-address machine, the instructions
contain only the operation to be performed and no source or destination address fields.
The operations are implicitly performed on the data placed on the stack. There are one
and two byte instructions which are executed within 1 to 4 machine cycles. A MARC4
machine cycle is made up of two system clock cycles (SYSCL). Most of the instructions
are only one byte long and are executed in a single machine cycle. For more information
refer to the “MARC4 Programmer’s Guide”.
Interrupt Structure
The MARC4 can handle interrupts with eight different priority levels. They can be generated from the internal and external interrupt sources or by a software interrupt from the
CPU itself. Each interrupt level has a hard-wired priority and an associated vector for the
service routine in the ROM (see Table 3 on page 9). The programmer can postpone the
processing of interrupts by resetting the interrupt enable flag (I) in the CCR. An interrupt
occurrence will still be registered, but the interrupt routine only started after the I flag is
set. All interrupts can be masked, and the priority individually software configured by
programming the appropriate control register of the interrupting module (see section
“Peripheral Modules”).
Interrupt Processing
For processing the eight interrupt levels, the MARC4 includes an interrupt controller with
two 8-bit wide interrupt pending and interrupt active registers. The interrupt controller
samples all interrupt requests during every non-I/O instruction cycle and latches these in
the interrupt pending register. If no higher priority interrupt is present in the interrupt
active register, it signals the CPU to interrupt the current program execution. If the interrupt enable bit is set, the processor enters an interrupt acknowledge cycle. During this
cycle a short call (SCALL) instruction to the service routine is executed and the current
PC is saved on the return stack.
7
4594C–4BMCU–12/04
An interrupt service routine is completed with the RTI instruction. This instruction resets
the corresponding bits in the interrupt pending/active register and fetches the return
address from the return stack to the program counter. When the interrupt enable flag is
reset (triggering of interrupt routines are disabled), the execution of new interrupt service routines is inhibited but not the logging of the interrupt requests in the interrupt
pending register. The execution of the interrupt is delayed until the interrupt enable flag
is set again. Note that interrupts are only lost if an interrupt request occurs while the corresponding bit in the pending register is still set (i.e., the interrupt service routine is not
yet finished).
It should also be noted that automatic stacking of the RBR is not carried out by the hardware and so if ROM banking is used, the RBR must be stacked on the expression stack
by the application program and restored before the RTI. After a master reset (power-on,
brown-out or watchdog reset), the interrupt enable flag and the interrupt pending and
interrupt active register are all reset.
Interrupt Latency
The interrupt latency is the time from the occurrence of the interrupt to the interrupt service routine being activated. In MARC4 this is extremely short (taking between 3 to
5 machine cycles depending on the state of the core).
Figure 8. Interrupt Handling
INT7
7
INT7 active
INT5
6
Priority Level
5
4
RTI
INT5 active
RTI
INT3
INT2
3
INT3 active
RTI
2
INT2 pending
1
SWI0
INT2 active
RTI
0
INT0 pending
INT0 active
RTI
Main /
Autosleep
Main /
Autosleep
Time
8
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Table 2. Interrupt Priority Table
Interrupt
Priority
ROM Address
Interrupt Opcode
Function
INT0
Lowest
040h
C8h (SCALL 040h)
Software interrupt (SWI0)
INT1
|
080h
D0h (SCALL 080h)
External hardware interrupt, any edge at BP52 or
BP53
INT2
|
0C0h
D8h (SCALL 0C0h)
Timer 1 interrupt
INT3
|
100h
E8h (SCALL 100h)
SSI interrupt or external hardware interrupt at BP40 or
BP43
INT4
|
140h
E8h (SCALL 140h)
Timer 2 interrupt
INT5
|
180h
F0h (SCALL 180h)
Timer 3 interrupt
INT6
↓
1C0h
F8h (SCALL 1C0h)
External hardware interrupt, at any edge at BP50 or
BP51
INT7
Highest
1E0h
FCh (SCALL 1E0h)
Voltage Monitor (VM) interrupt
Table 3. Hardware Interrupts
Interrupt Mask
Interrupt
Register
Bit
Interrupt Source
INT1
P5CR
P52M1, P52M2
P53M1, P53M2
Any edge at BP52
any edge at BP53
INT2
T1M
T1IM
Timer 1
INT3
SISC
SIM
SSI buffer full/empty or BP40/BP43 interrupt
INT4
T2CM
T2IM
Timer 2 compare match/overflow
INT5
T3CM1
T3CM2
T3C
T3IM1
T3IM2
T3EIM
Timer 3 compare register 1 match
Timer 3 compare register 2 match
Timer 3 edge event occurs (T3I)
INT6
P5CR
P50M1, P50M2
P51M1, P51M2
INT7
VCM
VIM
Any edge at BP50,
any edge at BP51
External/internal voltage monitoring
Software Interrupts
The programmer can generate interrupts by using the software interrupt instruction
(SWI) which is supported in qFORTH by predefined macros named SWI0...SWI7. The
software triggered interrupt operates exactly like any hardware triggered interrupt. The
SWI instruction takes the top two elements from the expression stack and writes the corresponding bits via the I/O bus to the interrupt pending register. Therefore, by using the
SWI instruction, interrupts can be re-prioritized or lower priority processes scheduled for
later execution.
Hardware Interrupts
In the ATAR092-D, there are eleven hardware interrupt sources with seven different levels. Each source can be masked individually by mask bits in the corresponding control
registers. An overview of the possible hardware configurations is shown in Table 3.
Master Reset
The master reset forces the CPU into a well-defined condition. It is unmaskable and is
activated independently from the current program state. It can be triggered by either initial supply power-up, a short collapse of the power supply, brown-out detection circuitry,
watchdog time-out, or an external input clock supervisor stage (see Figure 9 on page
10).
9
4594C–4BMCU–12/04
A master reset activation will reset the interrupt enable flag, the interrupt pending register and the interrupt active register. During the power-on reset phase the I/O bus control
signals are set to reset mode thereby initializing all on-chip peripherals. All bi-directional
ports are set to input mode.
Attention: During any reset phase, the BP20/NTE input is driven towards VDD by an
additional internal strong pull-up transistor. This pin must not be pulled down to VSS during reset by any external circuitry representing a resistor of less than 150 kΩ.
Releasing the reset results in a short call instruction (opcode C1h) to the ROM address
008h. This activates the initialization routine $RESET which in turn has to initialize all
necessary RAM variables, stack pointers and peripheral configuration registers (see
Table 10 on page 21).
Figure 9. Reset Configuration
VDD
Pull-up
CL
NRST
Reset
timer
res
Internal
reset
CL = SYSCL/4
Power-on
reset
Brown-out
detection
Power-on Reset and
Brown-out Detection
VDD
VSS
VDD
VSS
Watchres
dog
CWD
Ext. clock
supervisor
ExIn
The ATAR092-D has a fully integrated power-on reset and brown-out detection circuitry.
For reset generation no external components are needed.
These circuits ensure that the core is held in the reset state until the minimum operating
supply voltage has been reached. A reset condition will also be generated should the
supply voltage drop momentarily below the minimum operating level except when a
power down mode is activated (the core is in SLEEP mode and the peripheral clock is
stopped). In this power-down mode the brown-out detection is disabled. Two values for
the brown-out voltage threshold are programmable via the BOT bit in the SC register.
A power-on reset pulse is generated by a VDD rise across the default BOT voltage level
(1.7 V). A brown-out reset pulse is generated when VDD falls below the brown-out voltage threshold. Two values for the brown-out voltage threshold are programmable via
the BOT bit in the SC register. When the controller runs in the upper supply voltage
range with a high system clock frequency, the high threshold must be used. When it
runs with a lower system clock frequency, the low threshold and a wider supply voltage
range may be chosen. For further details, see the electrical specification and the SC
register description for BOT programming.
10
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 10. Brown-out Detection
VDD
2.0 V
1.7 V
td
CPU
Reset
BOT = 1
td
CPU
Reset
t
td
BOT = 0
td = 1.5 ms (typically)
BOT = 1, low brown-out voltage threshold 1.7 V (is reset value).
BOT = 0, high brown-out voltage threshold 2.0 V.
Watchdog Reset
The watchdog’s function can be enabled at the WDC register and triggers a reset with
every watchdog counter overflow. To suppress the watchdog reset, the watchdog
counter must be regularly reset by reading the watchdog register address (CWD). The
CPU reacts in exactly the same manner as a reset stimulus from any of the above
sources.
External Clock Supervisor
The external input clock supervisor function can be enabled if the external input clock is
selected within the CM and SC registers of the clock module. The CPU reacts in exactly
the same manner as a reset stimulus from any of the above sources.
Voltage Monitor
The voltage monitor consists of a comparator with internal voltage reference. It is used
to supervise the supply voltage or an external voltage at the VMI pin. The comparator for
the supply voltage has three internal programmable thresholds one lower threshold
(2.2 V), one middle threshold (2.6 V). and one higher threshold (3.0 V). For external
voltages at the VMI pin, the comparator threshold is set to VBG = 1.3 V. The VMS bit
indicates if the supervised voltage is below (VMS = 0) or above (VMS = 1) this threshold. An interrupt can be generated when the VMS bit is set or reset to detect a rising or
falling slope. A voltage monitor interrupt (INT7) is enabled when the interrupt mask bit
(VIM) is reset in the VMC register.
11
4594C–4BMCU–12/04
Figure 11. Voltage Monitor
VDD
Voltage monitor
INT7
OUT
BP41/
VMI
IN
VMC
VM2
VM1 VM0
-
VMST
-
VIM
res VMS
Voltage Monitor
Control/Status Register
Primary register address: ’F’hex
Bit 3
Bit 2
Bit 1
Bit 0
VMC: Write
VM2
VM1
VM0
VIM
Reset value: 1111b
VMST: Read
–
–
reserved
VMS
Reset value: xx11b
VM2: Voltage monitor Mode bit 2
VM1: Voltage monitor Mode bit 1
VM0: Voltage monitor Mode bit 0
Table 4. Voltage Monitor Modes
12
VM2
VM1
VM0
1
1
1
Disable voltage monitor
Function
1
1
0
External (VIM input), internal reference threshold (1.3 V),
interrupt with negative slope
1
0
1
Not allowed
1
0
0
External (VMI input), internal reference threshold (1.3 V),
interrupt with positive slope
0
1
1
Internal (supply voltage), high threshold (3.0 V), interrupt
with negative slope
0
1
0
Internal (supply voltage), middle threshold (2.6 V), interrupt
with negative slope
0
0
1
Internal (supply voltage), low threshold (2.2 V), interrupt with
negative slope
0
0
0
Not allowed
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
VIM
Voltage Interrupt Mask bit
VIM = 0, voltage monitor interrupt is enabled
VIM = 1, voltage monitor interrupt is disabled
VMS
Voltage Monitor Status bit
VMS = 0, the voltage at the comparator input is below VRef
VMS = 1, the voltage at the comparator input is above VRef
Figure 12. Internal Supply Voltage Supervisor
VMS = 1
VDD
Low threshold
Middle threshold
High threshold
3.0 V
2.6 V
2.2 V
Low threshold
Middle threshold
High threshold
VMS = 0
Figure 13. External Input Voltage Supervisor
Internal reference level
VMI
Negative slope
Interrupt positive slope
VMS = 1
VMS = 1
VMS = 0
VMS = 0
1.3 V
Positive slope
Interrupt negative slope
t
Clock Generation
Clock Module
The ATAR092-D contains a clock module with 4 different internal oscillator types: two
RC-oscillators, one 4-MHz crystal oscillator and one 32-kHz crystal oscillator. The pins
OSC1 and OSC2 are the interface to connect a crystal either to the 4-MHz, or to the
32-kHz crystal oscillator. OSC1 can be used as input for external clocks or to connect an
external trimming resistor for the RC-oscillator 2. All necessary circuitry except the crystal and the trimming resistor is integrated on-chip. One of these oscillator types or an
external input clock can be selected to generate the system clock (SYSCL).
In applications that do not require exact timing, it is possible to use the fully integrated
RC-oscillator 1 without any external components. The RC-oscillator 1 center frequency
tolerance is better than ±50%. The RC-oscillator 2 is a trimmable oscillator whereby the
oscillator frequency can be trimmed with an external resistor attached between OSC1
and VDD. In this configuration, the RC-oscillator 2 frequency can be maintained in a stable state with a tolerance of ±15% over the full operating temperature and voltage
range.
13
4594C–4BMCU–12/04
The clock module is programmable via software with the clock management register
(CM) and the system configuration register (SC). The required oscillator configuration
can be selected with the OS1 bit and the OS0 bit in the SC register. A programmable
4-bit divider stage allows the adjustment of the system clock speed. A special feature of
the clock management is that an external oscillator may be used and switched on and
off via a port pin for the power-down mode. Before the external clock is switched off, the
internal RC-oscillator 1 must be selected with the CCS bit and then the SLEEP mode
may be activated. In this state an interrupt can wake up the controller with the RC-oscillator, and the external oscillator can be activated and selected by software. A
synchronization stage avoids too short clock periods if the clock source or the clock
speed is changed. If an external input clock is selected, a supervisor circuit monitors the
external input and generates a hardware reset if the external clock source fails or drops
below 500 kHz for more than 1 ms.
Figure 14. Clock Module
RC
oscillator 1
Ext. clock
OSC1
Oscin
SYSCL
ExOut
Stop
ExIn
*
RCOut1
Control
RC oscillator2
Stop
RCOut2
Stop
RTrim
IN1
Cin
/2
/2
4-MHz oscillator
Oscin
Oscout
/2
/2
IN2
Divider
4Out
Stop
32-kHz oscillator
OSC2
Oscout
*
Oscin
Oscout
32Out
Osc-Stop
CM:
Sleep
WDL
Cin/16
NSTOP
CCS
CSS1
SUBCL
CSS0
32 kHz
*
mask option
SC
BOT
---
OS1
OS0
Table 5. Clock Modes
Clock Source for SYSCL
Mode
OS1
OS0
CCS = 1
CCS = 0
Clock Source
for SUBCL
1
1
1
RC-oscillator 1 (internal)
External input clock
Cin/16
2
0
1
RC-oscillator 1 (internal)
RC-oscillator 2 with
external trimming resistor
Cin/16
3
1
0
RC-oscillator 1 (internal)
4-MHz oscillator
Cin/16
4
0
0
RC-oscillator 1 (internal)
32-kHz oscillator
32 kHz
The clock module generates two output clocks. One is the system clock (SYSCL) and
the other the periphery (SUBCL). The SYSCL can supply the core and the peripherals
and the SUBCL can supply only the peripherals with clocks. The modes for clock
sources are programmable with the OS1 bit and OS0 bit in the SC register and the CCS
bit in the CM register.
14
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Oscillator Circuits and
External Clock Input Stage
The ATAR092-D series consists of four different internal oscillators: two RC-oscillators,
one 4-MHz crystal oscillator, one 32-kHz crystal oscillator and one external clock input
stage.
RC-oscillator 1 Fully Integrated
For timing insensitive applications, it is possible to use the fully integrated RC
oscillator 1. It operates without any external components and saves additional costs.
The RC-oscillator 1 center frequency tolerance is better than ±50% over the full temperature and voltage range. The basic center frequency of the RC-oscillator 1 is
fO ≈ 3.8 MHz. The RC oscillator 1 is selected by default after power-on reset.
Figure 15. RC-oscillator 1
RC-oscillator 1
RcOut1
RcOut1
Osc-Stop
Stop
Control
External Input Clock
The OSC1 or OSC2 (mask option) can be driven by an external clock source provided it
meets the specified duty cycle, rise and fall times and input levels. Additionally the external clock stage contains a supervisory circuit for the input clock. The supervisor function
is controlled via OS1, OS0 bit in the SC register and the CCS bit in the CM register. If
the external input clock is missing for more than 1 ms and CCS = 0 is set in the CM register, the supervisory circuit generates a hardware reset.
Figure 16. External Input Clock
Ext. input clock
Ext.
Clock
ExOut
OSC1
ExIn
Stop
or
RcOut1
Osc-Stop
CCS
Ext.
Clock
OSC2
Clock monitor
Res
Table 6. Supervisor Function Control Bits
OS1
OS0
CCS
Supervisor Reset Output (Res)
1
1
0
Enable
1
1
1
Disable
x
0
x
Disable
15
4594C–4BMCU–12/04
RC-oscillator 2 with External
Trimming Resistor
The RC-oscillator 2 is a high resolution trimmable oscillator whereby the oscillator frequency can be trimmed with an external resistor between OSC1 and V DD. In this
configuration, the RC-oscillator 2 frequency can be maintained in a stable state with a
tolerance of ±10% over the full operating temperature range and a voltage range VDD
from 2.5 V to 6.0 V.
For example: An output frequency at the RC-oscillator 2 of 2 MHz can be obtained by
connecting a resistor Rext = 360 kΩ (see Figure 17).
Figure 17. RC-oscillator 2
VDD
RC-oscillator 2
Rext
OSC1
RcOut2
RcOut2
RTrim
Osc-Stop
Stop
OSC2
4-MHz Oscillator
The ATAR092-D 4-MHz oscillator option needs a crystal or ceramic resonator connected to the OSC1 and OSC2 pins to establish oscillation.
All the necessary oscillator circuitry is integrated, except the actual crystal, resonator, C3
and C4.
Figure 18. 4-MHz Crystal Oscillator
OSC1
Oscin
4Out
*
XTAL
4 MHz
C1
4-MHz
oscillator
Oscout
OSC2
Stop
4Out
Osc-Stop
*
*
C2
mask option
Note:
16
Both, the 4-MHz and the 32-kHz crystal oscillator, use an integrated 14 stage divider circuit to stabilize oscillation before the oscillator output is used as system clock. This
results in an additional delay of about 4 ms for the 4-MHz crystal and about 500 ms for
the 32-kHz crystal.
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 19. Ceramic Resonator
C3
OSC1
Oscin
4Out
*
Cer.
Res
4-MHz
oscillator
C1
Oscout
OSC2
C4
Stop
4Out
Osc-Stop
*
*
C2
mask option
Note:
32-kHz Oscillator
Both, the 4-MHz and the 32-kHz crystal oscillator, use an integrated 14 stage divider circuit to stabilize oscillation before the oscillator output is used as system clock. This
results in an additional delay of about 4 ms for the 4-MHz crystal and about 500 ms for
the 32-kHz crystal.
Some applications require long-term time keeping or low resolution timing. In this case,
an on-chip, low power 32-kHz crystal oscillator can be used to generate both the
SUBCL and the SYSCL. In this mode, power consumption is greatly reduced. The
32-kHz crystal oscillator cannot be stopped while the power-down mode is in operation.
Figure 20. 32-kHz Crystal Oscillator
OSC1
Oscin
32Out
*
XTAL
32 kHz
C1
32Out
32-kHz
oscillator
Oscout
OSC2
*
*
C2
mask option
Note:
Clock Management
Both, the 4-MHz and the 32-kHz crystal oscillator, use an integrated 14 stage divider circuit to stabilize oscillation before the oscillator output is used as system clock. This
results in an additional delay of about 4 ms for the 4-MHz crystal and about 500 ms for
the 32-kHz crystal.
The clock management register controls the system clock divider and synchronization
stage. Writing to this register triggers the synchronization cycle.
