UVQ Series www.murata-ps.com Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters ORDERING GUIDE SUMMARY Model VOUT Range IOUT Range VIN Range Efficiency All Models 1.2V to 48V 2.5A to 40A 18-36V or 36-75V Up to 92.%, model dependent INPUT CHARACTERISTICS Parameter Typ. @ 25°C, full load Voltage Range Typical unit Notes 18-36 or 36-75 Volts 24V or 48V nominal Current, full power Up to 5.6 Amps Model dependent Isolation 2kVdc to 2250V Model dependent Remote On/Off Control Switch or FET control Positive or negative logic FEATURES OUTPUT CHARACTERISTICS ■ Standard quarter-brick package/pinout Parameter ■ Outputs from 1.5 to 48V up to 125W Voltage ■ Typ. @ 25°C, full load 1.5 to 48 Volts ±10% Notes Trimmable Low profile 0.42" height Current 2.5 to 40 Amps fullscale No minimum load ■ 24 and 48Vdc nominal inputs Accuracy Down to 1% of VNOM Most models ■ Fully isolated, 2250Vdc (BASIC) insulation Ripple & Noise (to 20MHz) Down to 35mVp-p Model dependent Line and Load Regulation Down to ±0.125%/±0.25% Model dependent Overcurrent Protection 150% of IOUT max. With hiccup auto-restart Overtemperature Protection +125°C Efficiency (minimum) See Performance Specifications ■ Designed for RoHS compliance ■ Output overvoltage/short-circuit protected ■ On/Off control, trim and sense functions ■ High efficiency to 92% ■ Protected against temp. and voltage limits GENERAL SPECIFICATIONS ■ Designed to meet UL/IEC/EN60950-1 safety approvals Parameter Typ. @ 25°C, full load Dynamic Load Response Down to 50μsec Notes Model dependent Operating Temperature Range –40 to +110°C With baseplate, see derating curve Safety UL/IEC/EN 60950-1 and CSA C22.2-No.234 MECHANICAL CHARACTERISTICS With baseplate 1.45 x 2.30 x 0.5 inches (36.83 x 58.42 x 12.7 mm) Without baseplate 1.45 x 2.30 x 0.42 inches (36.83 x 58.42 x 10.67 mm) See Performance Specifications, page 2 PRODUCT OVERVIEW For efficient, fully isolated DC power in the smallest space, Murata Power Solutions' UVQ series quarter bricks offer output voltages from 1.5 to 48 Volts with currents up to 40 Amps. UVQs operate over a wide temperature range (up to +70°C at 200 lfm airflow) at full-rated power. The optional mounting baseplate extends this to all practical temperature ranges at full power. UVQ’s achieve these impressive specifications while delivering excellent electrical performance. Overall noise is 35mVp-p (3.3V models) with fast step response (down to 50μsec). These converters For full details go to www.murata-ps.com/rohs offer high stability even with no load and tight output regulation. The unit is fully protected against input over and undervoltage, output overcurrent and short circuit. An on-board temperature sensor shuts down the converter if thermal limits are reached. Protection uses the “hiccup” (auto restart) method. A convenient remote On/Off control input operates by external digital logic, relay or transistor input. To compensate for longer wiring and to retain output voltage accuracy at the load, UVQ’s include a Sense input to dynamically correct for ohmic losses. A trim input may be connected to a user’s adjustment potentiometer or trim resistors for output voltage calibration closer than the standard accuracy. UVQ’s include industry-standard safety certifications and BASIC I/O insulation provides 2250 Volt input/output isolation. Radiation emission testing is performed to widely-accepted EMC standards. The UVQ’s may be considered as higher performance replacements for some MPS USQ models. Pb Lead-free construction/attach www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 1 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters Performance Specifications and Ordering Guide ➀ ORDERING GUIDE Output Root Models VOUT (Volts) UVQ-1.5/40-D24P-C UVQ-2.5/35-D24P-C UVQ-2.5/40-D48N-C UVQ-3.3/30-D24P-C UVQ-3.3/35-D48N-C UVQ-5/20-D24P-C UVQ-5/20-D48N-C UVQ-12/8-D24P-C UVQ-12/10-D48N-C UVQ-15/7-D24P-C UVQ-15/7-D48N-C UVQ-18/5.6-D24P-C UVQ-18/6-D48N-C UVQ-24/4.5-D24P-C UVQ-24/4.5-D48N-C UVQ-48/2.5-D24P-C UVQ-48/2.5-D48N-C 1.5 IOUT Power (Amps) (Watts) 40 35 40 30 35 60 87.5 100 99 115.5 5 20 100 12 8 10 96 120 15 7 105 18 5.6 6 100.8 24 4.5 48 2.5 2.5 3.3 108 120 Input R/N (mVp-p) ➁ Regulation (Max.) ➂ Typ. Max. Line Load VIN Nom. (Volts) 30 60 60 60 65 40 50 25 130 160 150 150 185 185 100 130 200 375 ±0.075% ±0.05% ±0.05% ±0.1% ±0.05% ±0.05% ±0.05% ±0.1% ±0.075% ±0.05% ±0.05% ±0.05% ±0.05% ±0.075% ±0.075% ±0.1% ±0.175% ±0.05% ±0.05% ±0.05% ±0.25% ±0.25% ±0.05% ±0.05% ±0.1% ±0.05% ±0.05% ±0.02% ±0.075% ±0.075% ±0.15% ±0.25% ±0.2% ±0.2% 24 24 48 24 48 24 48 24 48 24 48 24 48 24 48 24 48 35 30 20 95 110 85 120 125 125 60 75 100 250 c These are partial model numbers. Please refer to the full model number structure for complete ordering part numbers. d Min. IOUT = 3 Amps. e All specifications are at nominal line voltage and full load, +25°C unless otherwise noted. See detailed specifications. UVQ Pin 9 Baseplate Connection The UVQ series may include an optional installed baseplate for extended thermal management. Various UVQ models (see list below) are also available with an additional pin 9 on special order which connects to the baseplate but is electrically isolated from the rest of the converter. Please refer to the mechanical drawings. Pin 9 offers a positive method of controlling the electrical potential of the baseplate, independent of the converter. Some baseplate models cannot include pin 9 and in such cases, the baseplate is grounded by the mounting bolts. Or consider adding an external lugged washer with a grounding terminal. The baseplate may be ordered by adding a “B” to the model number tree and pin 9 will be pre-installed by adding a “9”. The two options are separate. Please refer to the Ordering Guide. Do not order pin 9 without the baseplate. Note that “pin 9” converters may be on limited forecast, requiring minimum order quantities and scheduled deliveries. www.murata-ps.com Range IIN, No Load IIN, Full Load (Volts) (mA) (Amps) 18-36 18-36 36-75 18-36 36-75 18-36 36-75 18-36 36-75 18-36 36-75 18-36 36-75 18-36 36-75 18-36 36-75 80 100 100 180 130 180 80 90 60 103 60 140 80 45 45 45 30 2.84 4.14 2.37 4.58 2.7 4.53 2.31 4.4 2.78 4.85 2.39 4.69 2.5 5.03 2.49 4.4 2.71 Efficiency) Min. Typ. 86.5% 86% 87% 88.5% 87% 91% 88.5% 89% 88.5% 88.5% 90% 88% 88.3% 88% 89% 89% 91% 88% 88% 88% 90% 89% 92% 90% 91% 90% 90.3% 91.5% 89.5% 90% 89.5% 90.5% 91% 92.3% Package (Case, Pinout) C59, P32 Output capacitors are 1uF ceramic || 10 uF electrolytic. Input cap is 22 uF, low ESR, except UVQ-24/4.5 is 33uF and UVQ-48/2.5 uses no input cap. I/O caps are necessary for our test equipment and may not be needed for your application. f IOUT = 14 Amps max. with VIN = 18-19.5 Volts. Models available with Pin 9: UVQ-12/10-D48 UVQ-1.5/40-D24 Models which are NOT available with Pin 9: UVQ-5/20-D24 and –D48 UVQ-3.3/30-D24 UVQ-3.3/35-D48 UVQ-2.5/35-D24 UVQ-2.5/40-D48 Other models which are not listed will be reviewed for future pin 9 accomodation. Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 2 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters PART NUMBER STRUCTURE U VQ - 3.3 / 20 - D48 N B 9 LX - C RoHS-6 hazardous substance compliant Output Configuration U = Unipolar/Single Alternate Pin Length: (special quantity order) Blank = Standard pin length L1 = 0.110 (2.79mm) L2 = 0.145 (3.68mm) Quarter-Brick Package Nominal Output Voltage Baseplate Pin 9, see Mechanical Drawings: (special order) 1.2 to 48 Volts Blank = No pin 9, standard 9 = Pin 9 installed (see description on pg. 2), optional Maximum Rated Output Current in Amps Blank = No baseplate, standard B = Baseplate installed, optional special order Input Voltage Range: D24 = 18-36 Volts (24V nominal) D48 = 36-75 Volts (48V nominal) * Note: Remote On/Off Control Polarity: Some model number combinations may not be Add "P" for positive polarity available. Contact Murata Power Solutions.. Add "N" for negative polarity Positive "P" polarity is standard for D24 models and optional special order for D48 models. Negative "N" polarity is standard for D48 models and optional special order for D24 models. +SENSE (7) +VOUT (8) +VIN (3) Baseplate (9) Optional SWITCH CONTROL –VOUT (4) –VIN (1) –SENSE (5) PWM CONTROLLER OPTO ISOLATION INPUT UNDERVOLTAGE, INPUT OVERVOLTAGE, AND OUTPUT OVERVOLTAGE COMPARATORS REMOTE ON/OFF CONTROL* (2) REFERENCE & ERROR AMP VOUT TRIM (6) * Can be ordered with positive (standard) or negative (optional) polarity. Typical configuration — some models use a different topology Figure 1. Simplified Schematic www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 3 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters Performance/Functional Specifications 24V Models UVQ-48/2.5-D24 17 UVQ-24/4.5-D24 UVQ-5/20-D24 17 UVQ-18/5.6-D24 UVQ-3.3/30-D24 17 UVQ-15/7-D24 UVQ-2.5/35-D24 17 17 17 17 17 17 16.25 16 16.25 16 16 UVQ-12/8-D24 UVQ-1.5/40-D24 Typical @ TA = +25°C under nominal line voltage, nominal output voltage, natural air convection, external caps and full-load conditions, unless noted. (1) Input Input voltage range Start-up threshold, (V) min. See ordering guide Undervoltage shutdown, (V)14 16 Overvoltage shutdown (V) none 39 Reflected (back) ripple current2 none 10-50 mA pk-pk, model dependent Input Current Full load conditions Inrush transient, (A2sec) See ordering guide. 0.5 0.5 0.05 0.5 1 1 0.05 0.05 Output short circuit, (mA) 40 10 320 50 50 50 No load, mA 80 100 180 160 90 103 140 45 30 3.79 5.49 6.04 5.57 5.93 6.52 6.29 6.67 3.60 Low line (VIN = min.), (Amps) 50 0.1 Standby mode, (Off, UV, OT shutdown) Internal input filter type 1-4mA, model dependent L-C Pi-type Reverse polarity protection L-C See notes. Remote On/Off Control5 Positive logic, "P" suffix (specifications are max) OFF = Ground pin to +0.8V ON = Open or +5V to +VIN max. Negative logic, "N" suffix (specifications are max) OFF = Open or +5V to +VIN max ON = Ground pin to+0.8V max Current 1-8 mA, model dependent www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 4 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters Performance/Functional Specifications 24V Models UVQ-48/2.5-D24 UVQ-24/4.5-D24 UVQ-18/5.6-D24 UVQ-15/7-D24 UVQ-12/8-D24 UVQ-5/20-D24 UVQ-3.3/30-D24 UVQ-2.5/35-D24 UVQ-1.5/40-D24 Typical @ TA = +25°C under nominal line voltage, nominal output voltage, natural air convection, external caps and full-load conditions, unless noted. (1) Output Voltage output range See ordering guide. Voltage output accuracy (50% load) ±1.5% of VNOM ±1.25% of VNOM Adjustment range –20 to +10% of VNOM. ±10% of VNOM. ±0.02% of VOUT range per °C Temperature coefficient Minimum loading No minimum load 3 amps No minimum load Remote sense compensation +10%. Ripple/noise See ordering guide. Line/Load regulation See ordering guide. Efficiency See ordering guide. Maximum capacitive loading, Low ESR <0.02Ω max., resistive load, (μF) Current limit inception (98% of VOUT, after warmup), (Amps) 10,000 45 5000 44 36 Short circuit protection method Short circuit current, (Amps) 4700 24 10 9.5 2200 7 5.8 3.4 5 2.8 Current limiting, hiccup autorestart. Remove overload for recovery. 3.6 3 3 Short circuit duration Overvoltage protection, (via magnetic feedback) ±1% of VNOM 3 1.5 15 mA 3 Output may be shorted continuously to ground (no damage). 2.3 Volts 3 Volts max 4 Volts max 6.8 Volts max 14.4 Volts max 18.5 Volts 22 Volts max 29 Volts max 59 Volts max Isolation Characteristics Isolation Voltage Input to Output, (Volts min) 2000 Input to baseplate 1500 Baseplate to output, (Volts min) 1500 1000 Isolation resistance Isolation capacitance, (pF) 1500 100 MΩ 1500 Isolation safety rating 1000 2000 50 Basic insulation www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 5 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters Performance/Functional Specifications 24V Models UVQ-48/2.5-D24 UVQ-24/4.5-D24 UVQ-18/5.6-D24 UVQ-15/7-D24 UVQ-12/8-D24 UVQ-5/20-D24 UVQ-3.3/30-D24 UVQ-2.5/35-D24 UVQ-1.5/40-D24 Typical @ TA = +25°C under nominal line voltage, nominal output voltage, natural air convection, external caps and full-load conditions, unless noted. (1) Dynamic characteristics Dynamic load response (50-75-50% load step) Start-up time VIN to VOUT regulated, mSec Remote On/Off to VOUT regulated, mSec Switching frequency, (KHz) 100 μSec to ±1% of final value 90msec 150 μSec to 150 μSec to 100 μSec to 50 μSec 40 μSec to 50 μSec to 100 μSec 100 μSec ±1.5% ±1.5% ±1.5% of final to ±1% ±1.25% ±1% to ±1% to ±1% of final value of final value value of final value of final value of final value of final value of final value 50msec 50msec 200msec 40msec 30msec 90msec 50msec 50msec 380 ± 30 500 to 650 600 30msec 290msec 100msec 200msec 30msec 25msec 35msec 200msec 100msec 360 290 ± 30 242 240 ± 25 290 ± 30 250 ± 25 Environmental Calculated MTBF4 TBD Operating temperature range: see Derating Curves. −40 to +85°C (with Derating, see Note 15.) Operating temperature, with baseplate, no derating required (°C)3 −40 to +110 Storage temperature (°C) −40 to +115 −40 to +110 −55 to +130 −55 to +125 Thermal protection/ shutdown +110 to 125°C, model dependent Relative humidity To +85°C/85%, non-condensing Physical Outline dimensions See mechanical specs. Baseplate material Aluminum Pin material Brass alloy Pin diameter Weight Electromagnetic interference (conducted and radiated) (external filter required) Safety 0.04/0.062 inches (1.016/1.524 mm) 1.55 ounce (44 grams) 1 ounce (28 grams) Designed to meet FCC part 15, class B, EN55022 Designed to meet UL/cUL 60950-1, CSA C22.2 No.60950-1, IEC/EN 60950-1 www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 6 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters Performance/Functional Specifications 48V Models UVQ-48/2.5-D48 UVQ-24/4.5-D48 UVQ-18/6-D48 UVQ-15/7-D48 UVQ-12/10-D48 UVQ-5/20-D48 UVQ-3.3/35-D48 UVQ-2.5/40-D48 Typical @ TA = +25°C under nominal line voltage, nominal output voltage, natural air convection, external caps and full-load conditions, unless noted. (1) Input Input voltage range See ordering guide Start-up threshold, min (V) 35 Undervoltage shutdown, (V)14 34.5 34 33.5 34.5 35 32 Overvoltage shutdown (V) 33.5 none Reflected (back) ripple current 10-50 mA pk-pk, model dependent Input Current Full load conditions Inrush transient, (A2sec) See ordering guide. 