Source C-13-622-T3-SFC 622 mbps single mode transceiver Datasheet

622 Mbps Single Mode Transceiver
C-13-622-T(3)-SFC
Features
• FC Duplex Single Mode Transceiver
• Industry Standard 1x9 Footprint
• Complies with SONET OC-12 SDH STM-4
• Single +3.3V/+5V Power Supply
• OperatingTemperature Range: 0 to 70ºC
• LVPECL/PECL Differential Inputs and Outputs
• LVPECL/PECL Signal Detection Output
• Wave Solderable and Aqueous Washable
• Uncooled laser diode with MQW structure
• Complies with Telcordia (Bellcore) GR-468-CORE
• SONET OC-12 Application
• RoHS compliance available
Absolute Maximum Rating
Parameter
Symbol
Min.
Max.
Unit
Power Supply Voltage
Vcc
0
3.6
V
C-13-622-T3-SFC
Power Supply Voltage
Vcc
0
6
V
C-13-622-T-SFC
Output Current
Iout
0
30
mA
-
-
260
ºC
Tstg
-40
85
ºC
Soldering Temperature
Storage Temperature
Note
10 seconds on leads only
Recommended Operating Condition
Parameter
Symbol
Min.
Typ.
Max.
Unit
Power Supply Voltage
Vcc
3.1
3.3
3.5
V
C-13-622-T3-SFC
Power Supply Voltage
Vcc
4.75
5
5.25
V
C-13-622-T-SFC
Operating Temperature (Case)
Topr
0
-
70
ºC
-
-
622
-
Mbps
Symbol
Min
Typical
Max
Unit
Po
-15
-
-8
dBm
C-13-622-T(3)-SFC
C-13-622-T(3)-SFC4
Data Rate
Note
Transmitter Specifications
Parameter
Optical
Optical Transmit Power
Optical Transmit Power
Po
-3
-
+2
dBm
Output center Wavelength
λp
1274
1310
1356
nm
∆λrms
-
-
2.5
nm
ER
8.2
-
-
dB
Output Spectrum Width
Extinction Ratio
Output Eye
Notes
RMS(σ)
Compliant with ITU-T G.957/STM-4 Eye Mask
Optical Rise Time
tr
-
-
1.2
ns
10% to 90% Values
Optical Fall Time
tf
-
-
1.2
ns
10% to 90% Values
RIN
-
-
-120
dB/Hz
TJ
-
-
0.55
ns
Relative Intensity Noise
Total Jitter
LUMINENTOIC.COM
Measured with 223-1 PRBS with 72 ones and
72 zeros.
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
1
LUMNDS802-Oct1606
Rev. A.2
622 Mbps Single Mode Transceiver
C-13-622-T(3)-SFC
Transmitter Specifications
Parameter
Electrical
Symbol
Min
Typical
Max
Unit
Power Supply Current
ICC
-
-
180
mA
Data Input Current-Low
IIL
-350
-
-
µA
Notes
Maximum current is specified at Vcc=
Maximum @ maximum temperature
Data Input Current-High
IIH
-
-
350
µA
Differential Input Voltage
VIH-VIL
300
-
-
mV
Data Input Voltage-Low
VIL-VCC
-2.0
-
-1.58
V
Data Input Voltage-High
VIH-VCC
-1.1
-
-0.74
V
These inputs are compatible with 10K, 10KH
and 100K ECL and PECL inputs
Symbol
Min
Typical
Max
Unit
Notes
-
-
-
-28
dBm
Pin
-3
-
-
dBm
Receiver Specifications
Parameter
Optical
Sensitivity
Maximum Input Power
Measured with 223-1 PRBS,BER= 10-10
Signal Detect-Asserted
Pa
-
-
-28
dBm
Measured on transition: low to high
Signal Detect-Deasserted
Pd
-40
-
-
dBm
Measured on transition: high to low
1
-
5
dB
1100
-
1600
nm
Symbol
Min
Typical
Max
Unit
Note
ICC
-
-
100
mA
The current excludes the output load current
Data output Voltage-Low
VOL -Vcc
-2
-
-1.58
V
Signal Detect-Hysteresis
Wavelength of Operation
Receiver Specifications
Parameter
Electrical
Power Supply Current
Data Output Voltage-High
VOH- Vcc
-1.1
-
-0.74
V
Signal Detect Output Voltage-Low
VSDL-Vcc
-2.0
-
-1.58
V
Signal Detect Output Voltage-High
VSDH- Vcc
-1.1
-
-0.74
V
LUMINENTOIC.COM
These outputs are compatible with 10K,
10KH and 100KECL and PECL outputs
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
2
LUMNDS802-Oct1606
Rev. A.2
622 Mbps Single Mode Transceiver
C-13-622-T(3)-SFC
Connection Diagram
1. (Rx GND)
2. (Rx +)
3. (Rx-)
4. (SD)