17
4594C–4BMCU–12/04
Clock Management Register
(CM)
Auxiliary register address: ’3’hex
CM
Bit 3
Bit 2
Bit 1
Bit 0
NSTOP
CCS
CSS1
CSS0
Reset value: 1111b
NSTOP
Not STOP peripheral clock
NSTOP = 0, stops the peripheral clock while the core is in SLEEP mode
NSTOP = 1, enables the peripheral clock while the core is in SLEEP mode
CCS
Core Clock Select
CCS = 1, the internal RC-oscillator 1 generates SYSCL
CCS = 0, the 4-MHz crystal oscillator, the 32-kHz crystal oscillator, an external
clock source or the RC-oscillator 2 with the external resistor at OSC1
generates SYSCL depending on the setting of OS0 and OS1 in the
system configuration register
CSS1
Core Speed Select 1
CSS0
Core Speed Select 0
Table 7. Core Speed Select
CSS1
CSS0
Divider
0
0
16
–
1
1
8
Reset value
1
0
4
–
0
1
2
–
System Configuration Register
(SC)
Note
Primary register address: ’3’hex
Bit 3
Bit 2
Bit 1
Bit 0
SC: write
BOT
–
OS1
OS0
BOT
Brown-Out Threshold
BOT = 1, low brown-out voltage threshold (1.7 V)
BOT = 0, high brown-out voltage threshold (2.0 V)
OS1
Oscillator Select 1
OS0
Oscillator Select 0
Reset value: 1x11b
Table 8. Oscillator Select
Mode
OS1
OS0
Input for SUBCL
1
1
1
Cin/16
RC-oscillator 1 and external input clock
RC-oscillator 1 and RC-oscillator 2
2
0
1
Cin/16
3
1
0
Cin/16
RC-oscillator 1 and 4-MHz crystal oscillator
4
0
0
32 kHz
RC-oscillator 1 and 32-kHz crystal oscillator
Note:
18
Selected Oscillators
If the bit CCS = 0 in the CM-register the RC-oscillator 1 always stops.
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Power-down Modes
The sleep mode is a shut-down condition which is used to reduce the average system
power consumption in applications where the microcontroller is not fully utilized. In this
mode, the system clock is stopped. The sleep mode is entered via the SLEEP instruction. This instruction sets the interrupt enable bit (I) in the condition code register to
enable all interrupts and stops the core. During the sleep mode the peripheral modules
remain active and are able to generate interrupts. The microcontroller exits the sleep
mode by carrying out any interrupt or a reset.
The sleep mode can only be maintained when none of the interrupt pending or active
register bits are set. The application of the $AUTOSLEEP routine ensures the correct
function of the sleep mode. For standard applications use the $AUTOSLEEP routine to
enter the power-down mode. Using the SLEEP instruction instead of the $AUTOSLEEP
following an I/O instruction requires insertion of 3 non I/O instruction cycles (for example
NOP NOP NOP) between the IN or OUT command and the SLEEP command.
The total power consumption is directly proportional to the active time of the microcontroller. For a rough estimation of the expected average system current consumption, the
following formula should be used:
Itotal (VDD,fsyscl) = ISleep + (IDD × tactive/ttotal)
IDD depends on VDD and fsyscl
The ATAR092-D has various power-down modes. During the sleep mode the clock for
the MARC4 core is stopped. With the NSTOP bit in the clock management register (CM)
it is programmable if the clock for the on-chip peripherals is active or stopped during the
sleep mode. If the clock for the core and the peripherals is stopped the selected oscillator is switched off. An exception is the 32-kHz oscillator, if it is selected it runs
continuously independent of the NSTOP bit. If the oscillator is stopped or the 32-kHz
oscillator is selected, power consumption is extremely low.
Table 9. Power-down Modes
Mode
CPU
Core
OscStop(1)
Brown-out
Function
RC-Oscillator 1
RC-Oscillator 2
4-MHz Oscillator
32-kHz
Oscillator
External
Input Clock
Active
Run
No
Active
Run
Run
Yes
Power-down
SLEEP
No
Active
Run
Run
Yes
SLEEP
SLEEP
Yes
Stop
Stop
Run
Stop
Note:
1.
Osc-Stop = SLEEP and NSTOP and WDL
19
4594C–4BMCU–12/04
Peripheral Modules
Addressing Peripherals
Accessing the peripheral modules takes place via the I/O bus (see Figure 21). The IN or
OUT instructions allow direct addressing of up to 16 I/O modules. A dual register
addressing scheme has been adopted to enable direct addressing of the primary register. To address the auxiliary register, the access must be switched with an auxiliary
switching module. Thus a single IN (or OUT) to the module address will read (or write
into) the module primary register. Accessing the auxiliary register is performed with the
same instruction preceded by writing the module address into the auxiliary switching
module. Byte wide registers are accessed by multiple IN (or OUT) instructions. For more
complex peripheral modules, with a larger number of registers, extended addressing is
used. In this case, a bank of up to 16 subport registers are indirectly addressed with the
subport address. The first OUT -instruction writes the subport address to the sub
address register, the second IN or OUT -instruction reads data from or writes data to the
addressed subport.
Figure 21. Example of I/O Addressing
Module M1
Module ASW
(Address Pointer)
Subaddress Reg.
Module M2
Bank of
Primary Regs.
Auxiliary Switch
Module
Subport FH
1
Module M3
Aux. Reg.
5
Subport EH
Subport 1
Primary Reg.
Primary Reg.
Primary Reg.
Subport 0
2
3
6
4
I/O bus
to other modules
Indirect Subport Access
Dual Register Access
(Primary Register Write)
(Subport Register Write)
1
Addr. (SPort) Addr. (M1) OUT
2
SPort_Data
Addr. (M1)
Example of
qFORTH
Program
Code
Addr. (SPort) Addr. (M1) OUT
2
Prim._Data Addr. (M2) OUT
4
Addr. (M2) Addr. (ASW) OUT
5
Aux._Data Addr. (M2) OUT
Prim._Data Addr. (M3) OUT
(Primary Register Read)
6
Addr. (M3) IN
(Primary Register Read)
3
1
Addr. (SPort) Addr. (M1) OUT
2
SPort_Data (lo) Addr. (M1)
Addr. (M2) IN
(Auxiliary Register Read )
SPort_Data (hi) Addr. (M1)
OUT
OUT
4
5
(Subport Register Read Byte)
1
6
(Auxiliary Register Write)
Addr. (M1) IN
(Subport Register Write Byte)
2
(Primary Register Write)
3
OUT
(Subport Register Read)
1
Single Register Access
Addr. (SPort) Addr. (M1) OUT
Addr. (M2) Addr. (ASW) OUT
Addr. (M2) IN
(Auxiliary Register Write Byte)
4
Addr. (M2) Addr. (ASW) OUT
2
Addr. (M1) IN (hi)
5
Aux._Data (lo) Addr. (M2)
OUT
2
Addr. (M1) IN (lo)
5
Aux._Data (hi) Addr. (M2)
OUT
Addr. (ASW) = Auxililiary Switch Module Address
Aux._Data (hi) = Data to be written into Auxiliary Register (high nibble)
Addr. (Mx) = Module Mx Address
SPort_Data (lo) = Data to be written into Subport (low nibble)
Addr. (SPort) = Subport Address
Prim._Data = Data to be written into Primary Register
Aux._Data = Data to be written into Auxiliary Register
SPort_Data (hi) = Data to be written into Subport (high nibble)
(lo) = SPort_Data (low nibble)
(hi) = SPort_Data (high nibble)
Aux._Data (lo) = Data to be written into Auxiliary Register (low nibble)
20
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Table 10. Peripheral Addresses
Port Address
Module
Type
See
Page
Write/Read
1
P1DAT
W/R
1xx1b
Port 1 - data register/input data
M3
22
2
P2DAT
W/R
1111b
Port 2 - data register/pin data
M2
24
P2CR
W
1111b
Port 2 - control register
SC
W
1x11b
System configuration register
M3
18
CWD
R
xxxxb
Watchdog reset
M3
11
Auxiliary
3
Auxiliary
4
CM
W
1111b
Clock management register
M2
18
W/R
1111b
Port 4 - data register/pin data
M2
27
P4CR
W
1111 1111b
Port 4 - control register (byte)
P5DAT
W/R
1111b
Port 5 - data register/pin data
M2
26
P5CR
W
1111 1111b
Port 5 - control register (byte)
P6DAT
W/R
1xx1b
Port 6 - data register/pin data
M2
28
P6CR
W
1111b
Port 6 - control register (byte)
T12SUB
W
–
Data to Timer 1/2 subport
M1
20
Auxiliary
6
Auxiliary
7
24
P4DAT
Auxiliary
5
Reset Value
Register Function
Name
27
26
28
Subport address
0
T2C
W
0000b
Timer 2 control register
M1
40
1
T2M1
W
1111b
Timer 2 mode register 1
M1
40
2
T2M2
W
1111b
Timer 2 mode register 2
M1
42
3
T2CM
W
0000b
Timer 2 compare mode register
M1
42
4
T2CO1
W
1111b
Timer 2 compare register 1
M1
43
5
T2CO2
W
1111 1111b
Timer 2 compare register 2 (byte)
M1
43
6
–
–
–
31
Reserved
7
–
–
–
8
T1C1
W
1111b
Timer 1 control register 1
M1
9
T1C2
W
x111b
Timer 1 control register 2
M1
32
A
WDC
W
1111b
Watchdog control register
M1
32
8
ASW
W
1111b
Auxiliary/switch register
ASW
20
9
STB
W
xxxx xxxxb
Serial transmit buffer (byte)
M2
67
SRB
R
xxxx xxxxb
Serial receive buffer (byte)
67
SIC1
W
1111b
Serial interface control register 1
65
SISC
W/R
1x11b
Serial interface status/control register
SIC2
W
1111b
Serial interface control register 2
T3SUB
W/R
–
B-F
Reserved
Auxiliary
A
Auxiliary
B
Reserved
Data to/from Timer 3 subport
M2
66
65
M1
20
Subport address
0
T3M
W
1111b
Timer 3 mode register
M1
52
1
T3CS
W
1111b
Timer 3 clock select register
M1
53
2
T3CM1
W
0000b
Timer 3 compare mode register 1
M1
54
3
T3CM2
W
0000b
Timer 3 compare mode register 2
M1
55
4
T3CO1
W
1111 1111b
Timer 3 compare register 1 (byte)
M1
55
4
T3CP
R
xxxx xxxxb
Timer 3 capture register (byte)
M1
56
5
T3CO2
W
1111 1111b
Timer 3 compare register 2 (byte)
M1
55
T3C
W
0000b
Timer 3 control register
M3
53
T3ST
R
x000b
Timer 3 status register
M3
53
6-F
C
–
Reserved
D
–
–
E
–
–
Reserved
F
VMC
W
1111b
Voltage monitor control register
M3
12
VMST
R
xx11b
Voltage monitor status register
M3
12
Reserved
21
4594C–4BMCU–12/04
Bi-directional Ports
With the exception of Port 1 and Port 6, all other ports (2, 4 and 5) are 4 bits wide. Port 1
and Port 6 have a data width of 2 bits (bit 0 and bit 3). All ports may be used for data
input or output. All ports are equipped with Schmitt trigger inputs and a variety of mask
options for open drain, open source, full complementary outputs, pull-up and pull-down
transistors. All Port Data Registers (PxDAT) are I/O mapped to the primary address register of the respective port address and the Port Control Register (PxCR), to the
corresponding auxiliary register.
There are five different directional ports available:
Bi-directional Port 1
Port 1
2-bit wide bi-directional ports with automatic full bus width direction switching
Port 2
4-bit wide bitwise-programmable I/O port
Port 5
4-bit wide bitwise-programmable bi-directional port with optional strong
pull-ups and programmable interrupt logic
Port 4
4-bit wide bitwise-programmable bi-directional port also provides the I/O
interface to Timer 2, SSI, voltage monitor input and external interrupt input
Port 6
2-bit wide bitwise-programmable bi-directional port also provides the I/O
interface to Timer 3 and the external interrupt input
In Port 1 the data direction register is not independently software programmable, the
direction of the complete port being switched automatically when an I/O instruction
occurs (see Figure 22 on page 23). The port is switched to output mode via an OUT
instruction and to input via an IN instruction. The data written to a port will be stored into
the output data latches and appears immediately at the port pin following the OUT
instruction. After RESET all output latches are set to 1 and the port is switched to input
mode. An IN instruction reads the condition of the associated pins.
Note:
Care must be taken when switching the bi-directional port from output to input. The
capacitive pin loading at this port in conjunction with the high resistance pull-ups may
cause the CPU to read the contents of the output data register rather than the external
input state. To avoid this, one of the following programming techniques should be used:
Use two IN-instructions and DROP the first data nibble. The first IN switches the port
from output to input and the DROP removes the first invalid nibble. The second IN reads
the valid pin state.
Use an OUT-instruction followed by an IN-instruction. Via the OUT-instruction, the capacitive load is charged or discharged depending on the optional pull-up/pull-down
configuration. Write a 1 for pins with pull-up resistors and a 0 for pins with pull-down
resistors.
22
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 22. Bi-directional Port 1
VDD
I/O Bus
(1)
(Data out)
D
(1)
Q
Static
pull-up
Switched
pull-up
BP1y
P1DATy
R
(1)
VDD
Reset
(Direction)
(1)
OUT
S
Q
(1)
IN
R
Mask options
Static
pull-down
Switched
pull-down
NQ
Master reset
Bi-directional Port 2
As all other bi-directional ports, this port includes a bitwise programmable Control Register (P2CR), which enables the individual programming of each port bit as input or
output. It also opens up the possibility of reading the pin condition when in output mode.
This is a useful feature for self testing and for serial bus applications.
Port 2, however, has an increased drive capability and an additional low resistance
pull-up/-down transistor mask option.
Note:
Care should be taken connecting external components to BP20/NTE. During any reset
phase, the BP20/NTE input is driven towards VDD by an additional internal strong pull-up
transistor. This pin must not be pulled down (active or passive) to VSS during reset by any
external circuitry representing a resistor of less than 150 kΩ. This prevents the circuit
from unintended switching to test mode enable through the application circuitry at Pin
BP20/NTE. Resistors less than 150 kΩ might lead to an undefined state of the internal
test logic thus disabling the application firmware.
To avoid any conflict with the optional internal pull-down transistors, BP20 handles the
pull-down options in a different way than all other ports. BP20 is the only port that
switches off the pull-down transistors during reset.
Figure 23. Bi-directional Port 2
VDD
Switched
pull-up
I/O Bus
(1)
(Data out)
(1)
Static
Pull-up
(1)
I/O Bus
D
Q
P2DATy
BP2y
S
VDD
(1)
Master reset
I/O Bus
(1)
D S Q
(1)
Static
Pull-down
P2CRy
(Direction)
(1)
Mask options
Switched
pull-down
23
4594C–4BMCU–12/04
Port 2 Data Register (P2DAT)
Primary register address: '2'hex
P2DAT
Bit 3
Bit 2
Bit 1
Bit 0
P2DAT3
P2DAT2
P2DAT1
P2DAT0
Reset value: 1111b
Bit 3 = MSB, Bit 0 = LSB
Port 2 Control Register (P2CR)
Auxiliary register address: '2'hex
P2CR
Bit 3
Bit 2
Bit 1
Bit 0
P2CR3
P2CR2
P2CR1
P2CR0
Reset value: 1111b
Value 1111b means all pins in input mode
Table 11. Port 2 Control Register
Bi-directional Port 5
Code
3210
Function
xxx1
BP20 in input mode
xxx0
BP20 in output mode
xx1x
BP21 in input mode
xx0x
BP21 in output mode
x1xx
BP22 in input mode
x0xx
BP22 in output mode
1xxx
BP23 in input mode
0xxx
BP23 in output mode
As all other bi-directional ports, this port includes a bitwise programmable Control Register (P5CR), which allows the individual programming of each port bit as input or
output. It also opens up the possibility of reading the pin condition when in output mode.
This is a useful feature for self-testing and for serial bus applications.
The port pins can also be used as external interrupt inputs (see Figure 24 on page 25
and Figure 25 on page 25). The interrupts (INT1 and INT6) can be masked or independently configured to trigger on either edge. The interrupt configuration and port direction
is controlled by the Port 5 Control Register (P5CR). An additional low resistance pullup/-down transistor mask option provides an internal bus pull-up for serial bus
applications.
The Port 5 Data Register (P5DAT) is I/O mapped to the primary address register of
address ‘5’h and the Port 5 Control Register (P5CR) to the corresponding auxiliary
register. The P5CR is a byte-wide register and is configured by writing first the low nibble and then the high nibble (see section “Addressing Peripherals”).
24
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 24. Bi-directional Port 5
Switched
pull-up
I/O Bus
VDD
(1)
(1)
Static
pull-up
VDD
(Data out)
(1)
I/O Bus
Q
D
P5DATy
BP5y
(1)
S
VDD
Master reset
(1)
(1)
IN enable
(1)
Static
Pull-down
Switched
pull-down
Mask options
Figure 25. Port 5 External Interrupts
INT1
INT6
Data in
Data in
BP52
BP51
Bidir. Port
Bidir. Port
IN_Enable
IN_Enable
I/O-bus
I/O-bus
Data in
Data in
BP53
BP50
Bidir. Port
Bidir. Port
IN_Enable
IN_Enable
Decoder
P5CR
Decoder
Decoder
Decoder
P53M2 P53M1 P52M2 P52M1 P51M2 P51M1 P50M2 P50M1
25
4594C–4BMCU–12/04
Port 5 Data Register (P5DAT)
Primary register address: '5'hex
P5DAT
Bit 3
Bit 2
Bit 1
Bit 0
P5DAT3
P5DAT2
P5DAT1
P5DAT0
Port 5 Control Register (P5CR)
Byte Write
Reset value: 1111b
Auxiliary register address: '5'hex
P5CR
First write
cycle
Second
write cycle
Bit 3
Bit 2
Bit 1
Bit 0
P51M2
P51M1
P50M2
P50M1
Bit 7
Bit 6
Bit 5
Bit 4
P53M2
P53M1
P52M2
P52M1
Reset value: 1111b
Reset value: 1111b
P5xM2, P5xM1 – Port 5x Interrupt Mode/Direction Code
Table 12. Port 5 Control Register
Auxiliary Address: '5'hex First Write Cycle
Second Write Cycle
Code
3210
Function
Code
3210
Function
xx11
BP50 in input mode – interrupt disabled
xx11
BP52 in input mode – interrupt disabled
xx01
BP50 in input mode – rising edge interrupt
xx01
BP52 in input mode – rising edge interrupt
xx10
BP50 in input mode – falling edge interrupt
xx10
BP52 in input mode – falling edge interrupt
xx00
BP50 in output mode – interrupt disabled
xx00
BP52 in output mode – interrupt disabled
11xx
BP51 in input mode – interrupt disabled
11xx
BP53 in input mode – interrupt disabled
01xx
BP51 in input mode – rising edge interrupt
01xx
BP53 in input mode – rising edge interrupt
10xx
BP51 in input mode – falling edge interrupt
10xx
BP53 in input mode – falling edge interrupt
00xx
BP51 in output mode – interrupt disabled
00xx
BP53 in output mode – interrupt disabled
26
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Bi-directional Port 4
The bi-directional Port 4 is a bitwise configurable I/O port and provides the external pins
for Timer 2, SSI and the voltage monitor input (VMI). As a normal port, it performs in
exactly the same way as bi-directional Port 2 (see Figure 26). Two additional multiplexes allow data and port direction control to be passed over to other internal modules
(Timer 2, VM or SSI). The I/O pins for SC and SD line have an additional mode to generate an SSI-interrupt.
All four Port 4 pins can be individually switched by the P4CR register. Figure 26 shows
the internal interfaces to bi-directional Port 4.
