DMS-EB Multi-Purpose Application Board for DMS-30 & DMS-40 Series Meters FEATURES Accommodates 3½ and 4½ digit meters Gain (span) and offset (zero) adjustments for DMS-30 meters Input divider network for high voltages Operate meter and board from +5V supply or 9/12V battery Solder gaps for decimal placement Same size as DMS-30/40 Series meters 2.02" (51.31mm)L x 0.83" (21.08mm)W PRODUCT OVERVIEW The DMS-EB Application Board covers many common panel meter applications while providing simple signal and power I/O terminations (via a standard MOLEX connector) for DATEL's DMS-30 and DMS-40 Series, LED/LCD Display, Digital Panel Voltmeters. The unique plug-and-play design of the DMS-EB makes changing from application to application and meter to meter quick, easy and inexpensive. The highly versatile DMS-EB has provisions for such common applications as attenuation of high input voltages, gain (span) and offset (zero) adjustments, 9/12V battery operation, and direct decimal point placement. The DMS-EB is compatible with all four versions of the DMS-30 and DMS-40 Series (±200mV, ±2V, ±20V and ±200V) making it interchangeable from meter to meter and application to application. Solder gaps conveniently placed on the board are easily bridged or cut configuring the board to meet each application's specific requirements. This low-cost addition to DATEL's expanding line of miniature meters is evidence of our continuing commitment to offer the most versatile, easy-to-use, panel meter products. SIMPLIFIED SCHEMATIC NOTE: Components are user-supplied and not part of the standard product. Figure 1. DMS-EB Schematic Diagram for DMS-30 Meters For full details go to www.murata-ps.com/rohs www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MPM_DMS-EB.B01 Page 1 of 4 DMS-EB Multi-Purpose Application Board for DMS-30 & DMS-40 Series Meters Ordering Information DMS-EB-C Application board with mating connector and terminals DMS-BZL1-C DMS-30/40 bezel assembly DMS-BZL2-C DMS-30/40 bezel assembly with sealing gasket Functional Specifications (TA = +25°C) Input Supply Range Input Supply Range DMS-30/40PC-X-XS DMS-30/40PC-X-XL DMS-30/40LCD-X-5 DMS-30/40LCD-X-5B See applicable meter's data sheet U1 (LM7805CT) Installed: +7.5 to +12.6V +7.5 to +18.0V +7.5 to +32.0V +7.5 to +12.6V Operating and Storage Temperature See applicable meter's data sheet Humidity 0 to 95%, non-condensing Dimensions 2.02" (51.31mm)L x 0.83" (21.08mm)W J1 Connector & Wire Information Terminal Type Crimp Tool Wire Size Insulation Diameter Stripping Length DATEL P/N 4400-01032-0 DATEL P/N 39-2099000 22 to 26 AWG 0.062" (1.57mm) max. 0.100" to 0.125" (2.54 to 3.17mm) Introduction As shipped, the DMS-EB is configured for 5V-powered DMS-30 3½ digit meters operating in the single-ended mode (SG5 closed) using the meter's internal reference (SG13 closed). This configuration is the most common and works well for most simple voltage measurements. Many of the applications described below apply to both DMS-30 and DMS-40 meters. However, Application 5, installing the span (R4) and offset (R5) adjust potentiometers, can only be used with DMS-30 meters. Also note that some of the other applications require the installation of R4 and R5. See Technical Note 5 when using the DMS-EB with DMS-40 meters. Please read all of the following technical notes and perform any required modifications before soldering the DMS-EB onto the meter (aligning pin 1 to pin 1). After soldering, carefully connect +5Vdc to +V (J1, pin 5) and power return to –V (J1, pin 6). TECHNICAL NOTES 1. LCD Backlighting: For DMS-30LCD backlit models, close SG15. For DMS-40LCD backlit models close SG18. See the DMS-30LCD or the DMS-40LCD data sheets for limitations on backlighting 9V-powered meters. 2. 9V-Powered, LCD Display Models: DMS-30LCD-X-9 and DMS40LCD-X/X-9 meters cannot be used in single-ended input configurations, i.e., LO (J1, pin 2) cannot be connected to GND (J1, pin 6). When operating from a 7.5 to 14Vdc power source with a single-ended input, use a +5V-powered meter and install U1 (see Battery Operation section and Technical Note 4). www.murata-ps.com Close SG6 when measuring floating inputs with a 9V-powered meter (floating inputs are described in Technical Note 7). SG6 provides a bias reference for the input signal by tying LO to the meter's Analog Common terminal (pin 10). 