5. (Rx Vcc)
6. (Tx Vcc)
7. (TX-)
8. (TX+)
9. (Tx GND)
NC
Top View
NC
Receiver Signal Ground
Receiver Data Out
Receiver Data Out Bar
Signal Detect
Receiver Power Supply
Transmitter Power Supply
Transmitter Data In Bar
Transmitter Data in
Transmitter Signal Ground
PIN
Symbol
1
RxGND
2
RD+
See recommended circuit schematic
3
RD-
See recommended circuit schematic
4
SD
5
RxVcc
6
TxVcc
DC power for the transmitter section
7
TD-
See recommended circuit schematic
8
Warnings
TD+
See recommended circuit schematic
9
LUMINENTOIC.COM
Notes
Directly connect this pin to the receiver ground plane
Active high on this indicates a received optical signal
DC power for the receiver section
TxGND
Directly connect this pin to the transmitter ground plane
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
3
LUMNDS802-Oct1606
Rev. A.2
622 Mbps Single Mode Transceiver
C-13-622-T(3)-SFC
Recommended Circuit Schematic
C-13-622-T(3)-SFC
Tx Vcc
C5
Rx Vcc
7 6 5
9 8
R1
4 3 2
1
R3
R9
R5
C6
R7
TD +
RD +
TD -
RD -
Tx Vcc
SD
Rx Vcc
R2
R4
Notes +3.3V:
R1=R3=R5=R7=R9=130
R2=R4=R6=R8=R10=82
C1=C2=C3=C5=C6=0.1F
C4=10F
L1=L2=1H
No internal
connection
No internal
connection
Transceiver
Top view
R10
R6
R8
L1
Notes +5V:
R1=R3=R5=R7=R9=82
R2=R4=R6=R8=R10=130
C1=C2=C3=C5=C6=0.1F
C4=10F
L1=L2=1H
Vcc
C3
C1
L2
C4
C2
Rx Vcc
Tx Vcc
The split-loaded terminations for ECL signals need to be located at the input of devices receiving those ECL signals.
The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc.
A GND plane under the module is required for good EMI and sensitivity performance.
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
4
LUMNDS802-Oct1606
Rev. A.2
622 Mbps Single Mode Transceiver
C-13-622-T(3)-SFC
Package Diagram
Top View
Front View
Rear View
Side View
LUMINENTOIC.COM
Units: mm
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
5
LUMNDS802-Oct1606
Rev. A.2
622 Mbps Single Mode Transceiver
C-13-622-T(3)-SFC
Ordering Information
Available Options:
C-13-622-T3-SFC
C-13-622-T-SFC
C-13-622-T3-SFC-G5
C-13-622-T-SFC-G5
C-13-622-T3-SFC4
C-13-622-T-SFC4
C-13-622-T3-SFC4-G5
C-13-622-T-SFC4-G5
Part unmbering Definition:
C - 13 - 622 - T(3) - S
FC
Tx Power
-RoHS
• Wavelength
13= 1310 nm
• Communication protocol
(622 Mbps)
• T3 = +3.3V Transceiver, FP
T = +5V Transceiver, FP
• Single mode fiber
• Connector options
• Tx Power range
Blank = -15 to -8 dBm
4 = -3 to +2 dBm
• Ordering Information
Blank = RoHS non-compliant product
G5 = RoHS 5/6-compliant product (lead exemption)
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
6
LUMNDS802-Oct1606
Rev. A.2
622 Mbps Single Mode Transceiver
C-13-622-T(3)-SFC
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow
guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance
of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are
given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of
Sale for further warranty information.
LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual
property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes
no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers
using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from
such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any
actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.
© LuminentOIC, Inc. 2003
All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
7
LUMNDS802-Oct1606
Rev. A.2
Similar pages