Figure 26. Bi-directional Port 4 and Port 6
VDD
I/O Bus
Intx
(1)
(1)
PxMRy
PIn
Static
pull-up
VDD
POut
Switched
pull-up
(1)
I/O Bus
D
Q
BPxy
PxDATy
S
VDD
(1)
Master reset
(Direction)
I/O Bus
D
S
(1)
(1)
Q
Static
pull-down
PxCRy
(1)
PDir
Switched
pull-down
Mask options
Port 4 Data Register (P4DAT)
Primary register address: '4'hex
P4DAT
Bit 3
Bit 2
Bit 1
Bit 0
P4DAT3
P4DAT2
P4DAT1
P4DAT0
Port 4 Control Register (P4CR)
Byte Write
Reset value: 1111b
Auxiliary register address: '4'hex
P4CR
First write
cycle
Bit 3
Bit 2
Bit 1
Bit 0
P41M2
P41M1
P40M2
P40M1
Bit 7
Bit 6
Bit 5
Bit 4
P43M1
P42M2
P42M1
Second
P43M2
write cycle
Reset value: 1111b
Reset value: 1111b
P4xM2, P4xM1 – Port 4x Interrupt Mode/Direction Code
27
4594C–4BMCU–12/04
Table 13. Port 4 Control Register
Auxiliary Address: '4'hex First Write Cycle
Second Write Cycle
Code
3210
Function
Code
3210
Function
xx11
BP40 in input mode
xx11
BP42 in input mode
xx10
BP40 in output mode
xx10
BP42 in output mode
xx01
BP40 enable alternate function (SC for SSI)
xx0x
BP42 enable alternate function (T2O for Timer 2)
xx00
BP40 enable alternate function
(falling edge interrupt input for INT3)
11xx
BP43 in input mode
11xx
BP41 in input mode
10xx
BP43 in output mode
10xx
BP41 in output mode
01xx
BP43 enable alternate function (SD for SSI)
01xx
BP41 enable alternate function
(VMI for voltage monitor input)
00xx
BP43 enable alternate function
(falling edge interrupt input for INT3)
00xx
BP41 enable alternate function
(T2I external clock input for Timer 2)
Bi-directional Port 6
–
–
The bi-directional Port 6 is a bitwise configurable I/O port and provides the external pins
for Timer 3. As a normal port, it performs in exactly the same way as bi-directional Port 6
(see Figure 26 on page 27). Two additional multiplexes allow data and port direction
control to be passed over to other internal modules (Timer 3). The I/O pin for T3I line
has an additional mode to generate a Timer 3 interrupt.
All two Port 6 pins can be individually switched by the P6CR register. Figure 26 on page
27 shows the internal interfaces to bi-directional Port 6.
Port 6 Data Register (P6DAT)
Primary register address: '6'hex
P6DAT
Bit 3
Bit 2
Bit 1
Bit 0
P6DAT3
–
–
P6DAT0
Bit 3
Bit 2
Bit 1
Bit 0
P63M2
P63M1
P60M2
P60M0
Reset value: 1xx1b
Port 6 Control Register (P6CR)
Primary register address: '6'hex
P6CR
Reset value: 1111b
P6xM2, P6xM1 - Port 6x Interrupt mode/direction code
Table 14. Port 6 Control Register
Auxiliary Address: ‘6’hex
28
Write Cycle
Code
3210
Function
Code
3210
Function
xx11
BP60 in input mode
11xx
BP63 in input mode
xx10
BP60 in output mode
10xx
BP63 in output mode
xx0x
BP60 enable alternate port function
(T3O for Timer 3)
0xxx
BP63 enable alternate port function
(T3I for Timer 3)
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Universal Timer/Counter/ The Universal Timer/Counter/Communication Module (UTCM) consists of three timers
Communication Module (Timer 1,Timer 2, Timer 3) and a Synchronous Serial Interface (SSI).
• Timer 1 is an interval timer that can be used to generate periodic interrupts and as
(UTCM)
prescaler for Timer 2, Timer 3, the serial interface and the watchdog function.
•
Timer 2 is an 8/12-bit timer with an external clock input (T2I) and an output (T2O).
•
Timer 3 is an 8-bit timer/counter with its own input (T3I) and output (T3O).
•
The SSI operates as a two-wire serial interface or as a shift register for modulation
and demodulation. The modulator and demodulator units work together with the
timers and shift the data bits into or out of the shift register.
There is a multitude of modes in which the timers and the serial interface can work
together.
Figure 27. UTCM Block Diagram
SYSCL
from clock module
SUBCL
Timer 1
NRST
Watchdog
MUX
INT2
Interval/Prescaler
Timer 3
T1OUT
Capture 3
T3I
Control
8-bit Counter 3
Demodulator 3
Compare 3/1
Modulator 3
MUX
T3O
INT5
Compare 3/2
Timer 2
TOG3
4-bit Counter 2/1
MUX
Compare 2/1
Modulator 2
T2O
I/O bus
Control
POUT
T2I
8-bit Counter 2/2
MUX
DCG
INT4
Compare 2/2
TOG2
SSI
SCL
Receive buffer
MUX
8-bit shift register
SC
Control
SD
Transmit buffer
INT3
29
4594C–4BMCU–12/04
Timer 1
Timer 1 is an interval timer which can be used to generate periodic interrupts and as
prescaler for Timer 2, Timer 3, the serial interface and the watchdog function.
The Timer 1 consists of a programmable 14-stage divider that is driven by either SUBCL
or SYSCL. The timer output signal can be used as a prescaler clock or as a SUBCL and
as a source for the Timer 1 interrupt. Because of other system requirements the Timer 1
output T1OUT is synchronized with SYSCL. Therefore, in the power-down mode SLEEP
(CPU core -> sleep and OSC-Stop -> yes), the output T1OUT is stopped (T1OUT = 0).
Nevertheless, Timer 1 can be active in SLEEP and generate Timer 1 interrupts. The
interrupt is maskable via the T1IM bit and the SUBCL can be bypassed via the T1BP bit
of the T1C2 register. The time interval for the timer output can be programmed via
Timer 1 control register T1C1.
This timer starts running automatically after any power-on reset. If the watchdog function is not activated, the timer can be restarted by writing into the T1C1 register with
T1RM = 1.
Timer 1 can also be used as a watchdog timer to prevent a system from stalling. The
watchdog timer is a 3-bit counter that is supplied by a separate output of Timer 1. It generates a system reset when the 3-bit counter overflows. To avoid this, the 3-bit counter
must be reset before it overflows. The application software has to accomplish this by
reading the CWD register.
After power-on reset the watchdog must be activated by software in the $RESET initialization routine. There are two watchdog modes, in one mode the watchdog can be
switched on and off by software, in the other mode the watchdog is active and locked.
This mode can only be stopped by carrying out a system reset.
The watchdog timer operation mode and the time interval for the watchdog reset can be
programmed via the watchdog control register (WDC).
Figure 28. Timer 1 Module
SYSCL
SUBCL
WDCL
MUX
CL1
14-bit
Prescaler
4-bit
Watchdog
NRST
INT2
T1CS
T1BP
T1MUX
30
T1IM
T1OUT
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 29. Timer 1 and Watchdog
T1C2
T1C1 T1RM T1C2 T1C1 T1C0
T1BP T1IM
3
Write of the
T1C1 register
T1IM=0
T1MUX
Decoder
INT2
MUX for interval timer
T1IM=1
T1OUT
RES Q1 Q2 Q3 Q4 Q5
CL1
CL
Q6
Q8
Q11
Q14 SUBCL
Q8
Q11
Q14
Watchdog
Divider/8
MUX for watchdog timer
Decoder
2
WDC WDL
WDR WDT1 WDT0
WDCL
Divider
RESET
RESET
(NRST)
RES
Read of the
CWD register
Watchdog
mode control
Timer 1 Control Register 1
(T1C1)
Address: '7'hex - Subaddress: '8'hex
T1C1
Bit 3
Bit 2
Bit 1
Bit 0
T1RM
T1C2
T1C1
T1C0
Reset value: 1111b
Bit 3 = MSB, Bit 0 = LSB
T1RM
Timer 1 Restart Mode
T1RM = 0, write access without Timer 1 restart
T1RM = 1, write access with Timer 1 restart
Note: if WDL = 0, Timer 1 restart is impossible
T1C2
Timer 1 Control bit 2
T1C1
Timer 1 Control bit 1
T1C0
Timer 1 Control bit 0
The three bits T1C[2:0] select the divider for timer 1. The resulting time interval depends
on this divider and the timer 1 input clock source. The timer input can be supplied by the
system clock, the 32 kHz oscillator or via clock management. If clock management generates the SUBCL, the selected input clock from the RC oscillator, 4 MHz oscillator or an
external clock is divided by 16.
31
4594C–4BMCU–12/04
Table 15. Timer 1 Control Bits
T1C2 T1C1 T1C0 Divider
Time Interval with
SUBCL
Time Interval with
SUBCL = 32 kHz
Time Interval with
SYSCL = 2/1 MHz
0
0
0
2
SUBCL/2
61 µs
1 µs/2 µs
0
0
1
4
SUBCL/4
122 µs
2 µs/4 µs
0
1
0
8
SUBCL/8
244 µs
4 µs/8 µs
0
1
1
16
SUBCL/16
488 µs
8 µs/16 µs
1
0
0
32
SUBCL/32
0.977 ms
16 µs/32 µs
1
0
1
256
SUBCL/256
7.812 ms
128 µs/256 µs
1
1
0
2048
SUBCL/2048
62.5 ms
1024 µs/2048 µs
1
1
1
16384
SUBCL/16384
500 ms
8192 µs/16384 µs
Timer 1 Control Register 2
(T1C2)
Address: ’7’hex - Subaddress: ’9’hex
T1C2
Bit 3
Bit 2
Bit 1
Bit 0
–
T1BP
T1CS
T1IM
Reset value: x111b
Bit 3 = MSB, Bit 0 = LSB
T1BP
Timer 1 SUBCL ByPassed
T1BP = 1, TIOUT = T1MUX
T1BP = 0, T1OUT = SUBCL
T1CS
Timer 1 input Clock Select
T1CS = 1, CL1 = SUBCL (see Figure 28 on page 30)
T1CS = 0, CL1 = SYSCL (see Figure 28 on page 30)
T1IM
Timer 1 Interrupt Mask
T1IM = 1, disables Timer 1 interrupt
T1IM = 0, enables Timer 1 interrupt
Watchdog Control Register
(WDC)
Address: ’7’hex - Subaddress: ’A’hex
WDC
Bit 3
Bit 2
Bit 1
Bit 0
WDL
WDR
WDT1
WDT0
Reset value: 1111b
Bit 3 = MSB, Bit 0 = LSB
WDL
WatchDog Lock mode
WDL = 1, the watchdog can be enabled and disabled by using the WDR bit
WDL = 0, the watchdog is enabled and locked. In this mode the WDR bit has no
effect. After the WDL bit is cleared, the watchdog is active until a
system reset or power-on reset occurs.
WDR
WatchDog Run and stop mode
WDR = 1, the watchdog is stopped/disabled
WDR = 0, the watchdog is active/enabled
WDT1
WatchDog Time 1
WDT0
WatchDog Time 0
Both these bits control the time interval for watchdog reset.
32
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Table 16. Watchdog Time Control Bits
Timer 2
WDT1
WDT0
Divider
Delay Time to Reset with
SUBCL = 32 kHz
Delay Time to Reset with
SYSCL = 2/1 MHz
0
0
512
15.625 ms
0.256 ms/0.512 ms
0
1
2048
62.5 ms
1.024 ms/2.048 ms
1
0
16384
0.5 s
8.2 ms/16.4 ms
1
1
131072
4s
65.5 ms/131 ms
This is an 8-bit or 12-bit timer need for
•
Interrupt, square-wave, pulse and duty cycle generation
•
Baud-rate generation for the internal shift register
•
Manchester and bi-phase modulation together with the SSI
•
Carrier frequency generation and modulation together with the SSI
Timer 2 can be used as an interval timer for interrupt generation, as a signal generator
or as a baud-rate generator and modulator for the serial interface. It consists of a 4-bit
and an 8-bit up counter stage which both have compare registers. The 4-bit counter
stages of Timer 2 are cascadable as a 12-bit timer or as 8-bit timer with a 4-bit prescaler. The timer can also be configured as an 8-bit timer and a separate 4-bit prescaler.
Timer 2 input can be supplied via the system clock, the external input clock (T2I), the
Timer 1 output clock, the Timer 3 output clock or the shift clock of the serial interface.
The external input clock T2I is not synchronized with SYSCL. Therefore, it is possible to
use Timer 2 with a higher clock speed than SYSCL. Furthermore, with that input clock
Timer 2 operates in the power-down mode SLEEP (CPU core →sleep and OSC-Stop →
yes) as well as in POWER-DOWN (CPU core →sleep and OSC-Stop →no). All other
clock sources supply no clock signal in SLEEP if NSTOP = 0. The 4-bit counter stages
of Timer 2 have an additional clock output (POUT).Its output has a modulator stage that
allows the generation of pulses as well as the generation and modulation of carrier frequencies. Timer 2 output can modulate with the shift register data output to generate Biphase- or Manchester-code.
If the serial interface is used to modulate a bit-stream, the 4-bit stage of Timer 2 has a
special task. The shift register can only handle bit-stream lengths divisible by 8. For
other lengths, the 4-bit counter stage can be used to stop the modulator after the right
bit-count is shifted out.
If the timer is used for carrier frequency modulation, the 4-bit stage works together with
an additional 2-bit duty cycle generator like a 6-bit prescaler to a generate carrier frequency and duty cycle. The 8-bit counter is used to enable and disable the modulator
output for a programmable count of pulses.
For programming the time interval, the timer has a 4-bit and an 8-bit compare register.
For programming the timer function, it has four modes and control registers. The comparator output of stage 2 is controlled by a special compare mode register (T2CM). This
register contains mask bits for the actions (counter reset, output toggle, timer interrupt)
which can be triggered by a compare match event or the counter overflow. This architecture enables the timer to function in various modes.
Timer 2 has a 4-bit compare register (T2CO1) and an 8-bit compare register (T2CO2).
Both these compare registers are cascadable as a 12-bit compare register, or 8-bit compare register and 4-bit compare register.
33
4594C–4BMCU–12/04
For 12-bit compare data value:
m=x+1
0 ≤x ≤4095
For 8-bit compare data value:
n=y+1
0 ≤y ≤255
For 4-bit compare data value:
l=z+1
0 ≤z ≤15
Figure 30. Timer 2
I/O-bus
P4CR
T2M1
T2M2
T2I
DCGO
SYSCL
T1OUT
TOG3
SCL
CL2/1
4-bit Counter 2/1
RES
T2O
CL2/2
OVF1
DCG
POUT
8-bit Counter 2/2
RES
OUTPUT
OVF2
TOG2
T2C
Compare 2/1
Control
M2
Compare 2/2
MOUT
to
Modulator 3
INT4
Bi-phase
Manchester
modulator
CM1
T2CO1
T2CM
T2CO2
Timer 2
modulator
output-stage
SSI POUT
SO
Control
I/O-bus
SSI
Timer 2 Modes
SSI
Mode 1: 12-bit Compare Counter
The 4-bit stage and the 8-bit stage work together as a 12-bit compare counter. A compare match signal of the 4-bit and the 8-bit stage generates the signal for the counter
reset, toggle flip-flop or interrupt. The compare action is programmable via the compare
mode register (T2CM). The 4-bit counter overflow (OVF1) supplies the clock output
(POUT) with clocks. The duty cycle generator (DCG) has to be bypassed in this mode.
Figure 31. 12-bit Compare Counter
POUT (CL2/1 /16)
CL2/1
4-bit counter
DCG
OVF2
8-bit counter
RES
TOG2
RES
INT4
4-bit compare
8-bit compare
CM2
CM1
4-bit register
34
Timer 2
output mode
and T2OTM-bit
T2D1, 0
8-bit register
T2RM
T2OTM
T2IM
T2CTM
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Mode 2: 8-bit Compare Counter with 4-bit Programmable Prescaler
The 4-bit stage is used as programmable prescaler for the 8-bit counter stage. In this
mode, a duty cycle stage is also available. This stage can be used as an additional 2-bit
prescaler or for generating duty cycles of 25%, 33% and 50%. The 4-bit compare output
(CM1) supplies the clock output (POUT) with clocks.
Figure 32. 8-bit Compare Counter
DCGO
POUT
CL2/1
OVF2
4-bit counter
DCG
8-bit counter
RES
TOG2
RES
INT4
4-bit compare
CM2
8-bit compare
CM1
Timer 2
output mode
and T2OTM-bit
4-bit register
T2D1, 0
8-bit register
T2RM
T2OTM
T2IM
T2CTM
Mode 3/4: 8-bit Compare Counter and 4-bit Programmable Prescaler
In these modes the 4-bit and the 8-bit counter stages work independently as a 4-bit
prescaler and an 8-bit timer with an 2-bit prescaler or as a duty cycle generator. Only in
mode 3 and mode 4, can the 8-bit counter be supplied via the external clock input (T2I)
which is selected via the P4CR register. The 4-bit prescaler is started by activating
mode 3 and stopped and reset in mode 4. Changing mode 3 and 4 has no effect for the
8-bit timer stage. The 4-bit stage can be used as a prescaler for Timer 3, the SSI or to
generate the stop signal for modulator 2 and modulator 3.
Figure 33. 4-/8-bit Compare Counter
DCGO
T2I
CL2/2
SYSCL
DCG
8-bit counter
OVF2
TOG2
RES
INT4
8-bit compare
CM2
Timer 2
output mode
and T2OTM-bit
P4CR P41M2, 1
TOG3
T1OUT
SYSCL
SCL
MUX
CL2/1
T2D1, 0
8-bit register
T2RM
T2OTM
T2IM
T2CTM
4-bit counter
RES
4-bit compare
T2CS1, 0
CM1
POUT
4-bit register
35
4594C–4BMCU–12/04
Timer 2 Output Modes
The signal at the timer output is generated via modulator 2. In the toggle mode, the compare match event toggles the output T2O. For high resolution duty cycle modulation 8
bits or 12 bits can be used to toggle the output. In the duty cycle burst modulator modes
the DCG output is connected to T2O and switched on and off either by the toggle
flip-flop output or the serial data line of the SSI. Modulator 2 also has 2 modes to output
the content of the serial interface as Bi-phase- or Manchester-code.
The modulator output stage can be configured by the output control bits in the T2M2
register. The modulator is started with the start of the shift register (SIR = 0) and
stopped either by carrying out a shift register stop (SIR = 1) or compare match event of
stage 1 (CM1) of Timer 2. For this task, Timer 2 mode 3 must be used and the prescaler
has to be supplied with the internal shift clock (SCL).
Figure 34. Timer 2 Modulator Output Stage
DCGO
SO
TOG2
T2O
RE
SSI
CONTROL
FE
Bi-phase
Manchester
modulator
Toggle
S1
S3
M2
S2
RES/SET
Modulator 3
OMSK
M2
T2M2 T2OS2, 1, 0 T2TOP
Timer 2 Output Signals
Timer 2 Output Mode 1
Toggle Mode A: A Timer 2 compare match toggles the output flip-flop (M2) -> T2O
Figure 35. Interrupt Timer/Square Wave Generator – the Output Toggles with Each
Edge Compare Match Event
Input
Counter 2
T2R
0
0
0
1
2
3
4
0
1
2
3
4
0
1
2
3
4
0
1
Counter 2
CMx
INT4
T2O
36
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Toggle Mode B: A Timer 2 compare match toggles the output flip-flop (M2) -> T2O
Figure 36. Pulse Generator – the Timer Output Toggles with the Timer Start If the
T2TS-bit Is Set
Input
Counter 2
T2R
0
0
0
1
2
3
4
5
6
7
4095/
255 0
1
2
3
4
5
6
Counter 2
CMx
INT4
T2O
Toggle
by start
T2O
Toggle Mode C: A Timer 2 compare match toggles the output flip-flop (M2) -> T2O
Figure 37. Pulse Generator – the Timer Toggles with Timer Overflow and Compare
Match
Input
Counter 2
T2R
0
0
0
1
2
3
4
5
6
7
4095/
255 0
1
2
3
4
5
6
Counter 2
CMx
OVF2
INT4
T2O
37
4594C–4BMCU–12/04
Timer 2 Output Mode 2
Duty Cycle Burst Generator 1: The DCG output signal (DCGO) is given to the output,
and gated by the output flip-flop (M2)
Figure 38. Carrier Frequency Burst Modulation with Timer 2 Toggle Flip-flop Output
DCGO
1 2 0 1 2 0 1 2 3 4 5 0 1 2 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5
Counter 2
TOG2
M2
T2O
Counter = compare register (= 2)
Timer 2 Output Mode 3
Duty Cycle Burst Generator 2: The DCG output signal (DCGO) is given to the output,
and gated by the SSI internal data output (SO)
Figure 39. Carrier Frequency Burst Modulation with the SSI Data Output
DCGO
1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1
Counter 2
Counter = compare register (= 2)
TOG2
SO
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
T2O
Timer 2 Output Mode 4
Bi-phase Modulator: Timer 2 Modulates the SSI Internal Data Output (SO) to Bi-phase
Code.
