CUI VWRAT2-D24-D15-SMT

rev.
description
features
Designed to convert a wide input
voltage range into an isolated
regulated voltage, the
VWRAT2-SMT series is well
suited for providing board-mount
local supplies in a wide range of
applications, including mixed
analog/digital circuits, test &
measurement equip.,
process/machine controls,
datacom/telecom fields, etc...
·wide (2:1) input range
·regulated
·dual voltage output
·I/O isolation: 1500 V dc
·no heatsink required
·short circuit protection
·MTBF >1,000,000 hours
·temperature range: -40°C~+85°C
MODEL
notes:
1.
1 of 3
date
date
05/2010
DESCRIPTION: dc-dc converter
PART NUMBER: VWRAT2
VWRAT2-D12-D5-SMT
VWRAT2-D12-D9-SMT
VWRAT2-D12-D12-SMT
VWRAT2-D12-D15-SMT
VWRAT2-D24-D5-SMT
VWRAT2-D24-D9-SMT
VWRAT2-D24-D12-SMT
VWRAT2-D24-D15-SMT
page
page
nominal
(V dc)
input voltage
range
(V dc)
max.
(V dc)
12
12
12
12
24
24
24
24
9.0~18.0
9.0~18.0
9.0~18.0
9.0~18.0
18.0~36.0
18.0~36.0
18.0~36.0
18.0~36.0
22
22
22
22
40
40
40
40
output voltage
(V dc)
±5
±9
±12
±15
±5
±9
±12
±15
output current
max.
min.
(mA)
(mA)
±200
±111
±83
±67
±200
±111
±83
±67
±20
±11
±8
±7
±20
±11
±8
±7
efficiency
typ.
(%)
76
78
80
79
77
79
80
79
All specifications measured at TA=25°C, humidity <75%, nominal input voltage and rated output load unless otherwise specified.
INPUT
parameter
input voltage range
conditions/description
min
12
24
nom
9~18
18~36
max
22
40
units
V dc
V dc
conditions/description
min
0.2
nom
max
2
±2
75
±0.5
±1.0
0.03
units
W
%
mVpp
%
%
%/°C
KHz
OUTPUT
parameter
2W output power
voltage accuracy
ripple & noise
line regulation
load regulation
temperature coefficient
switching frequency
refer to recommended circuit
@ 20MHz Bandwidth
input voltage from low to high
10% to 100% full load
refer to recommended circuit
100% load, nominal input
±1
35
±0.2
±0.5
300
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-todate product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair
or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty.
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383
www.v-infinity.com
page
2 of 3
date
05/2010
DESCRIPTION: dc-dc converter
PART NUMBER: VWRAT2
GENERAL SPECIFICATIONS
parameter
output short circuit protection
temperature rise at full load
cooling
operating temp. range
storage temp. range
reflow soldering temp.
storage humidity range
MTBF
conditions/description
Hiccup, automatic recovery
15°C typ., 35°C max.
free air convection
-40°C ~ +85°C
-55°C ~ +125°C
245°C (for 10 seconds)
≤95%
>1,000,000 hours
ISOLATION SPECIFICATIONS
parameter
isolation voltage
isolation resistance
isolation capacitance
conditions/description
flash tested for 1 minute
test at 500 V dc
Input/Output
min
1500
1000
nom
max
units
V dc
MΩ
PF
85
P in
0.50[0.020]
15.24[0.600]
-Vin
7
NC
8
0V
+Vo
9
10
23.86[0.939]
3.04[0.120]
1
2.54[0.100]
- Vo
1
7
8
13.7 0[0 .539 ]
( Top View)
1 8.10 [0.7 13]
16
NC: No conne ction
7
8
2.54[0.100]
1.00[0.039]
No te:
Un it :m m [in ch]
P in sectio n toler ances:±0 .10m m [ ±0.00 4inch]
Gener al t olera nces:±0. 25m m [ ±0.01 0inch]
5
0.25[0.010]
1
+Vin
16
10 9
10 9
16
2.1 0[0. 083 ]
1.02[0.040]
F OOT P RINT DE TA I LS
1 7.22 [0.6 78]
(Side View)
2.5 4[0 .100 ]
8 .00[0 .31 5]
7 .50 [0.29 5]
OUTLINE DIMENSIONS & FOOTPRINT
18.10[0.713]
1.40±0.20
[0.055±0.008]
RECOMMENDED REFLOW PROFILE
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383
www.v-infinity.com
page
3 of 3
date
05/2010
DESCRIPTION: dc-dc converter
PART NUMBER: VWRAT2
- Input current
Application Notes:
Nominal input voltage range. The input
current of the power supply must be sufficient
- All of the VWRAT2-SMT Series have been tested
according to the following recommended testing
to the startup current (Ip) of the DC/DC module
circuit before leaving the factory. This series should
(Figure 2)
be tested under load (Figure 1). If you want to
Figure 2
further decrease the input/output ripple, you can
increase capacitance properly or choose capacitors
with low ESR. However, the capacitance should not
be too high(Table 1).
Figure 1
+Vout
+Vin
Cout
Cin
DC
DC
Com
- Output Load
Cout
-Vin
-Vout
In order to ensure the product operates
efficiently and reliably, make sure the specified range
of input voltage is not exceeded.
- Recommended circuit
It is best to test with full load and not to test without load. To
No parallel connection or plug and play.
further reduce output ripple, you may increase the external
capacitor, choose a capacitor with low ESR, or add external
inductor to the circuit as shown above.
- NC Terminals
General:
Unless otherwise specified, NC terminals of all series
Cin: 12V 100μF
are used for converter's interior circuit
connection, and are not allowed connection of any
24V 10μF to 47μF
external circuit.
Cout:see Table 1
Temperature Derating Curve
Table 1
Dual
Vout
(VDC)
5
Cout
(uF)
9
470
12
330
15
220
560
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383