3. Input Resistor Dividers: Use 1%, or better, metal film resistors for R1 and R2 in DMS-30 applications, and 0.5%, or better, in DMS-40 applications. Using tight-tolerance resistors in input divider networks allows most final calibration adjustments to be made with the meter's rear calibration pots through the access holes provided. Make sure the resistor power and voltage ratings are adequate for the given application. 4. Using U1 (LM7805CT): The power supply voltage range listed in the Battery Operation section is rated for a 150mA LED meter or a 35mA backlit LCD meter. A 10μF/35V tantalum capacitor (C2) should be installed with the polarized end next to the + symbol on the DMS-EB. This is especially important if the power supply is located far from U1. 5. DMS-40 Meters: When the DMS-EB is used with DMS-40PC or DMS40LCD meters, be sure to open SG13. The RN-DMS resistor accessory kit comprised of resistor R3 and potentiometers R4 (Gain/Span) and R5 (Offset/Zero), cannot be used with DMS-40 series meters. To change the input range on DMS-40LCD meters from the low range to the high range, close SG16. 6. Calibration Potentiometer Adjustment Holes: Two overlapping holes on the DMS-EB provide access to the ¾-turn calibration potentiometer on DMS-30 meters and the 3-turn potentiometer on DMS-40 meters. The adjustment range of both pots is very narrow. See the applicable product data sheet for more information on each meter’s calibration potentiometers. 7. Input Configurations: The DMS-EB is supplied with SG5 closed. SG5 connects J1, pin 2 (LO) to power return J1, pin 6 (GND) and configures the meter for single-ended operation, that is, the low side of the input is at system ground or zero Volts. SG5 must also be closed when measuring floating inputs. Floating inputs are signals which have no electrical connection, or reference to, the power supply which powers the meter. In applications in which input LO is connected to ground elsewhere in the system, and SG5 is closed, unwanted ground-loop induced display errors may develop. Ground loops, a condition in which display drive currents also flow through the input signal wiring, can cause unstable display readings. If this occurs, try opening SG5 to see if the display stabilizes. SG5 must be open when measuring differential inputs that are referenced to the same supply which powers the meter. DMS Application Note 2 (Input Configurations, Power Supplies and Ground Loops) provides a detailed discussion of input configurations. 8. Soldering: DATEL recommends the use of "no-clean" solders when installing or making modifications to the DMS-EB. Technical enquiries email: [email protected], tel: +1 508 339 3000 MPM_DMS-EB.B01 Page 2 of 4 DMS-EB Multi-Purpose Application Board for DMS-30 & DMS-40 Series Meters APPLICATIONS 1. Decimal Point Placement: DATEL ships the DMS-EB with all decimal point solder gaps (SG1, SG2, SG3 and SG17) open. To enable a specific decimal point, close its respective solder gap with solder. When reassigning decimal places for subsequent applications, remember to open previously closed solder gaps. 5.1. For DMS-30-1 and -2 models: Configuring the DMS-EB for span adjustment is simply a matter of installing resistor R3 and potentiometer R4, opening SG13 and then closing SG8, SG11 and SG12. 5.2. For DMS-30-0 models: Span adjustment requires that you open SG8, SG11 (if closed) and SG13 and then close SG7, SG9 and SG12. Then install R3 and R4. Close SG1 for 1.999 (DP1) Close SG2 for 19.99 (DP2) Close SG3 for 199.9 (DP3) Close SG17 for 1999.9 (DP4 on DMS-40) 2. Display Test: Tie J1, pin 4 (TEST OUT) to pin 3 (TEST IN) to test the display of the DMS-30. Do not leave the meter in the test mode for more than 10 seconds. Display test is not available on backlit models. 3. Battery Operation: Open SG4 and install U1 (LM7805CT) with its metal tab facing down as shown Figure 2. Allowable input power ranges (J1, pins 5 and 6) are as follows: DMS-30/40PC-X-XS DMS-30/40PC-X-XL DMS-30/40LCD-X-5 DMS-30/40LCD-X-5B Using Full Range Span Adjustment (DMS-30 Only) +7.5 to +12.6V +7.5 to +18.0V +7.5 to +32.0V +7.5 to +12.6V Adjust span as desired. DMS-30-1 and -2 span adjustment range is typically +10% and –5%. The DMS-30-0 has a much wider span adjust, however, it should be limited to ±10% for optimum accuracy. 