0.05 0.05 No load, mA 100 Low line (VIN = min.), (Amps) 3.15 Output short circuit, (mA) 1 1 10 130 80 60 3.56 3.07 3.72 3.21 50 Standby mode, (Off, UV, OT shutdown) Internal input filter type 0.05 1 0.05 0.05 30 50 250 50 30 80 45 30 3.35 3.30 3.60 1-4mA, model dependent L-C Pi-type Reverse polarity protection L-C See notes. Remote On/Off Control5 Positive logic, "P" suffix (specifications are max) OFF = Ground pin to +0.8V ON = Open or +5V to +VIN max Negative logic, "N" suffix (specifications are max) OFF = Open or +5V to +VIN max ON = Ground pin to+0.8V max Current 1-8 mA, model dependent www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 7 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters Performance/Functional Specifications 48V Models UVQ-48/2.5-D48 UVQ-24/4.5-D48 UVQ-18/6-D48 UVQ-15/7-D48 UVQ-12/10-D48 UVQ-5/20-D48 UVQ-3.3/35-D48 UVQ-2.5/40-D48 Typical @ TA = +25°C under nominal line voltage, nominal output voltage, natural air convection, external caps and full-load conditions, unless noted. (1) Output Voltage output range See ordering guide. Voltage output accuracy (50% load) ±1.5% of VNOM ±1.25% of VNOM Adjustment range –20 to +10% of VNOM. ±0.02% of VOUT range per °C Temperature coefficient Minimum loading ±1% of VNOM No minimum load 3 Amps No minimum load No minimum load Remote sense compensation +10%. Ripple/noise See ordering guide. Line/Load regulation See ordering guide. Efficiency See ordering guide. Maximum capacitive loading, Low ESR <0.02Ω max., resistive load, (μF) Current limit inception (98% of VOUT, after warmup), (Amps) 10,000 46 4700 48 Short circuit protection method 26 8.5 7 1000 6.5 3.3 3 3.5 29 Volts max 55 Volts max Current limiting, hiccup autorestart. Remove overload for recovery. Short circuit current, (Amps) 5 0.1 Short circuit duration Overvoltage protection, (via magnetic feedback) 12.5 2200 1.5 3 3 Output may be shorted continuously to ground (no damage). 3 Volts max 4 Volts max 6 Volts max 14.4 Volts max 18.5 Volts max 22 Volts max Isolation Characteristics Isolation Voltage Input to Output, (Volts min) 2250 Input to baseplate 1500 Baseplate to output, (Volts min) 1500 1500 Isolation resistance Isolation capacitance, (pF) 100 MΩ 1500 Isolation safety rating 1000 50 50 1500 Basic insulation www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 8 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters Performance/Functional Specifications 48V Models 50msec 50msec 50msec 50msec 30msec 30msec 30msec 100msec 50msec 600 600 450 ± 50 290 ± 30 245 ± 20 240 ± 25 290 ± 30 540 ± 40 −40 to +110 −40 to +120 UVQ-15/7-D48 UVQ-48/2.5-D48 50msec UVQ-5/20-D48 UVQ-24/4.5-D48 150 μSec to ±1.5% of final value UVQ-18/6-D48 UVQ-3.3/35-D48 150 μSec to ±1.5% of final value UVQ-12/10-D48 UVQ-2.5/40-D48 Typical @ TA = +25°C under nominal line voltage, nominal output voltage, natural air convection, external caps and full-load conditions, unless noted. (1) Dynamic characteristics Dynamic load response (50-75-50% load step) Start-up time VIN to VOUT regulated, mSec Remote On/Off to VOUT regulated, mSec Switching frequency, (KHz) 90 μSec 100 μSec 50 μSec to ±1% 50 μSec to ±1% 50 μSec to ±1% to ±2% to ±1% of final value of final value of final value of final value of final value 50msec 40msec 30msec 30msec 100msec 75 μSec to ±1% of final value 50msec Environmental Calculated MTBF4 TBD Operating temperature range: see Derating Curves. Operating temperature, with baseplate, no derating required (°C)3 −40 to +85°C (with Derating, see Note 15.) −40 to +110 −40 to +115 Storage temperature (°C) −40 to +110 −55 to +125 Thermal protection/ shutdown +110 to 125°C, model dependent Relative humidity To +85°C/85%, non-condensing Physical Outline dimensions See mechanical specs. Baseplate material Aluminum Pin material Brass alloy Pin diameter 0.04/0.062 inches (1.016/1.524 mm) Weight Electromagnetic interference (conducted and radiated) (external filter required) Safety 1 ounce (28 grams) Designed to meet FCC part 15, class B, EN55022 Designed to meet UL/cUL 60950-1, CSA C22.2 No.60950-1, IEC/EN 60950-1 www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 9 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters PART NUMBER STRUCTURE Input Voltage Continuous Transient (100 mS) 24V models 0 to +36V +50V 48V models 0 to +75V +100V On/Off Control –0.3 V min to +13.5V max. Input Reverse Polarity Protection See Fuse section Output Overvoltage VOUT +20% max. Output Current (Note 7) Current-limited. Devices can withstand sustained short circuit without damage. Storage Temperature –55 to +125°C Lead Temperature See soldering guidelines Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied nor recommended. (1) All models are tested and specified with 200 LFM airflow, external 1||10μF ceramic/ tantalum output capacitors. External input capacitance varies according to model type. All capacitors are low ESR types. These capacitors are necessary to accommodate our test equipment and may not be required to achieve specified performance in your applications. All models are stable and regulate within spec under no-load conditions. General conditions for Specifications are +25°C, VIN =nominal, VOUT = nominal, full load. (2) Input Ripple Current is tested and specified over a 5-20MHz bandwidth. Input filtering is CIN = 33μF tantalum, CBUS = 220μF electrolytic, LBUS = 12μH. (3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if the total RMS current over time does not exceed the Derating curve. (4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fixed conditions, TPCBOARD = +25°C, full output load, natural air convection. (5) The On/Off Control may be driven with external logic or by applying appropriate external voltages which are referenced to Input Common. The On/Off Control Input should use either an open collector/open drain transistor or logic gate which does not exceed +13.5V. (6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting. (7) The outputs are not intended to sink appreciable reverse current. (8) Output noise may be further reduced by adding an external filter. See I/O Filtering and Noise Reduction. (9) All models are fully operational and meet published specifications, including “cold start” at –40°C. (10) Regulation specifications describe the deviation as the line input voltage or output load current is varied from a nominal midpoint value to either extreme. (11) Overvoltage shutdown on 48V input models is not supplied in order to comply with telecom reliability requirements. These requirements attempt continued operation despite significant input overvoltage. (12) Do not exceed maximum power specifications when adjusting the output trim. (13) Note that the converter may operate up to +110°C with the baseplate installed. However, thermal self-protection occurs near +110°C, and there is a temperature gradient between the hotspot and the baseplate. Therefore, +100°C is recommended to avoid thermal shutdown. (14) The converter is guaranteed to turn off at the UV shutdown voltage. (15) At full power, the package temperature of all