Astec AXO20A48-L 120watts dc-dc converter Datasheet

Astec Industry Standard
120Watts
Total Power:
Input Voltages:
No. of Outputs:
120 Watts
48V
Single
AEO/ALO40
High Efficiency
Electrical Specs
Input
Input Range
Input Surge
Input UVLO
36 to 75 VDC
100V /100ms
33 - 36 V (UVLO ON)
31 - 34 V (UVLO OFF)
Efficiency2
93% @ 5 V (typical)
Output
Special Features
•
•
•
•
•
•
•
2.3” x 0.9” Industry Standard 8th brick outline
Baseplate or Openframe construction
Low Ripple and Noise
Regulation to zero load
High Capacitive Load start-up
Fixed Frequency Switching for EMI predictability
Industry Standard features: Input UVLO with
hysteresis, Enable, OVP, OCP, OTP, Output
VoltageTrim, Differential Remote Sense
• Meets Basic Insulation
• EU Directive 2002/95/EC compliant for RoHS
Line / Load Regulation
< 0.1% VO (typical)
Load Current
Up to 40A for Vo ≤ 1.8V
Noise/Ripple1
30mVPK-PK (typical)
Transient Response
Over Voltage Protection
2% typical deviation
(50% to 75% Step Load)
< 100µs settling time (typ)
130% VO Typ (autorecovery)
Over Current Protection
130% IO,max Typ (autorecovery)
Over Temperature
Protection
Switching Frequency
Isolation Voltage
115ºC average PCB temperature
(autorecovery)
Fixed Frequency
1500Vdc
Control
Output Voltage Trim
±10% VO,NOM
Enable
TTL compatible
(Positive or Negative Logic)
Environmental
Operating Ambient Temperature
Openframe: -40°C to +85°C Ambient
Baseplate: -40°C to +100°C Case
Storage temperature: -55°C to +125°C
MTBF: > 1 Million Hrs
Safety
UL, cUL 60950-1 Recognized
TUV EN60950-1 Licensed
2
North America (USA): 1-888-41-ASTEC
Europe (UK): 44 (1384) 842-211
Asia (HK): 852-2437-9662
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
AEO / ALO40
Ordering Information
Input Voltage
36V
36V
36V
36V
36V
36V
36V
to
to
to
to
to
to
to
Output Voltage
75V
75V
75V
75V
75V
75V
75V
OPTIONS:
(X) : “L” =
“E” =
(N) : "N" =
(6) : “-6” =
Efficiency2
Output Current
12.0V
5.0V
3.3V
2.5V
1.8V
1.5V
1.2V
10A
20A
30A
35A
40A
40A
40A
Model Number
93.0%
92.0%
91.0%
89.5%
88.0%
86.0%
85.0%
A (X)O10B48 (N)
A (X)O20A48 (N)
A (X)O30F48 (N)
A (X)O35G48 (N)
A (X)O40Y48 (N)
A (X)O40M48(N)
A (X)O40K48 (N)
-
(6)(S)(L)
(6)(S)(L)
(6)(S)(L)
(6)(S)(L)
(6)(S)(L)
(6)(S)(L)
(6)(S)(L)
Open Frame / Low Profile
Baseplate Construction
designates Negative Logic Enable (default is Positive Enable with no suffix “N” required)
3.7mm nominal pin length (default is 5mm nominal pin length with no suffix “-6” required)
(S) : “-S”= Surface Mount Termination (default is Through Hole Termination with no suffix “-S” required)7
(L) : “L” = RoHS compliant (RoHS 6) / “Blank” - RoHS compliant with Lead (PB) in solder exemption (RoHS 5)
ALO - OPENFRAME
Pin Assignment
2.19
[55.5]
0.15
[3.8]
Single Output
1. +Vin
2. Enable (On/Off)
3. -Vin
4. -VOUT
5. -Sense
6. Trim
7. +Sense
8. +VOUT
0.15
[3.8]
0.30
[7.6]
0.45
[11.4]
0.45
[11.4] 0.60
[15.2] 0.75
[19.1]
0.75
[19.1]
SMT - Termination
0.15
[3.9]
0.31
[7.9]
TH - Termination
0.32
[8.2]
Notes:
Astec reserves the right to make changes to the information
contained herein without notice and assumes no liability as a
result of its use and application. (REV 02: MARCH 7, 2007)
www.astecpower.com
PIN LENGTH
See A
A
Std Pin Length: 0.189 [4.8] MIN
0.205 [5.2] MAX
“-6” Option:
AEO -BASEPLATE
0.15
[3.8]
0.15
[3.8]
2.00
[50.8]
0.30
[7.6]
0.45
[11.4]
0.45
[11.4]
0.75
[19.0]
PIN 1
PIN 8
SMT - Termination
0.15
[3.9]
0.39
[9.8]
PIN SIDE DOWN
TH - Termination
0.137 [3.5] MIN
0.152 [3.9] MAX
0.40
[10.1]
0.23
[5.8]
0.60
[15.2]
0.75
[19.0]
Astec Industry Standard
1. Measured at 20 MHz bandwidth with external 10 µF
tant. capacitor in parallel with 0.1 µF ceramic
capacitor connected across +Vout and -Vout; 220 µF
e-cap or equivalent connected across +Vin and -Vin.
2. Efficiency measurements are typical values taken at
full load, nominal line and TA = 25°C.
3. All specifications are typical at nominal line, full load
and TA = 25°C unless otherwise noted.
4. All specifications subject to change without notice.
5. Mechanical drawings are for reference only.
Dimensions are in inches [mm]. Pin placement
tolerance ± 0.005 [0.127]. Mechanical Tolerance ±
0.02 [0.5], recommended surface mount pads (min:
0.080 x 0.112 [2.03 x 2.84] / max: 0092 x 0.124
[2.34 x 3.15]); through hole pin diameter (Pins 4 & 8)
∅ = 0.062 [1.57], others ∅ = 0.04 [1.0] (6X).
6. Technical Reference Notes should be consulted for
detailed information when available.
7. AEOxxxxxx-Sx series (surface mount termination
with baseplate) are not reflow compatible.
8. Warranty 2 yrs.
See A
3
Similar pages