Figure 40. Bi-phase Modulation
TOG2
SC
8-bit SR Data
SO
0
0
1
1
0
1
0
Bit 7
T2O
0
1
Bit 0
0
1
1
0
1
0
1
Data: 00110101
38
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Timer 2 Output Mode 5
Manchester Modulator: Timer 2 Modulates the SSI internal data output (SO) to
Manchester code
Figure 41. Manchester Modulation
TOG2
SC
8-bit SR Data
0
SO
0
1
1
0
1
0
1
Bit 0
Bit 7
0
T2O
0
1
1
0
1
0
1
Bit 7
Bit 0
Data: 00110101
Timer 2 Output Mode 7
In this mode the timer overflow defines the period and the compare register defines the
duty cycle. During one period only the first compare match occurrence is used to toggle
the timer output flip-flop, until the overflow all further compare match are ignored. This
avoids the situation where changing the compare register causes the occurrence of several compare matches during one period. The resolution at the pulse-width modulation
Timer 2 mode 1 is 12-bit and all other Timer 2 modes are 8-bit.
PWM Mode: Pulse-width modulation output on Timer 2 output pin (T2O)
Figure 42. PWM Modulation
Input clock
Counter 2/2
T2R
0
0
50
255 0
100
255 0
150
255 0 50
255 0
100
Counter 2/2
CM2
OVF2
load the next
compare value
INT4
T2O
T1
T2CO2 = 150
T2
T
load
T3
T
load
T1
T
T2
T
T
39
4594C–4BMCU–12/04
Timer 2 Registers
Timer 2 has 6 control registers to configure the timer mode, the time interval, the input
clock and its output function. All registers are indirectly addressed using extended
addressing as described in the section “Addressing Peripherals”. The alternate functions of the Ports BP41 or BP42 must be selected with the Port 4 control register P4CR
if one of the Timer 2 modes require an input at T2I/BP41 or an output at T2O/BP42.
Timer 2 Control Register (T2C)
Address: '7'hex - Subaddress: '0'hex
Bit 3
Bit 2
Bit 1
Bit 0
T2C
T2CS1
T2CS0
T2TS
T2R
T2CS1
Timer 2 Clock Select bit 1
T2CS0
Timer 2 Clock Select bit 0
Reset value: 0000b
Table 17. Timer 2 Clock Select Bits
T2CS1
T2CS0
0
0
System clock (SYSCL)
0
1
Output signal of Timer 1 (T1OUT)
1
0
Internal shift clock of SSI (SCL)
1
1
Output signal of Timer 3 (TOG3)
Input Clock (CL 2/1) of Counter Stage 2/1
T2TS
Timer 2 Toggle with Start
T2TS = 0, the output flip-flop of Timer 2 is not toggled with the timer start
T2TS = 1, the output flip-flop of Timer 2 is toggled when the timer is started with T2R
T2R
Timer 2 Run
T2R = 0, Timer 2 stop and reset
T2R = 1, Timer 2 run
Timer 2 Mode Register 1 (T2M1)
Address: '7'hex - Subaddress: '1'hex
Bit 3
Bit 2
Bit 1
Bit 0
T2M1
T2D1
T2D0
T2MS1
T2MS0
T2D1
Timer 2 Duty cycle bit 1
T2D0
Timer 2 Duty cycle bit 0
Reset value: 1111b
Table 18. Timer 2 Duty Cycle Bits
40
T2D1
T2D0
Function of Duty Cycle Generator (DCG)
Additional Divider Effect
1
1
Bypassed (DCGO0)
/1
1
0
Duty cycle 1/1 (DCGO1)
/2
0
1
Duty cycle 1/2 (DCGO2)
/3
0
0
Duty cycle 1/3 (DCG03)
/4
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
T2MS1
Timer 2 Mode Select bit 1
T2MS0
Timer 2 Mode Select bit 0
Table 19. Timer 2 Mode Select Bits
Mode
T2MS1
T2MS0
1
1
2
1
3
0
4
Duty Cycle Generator
0
Clock Output (POUT)
Timer 2 Modes
1
4-bit counter overflow (OVF1)
12-bit compare counter; the
DCG has to be bypassed in this
mode
0
4-bit compare output (CM1)
8-bit compare counter with 4-bit
programmable prescaler and
duty cycle generator
4-bit compare output (CM1)
8-bit compare counter clocked by
SYSCL or the external clock
input T2I, 4-bit prescaler runs,
the counter 2/1 starts after
writing mode 3
4-bit compare output (CM1)
8-bit compare counter clocked by
SYSCL or the external clock
input T2I, 4-bit prescaler stops
and resets
1
0
The duty cycle generator generates duty cycles of 25%, 33% or 50%. The frequency at
the duty cycle generator output depends on the duty cycle and the Timer 2 prescaler
setting. The DCG-stage can also be used as an additional programmable prescaler for
Timer 2.
Figure 43. DCG Output Signals
DCGIN
DCGO0
DCGO1
DCGO2
DCGO3
41
4594C–4BMCU–12/04
Timer 2 Mode Register 2 (T2M2)
Address: '7'hex - Subaddress: '2'hex
T2M2
Bit 3
Bit 2
Bit 1
Bit 0
T2TOP
T2OS2
T2OS1
T2OS0
Reset value: 1111b
T2TOP
Timer 2 Toggle Output Preset
This bit allows the programmer to preset the Timer 2 output T2O.
T2TOP = 0, resets the toggle outputs with the write cycle (M2 = 0)
T2TOP = 1, sets toggle outputs with the write cycle (M2 = 1)
Note: If T2R = 1, no output preset is possible
T2OS2
Timer 2 Output Select bit 2
T2OS1
Timer 2 Output Select bit 1
T2OS0
Timer 2 Output Select bit 0
Table 20. Timer 2 Output Select Bits
Output
Mode
T2OS2
T2OS1
T2OS0
1
1
1
1
Toggle mode: a Timer 2 compare match toggles the
output flip-flop (M2) -> T2O
2
1
1
0
Duty cycle burst generator 1: the DCG output signal
(DCG0) is given to the output and gated by the output
flip-flop (M2)
3
1
0
1
Duty cycle burst generator 2: the DCG output signal
(DCGO) is given to the output and gated by the SSI
internal data output (SO)
4
1
0
0
Bi-phase modulator: Timer 2 modulates the SSI
internal data output (SO) to Bi-phase code
5
0
1
1
Manchester modulator: Timer 2 modulates the SSI
internal data output (SO) to Manchester code
6
0
1
0
SSI output: T2O is used directly as SSI internal data
output (SO)
7
0
0
1
PWM mode: an 8/12-bit PWM mode
8
0
0
0
Not allowed
Clock Output
If one of these output modes is used the T2O alternate function of Port 4 must also be
activated.
Timer 2 Compare and Compare
Mode Registers
Timer 2 has two separate compare registers, T2CO1 for the 4-bit stage and T2CO2 for
the 8-bit stage of Timer 2. The timer compares the contents of the compare register current counter value, and if it matches, it generates an output signal. Dependent on the
timer mode, this signal is used to generate a timer interrupt, to toggle the output flip-flop
as an SSI clock or as a clock for the next counter stage.
In the 12-bit timer mode, T2CO1 contains bits 0 to 3 and T2CO2 bits 4 to 11 of the 12-bit
compare value. In all other modes, the two compare registers work independently as a
4- and 8-bit compare register.
When assigned to the compare register a compare event will be suppressed.
42
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Timer 2 Compare Mode
Register (T2CM)
Address: '7'hex - Subaddress: '3'hex
T2CM
Bit 3
Bit 2
Bit 1
Bit 0
T2OTM
T2CTM
T2RM
T2IM
Reset value: 0000b
T2OTM
Timer 2 Overflow Toggle Mask bit
T2OTM = 0, disable overflow toggle
T2OTM = 1, enable overflow toggle, a counter overflow (OVF2) toggles the output
flip-flop (TOG2). If the T2OTM-bit is set, only a counter overflow
can generate an interrupt except on the Timer 2 output mode 7.
T2CTM
Timer 2 Compare Toggle Mask bit
T2CTM = 0, disable compare toggle
T2CTM = 1, enable compare toggle, a match of the counter with the compare
register toggles output flip-flop (TOG2). In Timer 2 output mode 7
and when the T2CTM-bit is set, only a match of the counter with the
compare register can generate an interrupt.
T2RM
Timer 2 Reset Mask bit
T2RM = 0, disable counter reset
T2RM = 1, enable counter reset, a match of the counter with the compare register
resets the counter
T2IM
Timer 2 Interrupt Mask bit
T2IM = 0, disable Timer 2 interrupt
T2IM = 1, enable Timer 2 interrupt
Table 21. Timer 2 Toggle Mask Bits
Timer 2 Output Mode
T2OTM
T2CTM
1, 2, 3, 4, 5 and 6
0
x
Compare match (CM2)
1, 2, 3, 4, 5 and 6
1
x
Overflow (OVF2)
7
x
1
Compare match (CM2)
Timer 2 COmpare Register 1
(T2CO1)
Timer 2 Interrupt Source
Address: '7'hex -Subaddress: '4'hex
T2CO1
Write cycle
Bit 3
Bit 2
Bit 1
Bit 0
Reset value: 1111b
In prescaler mode the clock is bypassed if the compare register T2CO1 contains 0.
Timer 2 COmpare Register 2
(T2CO2) Byte Write
Address: '7'hex - Subaddress: '5'hex
T2CO2
First write
cycle
Bit 3
Bit 2
Bit 1
Bit 0
Reset value: 1111b
Second write
cycle
Bit 7
Bit 6
Bit 5
Bit 4
Reset value: 1111b
43
4594C–4BMCU–12/04
Timer 3
Features
•
2 compare registers
•
Capture register
•
Edge sensitive input with zero cross detection capability
•
Trigger and single action modes
•
Output control modes
•
Automatically modulation and demodulation modes
•
FSK modulation
•
Pulse width modulation (PWM)
•
Manchester demodulation together with SSI
•
Bi-phase demodulation together with SSI
•
Pulse-width demodulation together with SSI
Figure 44. Timer 3
I/O-bus
T3CS
T3M
T3I
T3EX
SCI
T3I
T3CP
Demodulator 3
CM31
CP3
SI
RES
T3EX
SYSCL
T1OUT
POUT
CL3
INT5
8-bit Counter 3
T3C
T3ST
TOG3
SO
Control
RES
Compare 3/1
Compare 3/2
Control
T3O
Modulator 3
M2
TOG2
T3CO1
T3CO2
T3CM1
T3CM2
I/O-bus
Timer 2
SSI
SSI
Timer 3 consists of an 8-bit up-counter with two compare registers and one capture register. The timer can be used as an event counter, a timer and a signal generator. Its
output can be programmed as modulator and demodulator for the serial interface. The
two compare registers enable various modes of signal generation, modulation and
demodulation. The counter can be driven by internal and external clock sources. For
external clock sources, it has a programmable edge-sensitive input which can be used
as a counter input, a capture signal input or a trigger input. This timer input is synchronized with SYSCL. Therefore, in the power-down mode SLEEP (CPU core -> sleep and
OSC-Stop -> yes), this timer input is stopped too. The counter is readable via its capture
register while it is running. In capture mode, the counter value can be captured by a programmable capture event from the Timer 3 input or Timer 2 output.
44
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
A special feature of this timer is the trigger- and single-action mode. In trigger mode, the
counter starts counting when triggered by the external signal at its input. In single-action
mode, the counter counts only one time up to the programmed compare match event.
These modes are very useful for modulation, demodulation, signal generation, signal
measurement and phase control. For phase control, the timer input is protected against
negative voltages and has zero-cross detection capability.
Timer 3 has a modulator output stage and input functions for demodulation. As a modulator it works together with Timer 2 or the serial interface. When the shift register is used
for modulation the data shifted out of the register is encoded bitwise. In all demodulation
modes, the decoded data bits are shifted automatically into the shift register.
Timer/Counter Modes
Timer 3 has 6 timer modes and 6 modulator/demodulator modes. The mode is set via
the Timer 3 Mode Register T3M.
In all these modes, the compare register and the compare-mode register belonging to it
define the counter value for a compare match and the action of a compare match. A
match of the current counter value with the content of one compare register triggers a
counter reset, a Timer 3 interrupt or the toggling of the output flip-flop. The compare
mode registers T3M1 and T3M2 contain the mask bits for enabling or disabling these
actions.
The counter can also be enabled to execute single actions with one or both compare
registers. If this mode the corresponding compare match event is generated only once
after the counter start.
Most of the timer modes use their compare registers alternately. After the start has been
activated, the first comparison is carried out via the compare register 1, the second is
carried out via the compare register 2, the third is carried out again via the compare register 1 and so on. This makes it easy to generate signals with constant periods and
variable duty cycle or to generate signals with variable pulse and space widths.
If single-action mode is set for one compare register, the comparison is always carried
out after the first cycle via the other compare register.
The counter can be started and stopped via the control register T3C. This register also
controls the initial level of the output before a start. T3C contains the interrupt mask for a
T3I input interrupt.
Via the Timer 3 clock-select register, the internal or external clock source can be
selected. This register also selects the active edge of the external input. An edge at the
external input T3I can also generate an interrupt if the T3EIM bit is set and the Timer 3 is
stopped (T3R = 0) in the T3C register.
45
4594C–4BMCU–12/04
Figure 45. Counter 3 Stage
TOG2
T3I
T3EIM
INT5
Control
Capture register
D
T3SM1
NQ
CL3
8-bit counter
T3RM1
T3IM1
T3TM1
: T3M1
RES
CM31
8-bit comparator
Control
TOG3
C31
C32
CM32
Compare register 1
NQ
D
T3SM2
T3RM2
T3IM2
T3TM2
: T3M2
Compare register 2
The status of the timer as well as the occurrence of a compare match or an edge detect
of the input signal is indicated by the status register T2ST. This allows identification of
the interrupt source because all these events share only one timer interrupt.
Timer 3 compares data values
Timer 3 has two 8-bit compare registers (T3CO1, T3CO2). The compare data value can
be m for each of the Timer 3 compare registers.
The compare data value for the compare registers is:
0 ≤x ≤255
m = x +1
Timer 3 – Mode 1: Timer/Counter
The selected clock from an internal or external source increments the 8-bit counter. In
this mode, the timer can be used as event counter for external clocks at T3I or as a timer
for generating interrupts and pulses at T3O. The counter value can be read by the software via the capture register.
Figure 46. Counter Reset with Each Compare Match
T3R
0
0
0
1
2
3
0
1
2
3
4
5
0
1
2
3
0
1
2
3
Counter 3
CM31
CM32
INT5
T3O
46
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 47. Counter Reset with Compare Register 2 and Toggle with Start
CL3
T3R
0
0
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
Counter 3
CM31
CM32
INT5
T3O
T3O
Toggle
by start
Figure 48. Single Action of Compare Register 1
T3R
0 0 1 2 3 4 5 6 7 8 9 10 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1
Counter 3
CM31
CM32
T3O
Toggle by start
Timer 3 – Mode 2:
Timer/Counter, External Trigger Restart and External
Capture (with T3I Input)
The counter is driven by an internal clock source. After starting with T3R, the first edge
from the external input T3I starts the counter. The following edges at T3I load the current counter value into the capture register, resets the counter and restarts it. The edge
can be selected by the programmable edge decoder of the timer input stage. If single-action mode is activated for one or both compare registers the trigger signal restarts
the single action.
Figure 49. Externally Triggered Counter Reset and Start Combined with Single-action
Mode
T3R
0 0 0 0 0 0 0 0 1 2 3 4 5 6 7 8 9 10 0 1 2 X X X 0 1 2 3 4 5 6 7 8 9 10 0 1 2 X X X X
Counter 3
T3EX
CM31
CM32
T3O
47
4594C–4BMCU–12/04
Timer 3 – Mode 3:
Timer/Counter, Internal Trigger Restart and Internal Capture
(with TOG2)
The counter is driven by an internal or external (T3I) clock source. The output toggle signal of Timer 2 resets the counter. The counter value before the reset is saved in the
capture register. If single-action mode is activated for one or both compare registers, the
trigger signal restarts the single actions. This mode can be used for frequency measurements or as an event counter with a time gate (see combination mode 10).
Figure 50. Event Counter with Time Gate
T3R
T3I
0 0 1 2 3 4 5 6 7 8 910
11
0 1
2
3
Counter 3
4
0 1 2
TOG2
T3CPRegister
Capture value = 0
Timer 3 – Mode 4:
Capture value = 11
Capture value = 4
Timer/Counter
The timer runs as a timer/counter in mode 1, but its output T3O is used as an output for
the Timer 2 output signal.
Timer 3 – Mode 5:
Timer/Counter, External Trigger Restart and External
Capture (with T3I Input)
Timer 3 runs as a timer/counter in mode 2, but its output T3O is used as an output for
the Timer 2 output signal.
Timer 3 Modulator/Demodulator
Modes
Timer 3 – Mode 6:
Carrier Frequency Burst Modulation Controlled by Timer 2
Output Toggle Flip-Flop (M2)
Timer 3 counter is driven by an internal or external clock source. Its compare- and compare mode registers must be programmed to generate the carrier frequency via the
output toggle flip-flop. The output toggle flip-flop of Timer 2 is used to enable or disable
the Timer 3 output. Timer 2 can be driven by the toggle output signal of Timer 3 or any
other clock source (see combination mode 11).
Timer 3 – Mode 7:
Carrier Frequency Burst Modulation Controlled by SSI
Internal Output (SO)
Timer 3 counter is driven by an internal or external clock source. Its compare- and compare mode registers must be programmed to generate the carrier frequency via the
output toggle flip-flop. The output (SO) of the SSI is used to enable or disable the Timer
3 output. The SSI should be supplied with the toggle signal of Timer 2 (see combination
mode 12).
48
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Timer 3 – Mode 8:
FSK Modulation with Shift Register Data (SO)
The two compare registers are used for generating two different time intervals. The SSI
internal data output (SO) selects which compare register is used for the output frequency generation. A ‘0’ level at the SSI data output enables the compare register 1. A
‘1’ level enables compare register 2. The compare- and compare mode registers must
be programmed to generate the two frequencies via the output toggle flip-flop. The SSI
can be supplied with the toggle signal of Timer 2. Timer 3 counter is driven by an internal or external clock source. Timer 2 counter is driven by counter 3 (TOG3) (see also
combination mode 13).
Figure 51. FSK Modulation
T3R
0 1 2 3 4 0 1 2 3 4 0 1 2 3 4 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 3 4 0 1
Counter 3
CM31
CM32
0
SO
1
0
T3O
Timer 3 – Mode 9:
Pulse-width Modulation with the Shift Register
The two compare registers are used for generating two different time intervals. The SSI
internal data output (SO) selects which compare register is used for the output pulse
generation. In this mode both compare- and compare mode registers must be programmed for generating the two pulse widths. It is also useful to enable the single-action
mode for extreme duty cycles. Timer 2 is used as a baud rate generator and for the trigger restart of Timer 3. The SSI must be supplied with a toggle signal of Timer 2. The
counter is driven by an internal or external clock source (see combination mode 7).
Figure 52. Pulse-width Modulation
TOG2
SIR
SO
0
1
0
1
SCO
T3R
Counter 3
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 2 3 4 5 6 7 8 9101112131415 0 1 2 3 4 5 6 7 8 9101112131415 0 1 2 3 4
CM31
CM32
T3O
49
4594C–4BMCU–12/04
Timer 3 – Mode 10: Manchester Demodulation/ Pulse-width Demodulation
For Manchester demodulation, the edge detection stage must be programmed to detect
each edge at the input. These edges are evaluated by the demodulator stage. The timer
stage is used to generate the shift clock for the SSI. The compare register 1 match
event defines the correct moment for shifting the state from input T3I as the decoded bit
into shift register – after that the demodulator waits for the next edge to synchronize the
timer by a reset for the next bit. Compare register 2 can also be used to detect a timeout error and handle it with an interrupt routine (also see combination mode 8).