on-board components must not exceed +128°C. www.murata-ps.com MECHANICAL SPECIFICATIONS Removal of Soldered UVQ's from Printed Circuit Boards Should removal of the UVQ from its soldered connection be needed, thoroughly de-solder the pins using solder wicks or de-soldering tools. At no time should any prying or leverage be used to remove boards that have not been properly de-soldered first. Input Source Impedance UVQ converters must be driven from a low ac-impedance input source. The DC/DC’s performance and stability can be compromised by the use of highly inductive source impedances. The input circuit shown in Figure 2 is a practical solution that can be used to minimize the effects of inductance in the input traces. For optimum performance, components should be mounted close to the DC/DC converter. I/O Filtering, Input Ripple Current, and Output Noise All models in the UVQ Series are tested/specified for input ripple current (also called input reflected ripple current) and output noise using the circuits and layout shown in Figures 2 and 3. TO OSCILLOSCOPE 3 +INPUT LBUS + VIN CURRENT PROBE CBUS CIN – 1 –INPUT CIN = 33μF, ESR < 700mΩ @ 100kHz CBUS = 220μF, ESR < 100mΩ @ 100kHz LBUS = 12μH Figure 2. Measuring Input Ripple Current External input capacitors (CIN in Figure 2) serve primarily as energy-storage elements. They should be selected for bulk capacitance (at appropriate frequencies), low ESR, and high rms-ripple-current ratings. The switching nature of DC/DC converters requires that dc voltage sources have low ac impedance as highly inductive source impedance can affect system stability. In Figure 2, CBUS and LBUS simulate a typical dc voltage bus. Your specific system configuration may necessitate additional considerations. Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 10 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters In critical applications, output ripple/noise (also referred to as periodic and random deviations or PARD) can be reduced below specified limits using filtering techniques, the simplest of which is the installation of additional external output capacitors. Output capacitors function as true filter elements and should be selected for bulk capacitance, low ESR, and appropriate frequency response. In Figure 3, the two copper strips simulate real-world pcb impedances between the power supply and its load. Scope measurements should be made using BNC connectors or the probe ground should be less than ½ inch and soldered directly to the fixture. All external capacitors should have appropriate voltage ratings and be located as close to the converter as possible. Temperature variations for all relevant parameters should be taken into consideration. OS-CONTM organic semiconductor capacitors (www.sanyo.com) can be especially effective for further reduction of ripple/noise. The most effective combination of external I/O capacitors will be a function of line voltage and source impedance, as well as particular load and layout conditions. On/Off Control The primary-side, Remote On/Off Control function (pin 2) can be specified to operate with either positive or negative polarity. Positive-polarity devices ("P" suffix) are enabled when pin 2 is left open or is pulled high. Positivepolarity devices are disabled when pin 2 is pulled low (0-0.8V with respect to –Input). Negative-polarity devices are off when pin 2 is high/open and on when pin 2 is pulled low. See Figure 4. Dynamic control of the remote on/off function is best accomplished with a mechanical relay or an open-collector/open-drain drive circuit (optically isolated if appropriate). The drive circuit should be able to sink appropriate current (see Performance Specifications) when activated and withstand appropriate voltage when deactivated. ).054 %15)6!,%.4#)2#5)4&/2 0/3)4)6%!.$.%'!4)6% ,/')#-/$%,3 6 /./&& #/.42/, +SENSE +OUTPUT 7 #/.42/, COPPER STRIP 8 2%& C1 C2 SCOPE n).054 #/--/. RLOAD Figure 4. Driving the Remote On/Off Control Pin 4 –OUTPUT 5 –SENSE COPPER STRIP C1 = 1μF CERAMIC C2 = 10μF TANTALUM LOAD 2-3 INCHES (51-76mm) FROM MODULE Figure 3. Measuring Output Ripple/Noise (PARD) Start-Up Threshold and Undervoltage Shutdown Under normal start-up conditions, the UVQ Series will not begin to regulate properly until the ramping input voltage exceeds the Start-Up Threshold. Once operating, devices will turn off when the applied voltage drops below the Undervoltage Shutdown point. Devices will remain off as long as the undervoltage condition continues. Units will automatically re-start when the applied voltage is brought back above the Start-Up Threshold. The hysteresis built into this function avoids an indeterminate on/off condition at a single input voltage. See Performance/Functional Specifications table for actual limits. Start-Up Time The VIN to VOUT Start-Up Time is the interval between the point at which a ramping input voltage crosses the Start-Up Threshold voltage and the point at which the fully loaded output voltage enters and remains within its specified r1% accuracy band. Actual measured times will vary with input source impedance, external input capacitance, and the slew rate and final value of the input voltage as it appears to the converter. The On/Off to VOUT start-up time assumes that the converter is turned off via the Remote On/Off Control with the nominal input voltage already applied. www.murata-ps.com Current Limiting When power demands from the output falls within the current limit inception range for the rated output current, the DC/DC converter will go into a current limiting mode. In this condition the output voltage will decrease proportionately with increases in output current, thereby maintaining a somewhat constant power dissipation. This is commonly referred to as power limiting. Current limit inception is defined as the point where the full-power output voltage falls below the specified tolerance. If the load current being drawn from the converter is significant enough, the unit will go into a short circuit condition. See “Short Circuit Condition.” Short Circuit Condition When a converter is in current limit mode the output voltages will drop as the output current demand increases. If the output voltage drops too low, the magnetically coupled voltage used to develop primary side voltages will also drop, thereby shutting down the PWM controller. Following a time-out period of about 50 milliseconds, the PWM will restart, causing the output voltages to begin ramping to their appropriate values. If the short-circuit condition persists, another shutdown cycle will be initiated. This on/off cycling is referred to as “hiccup” mode. The hiccup cycling reduces the average output current, thereby preventing internal temperatures from rising to excessive levels. The UVQ is capable of enduring an indefinite short circuit output condition. Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 11 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters Thermal Shutdown UVQ converters are equipped with thermal-shutdown circuitry. If the internal temperature of the DC/DC converter rises above the designed operating temperature (See Performance Specifications), a precision temperature sensor will power down the unit. When the internal temperature decreases below the threshold of the temperature sensor, the unit will self start. Output Overvoltage Protection The output voltage is monitored for an overvoltage condition via magnetic coupling to the primary side. If the output voltage rises to a fault condition, which could be damaging to the load circuitry (see Performance Specifications), the sensing circuitry will power down the PWM controller causing the output voltage to decrease. Following a time-out period the PWM will restart, causing the output voltage to ramp to its appropriate value. If the fault condition persists, and the output voltages again climb to excessive levels, the overvoltage circuitry will initiate another shutdown cycle. This on/off cycling is referred to as "hiccup" mode. Input Reverse-Polarity Protection If the input-voltage polarity is accidentally reversed, an internal diode will become forward biased and likely draw excessive current from the power source. If the source is not current limited or the circuit appropriately fused, it could cause permanent damage to the converter. Input Fusing Certain applications and/or safety agencies may require the installation of fuses at the inputs of power conversion components. Fuses should also be used if the possibility of a sustained, non-current-limited, input-voltage polarity reversal exists. For MPS UVQ Series DC/DC Converters, slow-blow fuses are recommended with values no greater than twice the maximum input current. Trimming Output Voltage UVQ converters have a trim capability (pin 6) that enables users to adjust the output voltage from +10% to –20% (refer to the trim equations). Adjustments to the output voltage can be accomplished with a single fixed resistor as shown in Figures 5 and 6. A single fixed resistor can increase or decrease the output voltage depending on its connection. Resistors should be located close to the converter and have TCR's less than 100ppm/°C to minimize sensitivity to changes in temperature. If the trim function is not used, leave the trim pin open. 1 –INPUT +OUTPUT +SENSE 2 ON/OFF CONTROL TRIM 3 +INPUT –OUTPUT –INPUT +OUTPUT +SENSE 2 ON/OFF CONTROL TRIM +INPUT 7 6 LOAD RTRIM DOWN –SENSE 3 8 –OUTPUT 5 4 Figure 6. Trim Connections To Decrease Output Voltages Using Fixed Resistors Standard UVQ's have a "positive trim" where a single resistor connected from the Trim pin (pin 6) to the +Sense (pin 7) will increase the output voltage. A resistor connected from the Trim Pin (pin 6) to the –Sense (pin 5) will decrease the output voltage. Trim adjustments greater than the specified +10%/–20% can have an adverse affect on the converter’s performance and are not recommended. Excessive voltage differences between VOUT and Sense, in conjunction with trim adjustment of the output voltage, can cause the overvoltage protection circuitry to activate (see Performance Specifications for overvoltage limits). Temperature/power derating is based on maximum output current and voltage at the converter's output pins. Use of the trim and sense functions can cause output voltages to increase, thereby increasing output power beyond the UVQ's specified rating, or cause output voltages to climb into the output overvoltage region. Therefore: (VOUT at pins) x (IOUT) d rated output power The Trim pin (pin 6) is a relatively high impedance node that can be susceptible to noise pickup when connected to long conductors in noisy environments. Soldering Guidelines Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceeding these specifications may cause damage to the product. Be cautious when there is high atmospheric humidity. We strongly recommend a mild pre-bake (100° C. for 30 minutes). Your production environment may differ; therefore please thoroughly review these guidelines with your process engineers. 8 7 6 LOAD RTRIM UP –SENSE 1 Wave Solder Operations for through-hole mounted products (THMT) For Sn/Ag/Cu based solders: 5 Maximum Preheat Temperature 4 115° C. Maximum Pot Temperature 270° C. Maximum Solder Dwell Time 7 seconds For Sn/Pb based solders: Figure 5. Trim Connections To Increase Output Voltages Using Fixed Resistors www.murata-ps.com Maximum Preheat Temperature 105° C. Maximum Pot Temperature 250° C. Maximum Solder Dwell Time 6 seconds Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 12 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters Trim Equations F E AT U R E S A N D O P T I O N S Trim Up Trim Down Remote Sense UVQ-1.5/40-D24 RT UP (k:) = 6.23(VO – 1.226) –10.2 VO – 1.5 RTDOWN (k:) = 7.64 1.5 – VO –10.2 UVQ-2.5/40-D48, UVQ-2.5/35-D24 RT UP (k:) = 10(VO – 1.226) –10.2 VO – 2.5 RTDOWN (k:) = 12.26 2.5 – VO –10.2 UVQ-3.3/35-D48 RT UP (k:) = 13.3(VO – 1.226) VO – 3.3 –10.2 RTDOWN (k:) = 16.31 3.3 – VO –10.2 UVQ-5/25-D24, UVQ-5/20-D48 RT UP (k:) = 20.4(VO – 1.226) VO – 5 –10.2 RTDOWN (k:) = 25.01 5 – VO –10.2 Note: The Sense and VOUT lines are internally connected through lowvalue resistors. Nevertheless, if the sense function is not used for remote regulation the user must connect the +Sense to +VOUT and -Sense to –VOUT at the DC/DC converter pins. UVQ series converters employ a sense feature to provide point of use regulation, thereby overcoming moderate IR drops in pcb conductors or cabling. The remote sense lines carry very little current and therefore require minimal cross-sectional-area conductors. The sense lines, which are capacitively coupled to their respective output lines, are used by the feedback control-loop to regulate the output. As such, they are not low impedance points and must be treated with care in layouts and cabling. Sense lines on a pcb should be run adjacent to dc signals, preferably ground. In cables and discrete wiring applications, twisted pair or other techniques should be implemented. UVQ series converters will compensate for drops between the output voltage at the DC/DC and the sense voltage at the DC/DC provided that: UVQ-12/8-D24, -12/10-D48 RT UP (k:) = 49.6(VO – 1.226) VO – 12 –10.2 RTDOWN (k:) = [VOUT(+) –VOUT(–)] – [Sense(+) –Sense (–)] ≤ 10% VOUT 60.45 12 – VO Contact and PCB resistance losses due to IR drops –10.2 1 –INPUT UVQ-15/7-D24, -D48 RT UP (k:) = 62.9(VO – 1.226) VO – 15 –10.2 RTDOWN (k:) = +OUTPUT +SENSE 76.56 15 – VO –10.2 8 7 IOUT Sense Current 2 ON/OFF CONTROL TRIM 6 LOAD Sense Return UVQ-18/5.6-D24, -18/6-D48 –SENSE 5 IOUT Return RT UP (k:) = 75.5(VO – 1.226) VO – 18 –10.2 RTDOWN (k:) = 92.9 18 – VO 3 –10.2 101(VO – 1.226) VO – 24 –10.2 RTDOWN (k:) = 210.75(VO – 1.226) VO – 48 –10.2 RTDOWN (k:) = 4 Figure 8. Remote Sense Circuit Configuration 124.2 24 – VO –10.2 UVQ-48/2.5-D24, -D48 RT UP (k:) = –OUTPUT Contact and PCB resistance losses due to IR drops UVQ-24/4.5-D24, -D48 RT UP (k:) = +INPUT 250 48 – VO –10.2 Note: Higher output 24V and 48V converters require larger, low-tempco, precision trim resistors. An alternative is a low-TC multi-turn potentiometer (20kΩ typical) connected between +VOUT and –VOUT with the wiper to the Trim pin. www.murata-ps.com Output overvoltage