MURATA RUW15

RUW15 Series
www.murata-ps.com
Isolated Ultra-Wide Input DC/DC Converters
SELECTION GUIDE
Nom.
Output
Voltage
V
SL
SL
SL
SL
12
12
24
24
Input Voltage
Order Code1
RUW15SL12C
RUW15SL12HC
RUW15SL24C
RUW15SL24HC
Output Current
Min.
Max.
A
A
0.125
0.125
0.0625
0.0625
Output Power
Max.
W
1.25
1.25
0.625
0.625
MTTF3
kHrs
1550
959
1094
1176
15
15
15
15
INPUT CHARACTERISTICS
FEATURES
„
UL 60950 recognized for reinforced
insulation pending
„
High transient voltage withstand capability
„
Ultra wide input voltage range of
16-160VDC
„
Externally settable hold up time with
additional capacitor
„
DC OK/Power Fail signal
„
Short circuit protection
„
Over Temperature protection
„
Over voltage protection
DESCRIPTION
Parameter
Conditions
Voltage range2
Input standby current
Continuous operation SL I/P types
Min.
Typ.
16
Max.
Units
160
10
V
mA
INPUT CURRENT (10% Load)
Order Code
RUW15SL12C
RUW15SL12HC
RUW15SL24C
RUW15SL24HC
16
0.135
0.146
0.160
0.146
24
0.088
0.093
0.102
0.098
48
0.044
0.048
0.053
0.049
60
0.035
0.038
0.043
0.039
Input Voltage
72
0.030
0.032
0.036
0.033
96
0.023
0.025
0.029
0.027
110
0.022
0.024
0.028
0.025
132
0.018
0.021
0.025
0.022
160
0.015
0.018
0.021
0.018
Units
V
mAp-p
INPUT REFLECTED RIPPLE
Order Code
RUW15SL12C
RUW15SL12HC
RUW15SL24C
RUW15SL24HC
16
332.8
292.4
406.4
446.4
24
309.2
236.8
387.6
291.2
Input Voltage
48
72
184.8
155.2
142.4
107
249.6
195.6
176.4
157.2
110
138.8
86.5
167.5
101.8
160
119.6
76.3
138.8
82.7
Units
V
mAp-p
OUTPUT CHARACTERISTICS
The RUW series is particularly suitable for use
in applications in railway, industry or telecommunication where variable input voltages or
high transient voltages are present. With an ultra
wide input voltage range of 16-160VDC, the
RUW series is capable of withstanding surges
from 24,36,48,72, 90 and 110V systems, largely
eliminating the requirement for input protection
circuitry.
Optional features include a Power Fail/DC OK
signal and circuitry to facilitate long hold-up times
with a small external capacitor across ±Vint pins.
Parameter
Conditions
Voltage set point error
Overall voltage envelope
Line regulation
Load regulation
Ripple & noise
Transient response
Start delay
Overvoltage protection
Short circuit protection
Min.
Typ.
Max.
Units
0.8
3.0
1.5
%VOUT
%VOUT
RUW15SL12C
RUW15SL12HC & RUW15SL24HC
RUW15SL24C
10-100% Load
12VOUT types
BW = 20MHz
(24VIN to 110VIN)
24VOUT types
Peak deviation (20-100% & 100-20% swing)
3.0
%VOUT
Settling time
1.5
ms
From remote on/off RUWSLXXC
From application of VIN RUWSLXXC
0.5
0.2
0.25
0.25
%
%
mVp-p
TBD
TBD
110%
ms
VOUT
Continuous
1. Part numbers ending HC include optional Power Fail /DC OK signal and circuitry to facilitate long hold up time.
2. Will operate down to 14V for 100ms as required by EN 50155 (24V system).
3. Using Telecordia Issue 1 method I case 1 operating temperature 25C
All specifications typical at TA=25°C and rated output current unless otherwise specified.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_RUW15.A01 Page 1 of 5
RUW15 Series
Isolated Ultra-Wide Input DC/DC Converters
EFFICIENCY
Order Code
RUW15SL12C
RUW15SL12HC
RUW15SL24C
RUW15SL24HC
24
48
Min.
75.6
75.6
76.7
70.4
Typ.
77.1
77.1
77.7
75
GENERAL CHARACTERISTICS
Parameter
Min.
76.2
72.4
77.5
72.6
Typ.
78.2
75.9
78.6
77.3
Input Voltage
72
Min.
Typ.
74.1
77.3
70.8
75.4
76.5
77.8
72.2
76.9
Conditions
Units
110
Min.
72.6
69.6
74.3
70.9
160
Typ.
76.3
74.5
76
75.2
Min.
Switching frequency
Typ.
Typ.
71.7
69.6
70.1
69.2
Max.
0
V
%
Units
100
OPEN
Module on
Module off
Remote on/off pin functionality
Min.
65.7
63.1
66.3
63.8
kHz
0.5
V
ABSOLUTE MAXIMUM RATINGS
Input voltage, SL input types
Remote On/Off
170V
20V ±5V
APPLICATION NOTES
Output Capacitors
The RUW series does not require output capacitors to meet datasheet specification. To meet datasheet specifications, total output capacitance should not exceed:
Output Voltage (V)
12
15
Max. Recommended Output Capacitance (μF)
470
220
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Isolation test voltage
Resistance
Flash tested for 1 second
VISO = 500VDC
12VOUT types
24VOUT types
4000
Capacitance
Typ.