Figure 53. Timer 3 – Manchester Demodulation
Timer 3
mode
T3I
Synchronize
1
Manchester demodulation mode
0
1
1
1
0
0
1
1
0
T3EX
SI
CM3 = SCI
SR-DATA
1
1
1
0
0
1
1
BIT 0
BIT 1
BIT 2
BIT 3
BIT 4
BIT 5
BIT 6
0
Timer 3 – Mode 11: Bi-phase Demodulation
In the Bi-phase demodulation mode, the timer operates like in Manchester demodulation
mode. The difference is that the bits are decoded via a toggle flip-flop. This flip-flop samples the edge in the middle of the bit-frame and the compare register 1 match event
shifts the toggle flip-flop output into the shift register (see also combined mode 9).
Figure 54. Timer 3 – Bi-phase Demodulation
Timer 3
mode
T3I
Synchronize
0
Biphase demodulation mode
0
1
0
1
0
1
0
1
T3EX
Q1 = SI
CM31 = SCI
Reset
Counter 3
SR-DATA
50
0
1
1
0
1
0
1
BIT 0
BIT 1
BIT 2
BIT 3
BIT 4
BIT 5
BIT 6
0
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Timer 3 – Mode 12: Timer/Counter with External Capture Mode (T3I)
The counter is driven by an internal clock source and an edge at the external input T3I
loads the counter value into the capture register. The edge can be selected with the programmable edge detector of the timer input stage. This mode can be used for signal and
pulse measurements.
Figure 55. External Capture Mode
T3R
T3I
0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41
Counter 3
T3CPRegister
Timer 3 Modulator for Carrier
Frequency Burst Modulation
Capture value = 17
Capture value = X
Capture value = 35
If the output stage operates as a pulse-width modulator for the shift register the output
can be stopped with stage 1 of Timer 2. For this task, the timer mode 3 must be used
and the prescaler must be supplied by the internal shift clock of the shift register.
The modulator can be started with the start of the shift register (SIR = 0) and stopped
either by a shift register stop (SIR = 1) or compare match event of stage 1 of Timer 2.
For this task, Timer 2 must be used in mode 3 and the prescaler stage must be supplied
by the internal shift clock of the shift register.
Figure 56. Modulator 3
0
T3
TOG3
Set
M3
1
Res
T3TOP
2
T3O
MUX
Timer 3 Mode
6
7
9
other
SO
M2
3
SSI/
Control
T3O
MUX 1
MUX 2
MUX 3
MUX 0
OMSK
T3M
Timer 3 Demodulator for
Bi-phase, Manchester and
Pulse-width-modulated Signals
The demodulator stage of Timer 3 can be used to decode Bi-phase, Manchester and
pulse-width-coded signals.
Figure 57. Timer 3 – Demodulator 3
T3M
SCI
T3I
Demodulator 3
T3EX
SI
Res
CM31
Counter 3
Reset
Counter 3
Control
51
4594C–4BMCU–12/04
Timer 3 Registers
Timer 3 Mode Register (T3M)
Address: 'Bhex - Subaddress: '0'hex
Bit 3
Bit 2
Bit 1
Bit 0
T3M
T3M3
T3M2
T3M1
T3M0
T3M3
Timer 3 Mode select bit 3
T3M2
Timer 3 Mode select bit 2
T3M1
Timer 3 Mode select bit 1
T3M0
Timer 3 Mode select bit 0
Reset value: 1111b
Table 22. Timer 3 Mode Select Bits
Mode
T3M3
T3M2
T3M1
1
1
1
1
1
Timer/counter with a read access
2
1
1
1
0
Timer/counter, external capture and external
trigger restart mode (T3I)
3
1
1
0
1
Timer/counter, internal capture and internal trigger
restart mode (TOG2)
4
1
1
0
0
Timer/counter mode 1 without output
(T2O -> T3O)
5
1
0
1
1
Timer/counter mode 2 without output
(T2O -> T3O)
6
1
0
1
0
Burst modulation with Timer 2 (M2)
7
1
0
0
1
Burst modulation with shift register (SO)
8
1
0
0
0
FSK modulation with shift register (SO)
9
0
1
1
1
Pulse-width modulation with shift register (SO) and
Timer 2 (TOG2), internal trigger restart (SCO) ->
counter reset
10
0
1
1
0
Manchester demodulation/pulse-width
demodulation(1) (T2O -> T3O)
11
0
1
0
1
Bi-phase demodulation (T2O -> T3O)
12
0
1
0
0
Timer/counter with external capture mode (T3I)
13
0
0
1
1
Not allowed
14
0
0
1
0
Not allowed
15
0
0
0
1
Not allowed
16
0
0
0
0
Not allowed
Note:
52
T3M0 Timer 3 Modes
1. In this mode, the SSI can be used only as demodulator (8-bit NRZ rising edge). All
other SSI modes are not allowed.
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Timer 3 Control Register 1
(T3C) Write
Primary register address: ’C’hex - Write
Bit 3
Bit 2
Bit 1
Bit 0
Write
T3EIM
T3TOP
T3TS
T3R
T3EIM
Timer 3 Edge Interrupt Mask
T3EIM = 0, disables the interrupt when an edge event for Timer 3 occurs (T3I)
T3EIM = 1, enables the interrupt when an edge event for Timer 3 occurs (T3I)
T3TOP
Timer 3 Toggle Output Preset T3TOP = 0, sets toggle output (M3) to ‘0’
T3TOP = 1, sets toggle output (M3) to ‘1’
Note: If T3R = 1, no output preset is possible
T3TS
Timer 3 Toggle with Start T3TS = 0, Timer 3 output is not toggled during the start
T3TS = 1, Timer 3 output is toggled if started with T3R
T3R
Timer 3 Run
Reset value: 0000b
T3R = 0, Timer 3 stop and reset
T3R = 1, Timer 3 run
Timer 3 Status Register 1
(T3ST) Read
Primary register address: ’C’hex - Read
Read
Bit 3
Bit 2
Bit 1
Bit 0
–
T3ED
T3C2
T3C1
Reset value: x000b
T3ED
Timer 3 Edge Detect
This bit will be set by the edge-detect logic of Timer 3 input (T3I)
T3C2
Timer 3 Compare 2
This bit will be set when a match occurs between Counter 3 and T3CO2
T3C1
Timer 3 Compare 1
This bit will be set when a match occurs between Counter 3 and T3CO1
Note:
The status bits T3C1, T3C2 and T3ED will be reset after a READ access to T3ST.
Timer 3 Clock Select Register
(T3CS)
Address: ‘B’hex - Subaddress: ‘1’hex
T3CS
Bit 3
Bit 2
Bit 1
Bit 0
T3E1
T3E0
T3CS1
T3CS0
T3E1
Timer 3 Edge select bit 1
T3E0
Timer 3 Edge select bit 0
Reset value: 1111b
Table 23. External Input Edge Select Bits
T3E1
T3E0
Timer 3 Input Edge Select (T3I)
1
1
–
1
0
Positive edge at T3I pin
0
1
Negative edge at T3I pin
0
0
Each edge at T3I pin
53
4594C–4BMCU–12/04
T3CS1
Timer 3 Clock Source select bit 1
T3CS0
Timer 3 Clock Source select bit 0
Table 24. Select Clock Source Bits
Timer 3 Compare- and Compare
Mode Register
T3CS1
TCS0
Counter 3 Input Signal (CL3)
1
1
System clock (SYSCL)
1
0
Output signal of Timer 2 (POUT)
0
1
Output signal of Timer 1 (T1OUT)
0
0
External input signal from T3I edge detect
Timer 3 has two separate compare registers T3CO1 and T3CO2 for the 8-bit stage of
Timer 3. The timer compares the content of the compare register with the current
counter value. If both match, it generates a signal. This signal can be used for the
counter reset, to generate a timer interrupt, for toggling the output flip-flop, as SSI clock
or as clock for the next counter stage. For each compare register, a compare-mode register exists. These registers contain mask bits to enable or disable the generation of an
interrupt, a counter reset, or an output toggling with the occurrence of a compare match
of the corresponding compare register. The mask bits for activating the single-action
mode can also be located in the compare mode registers. When assigned to the compare register a compare event will be suppressed.
Timer 3 Compare Mode
Register 1 (T3CM1)
Address: ‘B’hex - Subaddress: ‘2’hex
T3CM1
Bit 3
Bit 2
Bit 1
Bit 0
T3SM1
T3TM1
T3RM1
T3IM1
Reset value: 0000b
T3SM1
Timer 3 Single action Mask bit 1
T3SM1 = 0, disables single-action compare mode
T3SM1 = 1, enables single-compare mode. After this bit is set, the compare
register (T3CO1) is used until the next compare match.
T3TM1
Timer 3 compare Toggle action Mask bit 1
T3TM1 = 0, disables compare toggle
T3TM1 = 1, enables compare toggle. A match of Counter 3 with the compare
register (T3CO1) toggles the output flip-flop (TOG3).
T3RM1
Timer 3 Reset Mask bit 1
T3RM1 = 0, disables counter reset
T3RM1 = 1, enables counter reset. A match of Counter 3 with the compare
register (T3CO1) resets the Counter 3.
T3IM1
Timer 3 Interrupt Mask bit 1
T3RM1 = 0, disables Timer 3 interrupt for T3CO1 register
T3RM1 = 1, enables Timer 3 interrupt for T3CO1 register
T3CM1 contains the mask bits for the match event of Counter 3 compare register 1
54
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Timer 3 Compare Mode
Register 2 (T3CM2)
Address: ‘B’hex - Subaddress: ‘3’hex
T3CM2
Bit 3
Bit 2
Bit 1
Bit 0
T3SM2
T3TM2
T3RM2
T3IM2
Reset value: 0000b
T3SM2
Timer 3 Single action Mask bit 2
T3SM2 = 0, disables single-action compare mode
T3SM2 = 1, enables single-compare mode. After this bit is set, the compare
register (T3CO2) is used until the next compare match.
T3TM2
Timer 3 compare Toggle action Mask bit 2
T3TM2 = 0, disables compare toggle
T3TM2 = 1, enables compare toggle. A match of Counter 3 with the compare
register (T3CO2) toggles the output flip-flop (TOG3).
T3RM2
Timer 3 Reset Mask bit 2
T3RM2 = 0, disables counter reset
T3RM2 = 1, enables counter reset. A match of Counter 3 with the compare
register (T3CO2) resets Counter 3.
T3IM2
Timer 3 Interrupt Mask bit 2
T3RM2 = 0, disables Timer 3 interrupt for T3CO2 register
T3RM2 = 1, enables Timer 3 interrupt for T3CO2 register
T3CM2 contains the mask bits for the match event of Counter 3 compare register 2
The compare registers and corresponding counter reset masks can be used to program
the counter time intervals and the toggle masks can be used to program the output signal. The single-action mask can also be used in this mode. It starts operating after the
timer starts with T3R.
Timer 3 COmpare Register 1
(T3CO1) Byte Write
Address: ‘B’hex - Subaddress: ‘4’hex
High Nibble
Second write cycle
Bit 7
Bit 6
First write cycle
Bit 3
Bit 2
Bit 5
Bit 4
Reset value: 1111b
Bit 0
Reset value: 1111b
Low Nibble
Timer 3 COmpare Register 2
(T3CO2) Byte Write
Bit 1
Address: ‘B’hex - Subaddress: ‘5’hex
High Nibble
Second write cycle
Bit 7
Bit 6
Bit 5
Bit 4
Reset value: 1111b
Bit 0
Reset value: 1111b
Low Nibble
First write cycle
Bit 3
Bit 2
Bit 1
55
4594C–4BMCU–12/04
Timer 3 Capture Register
The counter content can be read via the capture register. There are two ways to use the
capture register. In modes 1 and 4, it is possible to read the current counter value
directly out of the capture register. In capture modes 2, 3, 5 and 12, a capture event like
an edge at the Timer 3 input or a signal from Timer 2 stores the current counter value
into the capture register. This counter value can be read from the capture register.
Timer 3 CaPture Register
(T3CP) Byte Read
Address: ‘B’hex - Subaddress: ‘4’hex
High Nibble
First read cycle
Bit 7
Bit 6
Bit 5
Bit 4
Reset value: xxxxb
Bit 0
Reset value: xxxxb
Low Nibble
Second read cycle
Bit 3
Bit 2
Bit 1
Synchronous Serial Interface
(SSI)
SSI Features
•
2- and 3-wire NRZ
•
2-wire mode, additional internal 2-wire link for multi-chip packaging solutions
•
•
56
With Timer 2:
–
Bi-phase modulation
–
Manchester modulation
–
Pulse-width demodulation
–
Burst modulation
With Timer 3:
–
Pulse-width modulation (PWM)
–
FSK modulation
–
Bi-phase demodulation
–
Manchester demodulation
–
Pulse-width demodulation
–
Pulse position Demodulation
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
SSI Peripheral Configuration
The synchronous serial interface (SSI) can be used either for serial communication with
external devices such as EEPROMs, shift registers, display drivers, other microcontrollers, or as a means for generating and capturing on-chip serial streams of data. External
data communication takes place via Port 4 (BP4),a multifunctional port which can be
software configured by writing the appropriate control word into the P4CR register. The
SSI can be configured in any of the following ways:
1. 2-wire external interface for bi-directional data communication with one data terminal and one shift clock. The SSI uses Port BP43 as a bi-directional serial data
line (SD) and BP40 as a shift clock line (SC).
2. 3-wire external interface for simultaneous input and output of serial data, with a
serial input data terminal (SI), a serial output data terminal (SO) and a shift clock
(SC). The SSI uses BP40 as shift clock (SC), while the serial data input (SI) is
applied to BP43 (configured in P4CR as input). Serial output data (SO) in this
case is passed through to BP42 (configured in P4CR to T2O) via the Timer 2
output stage (T2M2 configured in mode 6).
3. Timer/SSI combined modes – the SSI used together with Timer 2 or Timer 3 is
capable of performing a variety of data modulation and demodulation functions
(see Timer Section). The modulating data is converted by the SSI into a continuous serial stream of data which is in turn modulated in one of the timer functional
blocks. Serial demodulated data can be serially captured in the SSI and read by
the controller. In the Timer 3 modes 10 and 11 (demodulation modes) the SSI
can only be used as demodulator.
4. Multi-chip link (MCL) – the SSI can also be used as an interchip data interface for
use in single package multi-chip modules or hybrids. For such applications, the
SSI is provided with two dedicated pads (MCL_SD and MCL_SC) which act as a
two-wire chip-to-chip link. The MCL can be activated by the MCL control bit.
Should these MCL pads be used by the SSI, the standard SD and SC pins are
not required and the corresponding Port 4 ports are available as conventional
data ports.
Figure 58. Block Diagram of the Synchronous Serial Interface
I/O-bus
Timer 2/Timer 3
SIC1
SIC2
SISC
SO
Control
SC
SI SCI
INT3
SC
SSI-Control
MCL_SC
TOG2
POUT
T1OUT
SYSCL
Output
SO
/2
SI
8-bit Shift Register
Shift_CL
MSB
LSB
STB
MCL_SD
SD
SRB
Transmit
Buffer
Receive
Buffer
I/O-bus
57
4594C–4BMCU–12/04
General SSI Operation
The SSI is comprised essentially of an 8-bit shift register with two associated 8-bit buffers – the receive buffer (SRB) for capturing the incoming serial data and a transmit
buffer (STB) for intermediate storage of data to be serially output. Both buffers are
directly accessable by software. Transferring the parallel buffer data into and out of the
shift register is controlled automatically by the SSI control, so that both single byte transfers or continuous bit streams can be supported.
The SSI can generate the shift clock (SC) either from one of several on-chip clock
sources or accept an external clock. The external shift clock is output on, or applied to
the Port BP40. Selection of an external clock source is performed by the Serial Clock
Direction control bit (SCD). In combinational modes, the required clock is selected by
the corresponding timer mode.
The SSI can operate in three data transfer modes – synchronous 8-bit shift mode, a
9-bit Multi-Chip Link mode (MCL), containing 8-bit data and 1-bit acknowledge, and a
corresponding 8-bit MCL mode without acknowledge. In both MCL modes the data
transmission begins after a valid start condition and ends with a valid stop condition.
External SSI clocking is not supported in these modes. The SSI should thus generate
and have full control over the shift clock so that it can always be regarded as an
MCL-bus master device.
All directional control of the external data port used by the SSI is handled automatically
and is dependent on the transmission direction set by the Serial Data Direction (SDD)
control bit. This control bit defines whether the SSI is currently operating in transmit (TX)
mode or receive (RX) mode.
Serial data is organized in 8-bit telegrams which are shifted with the most significant bit
first. In the 9-bit MCL mode, an additional acknowledge bit is appended to the end of the
telegram for handshaking purposes (see MCL protocol).
At the beginning of every telegram, the SSI control loads the transmit buffer into the shift
register and proceeds immediately to shift data serially out. At the same time, incoming
data is shifted into the shift register input. This incoming data is automatically loaded
into the receive buffer when the complete telegram has been received. Thus, data can
be simultaneously received and transmitted if required.
Before data can be transferred, the SSI must first be activated. This is performed by
means of the SSI reset control (SIR) bit. All further operation then depends on the data
directional mode (TX/RX) and the present status of the SSI buffer registers shown by
the Serial Interface Ready Status Flag (SRDY). This SRDY flag indicates the
(empty/full) status of either the transmit buffer (in TX mode), or the receive buffer (in RX
mode). The control logic ensures that data shifting is temporarily halted at any time, if
the appropriate receive/transmit buffer is not ready (SRDY = 0). The SRDY status will
then automatically be set back to ‘1’ and data shifting resumed as soon as the application software loads the new data into the transmit register (in TX mode) or frees the shift
register by reading it into the receive buffer (in RX mode).
A further activity status (ACT) bit indicates the present status of the serial communication. The ACT bit remains high for the duration of the serial telegram or if MCL stop or
start conditions are currently being generated. Both the current SRDY and ACT status
can be read in the SSI status register. To deactivate the SSI, the SIR bit must be set
high.
58
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
8-bit Synchronous Mode
Figure 59. 8-bit Synchronous Mode
SC
(Rising edge)
SC
(Falling edge)
DATA
0
0
1
1
0
1
0
Bit 7
SD/TO2
0
Bit 7
1
Bit 0
0
1
1
0
1
0
1
Bit 0
Data: 00110101
In 8-bit synchronous mode, the SSI can operate as either a 2- or 3-wire interface (see
SSI peripheral configuration). The serial data (SD) is received or transmitted in NRZ format, synchronized to either the rising or falling edge of the shift clock (SC). The choice
of clock edge is defined by the Serial Mode Control bits (SM0,SM1). It should be noted
that the transmission edge refers to the SC clock edge with which the SD changes. To
avoid clock skew problems, the incoming serial input data is shifted in with the opposite
edge.
When used together with one of the timer modulator or demodulator stages, the SSI
must be set in the 8-bit synchronous mode 1.
In RX mode, as soon as the SSI is activated (SIR = 0), 8 shift clocks are generated and
the incoming serial data is shifted into the shift register. This first telegram is automatically transferred into the receive buffer and the SRDY is set to 0 indicating that the
receive buffer contains valid data. At the same time an interrupt (if enabled) is generated. The SSI then continues shifting the following 8-bit telegram. If, during this time the
first telegram has been read by the controller, the second telegram will also be transferred in the same way into the receive buffer and the SSI will continue clocking in the
next telegram. Should, however, the first telegram not have been read (SRDY = 1), then
the SSI will stop, temporarily holding the second telegram in the shift register until a certain point of time when the controller is able to service the receive buffer. In this way no
data is lost or overwritten.
Deactivating the SSI (SIR = 1) in mid-telegram will immediately stop the shift clock and
latch the present contents of the shift register into the receive buffer. This can be used
for clocking in a data telegram less than 8 bits in length. Care should be taken to read
out the final complete 8-bit data telegram of a multiple word message before deactivating the SSI (SIR = 1) and terminating the reception. After termination, the shift register
contents will overwrite the receive buffer.