protection is monitored at the output voltage pin, not the Sense pin. Therefore, excessive voltage differences between VOUT and Sense in conjunction with trim adjustment of the output voltage can cause the overvoltage protection circuitry to activate (see Performance Specifications for overvoltage limits). Power derating is based on maximum output current and voltage at the converter's output pins. Use of trim and sense functions can cause output voltages to increase, thereby increasing output power beyond the conveter's specified rating, or cause output voltages to climb into the output overvoltage region. Therefore, the designer must ensure: (VOUT at pins) × (IOUT) ≤ rated output power Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 13 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters UVQ-1.5/40-D24N: Maximum Current Temperature Derating (No baseplate, V IN = 24V, transverse air flow) UVQ-1.5/40-D24N: Maximum Current Temperature Derating (With baseplate, V IN = 24V, transverse air flow) 40 40 39 Output Current (Amps) Output Current (Amps) 39 Natural convection 38 100 lfm 37 200 lfm 200 lfm 36 400 lfm 35 34 Natural convection 38 37 100 lfm 36 400 lfm 35 34 33 33 20 25 30 35 40 45 50 55 60 65 70 75 80 85 20 25 30 35 40 Ambient Temperature ( oC) 50 55 60 65 70 75 80 85 UVQ-2.5/40-D48 Power Dissipation vs. Load Current @ 25°C UVQ-2.5/40-D48N Efficiency vs. Line Voltage and Load Current @ 25°C 16 92 14 Power Dissipation (Watts) 88 84 80 Efficiency (%) 45 Ambient Temperature (oC) 76 VIN = 36V 72 VIN = 48V 68 12 VIN = 48V 10 8 6 4 VIN = 75V 2 64 0 62 0 5 10 15 20 25 30 35 0 40 5 10 15 20 25 30 35 40 Load Current (Amps) Load Current (Amps) UVQ-3.3/30-D24N: Maximum Current Temperature Derating (With baseplate, V IN = 24V, transverse air flow at sea level) UVQ-3.3/30-D24N: Maximum Current Temperature Derating (No baseplate, V IN = 24V, transverse air flow at sea level) 30 30 29 29 27 Output Current (Amps) Output Current (Amps) 28 Natural convection 26 25 100 lfm 24 200 lfm 23 300 lfm 22 21 28 Natural convection 27 100 lfm 26 200 lfm 25 300 lfm 24 400 lfm 400 lfm 20 23 19 22 18 17 21 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature ( oC) www.murata-ps.com 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (oC) Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 14 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters UVQ-3.3/35-D48 Maximum Current Temperature Derating (With baseplate, V IN = 48V, transverse air flow at sea level) 36 Output Current (Amps) 34 32 30 28 Natural Convection 26 100 lfm 24 200 lfm 22 300 lfm 20 400 lfm 18 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature ( oC) UVQ-5/20-D24P: Maximum Current Temperature Derating (No baseplate, VIN = 24V, transverse air flow) UVQ-5/20-D24PB: Maximum Current Temperature Derating (With baseplate, VIN = 24V, transverse air flow) 20 20 19.5 19.5 Output Current (Amps) Output Current (Amps) 19 18.5 18 17.5 17 Natural convection 100 lfm 200 lfm 300 lfm 400 lfm 16.5 16 15.5 19 18.5 Natural convection 100 lfm 200 lfm 300 lfm 400 lfm 18 17.5 17 16.5 15 16 14.5 14 15.5 20 25 30 35 40 45 50 55 60 65 70 75 80 20 85 25 30 35 40 Ambient Temperature (oC) 50 55 60 65 70 75 80 85 Ambient Temperature (oC) UVQ-5/20-D24P Efficiency vs. Line Voltage and Load Current @ +25°C UVQ-5/20-D24 Power Dissipation vs. Load Current @ +25°C 94 10 93 9 Power Dissipation (Watts) 92 91 Efficiency (%) 45 VIN = 18V 90 VIN = 24V 89 88 VIN = 30V 87 VIN = 36V 8 7 6 5 4 VIN = 18V VIN = 24V 3 86 VIN = 30V 2 85 VIN = 36V 1 84 5 6.5 8 9.5 11 12.5 14 15.5 17 18.5 20 Load Current (Amps) www.murata-ps.com 5 6.5 8 9.5 11 12.5 14 15.5 17 18.5 20 Load Current (Amps) Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 15 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters UVQ-5/20-D48 Efficiency vs. Line Voltage and Load Current @ 25°C UVQ-5/20-D48P: Maximum Current Temperature Derating (No baseplate, V IN = 48V, transverse air flow at sea level) 92 21 88 20 Output Current (Amps) Efficiency (%) 84 80 76 VIN = 36V 72 VIN = 48V 19 18 100 lfm 17 200 lfm 16 300 lfm 15 400 lfm 14 68 Natural convection VIN = 75V 13 64 12 20 25 30 35 40 45 50 55 60 65 70 75 80 85 62 0 2 4 6 8 10 12 14 16 18 20 Ambient Temperature (oC) Load Current (Amps) UVQ-5/20-D48PB: Maximum Current Temperature Derating (With baseplate, V IN = 48V, transverse air flow at sea level) 21 Output Current (Amps) 20 19 18 100 lfm 17 200 lfm 16 300 lfm 15 400 lfm 14 13 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature ( oC) www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 16 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters UVQ-12/8-D24P Efficiency vs. Line Voltage and Load Current @ +25°C UVQ-12/8-D24P: Maximum Current Temperature Derating (No baseplate, VIN = 24V, transverse air flow) 95 7.8 90 7.6 7.4 Efficiency (%) Output Current (Amps) 8.0 100 lfm 200 lfm 300 lfm 7.2 VIN = 18V 85 VIN = 24V VIN = 30V 7.0 80 VIN = 36V 6.8 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Ambient Temperature (oC) 75 0.8 1.6 2.4 3.2 4 4.8 5.6 6.4 7.2 8 Load Current (Amps) UVQ-12/10-D48N: Maximum Current Temperature Derating (No baseplate, VIN = 48V, transverse air flow) UVQ-12/10-D48N: Maximum Current Temperature Derating (With baseplate, VIN = 48V, transverse air flow) 10 10.0 Output Current (Amps) Output Current (Amps) 9.5 9 8 7 Natural convection 100 lfm 200 lfm 300 lfm 400 lfm 6 9.0 8.5 8.0 7.5 Natural convection 100 lfm 200 lfm 300 lfm 400 lfm 7.0 6.5 6.0 5 20 25 30 35 40 45 50 55 60 65 70 75 80 20 85 25 30 35 40 Ambient Temperature (oC) 45 50 55 60 65 70 75 80 85 Ambient Temperature (oC) UVQ-12/10-D48N Efficiency vs. Line Voltage and Load Current @ +25°C UVQ-12/10-D48N Power Dissipation vs. Load Current @ +25°C 15 92 13 88 VIN = 36V 86 VIN = 48V Power Dissipation (Watts) Efficiency (%) 90 VIN = 60V 84 VIN = 75V 82 11 VIN = 75V 9 VIN = 60V VIN = 48V 7 VIN = 36V 5 3 80 1 78 1 2 3 4 5 6 7 8 9 10 Load Current (Amps) www.murata-ps.com 1 2 3 4 5 6 7 8 9 10 Load Current (Amps) Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 17 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters UVQ-15/7-D24N: Maximum Current Temperature Derating (With baseplate, VIN = 24V, transverse air flow) 7.5 7.5 7 7 Output Current (Amps) Output Current (Amps) UVQ-15/7-D24N: Maximum Current Temperature Derating (No baseplate, VIN = 24V, transverse air flow) 6.5 6 5.5 Natural convection 100 lfm 200 lfm 300 lfm 400 lfm 5 4.5 6.5 6 Natural convection 100 lfm 200 lfm 300 lfm 400 lfm 5.5 5 4.5 4 4 20 25 30 35 40 45 50 55 60 65 70 75 80 85 20 90 25 30 35 40 45 Ambient Temperature (oC) UVQ-15/7-D24N Efficiency vs. Line Voltage and Load Current @ +25°C 92 11 Power Dissipation (Watts) 13 Efficiency (%) 90 VIN = 18V VIN = 24V 86 VIN = 30V 84 55 60 65 70 75 80 85 90 UVQ-15/7-D24N Power Dissipation vs. Load Current @ +25°C 94 88 50 Ambient Temperature (oC) VIN = 36V 9 VIN = 36V VIN = 30V 7 VIN = 24V VIN = 18V 5 3 82 1 80 0.7 1.4 2.1 2.8 3.5 4.2 4.9 5.6 6.3 7 Load Current (Amps) www.murata-ps.com 0.7 1.4 2.1 2.8 3.5 4.2 4.9 5.6 6.3 7 Load Current (Amps) Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 18 