6. Measuring Input Voltages Greater than 1.999Vdc (Use DMS-30-1 Only): If possible, the resistors used for R1 and R2 should be ±1% metal-film types with TCR's less than 100ppm/°C. More information on selecting 1% resistors can be found in Application Note 14. CAUTION: Do not exceed 250Vdc input signals. 6.1. Open SG10. For applications in which input voltages exceed ±100Vdc, also cut the 2 adjoining traces. 6.2. Configure the DMS-EB for span adjust using the procedure reviously outlined for the DMS-30-1 version. 6.3. Calculate values for R1 and R2 as follows: U1 Metal tab points down R1 SG10 SG3 SG2 SG1 xxx.x xx.xx x.xxx To measure input voltages greater than ±100Vdc, open SG10 and also cut these two etch paths. Figure 2. Installing U1 4. Differential Input Signals (Signal Referenced to Power Source): Open SG5. Apply the input signal to pin 1, (+) IN HI, and pin 2, (–) IN LO, of J1. Note: Common mode voltage must not exceed ±2Vdc. Differential signals are defined as inputs whose two terminals are both above and below J1, pin 6 (GROUND). 5. Span (Gain) and Zero (Offset) Adjustments: Locations are included on the DMS-EB to add user-supplied potentiometers R4 and R5, and resistor R3. Recommended values for these components are as follows: R3: 10.5KΩ, 1%, 1/8W metal film; R4: 2KΩ, 10-20-turns; R5: 50KΩ, 10-20 turns. Vishay's T93YA series potentiometers are suitable for this application. Make sure to use only RoHS-compliant components and solders when making modifications to DMS-EB. Figure 3. Installing R1 A typical value for R1 is 1MΩ. The sum of R1 + R2 should be between 50kΩ and 10MΩ. R2 = (FSI x R1) / ( |VIN| - FSI) Where: FSI = The attenuated voltage, between the meter's (–) IN LO and (+) IN HI pins, needed to achieve the desired display readings VIN = Input voltage at J1 (between pins 1 and 2) Once installed, these components permit the span and zero adjustments described in the following sections. R3 and R4 provide span adjust, while R5 applies and offset voltage to (-) IN LO (J1, pin 2). www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MPM_DMS-EB.B01 Page 3 of 4 DMS-EB Multi-Purpose Application Board for DMS-30 & DMS-40 Series Meters APPLICATIONS 7.1. Install R2: R2 = FSR / (IMAX. x 10000) where FSR is the desired meter reading (0 -1999) and IMAX is between 0 -1 Ampere. Example VIN is 0-5Vdc, and the display reading must be "000" to "1500." 7.2. Open SG5. 1. Assume R1 = 1.0MΩ. 7.3. Configure the DMS-EB for span adjust using the procedure previously outlined for the DMS-30-0 version. 2. R2 = (FSI x R1) / ( |VIN| - FSI) R2 = (1.500 x 1,000,000) / (5.0 - 1.500) R2 = 428,571Ω or 432kΩ 7.4. Apply input signal (current) to (+) IN HI and (–) IN LO. 7.5. Adjust R4 for desired full scale readings. 3. Calibrate the meter using a known voltage source. Adjust R4 to compensate for variations in R1 and R2. 7.6. Enable the appropriate decimal point using either SG1, SG2, SG3 or SG-17. 7. Current Measurements (Use 200mV Model, DMS-30-0): The following instructions are for measuring current derived from the DMS30/40's power source. When measuring current that is floating with respect to J1, pin 6 (POWER RETURN), leave SG5 closed. Example A 0.100 Ampere input must read "100.0" on the display. CAUTION: Do not exceed 1 Ampere input current R2 = 1000 / (0.1 x 10000) R2 = 1 Ohm Enable DP3 via SG3 for a reading of "100.0." HI LO TST TST +V (+) (–) IN OUT –V GND Figure 4. DMS-EB Board USA: Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: [email protected] ISO 9001 and 14001 REGISTERED 12/15/08 Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2008 Murata Power Solutions, Inc. www.murata-ps.com Mansfield (MA), Tel: (508) 339-3000, email: [email protected] Canada: Toronto, Tel: (866) 740-1232, email: [email protected] UK: Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected] France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected] Germany: München, Tel: +49 (0)89-544334-0, email: [email protected] Japan: Tokyo, Tel: 3-3779-1031, email: [email protected] Osaka, Tel: 6-6354-2025, email: [email protected] China: Shanghai, Tel: +86 215 027 3678, email: [email protected] Guangzhou, Tel: +86 208 221 8066, email: [email protected] Singapore: Parkway Centre, Tel: +65 6348 9096, email: [email protected] Technical enquiries email: [email protected], tel: +1 508 339 3000 MPM_DMS-EB.B01 Page 4 of 4