59
4594C–4BMCU–12/04
Figure 60. Example of an 8-bit Synchronous Transmit Operation
SC
msb
lsb
7 6 5 4 3 2 1
SD
msb
0
lsb msb
lsb
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1
tx data 1
tx data 2
0
tx data 3
SIR
SRDY
ACT
Interrupt
(IFN = 0)
Interrupt
(IFN = 1)
Write STB
(tx data 1)
Write STB
(tx data 2)
Write STB
(tx data 3)
Figure 61. Example of an 8-bit Synchronous Receive Operation
SC
msb
SD
lsb
msb
lsb
msb
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
rx data 1
lsb
7 6 5 4 3 2 1 0 7 6 5 4
rx data 2
rx data 3
SIR
SRDY
ACT
Interrupt
(IFN = 0)
Interrupt
(IFN = 1)
Read SRB
(rx data 1)
60
Read SRB
(rx data 2)
Read SRB
(rx data 3)
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
9-bit Shift Mode
In the 9-bit shift mode, the SSI is able to handle the MCL protocol (described below). It
always operates as an MCL master device, i.e., SC is always generated and output by
the SSI. Both the MCL start and stop conditions are automatically generated whenever
the SSI is activated or deactivated by the SIR-bit. In accordance with the MCL protocol,
the output data is always changed in the clock low phase and shifted in on the high
phase.
Before activating the SSI (SIR = 0) and commencing an MCL dialog, the appropriate
data direction for the first word must be set using the SDD control bit. The state of this
bit controls the direction of the data port (BP43 or MCL_SD). Once started, the 8 data
bits are, depending on the selected direction, either clocked into or out of the shift register. During the 9th clock period, the port direction is automatically switched over so that
the corresponding acknowledge bit can be shifted out or read in. In transmit mode, the
acknowledge bit received from the device is captured in the SSI Status Register (TACK)
where it can be read by the controller. In receive mode, the state of the acknowledge bit
to be returned to the device is predetermined by the SSI Status Register (RACK).
Changing the direction mode (TX/RX) should not be performed during the transfer of an
MCL telegram. One should wait until the end of the telegram which can be detected
using the SSI interrupt (IFN = 1) or by interrogating the ACT status.
Once started, a 9-bit telegram will always run to completion and will not be prematurely
terminated by the SIR bit. So, if the SIR-bit is set to ‘1’ within the telegram, the SSI will
complete the current transfer and terminate the dialog with an MCL stop condition.
Figure 62. Example of MCL Transmit Dialog
Start
Stop
SC
msb
SD
lsb
7 6 5 4 3 2 1 0 A
msb
lsb
7 6 5 4 3 2 1 0 A
tx data 1
tx data 2
SRDY
ACT
Interrupt
(IFN = 0)
Interrupt
(IFN = 1)
SIR
SDD
Write STB
(tx data 1)
Write STB
(tx data 2)
61
4594C–4BMCU–12/04
Figure 63. Example of MCL Receive Dialog
Start
Stop
SC
msb
SD
lsb
7 6 5 4 3 2 1 0 A
tx data 1
msb
lsb
7 6 5 4 3 2 1 0 A
rx data 2
SRDY
ACT
Interrupt
(IFN = 0)
Interrupt
(IFN = 1)
SIR
SDD
Write STB
(tx data 1)
Read SRB
(rx data 2)
8-bit Pseudo MCL Mode
In this mode, the SSI exhibits all the typical MCL operational features except for the
acknowledge-bit which is never expected or transmitted.
MCL Bus Protocol
The MCL protocol constitutes a simple 2-wire bi-directional communication highway via
which devices can communicate control and data information. Although the MCL protocol can support multi-master bus configurations, the SSI in MCL mode is intended for
use purely as a master controller on a single master bus system. So all reference to
multiple bus control and bus contention will be omitted at this point.
All data is packaged into 8-bit telegrams plus a trailing handshaking or acknowledge-bit.
Normally the communication channel is opened with a so-called start condition, which
initializes all devices connected to the bus. This is then followed by a data telegram,
transmitted by the master controller device. This telegram usually contains an 8-bit
address code to activate a single slave device connected onto the MCL bus. Each slave
receives this address and compares it with its own unique address. The addressed
slave device, if ready to receive data, will respond by pulling the SD line low during the
9th clock pulse. This represents a so-called MCL acknowledge. The controller detecting
this affirmative acknowledge then opens a connection to the required slave. Data can
then be passed back and forth by the master controller, each 8-bit telegram being
acknowledged by the respective recipient. The communication is finally closed by the
master device and the slave device is put back into standby by applying a stop condition
onto the bus.
62
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 64. MCL Bus Protocol 1
(1)
(2)
(4)
(4)
(3)
(1)
SC
SD
Start
condition
Data
Data
Data
valid
change
valid
Stop
condition
Bus not busy (1)
Both data and clock lines remain HIGH
Start data transfer (2)
A HIGH to LOW transition of the SD line while the clock (SC)
is HIGH defines a START condition
Stop data transfer (3)
A LOW to HIGH transition of the SD line while the clock (SC)
is HIGH defines a STOP condition
Data valid (4)
The state of the data line represents valid data when,
after the START condition, the data line is stable for the
duration of the HIGH period of the clock signal
Acknowledge
All address and data words are serially transmitted to and
from the device in 8-bit words. The receiving device
returns a zero on the data line during the ninth clock cycle to
acknowledge a word receipt.
Figure 65. MCL Bus Protocol 2
SC
1
SD
SSI Interrupt
Start
1st Bit
n
8
8th Bit
9
ACK
Stop
The SSI interrupt INT3 can be generated either by an SSI buffer register status (i.e.,
transmit buffer empty or receive buffer full), the end of SSI data telegram or on the falling edge of the SC/SD pins on Port 4 (see P4CR). SSI interrupt selection is performed
by the Interrupt FunctioN control bit (IFN). The SSI interrupt is usually used to synchronize the software control of the SSI and inform the controller of the present SSI status.
The Port 4 interrupts can be used together with the SSI or, if the SSI itself is not
required, as additional external interrupt sources. In either case this interrupt is capable
of waking the controller out of sleep mode.
To enable and select the SSI relevant interrupts use the SSI Interrupt Mask (SIM) and
the Interrupt Function (IFN) while Port 4 interrupts are enabled by setting appropriate
control bits in the P4CR register.
63
4594C–4BMCU–12/04
Modulation and Demodulation
If the shift register is used together with Timer 2 or Timer 3 for modulation or demodulation purposes, the 8-bit synchronous mode must be used. In this case, the unused
Port 4 pins can be used as conventional bi-directional ports.
The modulation and demodulation stages, if enabled, operate as soon as the SSI is activated (SIR = 0) and cease when deactivated (SIR = 1).
Due to the byte-orientated data control, the SSI (when running normally) generates
serial bit streams which are submultiples of 8 bits. An SSI Output Masking (OMSK) function permits, however, the generation of bit streams of any length. The OMSK signal is
derived indirectly from the 4-bit prescaler of Timer 2 and masks out a programmable
number of unrequired trailing data bits during the shifting out of the final data word in the
bit stream. The number of non-masked data bits are defined by the value pre-programmed in the prescaler compare register. To use output masking, the Modulator Stop
Mode bit (MSM) must be set to ‘0’ before programming the final data word into the SSI
transmit buffer. This in turn, enables shift clocks to the prescaler when this final word is
shifted out. On reaching the compare value, the prescaler triggers the OMSK signal and
all following data bits are blanked.
Internal 2-wire Multi-chip Link
Two additional on-chip pads (MCL_SC and MCL_SD) for the SC and the SD line can be
used as chip-to-chip links for multi-chip applications. These pads can be activated by
setting the MCL-bit in the SISC register.
Figure 66. Multi-chip Link
U505M
SCL
SDA
Multi-chip link
MCL_SC
MCL_SD
VDD
VSS
BP43/SD
BP40/SC
BP10
ATAR092-D
BP13
Figure 67. SSI Output Masking Function
CL2/1
Timer 2
4-bit counter 2/1
SCL
Compare 2/1
CM1
OMSK
SO
Control
SC
SSI-control
Output
TOG2
POUT
T1OUT
SYSCL
64
SO
/2
Shift_CL
MSB
8-bit shift register
SI
LSB
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Serial Interface Registers
Serial Interface Control
Register 1 (SIC1)
Auxiliary register address: '9'hex
Bit 3
Bit 2
Bit 1
Bit 0
SIC1
SIR
SCD
SCS1
SCS0
SIR
Serial Interface Reset
SIR = 1, SSI inactive
SIR = 0, SSI active
SCD
Serial Clock Direction
SCD = 1, SC line used as output
SCD = 0, SC line used as input
Note:
Reset value: 1111b
This bit has to be set to '1' during the MCL mode and the Timer 3 mode 10 or 11
SCS1
Serial Clock source Select bit 1
SCS0
Serial Clock source Select bit 0
Note:
With SCD = '0' the bits SCS1 and SCS0 are insignificant
Table 25. Serial Clock Source Select Bits
SCS1
SCS0
1
1
SYSCL/2
Internal Clock for SSI
1
0
T1OUT/2
0
1
POUT/2
0
0
TOG2/2
•
In Transmit mode (SDD = 1) shifting starts only if the transmit buffer has been
loaded (SRDY = 1).
•
Setting SIR bit loads the contents of the shift register into the receive buffer
(synchronous 8-bit mode only).
•
In MCL modes, writing a 0 to SIR generates a start condition and writing a 1
generates a stop condition.
Serial Interface Control
Register 2 (SIC2)
Auxiliary register address: ’A’hex
SIC2
Bit 3
Bit 2
Bit 1
Bit 0
MSM
SM1
SM0
SDD
Reset value: 1111b
MSM
Modular Stop Mode
MSM = 1, modulator stop mode disabled (output masking off)
MSM = 0, modulator stop mode enabled (output masking on) - used in
modulation modes for generating bit streams which are not submultiples of 8 bit.
SM1
Serial Mode control bit 1
SM0
Serial Mode control bit 0
65
4594C–4BMCU–12/04
Table 26. Serial Mode Control Bits
Mode
SM1
SM0
1
1
1
8-bit NRZ-data changes with the rising edge of SC
2
1
0
8-bit NRZ-data changes with the falling edge of SC
3
0
1
9-bit 2-wire MCL mode
4
0
0
8-bit 2-wire pseudo MCL mode (no acknowledge)
SDD
Note:
SSI Mode
Serial Data Direction
SDD = 1, transmit mode – SD line used as output (transmit data). SRDY is set by
a transmit buffer write access
SDD = 0, receive mode – SD line used as input (receive data). SRDY is set by a
receive buffer read access
SDD controls port directional control and defines the reset function for the SRDY-flag
Serial Interface Status and
Control Register (SISC)
66
Primary register address: ’A’hex
Bit 3
Bit 2
Bit 1
Bit 0
Write
MCL
RACK
SIM
IFN
Reset value: 1111b
Read
–
TACK
ACT
SRDY
Reset value: xxxxb
MCL
Multi-Chip Link activation
MCL = 1, multi-chip link disabled. This bit has to be set to 0 during
transactions to/from the EEPROM of the ATAR092-D
MCL = 0, connects SC and SD additionally to the internal multi-chip link pads
RACK
Receive ACKnowledge status/control bit for MCL mode
RACK = 0, transmit acknowledge in next receive telegram
RACK = 1, transmit no acknowledge in last receive telegram
TACK
Transmit ACKnowledge status/control bit for MCL mode
TACK = 0, acknowledge received in last transmit telegram
TACK = 1, no acknowledge received in last transmit telegram
SIM
Serial Interrupt Mask
SIM = 1, disable interrupts
SIM = 0, enable serial interrupt. An interrupt is generated.
IFN
Interrupt FuNction
IFN = 1, the serial interrupt is generated at the end of the telegram
IFN = 0, the serial interrupt is generated when the SRDY goes low
(i.e., buffer becomes empty/full in transmit/receive mode)
SRDY
Serial interface buffer ReaDY status flag
SRDY = 1, in receive mode: receive buffer empty
in transmit mode: transmit buffer full
SRDY = 0, in receive mode: receive buffer full
in transmit mode: transmit buffer empty
ACT
Transmission ACTive status flag
ACT = 1, transmission is active, i.e., serial data transfer. Stop or start
conditions are currently in progress.
ACT = 0, transmission is inactive
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Serial Transmit Buffer
(STB) – Byte Write
Primary register address: ’9’hex
STB
First write cycle
Bit 3
Bit 2
Bit 1
Bit 0
Reset value: xxxxb
Second write cycle
Bit 7
Bit 6
Bit 5
Bit 4
Reset value: xxxxb
The STB is the transmit buffer of the SSI. The SSI transfers the transmit buffer into the shift register and starts shifting with the most significant bit.
Serial Receive Buffer
(SRB) – Byte Read
Primary register address: ’9’hex
SRB
First read cycle
Bit 7
Bit 6
Bit 5
Bit 4
Reset value: xxxxb
Second read cycle
Bit 3
Bit 2
Bit 1
Bit 0
Reset value: xxxxb
The SRB is the receive buffer of the SSI. The shift register clocks serial data in (most significant
bit first) and the loads content into the receive buffer when the complete telegram has been
received.
Combination Modes
The UTCM consists of two timers (Timer 2 and Timer 3) and a serial interface. There is
a multitude of modes in which the timers and serial interface can work together.
The 8-bit wide serial interface operates as a shift register for modulation and demodulation. The modulator and demodulator units work together with the timers and shift the
data bits into or out of the shift register.
Combination Mode Timer 2 and
SSI
Figure 68. Combination Timer 2 and SSI
I/O-bus
P4CR
T2M1
T2M2
T2I
DCGO
SYSCL
T1OUT
TOG3
SCL
CL2/1
RES
T2C
OVF1
T2O
CL2/2
4-bit counter 2/1
DCG
POUT
Compare 2/1
RES
Timer 2 - control
Output
8-bit counter 2/2
OVF2
TOG2
Compare 2/2
MOUT
INT4
POUT
T2CO1
Bi-phase
Manchester
modulator
CM1
T2CM
T2CO2
TOG2
SO
Timer 2
modulator
output-stage
Control
I/O-bus
SIC1
SIC2
SISC
Control
TOG2
POUT
T1OUT
SYSCL
INT3
SCLI
SO
SC
SSI-control
MCL_SC
SCL
Output
SO
SI
8-bit shift register
Shift_CL
MSB
MCL_SD
SD
LSB
STB
SRB
Transmit
buffer
Receive
buffer
I/O-bus
67
4594C–4BMCU–12/04
Combination Mode 1: Burst Modulation
SSI mode 1:
8-bit NRZ and internal data SO output to Timer 2
modulator stage
8-bit compare counter with 4-bit programmable prescaler
and DCG
Duty cycle burst generator
Timer 2 mode 1, 2, 3 or 4:
Timer 2 output mode 3:
Figure 69. Carrier Frequency Burst Modulation with the SSI Internal Data Output
DCGO
1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1
Counter 2
Counter = compare register (= 2)
TOG2
SO
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
T2O
Combination Mode 2: Bi-phase Modulation 1
SSI mode 1:
8-bit shift register internal data output (SO) to Timer 2
modulator stage
8-bit compare counter with 4-bit programmable prescaler
The modulator 2 of Timer 2 modulates the SSI internal
data output to Bi-phase-code
Timer 2 mode 1, 2, 3 or 4:
Timer 2 output mode 4:
Figure 70. Bi-phase Modulation 1
TOG2
SC
8-bit SR data
SO
0
0
1
1
0
1
0
Bit 7
T2O
0
1
Bit 0
0
1
1
0
1
0
1
Data: 00110101
68
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Combination Mode 3: Manchester Modulation 1
SSI mode 1:
8-bit shift register internal data output (SO) to Timer 2
modulator stage
8-bit compare counter with 4-bit programmable prescaler
The modulator 2 of Timer 2 modulates the SSI internal
data output to Manchester code
Timer 2 mode 1, 2, 3 or 4:
Timer 2 output mode 5:
Figure 71. Manchester Modulation 1
TOG2
SC
8-bit SR data
0
SO
0
1
1
0
1
0
1
Bit 0
Bit 7
0
T2O
0
1
1
0
1
0
1
Bit 7
Bit 0
Data: 00110101
Combination Mode 4: Manchester Modulation 2
SSI mode 1:
Timer 2 mode 3:
Timer 2 output mode 5:
8-bit shift register internal data output (SO) to Timer 2
modulator stage
8-bit compare counter and 4-bit prescaler
The modulator 2 of Timer 2 modulates the SSI data output
to Manchester code
The 4-bit stage can be used as a prescaler for the SSI to generate the stop signal for
modulator 2. The SSI has a special mode to supply the prescaler with the shift clock.
The control output signal (OMSK) of the SSI is used as a stop signal for the modulator.
Figure 72 shows an example for a 12-bit Manchester telegram.
Figure 72. Manchester Modulation 2
SCLI
Buffer full
SIR
Bit 7 Bit 6
SO
Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
SC
MSM
Timer 2
Mode 3
SCL
Counter 2/1
0
0
0
0
0
Counter 2/1 = Compare Register 2/1 (= 4)
0
0
0
0
1
2
3
4
0
1
2
3
OMSK
T2O
69
4594C–4BMCU–12/04
Combination Mode 5: Bi-phase Modulation 2
SSI mode 1:
Timer 2 mode 3:
Timer 2 output mode 4:
8-bit shift register internal data output (SO) to Timer 2
modulator stage
8-bit compare counter and 4-bit prescaler
The modulator 2 of Timer 2 modulates the SSI data output
to Bi-phase-code
The 4-bit stage can be used as a prescaler for the SSI to generate the stop signal for
modulator 2. The SSI has a special mode to supply the prescaler via the shift clock. The
control output signal (OMSK) of the SSI is used as a stop signal for the modulator. Figure 73 shows an example for a 13-bit Bi-phase telegram.
Figure 73. Bi-phase Modulation 2
SCLI
Buffer full
SIR
Bit 7 Bit 6
SO
Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
SC
MSM
Timer 2
Mode 3
SCL
Counter 2/1
0
0
0
0
0
Counter 2/1 = Compare Register 2/1 (= 5)
0
0
0
0
1
2
3
4
5
0
1
2
OMSK
T2O
70
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Combination Mode Timer 3 and SSI
Figure 74. Combination Timer 3 and SSI
I/O-bus
T3CS
T3M
T3I
SC
T3EX
T3I
CP3
T3CP
T3EX
SYSCL
T1OUT
POUT
CL3
SI
RES
8-bit counter 3
T3C
INT5
T3ST
TOG3
SO
Control
RES
Compare 3/1
Demodulator 3
CM31
Compare 3/2
Timer 3 - control
T3O
Modulator 3
M2
T3CO1
T3CO2
T3CM1
T3CM2
SI
SC
SIC1
TOG2
POUT
T1OUT
SYSCL
SISC
SIC2
Control
INT3
SCLI
SC
SSI-control
MCL_SC
Output
SO
MSB
Shift_CL
SI
8-bit shift register
STB
Transmit buffer
MCL_SD
SI
LSB
SRB
I/O-bus
Receive buffer
Combination Mode 6: FSK Modulation
SSI mode 1:
8-bit shift register internal data output (SO) to Timer 3
Timer 3 mode 8: FSK modulation with shift register data (SO)
The two compare registers are used to generate two varied time intervals. The SSI data
output selects which compare register is used for the output frequency generation. A ‘0’
level at the SSI data output enables the compare register 1 and a ‘1’ level enables the
compare register 2. The compare- and compare mode registers must be programmed to
generate the two frequencies via the output toggle flip flop. The SSI can be supplied with
the toggle signal of Timer 2 or any other clock source. The Timer 3 counter is driven by
an internal or external clock source.
Figure 75. FSK Modulation 1
T3R
0 1 2 3 4 0 1 2 3 4 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 3 4 0 1 2 3 4 0
Counter 3
CM31
CM32
SO
0
1
0
T3O
71
4594C–4BMCU–12/04
Combination Mode 7: Pulse-width Modulation (PWM)
SSI mode 1:
8-bit shift register internal data output (SO) to Timer 3
Timer 3 mode 9: Pulse-width modulation with the shift register data (SO)
The two compare registers are used to generate two varied time intervals. The SSI data
output selects which compare register is used for the output pulse generation. In this
mode, both compare- and compare mode registers must be programmed to generate
the two pulse widths. It is also useful to enable the single-action mode for extreme duty
cycles. Timer 2 is used as baud rate generator and for the triggered restart of Timer 3.