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters 7.0 6.8 6.6 6.4 6.2 6.0 5.8 5.6 5.4 5.2 5.0 4.8 4.6 4.4 4.2 4.0 UVQ-15/7-D48N: Maximum Current Temperature Derating (With baseplate, VIN = 48V, transverse air flow) Output Current (Amps) Output Current (Amps) UVQ-15/7-D48N: Maximum Current Temperature Derating (No baseplate, VIN = 48V, transverse air flow) Natural convection 100 lfm 200 lfm 300 lfm 400 lfm 20 25 30 35 40 45 50 55 60 65 70 75 80 85 7.0 6.8 6.6 6.4 6.2 6.0 5.8 5.6 5.4 5.2 5.0 4.8 4.6 4.4 4.2 4.0 Natural convection 100 lfm 200 lfm 300 lfm 20 90 25 30 35 40 45 Ambient Temperature (oC) UVQ-15/7-D48N Efficiency vs. Line Voltage and Load Current @ +25°C 11 92 10 60 65 70 75 80 85 90 9 Power Dissipation (Watts) 90 88 Efficiency (%) 55 UVQ-15/7-D48N Power Dissipation vs. Load Current @ +25°C 94 86 VIN = 36V 84 VIN = 48V 82 VIN = 60V 80 8 VIN = 75V VIN = 60V 7 VIN = 48V 6 VIN = 36V 5 4 3 VIN = 75V 2 78 76 0.7 50 Ambient Temperature (oC) 1 1.4 2.1 2.8 3.5 4.2 4.9 5.6 6.3 7 Load Current (Amps) www.murata-ps.com 0.7 1.4 2.1 2.8 3.5 4.2 4.9 5.6 6.3 7 Load Current (Amps) Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 19 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters UVQ-18/5.6-D24 Efficiency vs. Line Voltage and Load Current @ 25°C 92 90 Efficiency (%) 88 86 84 VIN = 18V 82 VIN = 24V 80 VIN = 36V 78 76 0.56 1.12 1.68 2.24 2.8 3.36 3.92 4.48 5.04 5.6 Load Current (Amps) UVQ-18/5.6-D24: Maximum Current Temperature Derating (No baseplate, V IN = 24V, transverse air flow) UVQ-18/5.6-D24: Maximum Current Temperature Derating (With baseplate, V IN = 24V, transverse air flow) 5.8 5.8 5.6 5.6 200 lfm 5.2 Output Current (Amps) Output Current (Amps) 5.4 300 lfm 5 4.8 400 lfm 100 lfm 4.6 4.4 4.2 4 Natural Convection 3.8 5.4 5.2 5 Natural Convection 4.8 100 lfm 200 lfm 4.6 300 lfm 400 lfm 4.4 4.2 3.6 4 3.4 20 25 30 35 40 45 50 55 60 65 70 75 80 20 85 25 30 35 Ambient Temperature ( oC) 45 50 55 60 65 70 75 80 85 Ambient Temperature (oC) UVQ-18/6-D48 Power Dissipation vs. Load Current @ 25°C UVQ-18/6-D48N Efficiency vs. Line Voltage and Load Current @ 25°C 16 95 14 90 Power Dissipation (Watts) VIN = 75V 85 Efficiency (%) 40 80 VIN = 36V 75 VIN = 48V 70 12 VIN = 48V 10 VIN = 36V 8 6 4 VIN = 75V 65 2 60 0.6 1.2 1.8 2.4 3 3.6 4.2 4.8 5.4 6 Load Current (Amps) 0 0.6 1.2 1.8 2.4 3 3.6 4.2 4.8 5.4 6 Load Current (Amps) www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 20 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters UVQ-18/6-D48: Maximum Current Temperature Derating (No baseplate, V IN = 48V, transverse air flow) 6.5 6.5 6 6 Output Current (Amps) Output Current (Amps) UVQ-18/6-D48: Maximum Current Temperature Derating (With baseplate, V IN = 48V, transverse air flow) 5.5 100 lfm 5 200 lfm 4.5 300 lfm 5.5 5 100 lfm 200 lfm 4.5 300 lfm 500 lfm 4 4 3.5 500 lfm 3.5 20 25 30 35 40 45 50 55 60 65 70 75 80 85 20 25 30 35 40 Ambient Temperature ( oC) 45 50 55 60 65 70 75 80 85 85 90 Ambient Temperature ( oC) UVQ-24/4.5-D24N Efficiency vs. Line Voltage and Load Current @ +25°C 91 90 89 Efficiency (%) 88 87 86 VIN = 18V 85 VIN = 24V 84 VIN = 30V 83 VIN = 36V 82 81 80 1.00 1.35 1.70 2.05 2.40 2.75 3.10 3.45 3.80 4.15 4.50 Load Current (Amps) UVQ-24/4.5-D48N Efficiency vs. Line Voltage and Load Current @ +25°C UVQ-24/4.5-D48N: Maximum Current Temperature Derating (No baseplate, VIN = 48V, transverse air flow) 92 4.5 90 86 Output Current (Amps) 88 VIN = 36V Efficiency (%) 84 VIN = 48V 82 80 VIN = 60V 78 76 VIN = 75V 4.3 400 lfm 300 lfm 200 lfm 100 lfm 4.0 3.8 3.5 74 3.3 72 70 3.0 68 20 66 64 1.00 25 30 35 40 45 50 55 60 65 70 75 80 Ambient Temperature (oC) 1.35 1.70 2.05 2.40 2.75 3.10 3.45 3.80 4.15 4.50 Load Current (Amps) www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 21 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters UVQ-48/2.5-D48N Efficiency vs. Line Voltage and Load Current @ 25°C UVQ-48/2.5-D48N: Maximum Current Temperature Derating (With baseplate, V IN = 48V, transverse air flow) 2.6 92 2.5 Output Current (Amps) 93 Efficiency (%) 91 90 VIN = 36V 89 VIN = 48V 2.4 Natural convection 2.3 100 lfm 2.2 200 lfm 88 VIN = 60V 2.1 87 VIN = 75V 2.0 86 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (oC) 85 0.25 0.5 0.75 1 1.25 1.5 1.75 2 2.25 2.5 Load Current (Amps) www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 22 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters UVQ Series Aluminum Heatsink The UVQ series converter baseplate can be attached either to an enclosure wall or a heatsink to remove heat from internal power dissipation. The discussion below concerns only the heatsink alternative. The UVQ’s are available with a low-profile extruded aluminum heatsink kit, models HS-QB25-UVQ, HS-QB50UVQ, and HS-QB100-UVQ. This kit includes the heatsink, thermal mounting pad, screws and mounting hardware. See the assembly diagram below. Do not overtighten the screws in the tapped holes in the converter. This kit adds excellent thermal performance without sacrificing too much component height. See the Mechanical Outline Drawings for assembled dimensions. If the thermal pad is firmly attached, no thermal compound (“thermal grease”) is required. Thermal Performance The HS-QB25-UVQ heatsink has a thermal resistance of 12 °C/Watt of internal heat dissipation with “natural convection” airflow (no fans or other mechanical airflow) at sea level altitude. This thermal resistance assumes that the heatsink is firmly attached using the supplied thermal pad and that there is no nearby wall or enclosure surface to inhibit the airflow. The thermal pad adds a negligible series resistance of approximately 0.5°C/Watt so that the total assembled resistance is 12.5°C/Watt. Be aware that we need to handle only the internal heat dissipation, not the full power output of the converter. This internal heat dissipation is related to the efficiency as follows: Power Dissipation [Pd] = Power In – Power Out [1] Power Out / Power In = Efficiency [in %] / 100 [2] 0!.(%!$3#2%7 -8-0,#3 Power Dissipation [Pd] = Power In x (1 –Efficiency%/100) [3] Power Dissipation [Pd] = Power Out x (1 / (Efficiency%/100) - 1) [4] Efficiency of course varies with input voltage and the total output power. Please refer to the Performance Curves. ,/#+7!3(%2 - 0,#3 &,!47!3(%2 ./ 0,#3 Since many applications do include fans, here is an approximate equation to calculate the net thermal resistance: R4 [at airflow] = R4 [natural convection] / (1 + (Airflow in LFM) x [Airflow Constant]) [5] Where, R4 [at airflow] is the net thermal resistance (in °C/W) with the amount of airflow available and, (%!43).+ R4 [natural convection] is the still air total path thermal resistance or in this case 12.5°C/Watt and, “Airflow in LFM” is the net air movement flow rate immediately at the converter. (%!442!.3&%20!