Max.
Units
VAC
GΩ
2
60
76
pF
ENVIRONMENTAL CHARACTERISTICS
Parameter
Conditions
Min.
Ambient temperature
Storage
Thermal protection
Case temperature rise above ambient
See derating graph
-40
-50
Operates at case temperature
100% load, still air, see derating graph
Typ.
120
40
Max.
Units
85
125
°C
°C
°C
°C
SAFETY
UL 60950 for reinforced insulation pending.
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC for 10 seconds. The pin termination finish
on this product series is a Gold flash (0.05-0.10 micron) over Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems.
Tinned tabs are provided along the case edges to provide mechanical support through slots in the PCB. Hand soldering of these tabs may be
necessary to ensure satisfactory joint quality.
For further information, please visit www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_RUW15.A01 Page 2 of 5
RUW15 Series
Isolated Ultra-Wide Input DC/DC Converters
OPTIONAL FEATURES
Hold-up
Hold-up Time at Full Load (mS)
Hold-up time is dependent on the value of capacitance across -VINT and +VINT. The graph below shows the approximate hold-up time for a given capacitance.
The active hold-up feature typically requires 60 seconds to fully reset between supply interuptions. Capacitor voltage rating should be 100VDC minimum.
120
100
80
60
40
20
0
0
100 200 300 400 500 600 700 800 900
VINT Capacitor (μF)
Power Fail Warning Details
The optional Power Fail/DC OK signal gives an advance warning of loss of output after input failure (typically 2ms) and an indication that the output voltage is within specification.
www.murata-ps.com/support
KDC_RUW15.A01 Page 3 of 5
RUW15 Series
Isolated Ultra-Wide Input DC/DC Converters
THERMAL DERATING GRAPHS
RUW15SL12HC
-40
14
12
12
12
12
10
10
still air
88
100 lfm
66
200 lfm
44
400 lfm
22
00
-40-40
20 -20 02
0 04
06
20
08 40 01
10
10
still air
8
8
100 lfm
6
6
200 lfm
4
4
400 lfm
2
2
0
0
00
100
RUW15SL24C
Available Power
Available Power
-40
14
-40-40
20 -20 02
0 04
06
20
08 40 01
00
100
RUW15SL24HC
-40
14
-40
14
12
12
12
12
10
10
Available Power
Available Power
RUW15SL12C
still air
88
100 lfm
66
200 lfm
44
400 lfm
22
10
10
100 lfm
66
200 lfm
44
400 lfm
22
00
00
-40-40
20-20
02
0 04
06
20
08 40
01
00
100
still air
88
-40-40
20 -20 02
004
0620
08 40 01
00
100
EFFICIENCY GRAPHS
RUW15SL12HC
90
90
70
70
50
110V
24V
48V
72V
30
10
Efficiency (%)
Efficiency (%)
RUW15SL12C
50
24V
48V
72V
110V
30
10
0
0
0
10
20
30
40
50
60
70
80
90
0
100
10
20
30
40
RUW15SL24C
60
70
80
90
100
RUW15SL24HC
90
90
70
70
50
24V
48V
72V
110V
30
10
Efficiency (%)
Efficiency (%)
50
Load (%)
Load (%)
50
24V
48V
72V
110V
30
10
0
0
0
10
20
30
40
50
60
70
Load (%)
80
90
100
0
10
20
30
40
50
60
70
80
90
100
Load (%)
www.murata-ps.com/support
KDC_RUW15.A01 Page 4 of 5
RUW15 Series
Isolated Ultra-Wide Input DC/DC Converters
PACKAGE SPECIFICATONS
Mechanical Dimensions
PIN CONNECTIONS
50.80 (2.0)
50.80 (2.0)
Pin
Function
1
2
3
4
5
6
7
8
REMOTE ON/OFF†
-VINT*
*
+VINT
-VIN
+VIN
*
PF/DC OK
+VOUT
-VOUT
Weight: 105g Typ.
All pins on a 3.81 (0.15) pitch and within ± 0.25 (0.01)
of true position.
Unless otherwise stated all dimensions are in mm
(inches) ± 0.25 (0.01).
20.00 (0.787)
2.80
(0.110)
4.8±0.6
(0.19±0.02)
+0.1
1.0 -0.5
2.00 (0.079)
4.00 (1.57)
28.00 (1.10)
10.40
(0.41)
†
Remote ON/OFF is referenced to input.
RECOMMENDED FOOTPRINT DETAILS
* Optional pins
3.81 (0.15)
34.29 (1.35)
9.27 (0.36)
Ø TBD
8 HOLES
5
6*
0.00394 (0.1)
*
3.81 (0.15)
4
7.62 (0.3)
*3
*
11.43 (0.45)
7
7.62 (0.3)
8
11.43 (0.45)
15.88 (0.63)
1
*
*2
3.81 (0.15)
8.26 (0.33)
bottom view
*Optional pins
All dimensions in mm ±0.5 (inches ±0.02) unless otherwise specified.
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2012 Murata Power Solutions, Inc.
www.murata-ps.com/support
KDC_RUW15.A01 Page 5 of 5