The SSI must be supplied with the toggle signal of Timer 2. The counter is driven by an
internal or external clock source.
Figure 76. Pulse-width Modulation
TOG2
SIR
0
SO
1
0
1
SCO
T3R
Counter 3
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 2 3 4 5 6 7 8 9101112131415 0 1 2 3 4 5 6 7 8 9101112131415 0 1 2 3 4
CM31
CM32
T3O
Combination Mode 8: Manchester Demodulation/Pulse-width Demodulation
SSI mode 1:
8-bit shift register internal data input (SI) and the internal shift clock
(SCI) from Timer 3
Timer 3 mode 10: Manchester demodulation/pulse-width demodulation with Timer 3
For Manchester demodulation, the edge detection stage must be programmed to detect
each edge at the input. These edges are evaluated by the demodulator stage. The timer
stage is used to generate the shift clock for the SSI. A compare register 1 match event
defines the correct moment for shifting the state from the input T3I as the decoded bit
into shift register. After that, the demodulator waits for the next edge to synchronize the
timer by a reset for the next bit. The compare register 2 can be used to detect a time
error and handle it with an interrupt routine.
Before activating the demodulator mode the timer and the demodulator stage must be
synchronized with the bit-stream. The Manchester-code timing consists of parts with the
half bit-length and the complete bit-length. A synchronization routine must start the
demodulator after an interval with the complete bit-length.
The counter can be driven by any internal clock source. The output T3O can be used by
Timer 2 in this mode. The Manchester decoder can also be used for pulse-width demodulation. The input must be programmed to detect the positive edge. The demodulator
and timer must be synchronized with the leading edge of the pulse. After that a counter
match with the compare register 1 shifts the state at the input T3I into the shift register.
The next positive edge at the input restarts the timer.
72
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 77. Manchester Demodulation
Timer 3
mode
T3I
Synchronize
1
Manchester demodulation mode
0
1
1
1
0
0
1
1
0
T3EX
SI
CM31 = SCI
SR-DATA
1
1
1
0
0
1
1
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
0
Bit 0
Combination Mode 9: Bi-phase Demodulation
SSI mode 1:
8-bit shift register internal data input (SI) and the internal shift clock
(SCI) from Timer 3
Timer 3 mode 11: Bi-phase demodulation with Timer 3
In the Bi-phase demodulation mode the timer works like in the Manchester demodulation mode. The difference is that the bits are decoded with the toggle flip-flop. This flipflop samples the edge in the middle of the bit-frame and the compare register 1 match
event shifts the toggle flip-flop output into the shift register. Before activating the demodulation the timer and the demodulation stage must be synchronized with the bit-stream.
The Bi-phase-code timing consists of parts with the half bit-length and the complete
bitlength. The synchronization routine must start the demodulator after an interval with
the complete bit-length.
The counter can be driven by any internal clock source and the output T3O can be used
by Timer 2 in this mode.
Figure 78. Bi-phase Demodulation
Timer 3
mode
T3I
Synchronize
0
Biphase demodulation mode
0
1
1
0
1
0
0
1
T3EX
Q1 = SI
CM31 = SCI
Reset
Counter 3
SR-DATA
0
1
1
0
1
0
1
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
0
Bit 0
73
4594C–4BMCU–12/04
Combination Mode Timer 2 and Timer 3
Figure 79. Combination Timer 3 and Timer 2
I/O-bus
T3CS
T3M
T3I
T3EX
SCI
T3I
T3EX
SYSCL
T1OUT
POUT
CL3
CM31
CP3
T3CP
SI
Demodulator 3
RES
8-bit counter 3
T3C
INT5
T3ST
TOG3
SO
RES
Control
Compare 3/1
Compare 3/2
T3CO1
T3CO2
M2
TOG2
T3CM1
T3O
Modulator 3
Timer 3 - control
T3CM2
I/O-bus
P4CR
T2I
SSI
T2M2
T2M1
DCGO
T2O
TOG3
SYSCL
T1OUT
SCL
CL2/1
CL2/2
4-bit counter 2/1
RES
OVF1
DCG
POUT
OUTPUT
8-bit counter 2/2
RES
OVF2
MOUT
TOG2
Compare 2/1
T2C
Timer 2 - control
M2
Compare 2/2
Bi-phase
Manchester
modulator
INT4
CM1
POUT
T2CO1
I/O-bus
T2CM
T2CO2
SO
Timer 2
modulator 2
output-stage
SSI
SSI
Control
(RE, FE, SCO, OMSK)
Combination Mode 10: Frequency Measurement or Event Counter with Time Gate
Timer 2 mode 1/2:
12-bit compare counter/8-bit compare counter and
4-bit prescaler
Timer 2 output mode 1/6: Timer 2 compare match toggles (TOG2) to Timer 3
Timer 3 mode 3:
Timer/Counter; internal trigger restart and internal capture
(with Timer 2 TOG2-signal)
The counter is driven by an external (T3I) clock source. The output signal (TOG2) of
Timer 2 resets the counter. The counter value before reset is saved in the capture register. If single-action mode is activated for one or both compare registers, the trigger
signal also restarts the single action. This mode can be used for frequency measurements or as event counter with time gate.
74
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 80. Frequency Measurement
T3R
T3I
0 0 1 2 3 4 5 6 7 8 9 10 111213141516 17 0 1 2 3 4 5 6 7 8 9 101112131415161718 0 1 2 3 4 5
Counter 3
TOG2
T3CPRegister
Capture value = 0
Capt. value = 18
Capture value = 17
Figure 81. Event Counter with Time Gate
T3R
T3I
Counter 3
0 0 1 2 3 4 5 6 7 8 910
11
0 1
2
4
3
0 1 2
TOG2
T3CPRegister
Capture value = 11
Capture value = 0
Capture value = 4
Combination Mode 11: Burst Modulation 1
Timer 2 mode 1/2:
12-bit compare counter/8-bit compare counter and
4-bit prescaler
Timer 2 output mode 1/6: Timer 2 compare match toggles the output flip-flop (M2)
to Timer 3
Timer 3 mode 6:
Carrier frequency burst modulation controlled by Timer 2
output (M2)
Timer 3 counter is driven by an internal or external clock source. Its compare- and compare mode registers must be programmed to generate the carrier frequency with the
output toggle flip-flop. The output toggle flip-flop (M2) of Timer 2 is used to enable and
disable Timer 3 output. Timer 2 can be driven by the toggle output signal of Timer 3
(TOG3) or any other clock source.
Figure 82. Burst Modulation 1
CL3
Counter 3
0 1 01 2 34 5 01 0 12 3 4 5 0 10 1 23 4 50 1 01
50 1 01
50 1 01
501 01
5 01 01
501 01
5 0 1 01
5 01 01
501 01
5 01 01
CM1
CM2
TOG3
M3
Counter 2/2
3
0
1
2
3
3
0
1
2
3
TOG2
M2
T3O
75
4594C–4BMCU–12/04
Combination Mode Timer 2, Timer 3 and SSI
Figure 83. Combination Timer 2, Timer 3 and SSI
I/O-bus
T3CS
T3M
T3I
SCI
T3EX
Demodulator 3
T3I
CM31
CP3
T3CP
SI
RES
T3EX
SYSCL
T1OUT
POUT
CL3
8-bit Counter 3
T3C
INT5
T3ST
TOG3
SO
RES
Compare 3/2
T3O
Modulator 3
Control
Compare 3/1
Timer 3 - control
M2
TOG2
T3CO1
T3CO2
T3CM1
T3CM2
SSI
I/O-bus
P4CR
T2M1
T2M2
T2I
DCGO
T2O
TOG3
SYSCL
T1OUT
CL2/1
RES
SCL
T2C
CL2/2
4-bit Counter 2/1
OVF1
DCG
POUT
Compare 2/1
RES
Timer 2 - control
OUTPUT
8-bit Counter 2/2
OVF2
TOG2
MOUT
M2
Compare 2/2
Bi-phase
Manchester
modulator
INT4
CM1
POUT
T2CO1
T2CO2
T2CM
SO
Control
I/O-bus
SIC1
SIC2
(RE, FE,
SCO, OMSK)
SISC
TOG2
POUT
T1OUT
SYSCL
INT3
SCLI
SC
SSI-control
MCL_SC
Output
SO
SI
SCL
Shift_CL
MSB
8-bit shift register
STB
Transmit buffer
76
Timer 2
modulator 2
output-stage
Control
LSB
MCL_SD
SI
SRB
I/O-bus
Receive buffer
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Combination Mode 12: Burst Modulation 2
SSI mode 1:
Timer 2 output mode 2:
Timer 2 output mode 1/6:
Timer 3 mode 7:
8-bit shift register internal data output (SO) to Timer 3
8-bit compare counter and 4-bit prescaler
Timer 2 compare match toggles (TOG2) to the SSI
Carrier frequency burst modulation controlled by the internal
output (SO) of SSI
Timer 3 counter is driven by an internal or external clock source. Its compare- and compare mode registers must be programmed to generate the carrier frequency with the
output toggle flip-flop (M3). The internal data output (SO) of the SSI is used to enable
and disable Timer 3 output. The SSI can by supplied with the toggle signal of Timer 2.
Figure 84. Burst Modulation 2
CL3
Counter 3
0 1 0 1 2 3 4 5 0 1 0 12 3 4 5 0 1 0 1 2 3 4 5 0 1 0 1
5 0 1 01
5 0 1 01
501 01
5 0 1 01
50101
501 01
501 01
501 01
5 0 1 01
CM31
CM32
TOG3
M3
Counter 2/2
3
0
1
2
3
3
0
1
2
3
TOG2
SO
T3O
Combination Mode 13: FSK Modulation
SSI mode 1:
Timer 2 output mode 3:
Timer 2 output mode 1/6:
Timer 3 mode 8:
8-bit shift register internal data output (SO) to Timer 3
8-bit compare counter and 4-bit prescaler
Timer 2 4-bit compare match signal (POUT) to the SSI
FSK modulation with shift register data output (SO)
The two compare registers are used to generate two different time intervals. The SSI
data output selects which compare register is used for the output frequency generation.
A ‘0’ level at the SSI data output enables the compare register 1 and a ‘1’ level enables
the compare register 2. The compare- and compare mode registers must be programmed to generate the two frequencies via the output toggle flip-flop. The SSI can be
supplied with the toggle signal of Timer 2 or any other clock source. Timer 3 counter is
driven by an internal or external clock source.
77
4594C–4BMCU–12/04
Figure 85. FSK Modulation
T3R
0 1 2 3 4 0 1 2 3 4 0 1 2 3 4 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 3 4 0 1
Counter 3
CM31
CM32
SO
0
1
0
T3O
ATAR092-D
The ATAR092-D is a multi-chip device which offers a combination of a MARC4-based
microcontroller and a serial E2PROM data memory in a single package.
The ATAR092-D is used as a microcontroller and the U505M as serial E2PROM. Two
internal lines can be used as chip-to-chip link in a single package. The maximum internal data communication frequency between the ATAR092-D and the U505M over the
chip link (MCL_SC and MCL_SD) is fSC_MCL = 500 kHz.
The microcontroller and the EEPROM portions of this multi-chip device are equivalent to
their respective individual component chips, except for the electrical specification.
Internal 2-wire Multi-chip
Link
Two additional on-chip pads (MCL_SC and MCL_SD) for the SC and the SD lines can
be used as chip-to-chip links for multi-chip applications. These pads can be activated by
setting the MCL bit in the SISC register.
Figure 86. Multi-chip Link
U505M
SCL
SDA
Multi-chip link
MCL_SC
MCL_SD
VDD
VSS
BP43/SD
BP40/SC
BP10
78
ATAR092-D
BP13
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Absolute Maximum Ratings
Voltages are given relative to VSS.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating
only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this
specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
All inputs and outputs are protected against high electrostatic voltages or electric fields. However, precautions to minimize the build-up of
electrostatic charges during handling are recommended. Reliability of operation is enhanced if unused inputs are connected to an
appropriate logic voltage level (e.g., VDD).
Parameters
Symbol
Value
Unit
Supply voltage
VDD
-0.3 to +6.5
V
Input voltage (on any pin)
VIN
VSS -0.3 ≤VIN ≤VDD +0.3
V
Output short circuit duration
tshort
indefinite
s
Operating temperature range
Tamb
-40 to +125
°C
Storage temperature range
Tstg
-40 to +130
°C
Soldering temperature (t ≤10 s)
Tsld
260
°C
Symbol
Value
Unit
RthJA
140
K/W
Thermal Resistance
Parameter
Thermal resistance (SSO20)
DC Operating Characteristics
VSS = 0 V, Tamb = -40°C to +125°C unless otherwise specified.
Parameters
Test Conditions
Symbol
Min.
VDD
VPOR
Typ.
Max.
Unit
6.5
V
400
µA
µA
µA
Power Supply
Operating voltage at VDD
Active current
CPU active
fSYSCL = 1 MHz
VDD = 1.8 V
VDD = 3.0 V
VDD = 6.5 V
IDD
Power down current
(CPU sleep,
RC oscillator active,
4-MHz quartz oscillator active)
fSYSCL = 1 MHz
VDD = 1.8 V
VDD = 3.0 V
VDD = 6.5 V
IPD
Sleep current (CPU sleep,
32-kHz quartz oscillator active
4-MHz quartz oscillator inactive)
VDD = 1.8 V
VDD = 3.0 V
VDD = 6.5 V
ISleep
0.4
0.6
0.8
2.3
4.8
µA
µA
µA
Sleep current (CPU sleep,
32-kHz quartz oscillator inactive
4-MHz quartz oscillator inactive)
VDD = 1.8 V
VDD = 3.0 V
VDD = 6.5 V
ISleep
0.1
0.3
0.5
1.5
4.0
µA
µA
µA
Pin capacitance
Any pin to VSS
CL
7
10
pF
200
300
700
40
70
200
180
µA
µA
µA
79
4594C–4BMCU–12/04
DC Operating Characteristics (Continued)
VSS = 0 V, Tamb = -40°C to +125°C unless otherwise specified.
Parameters
Test Conditions
Symbol
Min.
Typ.
Max.
Unit
Power-on Reset Threshold Voltage
POR threshold voltage
BOT = 1
VPOR
1.6
1.7
1.8
V
POR threshold voltage
BOT = 0
VPOR
1.85
2.0
2.15
V
POR hysteresis
VPOR
50
3.0
mV
Voltage Monitor Threshold Voltage
VM high threshold voltage
VDD > VM, VMS = 1
VMThh
VM high threshold voltage
VDD < VM, VMS = 0
VMThh
VM middle threshold voltage
VDD > VM, VMS = 1
VMThm
VM middle threshold voltage
VDD < VM, VMS = 0
VMThm
VM low threshold voltage
VDD > VM, VMS = 1
VMThl
VM low threshold voltage
VDD < VM, VMS = 0
VMThl
VMI
VDD = 3 V, VMS = 1
VVMI
VMI
VDD = 3 V, VMS = 0
2.75
3.0
2.6
2.36
3.25
V
2.8
V
2.4
V
2.6
2.2
1.97
2.2
VVMI
1.2
1.3
V
V
V
External Input Voltage
1.3
1.4
V
V
All Bi-directional Ports
Input voltage LOW
VDD = 1.8 to 6.5 V
VIL
VSS
0.2 ×
VDD
V
Input voltage HIGH
VDD = 1.8 to 6.5 V
VIH
0.8 ×
VDD
VDD
V
Input LOW current
(switched pull-up)
VDD = 2.0 V,
VDD = 3.0 V, VIL= VSS
VDD = 6.5 V
IIL
-1.4
-7
-50
-4
-20
-100
-12
-40
-200
µA
µA
µA
Input HIGH current
(switched pull-down)
VDD = 2.0 V,
VDD = 3.0 V, VIH = VDD
VDD = 6.5 V
IIH
1.4
7
50
4
20
100
12
40
200
µA
µA
µA
Input LOW current
(static pull-up)
VDD = 2.0 V
VDD = 3.0 V, VIL= VSS
VDD = 6.5 V
IIL
-14
-60
-300
-50
-160
-600
-100
-320
-1200
µA
µA
µA
Input LOW current
(static pull-down)
VDD = 2.0 V
VDD = 3.0 V, VIH= VDD
VDD = 6.5 V
IIH
14
60
300
50
160
600
100
320
1200
µA
µA
µA
Input leakage current
VIL= VSS
IIL
100
nA
Input leakage current
VIH= VDD
IIH
100
nA
Output LOW current
VOL = 0.2 × VDD
VDD = 2.0 V
VDD = 3.0 V
VDD = 6.5 V
Output HIGH current
VOH = 0.8 × VDD
VDD = 2.0 V
VDD = 3.0 V
VDD = 6.5 V
Note:
80
IOL
0.5
2
8
1.2
5
15
2.5
8
22
mA
mA
mA
IOH
-0.5
-2
-8
-1.2
-5
-16
-2.5
-8
-24
mA
mA
mA
The Pin BP20/NTE has a static pull-up resistor during the reset-phase of the microcontroller
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
AC Characteristics
Supply voltage VDD = 1.8 V to 6.5 V, VSS = 0 V, Tamb = 25°C unless otherwise specified.
Parameters
Test Conditions
Symbol
Min.
VDD = 1.8 to 6.5 V
Tamb = -40 to +125° C
tSYSCL
VDD = 2.4 to 6.5 V
Tamb = -40 to +125° C
tSYSCL
Typ.
Max.
Unit
500
4000
ns
250
4000
ns
5
MHz
Operation Cycle Time
System clock cycle
Timer 2 Input Timing Pin T2I
Timer 2 input clock
fT2I
Timer 2 input LOW time
Rise/fall time < 10 ns
tT2IL
100
ns
Timer 2 input HIGH time
Rise/fall time < 10 ns
tT2IH
100
ns
Timer 3 Input Timing Pin T3I
Timer 3 input clock
Timer 3 input LOW time
Timer 3 input HIGH time
SYSCL/2
fT3I
Rise/fall time < 10 ns
Rise/fall time < 10 ns
tT3IL
tT3IH
2 × tSYSC
MHz
ns
L
2 × tSYSC
ns
L
Interrupt Request Input Timing
tIRL
100
ns
Rise/fall time < 10 ns
tIRH
100
ns
EXSCL at OSC1, ECM = EN
Rise/fall time < 10 ns
fEXSCL
0.5
4
MHz
EXSCL at OSC1, ECM = DI
Rise/fall time < 10 ns
fEXSCL
0.02
4
MHz
tIH
0.1
Interrupt request LOW time
Interrupt request HIGH time
Rise/fall time < 10 ns
External System Clock
Input HIGH time
Rise/fall time < 10 ns
µs
Reset Timing
Power-on reset time
VDD > VPOR
tPOR
1.5
fRcOut1
3.8
5
ms
RC Oscillator 1
Frequency
Stability
VDD = 2.0 to 6.5 V
Tamb = -40°C to +125° C
∆f/f
MHz
±50
%
RC Oscillator 2 – External Resistor
Frequency
Rext = 170 kΩ
Stability
VDD = 2.0 to 6.5 V
Tamb = -40°C to +125° C
Stabilization time
fRcOut2
4
MHz
∆f/f
±15
%
tS
10
µs
4-MHz Crystal Oscillator (Operating Range VDD = 2.2 V to 6.5 V)
Frequency
fX
4
MHz
Start-up time
tSQ
5
ms
Stability
∆f/f
-10
10
ppm
CIN
COUT
0
0
20
20
pF
pF
Integrated input/output capacitances
(mask programmable)
CIN/COUT programmable in steps of
0.63 nF
81
4594C–4BMCU–12/04
AC Characteristics (Continued)
Supply voltage VDD = 1.8 V to 6.5 V, VSS = 0 V, Tamb = 25°C unless otherwise specified.