$ 0EELOFFWHITEPLASTIC BACKINGMATERIALBEFORE ATTACHINGTOHEATSINK Figure 7. Model UVQ Heatsink Assembly Diagram When assembling these kits onto the converter, include ALL kit hardware to assure adequate mechanical capture and proper clearances. Thread relief is 0.090" (2.3mm). www.murata-ps.com This equation simplifies an otherwise complex aerodynamic model but is a useful starting point. The “Airflow Constant” is dependent on the fan and enclosure geometry. For example, if 200 LFM of airflow reduces the effective natural convection thermal resistance by one half, the airflow constant would be 0.005. There is no practical way to publish a “one size fits all” airflow constant because of variations in airflow direction, heatsink orientation, adjacent walls, enclosure geometry, etc. Each application must be determined empirically and the equation is primarily a way to help understand the cooling arithmetic. This equation basically says that small amounts of forced airflow are quite effective removing the heat. But very high airflows give diminishing returns. Conversely, no forced airflow causes considerable heat buildup. At zero airflow, cooling occurs only because of natural convection over the heatsink. Natural convection is often well below 50 LFM, not much of a breeze. While these equations are useful as a conceptual aid, most users find it very difficult to measure actual airflow rates at the converter. Even if you know the velocity specifications of the fan, this does not usually relate directly to the enclosure geometry. Be sure to use a considerable safety margin doing thermal analysis. If in doubt, measure the actual heat sink temperature with a calibrated thermocouple, RTD or thermistor. Safe operation should keep the heat sink below 100°C. Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 23 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters Calculating Maximum Power Dissipation To determine the maximum amount of internal power dissipation, find the ambient temperature inside the enclosure and the airflow (in Linear Feet per Minute – LFM) at the converter. Determine the expected heat dissipation using the Efficiency curves and the converter Input Voltage. You should also compensate for lower atmospheric pressure if your application altitude is considerably above sea level. The general proceedure is to compute the expected temperature rise of the heatsink. If the heatsink exceeds +100°C. either increase the airflow and/or reduce the power output. Start with this equation: Internal Heat Dissipation [Pd in Watts] = (Ts – Ta)/R4 [at airflow] [6] where “Ta” is the enclosure ambient air temperature and, where “Ts” is the heatsink temperature and, where “R4 [at airflow]” is a specific heat transfer thermal resistance (in degrees Celsius per Watt) for a particular heat sink at a set airflow rate. We have already estimated R4 [at airflow] in the equations above. Note particularly that Ta is the air temperature inside the enclosure at the heatsink, not the outside air temperature. Most enclosures have higher internal temperatures, especially if the converter is “downwind” from other heat-producing circuits. Note also that this “Pd” term is only the internal heat dissipated inside the converter and not the total power output of the converter. We can rearrange this equation to give an estimated temperature rise of the heatsink as follows: Heat Sink Example Assume an efficiency of 92% and power output of 100 Watts. Using equation [4], Pd is about 8.7 Watts at an input voltage of 48 Volts. Using +30°C ambient temperature inside the enclosure, we wish to limit the heat sink temperature to +90°C maximum baseplate temperature to stay well away from thermal shutdown. The +90°C. figure also allows some margin in case the ambient climbs above +30°C or the input voltage varies, giving us less than 92% efficiency. The heat sink and airflow combination must have the following characteristics: 8.7 W = (90-30) / R4[airflow] or, R4[airflow] = 60/8.7 = 6.9°C/W Since the ambient thermal resistance of the heatsink and pad is 12.5°C/W, we need additional forced cooling to get us down to 6.9°C/W. Using a hypothetical airflow constant of 0.005, we can rearrange equation [5] as follows: (Required Airflow, LFM) x (Airflow Constant) = R4[Nat.Convection] / R4[at airflow] –1 or, (Required Airflow, LFM) x (Airflow Constant) = 12.5/6.9 –1 = 0.81 and, rearranging again, (Required Airflow, LFM) = 0.81/0.005 = 162 LFM 162 LFM is the minumum airflow to keep the heatsink below +90°C. Increase the airflow to several hundred LFM to reduce the heatsink temperature further and improve life and reliability. Ts = (Pd x R4 [at airflow]) + Ta [7] 2.28 (57.91) Heatsink Kit * Model Number Still Air (Natural convection) thermal resistance Heatsink height (see drawing) HS-QB25-UVQ 12°C/Watt 0.25" (6.35mm) HS-QB50-UVQ 10.6°C/Watt 0.50" (12.7mm) HS-QB100-UVQ 8°C/Watt 1.00" (25.4mm) 1.860 (47.24) * Kit includes heatsink, thermal pad and mounting hardware. 1.03 1.45 (26.16) (36.83) 0.140 DIA. (3.56) (4 PLACES) * MATERIAL: BLACK ANODIZED ALUMINUM 0.10 (2.54) * UVQ SERIES HEATSINKS ARE AVAILABLE IN 3 HEIGHTS: 0.25 (6.35), 0.50 (12.70) AND 1.00 (25.4) Dimensions in inches (mm) www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 24 of 25 UVQ Series Low Profile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters Case C59 with Baseplate 2.30 (58.4) 1.860 (47.2) A B A B Case C59 0.42 (10.7) PINS 1-3, 5-7: 0.040 ±0.001 (1.016 ±0.025) PINS 4 & 8: 0.060 ±0.001 (1.52 ±0.025) 2.00 (50.8) 1.45 (36.8) 1.030 (26.2) 0.188 (4.78) B B A 1 4 5 6 7 2 0.600 (15.24) 4 EQ. SP. @ 0.150 (3.81) 8 3 BASEPLATE #M3-THREAD X 0.15 DEEP TYPICAL (4) PLACES 1.45 (36.8) 0.50 (12.7) PINS 1-3, 5-7: 0.040 ±0.001 (1.016 ±0.025) PINS 4 & 8: 0.060 ±0.001 (1.52 ±0.025) BOTTOM VIEW 0.188 (4.8) Alternate pin lengths are available. Contact Murata Power Solutions. Dimensions are in inches (mm shown for ref. only). 2.30 (58.4) 2.00 (50.8) Optional baseplate pin is special order. Contact Murata Power Solutions.. A B Third Angle Projection A 0.15 (3.81) 1 9 Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ 2 Optional pin 9 connects to baseplate. Electrically isolated from converter. 4 5 6 7 0.600 (15.24) 4 EQ. SP. @ 0.150 (3.81) 8 Components are shown for reference only. 3 I/O CONNECTIONS Pin Function P32 1 –Input 2 On/Off Control 3 +Input 4 –Output 5 –Sense 6 Output Trim 7 +Sense 8 +Output BOTTOM VIEW Important: If sense inputs are not connected to a remote load, connect them to their respective VOUT pins at the converter. USA: Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: [email protected] ISO 9001 and 14001 REGISTERED 03/05/09 Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2008 Murata Power Solutions, Inc. www.murata-ps.com Mansfield (MA), Tel: (508) 339-3000, email: [email protected] Canada: Toronto, Tel: (866) 740-1232, email: [email protected] UK: Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected] France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected] Germany: München, Tel: +49 (0)89-544334-0, email: [email protected] Japan: Tokyo, Tel: 3-3779-1031, email: [email protected] Osaka, Tel: 6-6354-2025, email: [email protected] China: Shanghai, Tel: +86 215 027 3678, email: [email protected] Guangzhou, Tel: +86 208 221 8066, email: [email protected] Singapore: Parkway Centre, Tel: +65 6348 9096, email: [email protected] Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UVQ Models.B11 Page 25 of 25