VISHAY PT50

PT-50
Vishay Dale
Through Hole Transformers Trigger, SCR Isolation
FEATURES
• Designed for low-cost trigger source isolation in
SCR power control circuits
• Small physical size and low profile provide
packaging advantages
• Designed to transfer high amplitude or long duration
pulses without saturation
• Industrial and commercial applications include motor
speed controls, lighting controls and heater controls
• Interchangeable. Designed for circuit board mounting
using same mounting dimensions as 11Z and PT-20
models
ELECTRICAL SPECIFICATIONS
Primary Inductance Values: From 200 μH to 5000 μH
• Compliant to RoHS directive 2002/95/EC
Turns Ratio: 1:1, 2:1 and 5:1
Temperature Range: - 55 °C to + 105 °C
MATERIAL SPECIFICATIONS
Dielectric Test at 60 Hz: 1600 VRMS (Windings to core)
Bobbin: Glass-filled nylon
AC Line Voltage at 60 Hz: 240 VRMS maximum in test
circuits shown
Terminals: 0.025" [0.635] square tinned copper
Material Rating: + 105 °C class A
STANDARD ELECTRICAL SPECIFICATIONS
TURNS
RATIO
PRIMARY
IND. MIN.
(μH)
LEAKAGE
IND. MAX.
(μH)
INTERWINDING
CAPACITY MAX.
(pF)
PRIMARY
DCR MAX.
(Ω)
SECONDARY
DCR MAX.
(Ω)
UNIPOLAR ET
(V-μs)
PT-50-101
1:1 ± 10 %
200
3
3
1.5
1.5
570
PT-50-102
1:1 ± 10 %
500
6
6
4.5
4.5
912
PT-50-103
1:1 ± 10 %
1000
12
12
8.0
8.0
1283
PT-50-104
1:1 ± 10 %
2000
13
13
12.0
12.0
1853
PT-50-105
1:1 ± 10 %
5000
15
15
18.4
18.4
2850
PT-50-106
2:1 ± 10 %
500
6
6
4.0
2.0
912
PT-50-107
2:1 ± 10 %
1000
10
10
10.0
2.0
1288
PT-50-108
2:1 ± 10 %
2000
12
12
10.0
5.0
1881
PT-50-109
2:1 ± 10 %
5000
15
15
18.0
10.0
2565
PT-50-110
5:1 ± 10 %
5000
1500
1500
19.0
3.0
2850
MODEL
DIMENSIONAL CONFIGURATIONS in inches [millimeters]
0.780
[19.8]
Max.
0.654
[16.6]
Max.
2
4
0.655
[16.9]
Max.
0.250 [6.35]
Min.
3
1
0.600
[15.24]
Document Number: 34074
Revision: 16-Dec-09
Dot identifies
#1 Terminal
0.025 [0.635]
Sq. Terminals Typ.
Schematic
Terminal Numbers
For Ref. Only
1
3
PRI.
SEC.
2
4
0.500
[12.70]
For technical questions, contact: [email protected]
www.vishay.com
1
PT-50
Through Hole Transformers Trigger, SCR Isolation
Vishay Dale
CIRCUIT DIAGRAM
PART MARKING
Load
- Vishay Dale
Line
- Model
- Dash number
Transformer Coupled Breakdown Diode Triggering Circuit
ORDERING INFORMATION
PT-50
101
EB
e2
MODEL
DASH NUMBER
PACKAGE CODE
JEDEC LEAD (Pb)-FREE
STANDARD
GLOBAL PART NUMBER
P
T
0
MODEL
www.vishay.com
2
5
0
E
B
PACKAGE CODE
For technical questions, contact: [email protected]
1
0
1
DASH NUMBER
Document Number: 34074
Revision: 16-Dec-09
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1
Document Number: 91000