XTAL AXIOM60 Miniature ocxo with stratum iii stability option Datasheet

Issue: 06
Date: 2005-07-15
Specification
AXIOM60
Oscillator type :
Miniature OCXO with Stratum III stability option
Parameter
min.
max.
10
40
10.0 / 12.8 / 19.440
Frequency range
Standard frequencies
Frequency stability
Initial tolerance
vs. temperature
operating temperature range
EFC slope (∆f / ∆VC)
EFC linearity
EFC input impedance
RF output
Signal waveform
Load
Rise & decay time
Symmetry (duty cycle)
Warm-up time
Supply voltage VS
1.65
2.5
Positive
10
Option II = “S3”
Option II “100” & “200”
Option II = “S3”
3.15
4.75
ppm
V
V
N.A. for Option II= “S3”
Option I = “33”
Option I = “50”
100
HCMOS
15
Current consumption
(steady state @ +25°C)
Current consumption (warm-up)
Operable temperature range
Storage temperature range
Enclosure (see drawing) (LxWxH)
Weight
Packing
ESD Sensitivity
Condition
± 40
± 0.5
± 4.6
± 10
± 10
±2
0.15
0.25
Unit
MHz
MHz
ppm
ppb
ppb
ppb
ppb
°C
°C
ppb
ppb
ppb
ppm/y
ppm
± 500
± 280
± 200
± 100
+70
+60
-20
-10
vs. supply voltage variation
vs. load change
24 hour drift 3
Long term stability per year
(overall) 2 15 years
Frequency adjustment range
Electronic Frequency Control (EFC)4
EFC voltage4 VC
Notes:
1.
2.
3.
4.
typ.
10
40
60
2
3.13
3.3
3.47
4.75
5.0
5.25
150
200
100
150
500
350
-30
+75
-40
+85
14.4 x 9.5 x 8.5 max.
5
Tape & Reel
1500
@+25°C, VC= center
Option II = “S3”
Option II = “200”
Option II = “100”
Option II “S3” & “200”
Option II = “100”
%
kΩ
pF
ns
%
min
V
mA
mA
mA
mA
°C
°C
mm
gram
V
@ VS/2
∆ffinal/f0 < ±0.1 ppm
Option I = “33”
Option I = “50”
Option I = “33”
Option I = “50”
Option I = “33”
Option I = “50”
CO 27 (IEC 61837)
HBM as in IEC 610004-2
Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Overall frequency stability = temp.stability + supply & load change + aging
24 hours drift including VS ± 5%. ±2.78°C and daily aging
No voltage control function (EFC) provided in Stratum III version (Option II = “S3”)
Ordering Code:
Model (Specification)
AXIOM60
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Option I:
Option II:
Supply Voltage Stability
33
100
AXIOM60
page 1(2)
Frequency [MHz]
12.800
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections
Pin # Symbol
1
VC or
N.C.*
2
I.C.
3
GND
4
RF OUT
6
VS
Function
Voltage Control (EFC) or
No Connection*
Internal Connection
Ground
RF Output
Supply Voltage
Note:
For Option II = “S3”:
Pin 1 = N.C. (No Connection)
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIOM60
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Similar pages