Parameters
Test Conditions
Symbol
Min.
Typ.
Max.
Unit
32-kHz Crystal Oscillator (Operating Range VDD = 2.0 V to 6.5 V)
Frequency
fX
32.768
kHz
Start-up time
tSQ
0.5
s
Stability
∆f/f
-10
10
ppm
CIN
COUT
0
0
20
20
pF
pF
CIN/COUT programmable in steps of
2 pF
Integrated input/output capacitances
(mask programmable)
External 32-kHz Crystal Parameters
Crystal frequency
fX
32.768
kHz
Serial resistance
RS
30
Static capacitance
C0
1.5
pF
Dynamic capacitance
C1
3
fF
Crystal frequency
fX
4.0
MHz
Serial resistance
RS
40
150
Ω
Static capacitance
C0
1.4
3
pF
Dynamic capacitance
C1
3
50
kΩ
External 4-MHz Crystal Parameters
fF
Recommendations for the 32-kHz Crystal Oscillator
Recommended Parameters for 32-kHz Crystals (for example MicroCrystal MS1V, Daishinku SM-14J)
Series Resistance
Load Capacitance
Maximum Load Capacitance
RSmax = 35 kΩ
8 pF < CL, eff > 10 pF
12 pF
RSmax = 50 kΩ
7 pF < CL, eff > 9 pF
10 pF
RSmax = 70 kΩ, typically 50 kΩ
6 pF < CL, eff > 7 pF
8 pF
Recommended Values for Integrated Input/Output Capacitances (Mask Option)
CL, eff (pF)
6
7
8
9
10
11
12
Copt (pF)
3.8
5.6
7.5
10
11.9
13.8
15.6
CL, eff: Effective load capacitance of the crystal for the nominal frequency of 32678 Hz
Copt: Recommended value for the integrated capacitance to meet, together with the parasitic pin capacitance, the
related CL,eff.
Crystal Characteristics
Figure 87. Crystal Equivalent Circuit
L
C1
Equivalent
circuit
OSCIN
SCLIN
RS
OSCOUT
SCLOUT
C0
82
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 88. Active Supply Current versus Frequency
2.5
Tamb = -25°C
VDD = 6.5 V
2.0
IDDact (mA)
5V
1.5
3V
1.0
2V
0.5
0.0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
fSYSCLK (MHz)
Figure 89. Active Supply Current versus VDD
0.8
0.7
fSYSCLK = 1 MHz
Tamb = 125°C
85°C
IDDact (mA)
0.6
-40°C
0.5
0.4
25°C
0.3
0.2
0.1
0.0
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
VDD (V)
Figure 90. Power-down Supply Current versus Frequency
400
350
Tamb = -25°C
VDD = 6.5 V
300
IPD (µA)
250
5V
200
4V
150
3V
100
2V
50
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
fSYSCLK (MHz)
83
4594C–4BMCU–12/04
Figure 91. Power-down Supply Current versus VDD
120
100
fSYSCLK = 500 kHz
Tamb = 25°C
IPD (µA)
80
60
40
20
0
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
VDD (V)
Figure 92. Sleep Current versus Tamb
1.0
0.9
IDDsleep (µA)
0.8
0.7
0.6
0.5
VDD = 6.5 V
0.4
0.3
5V
0.2
3V
0.1
0.0
-40
-20
0
20
40
60
80
100
120
140
Tamb (°C)
Figure 93. Internal RC Frequency versus VDD
fRC_INT (MHz)
5.0
4.5
Tamb = -40°C
4.0
25°C
85°C
3.5
125°C
3.0
2.5
2.0
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
VDD (V)
84
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 94. Internal RC Frequency versus Tamb
5.0
fRC_INT (MHz)
4.5
4.0
VDD = 6.5 V
3.5
3V
2V
3.0
2.5
2.0
-40
-20
0
20
40
60
80
100
120
140
6.0
6.5
Tamb (°C)
Figure 95. External RC Frequency versus VDD
4.6
Rext = 170 kΩ
fRC_EXT (MHz)
4.4
4.2
Tamb = -40°C
25°C
4.0
3.8
125°C
85°C
3.6
3.4
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
VDD (V)
Figure 96. External RC Frequency versus Tamb
4.6
Rext = 170 kΩ
fRC_EXT (MHz)
4.4
4.2
VDD = 6.5 V
4.0
3V
3.8
2V
3.6
3.4
-40
-20
0
20
40
60
80
100
120
140
Tamb (°C)
85
4594C–4BMCU–12/04
Figure 97. System Clock versus VDD
10.00
SYSCLKmax
fSYSCLK (MHz)
1.00
SYSCLKmin
0.10
0.01
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
VDD (V)
Figure 98. External RC Frequency versus Rext
8.0
Tamb = 25°C
7.0
VDD = 3 V
fRC_EXT (MHz)
6.0
5.0
4.0
max.
3.0
typ.
2.0
min.
1.0
100
150
200
250
300
350
400
Rext (kΩ)
Figure 99. Pull-up Resistor versus VDD
1000
RPU (kΩ)
VIL = VSS
Tamb = 125°C
85°C
100
25°C
10
2.0
2.5
3.0
3.5
4.0
-40°C
4.5
5.0
5.5
6.0
6.5
VDD (V)
86
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 100. Pull-down Resistor versus VDD
1000
RPU (kΩ)
VIH = VDD
Tamb = 125°C
85°C
100
-40°C
25°C
10
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
5.0
5.5
6.0
6.5
5.5
6.0
6.5
VDD (V)
Figure 101. Strong Pull-up Resistor versus VDD
100
RSPU (kΩ)
VIL = VSS
Tamb = 125°C
85°C
25°C
-40°C
10
2.0
2.5
3.0
3.5
4.0
4.5
VDD (V)
Figure 102. Strong Pull-down Resistor versus VDD
100
RSPD (kΩ)
VIH = VDD
Tamb = 125°C
85°C
25°C
-40°C
10
2.0
2.5
3.0
3.5
4.0
4.5
5.0
VDD (V)
87
4594C–4BMCU–12/04
Figure 103. Output High Current versus VDD – Output High Voltage
0
VDD = 2.0 V
-5
-10
3.0 V
IOH (mA)
-15
4.0 V
-20
5.0 V
-25
Tamb = 25°C
-30
6.5 V
-35
-40
0.0
0.5
1.0
1.5 2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
6.0
6.5
VDD - VOH (V)
Figure 104. Output Low Current versus Output Low Voltage
30
Tamb = 25°C
VDD = 6.5 V
25
20
IOL (mA)
5.0 V
15
4.0 V
10
3.0 V
5
2.0 V
0
0.0
0.5
1.0
1.5 2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
VOL (V)
Figure 105. Output High Current versus Tamb, VDD = 6.5 V, VOH = 0.8 × VDD
0
IOH (mA)
-5
min.
-10
typ.
-15
max.
-20
-25
-40
-20
0
20
40
60
80
100
120
140
Tamb (°C)
88
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Figure 106. Output Low Current versus Tamb, VDD = 6.5 V, VOL = 0.2 × VDD
25
IOL (mA)
20
max.
15
typ.
10
min.
5
0
-40
-20
0
20
40
60
80
100
120
140
Tamb (°C)
89
4594C–4BMCU–12/04
Emulation
The basic function of emulation is to test and evaluate the customer's program and
hardware in real time. This therefore enables the analysis of any timing, hardware or
software problem. For emulation purposes, all MARC4 controllers include a special
emulation mode. In this mode, the internal CPU core is inactive and the I/O buses are
available via Port 0 and Port 1 to allow an external access to the on-chip peripherals.
The MARC4 emulator uses this mode to control the peripherals of any MARC4 controller (target chip) and emulates the lost ports for the application.
The MARC4 emulator can stop and restart a program at specified points during execution, making it possible for the applications engineer to view the memory contents and
those of various registers during program execution. The designer also gains the ability
to analyze the executed instruction sequences and all the I/O activities.
Figure 107. MARC4 Emulation
Emulator target board
MARC4 emulator
MARC4
emulation-CPU
MARC4 target chip
I/O bus
Port 0
Program
memory
I/O control
Port 1
CORE
Trace
memory
CORE
(inactive)
Peripherals
Port 0
Control
logic
Port 1
Emulation control
SYSCL/
TCL,
TE, NRST
Application-specific hardware
Personal computer
90
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Option Settings for Ordering
[ ] ATAR092-D
(-40°C to +125°C)
Please select the option settings from the list below and insert ROM CRC.
Output(1)
Input
Port 1
Output
Input
Port 5
BP10 [
]
CMOS
[
]
Switched pull-up
BP50 [
]
CMOS
[
]
Switched pull-up
[
]
Open drain [N]
[
]
Switched pull-down
[
]
Open drain [N]
[
]
Switched pull-down
[
]
Open drain [P]
[
]
Open drain [P]
[
]
Static pull-up
[
]
Static pull-down
[
]
Static pull-up
[
]
Static pull-down
BP13 [
]
CMOS
[
]
Switched pull-up
BP51 [
]
CMOS
[
]
Switched pull-up
[
]
Open drain [N]
[
]
Switched pull-down
[
]
Open drain [N]
[
]
Switched pull-down
[
]
Open drain [P]
[
]
Open drain [P]
[
]
Static pull-up
[
]
Static pull-down
BP52 [
]
CMOS
[
]
Switched pull-up
[
]
Switched pull-up
[
]
Open drain [N]
[
]
Switched pull-down
[
]
Open drain [P]
Port 2
[
]
Static pull-up
[
]
Static pull-down
BP20(2) [
]
CMOS
[
]
Open drain [N]
[
]
Switched pull-down
[
]
Open drain [P]
[
]
Static pull-up
[
]
Static pull-down
BP53 [
]
CMOS
[
]
Switched pull-up
BP21 [
]
CMOS
[
]
Switched pull-up
[
]
Open drain [N]
[
]
Switched pull-down
[
]
Open drain [N]
[
]
Switched pull-down
[
]
Open drain [P]
[
]
Open drain [P]
[
]
Static pull-up
[
]
Static pull-down
BP22 [
]
CMOS
[
]
Switched pull-up
BP60 [
]
CMOS
[
]
Switched pull-up
[
]
Open drain [N]
[
]
Switched pull-down
[
]
Open drain [N]
[
]
Switched pull-down
[
]
Open drain [P]
[
]
Open drain [P]
[
]
Static pull-up
[
]
Static pull-down
[
]
Static pull-up
[
]
Static pull-down
[
]
Static pull-up
[
]
Static pull-down
Port 6
[
]
Static pull-up
[
]
Static pull-down
BP23 [
]
CMOS
[
]
Switched pull-up
BP63 [
]
CMOS
[
]
Switched pull-up
[
]
Open drain [N]
[
]
Switched pull-down
[
]
Open drain [N]
[
]
Switched pull-down
[
]
Open drain [P]
[
]
Open drain [P]
[
]
Static pull-up
[
]
Static pull-down
[
]
Static pull-up
[
]
Static pull-down
Port 4
BP40 [
]
CMOS
[
]
Switched pull-up
[
]
Open drain [N]
[
]
Switched pull-down
[
]
No integrated capacitance
[
]
Open drain [P]
[
]
Static pull-up
[
]
Internal capacitance (0 to 20 pF) [ _____pF]
[
]
Static pull-down
BP41 [
]
CMOS
[
]
Switched pull-up
[
]
No integrated capacitance
[
]
Open drain [N]
[
]
Switched pull-down
[
]
Internal capacitance (0 to 20 pF) [ _____pF]
[
]
Open drain [P]
[
]
Static pull-up
[
]
Static pull-down
OSC1
OSC2
[
]
External resistor
BP42 [
]
CMOS
[
]
Switched pull-up
Clock Used
[
]
External clock OSC1
[
]
Open drain [N]
[
]
Switched pull-down
[
]
External clock OSC2
[
]
Open drain [P]
[
]
Static pull-up
[
]
32-kHz crystal
[
]
Static pull-down
[
]
4-MHz crystal
BP43 [
]
CMOS
[
]
Switched pull-up
[
]
Open drain [N]
[
]
Switched pull-down
[
]
Open drain [P]
[
]
Static pull-up
ECM (External Clock Monitor)
[
]
Enable
[
]
Static pull-down
[
]
Disable
Please attach this page to the approval form.
Filename: ___________________________ .HEX
Date: ____________
Notes:
CRC: ___________________________ (HEX)
Signature: _________________________ Company: _________________________
1. It is required to select an output option for each port pin (Port 1, Port 2, Port 4, Port 5, Port 6).
2. Don’t use external components at BP20 that pull to VSS during reset representing a resistor < 150k.
91
4594C–4BMCU–12/04
Ordering Information
Extended Type Number
Program Memory
Data-EEPROM
Package
ATAR092x-yyy-TKQYz
4 kB ROM
No
SSO20
Taped and reeled
ATAR092x-yyy-TKSYz
4 kB ROM
No
SSO20
Tubes
Note:
Delivery
1. x = Hardware revision
yyy = Customer specific ROM-version
z = Operating temperature range
= D (-40°C to +125°C)
Y = Lead-free
Package Information
5.7
5.3
Package SSO20
Dimensions in mm
6.75
6.50
4.5
4.3
1.30
0.15
0.05
0.25
0.65
5.85
20
0.15
6.6
6.3
11
technical drawings
according to DIN
specifications
1
92
10
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
Revision History
Please note that the referring page numbers in this section are referred to the specific
revision mentioned, not to this document.
Changes from Rev.
4594A - 03/03 to Rev.
4594B - 05/04
1. Put datasheet in a new template.
2. Rename ATAR092-D in ATAR092-J.
3. Features on page 1 changed.
4. Table 1 “Available Variants of ATAxx9x on page 3 changed.
5. Table 10 “Pheripheral Addresses” on page 21 changed.
6. Section “Timer 2” on page 33 changed.
7. Table 20 “Timer 2 Output Select Bits” on page 42 changed”.
8. Figure 44 “Timer 3” on page 44 changed.
9. New heading rows at Table “Absolute Maximum Ratings” on page 79 added.
10. System clock cycle in Table “AC Characteristics” on page 81 changed.
11. Section “Emulation” on page 90 added.
12. Table name on page 91 changed.
13. Table “Ordering Information” on page 92 added.
Changes from Rev.
4594B - 05/04 to Rev.
4594C - 12/04
1. Put datasheet in a new template.
2. Rename ATAR092-J in ATAR092-D.
3. Lead-free Logo on page 1 added.
4. Section “ROM” on page 4 changed.
5. Section “4-MHz” Oscillator on pages 16-17 changed.
6. Section “32-kHz Oscillator” on page 17 changed.
7. Table “Option Settings for Ordering” on page 91 changed.
8. Table “Ordering Information” on page 92 changed.
93
4594C–4BMCU–12/04
Table of Contents
Features................................................................................................. 1
Description ............................................................................................ 1
Pin Configuration.................................................................................. 2
Pin Description ..................................................................................... 2
Introduction........................................................................................... 3
MARC4 Architecture............................................................................. 3
General Description .............................................................................................. 3
Components of MARC4 Core ............................................................................... 4
ROM ................................................................................................................4
RAM ................................................................................................................4
Registers .........................................................................................................5
ALU .................................................................................................................6
I/O Bus ............................................................................................................7
Instruction Set .................................................................................................7
Interrupt Structure ...........................................................................................7
Master Reset ........................................................................................................ 9
Power-on Reset and Brown-out Detection ....................................................10
Watchdog Reset ...........................................................................................11
External Clock Supervisor .............................................................................11
Voltage Monitor................................................................................................... 11
Voltage Monitor Control/Status Register .......................................................12
Clock Generation ................................................................................................ 13
Clock Module ................................................................................................13
Oscillator Circuits and External Clock Input Stage .......................................15
Clock Management .......................................................................................17
Power-down Modes ............................................................................................ 19
Peripheral Modules............................................................................. 20
Addressing Peripherals....................................................................................... 20
Bi-directional Ports.............................................................................................. 22
Bi-directional Port 1 .......................................................................................22
Bi-directional Port 2 .......................................................................................23
Bi-directional Port 5 .......................................................................................24
Bi-directional Port 4 .......................................................................................27
Bi-directional Port 6 .......................................................................................28
Universal Timer/Counter/ Communication Module (UTCM) ............................... 29
Timer 1 ..........................................................................................................30
Timer 2 ..........................................................................................................33
Timer 3 ..........................................................................................................44
Synchronous Serial Interface (SSI) ...............................................................56
Combination Modes ......................................................................................67
94
ATAR092-D
4594C–4BMCU–12/04
ATAR092-D
ATAR092-D .......................................................................................... 78
Internal 2-wire Multi-chip Link ............................................................................. 78
Absolute Maximum Ratings............................................................... 79
Thermal Resistance............................................................................ 79
DC Operating Characteristics............................................................ 79
AC Characteristics.............................................................................. 81
Option Settings for Ordering ............................................................. 91
Ordering Information.......................................................................... 92
Package Information .......................................................................... 92
Revision History ................................................................................. 93
95
4594C–4BMCU–12/04
Atmel Corporation
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 487-2600
Regional Headquarters
Europe
Atmel Sarl
Route des Arsenaux 41
Case Postale 80
CH-1705 Fribourg
Switzerland
Tel: (41) 26-426-5555
Fax: (41) 26-426-5500
Asia
Room 1219
Chinachem Golden Plaza
77 Mody Road Tsimshatsui
East Kowloon
Hong Kong
Tel: (852) 2721-9778
Fax: (852) 2722-1369
Japan
9F, Tonetsu Shinkawa Bldg.
1-24-8 Shinkawa
Chuo-ku, Tokyo 104-0033
Japan
Tel: (81) 3-3523-3551
Fax: (81) 3-3523-7581
Atmel Operations
Memory
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 436-4314
RF/Automotive
Theresienstrasse 2
Postfach 3535
74025 Heilbronn, Germany
Tel: (49) 71-31-67-0
Fax: (49) 71-31-67-2340
Microcontrollers
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 436-4314
La Chantrerie
BP 70602
44306 Nantes Cedex 3, France
Tel: (33) 2-40-18-18-18
Fax: (33) 2-40-18-19-60
ASIC/ASSP/Smart Cards
1150 East Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906, USA
Tel: 1(719) 576-3300
Fax: 1(719) 540-1759
Biometrics/Imaging/Hi-Rel MPU/
High Speed Converters/RF Datacom
Avenue de Rochepleine
BP 123
38521 Saint-Egreve Cedex, France
Tel: (33) 4-76-58-30-00
Fax: (33) 4-76-58-34-80
Zone Industrielle
13106 Rousset Cedex, France
Tel: (33) 4-42-53-60-00
Fax: (33) 4-42-53-60-01
1150 East Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906, USA
Tel: 1(719) 576-3300
Fax: 1(719) 540-1759
Scottish Enterprise Technology Park
Maxwell Building
East Kilbride G75 0QR, Scotland
Tel: (44) 1355-803-000
Fax: (44) 1355-242-743
Literature Requests
www.atmel.com/literature
Disclaimer: The information in this document is provided in connection with Atmel products. No license, express or implied, by estoppel or otherwise, to any
intellectual property right is granted by this document or in connection with the sale of Atmel products. EXCEPT AS SET FORTH IN ATMEL’S TERMS AND CONDITIONS OF SALE LOCATED ON ATMEL’S WEB SITE, ATMEL ASSUMES NO LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED OR STATUTORY
WARRANTY RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE, OR NON-INFRINGEMENT. IN NO EVENT SHALL ATMEL BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL OR INCIDENTAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION, OR LOSS OF INFORMATION) ARISING OUT
OF THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF ATMEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Atmel makes no
representations or warranties with respect to the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications
and product descriptions at any time without notice. Atmel does not make any commitment to update the information contained herein. Atmel’s products are not
intended, authorized, or warranted for use as components in applications intended to support or sustain life.
© Atmel Corporation 2004. All rights reserved. Atmel®, logo and combinations thereof are registered trademarks, and Everywhere You Are ™
are the trademarks of Atmel Corporation or its subsidiaries. Other terms and product names may be trademarks of others.
Printed on recycled paper.
4594C–4BMCU–12/04