AIMTEC AM40E-4812DZ 40 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM40E-Z
40 Watt | DC-DC Converter
FEATURES:




Wide 2:1 Input Range
Adjustable Single Output Voltage
Undervoltage lockout
High Power Density



Efficiency up to 92%
Remote On/Off Function
Soft start
Models
Single output
Model
Input Voltage
(V)
Output Voltage
(V)
AM40E-1203SZ
9-18
AM40E-1205SZ
9-18
AM40E-1212SZ
9-18
AM40E-1215SZ
9-18
AM40E-2403SZ
18-36
AM40E-2405SZ
18-36
AM40E-2412SZ
18-36
AM40E-2415SZ
18-36
AM40E-4803SZ
36-75
AM40E-4805SZ
36-75
AM40E-4812SZ
36-75
AM40E-4815SZ
36-75
Add suffix “-K” for optional heat sink
Output Current
max (A)
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
8
8
3.33
2.67
8
8
3.33
2.67
8
8
3.33
2.67
Maximum
Capacitive load
(µF)
Efficiency
(%)
21800
13600
2300
1500
21800
13600
2300
1500
21800
13600
2300
1500
90
91
91
91
91
92
91
92
91
92
91
92
Maximum
Capacitive load
(µF)
Efficiency
(%)
Models
Dual output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
AM40E-1212DZ
9-18
±12
±1.67
±1200
91
AM40E-1215DZ
9-18
±15
±1.33
±750
92
AM40E-2412DZ
18-36
±12
±1.67
±1200
91
AM40E-2415DZ
18-36
±15
±1.33
±750
92
AM40E-4812DZ
36-75
±12
±1.67
±1200
92
AM40E-4815DZ
36-75
±15
±1.33
±750
92
Add suffix “-K” for optional heat sink
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Start up time
Absolute Maximum Rating
Peak Input Voltage time
On/Off control
Under voltage lockout
Input Reflected Ripple Current
www.aimtec.com
F 051e R12.D
Nominal
12
24
48
Typical
9-18
18-36
36-75
π (Pi) Network
30
Maximum
Units
VDC
ms
25
50
VDC
100
1
s
ON: 3 ~12VDC or open circuit ; OFF – 0 ~ 1.2VDC or Short circuit between pin 2 and pin 3
(OFF idle current: 5mA Typical)
12V ON/OFF
8.6 / 7.9
24V ON/OFF
17.8 / 16
VDC
48V ON/OFF
33.5 / 30.5
20
mA p-p
12
24
48
Tel: +1 514 620 2722
1 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40E-Z
40 Watt | DC-DC Converter
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Case/Input and Output
Resistance
Capacitance
Typical
3 sec
3 sec
Rated
Units
1600
VDC
VDC
MOhm
pF
1600
<1000
1000
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
Cross Regulation (Dual Output Models)
Over voltage protection
Over load protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
25% load on one output
100% load on second load
3.3Vout/5Vout
other models
Voltage adjustment range (single)
Minimum Load Current
Units
%
±5
%
Zener diode clamp
130
Continuous
Auto-Recovery
±0.5
±0.5
±1
±0.02
100
150
HL-LL
0% to 100% load
0% to 100% load
Ripple & Noise (20MHz Bandwidth)
Maximum
±1
% of Iout
%
%
%
%/oC
mV p-p
±10
0
%
% of Max
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
Conditions
Typical
100% load
See derating chart
Maximum
Units
270
-40 to +71
-40 to +125
105
2.5
Free Air Convection
95
Nickel coated Copper
32
2.00 x 1.00 x 0.40 inches
50.80 x 25.40 x 10.16 mm
>328,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC)hours
1.5mm from case for 10 sec
260
250
±3
KHz
o
C
o
C
o
C
%/ oC
% RH
g
o
C
µS
%
Safety Specifications
Parameters
Agency Approval
Safety
www.aimtec.com
F 051e R12.D
CE
EN55022: 2006 + A1:2007, Class B
IEC61000-3-2:2006+A2:2009
IEC61000-3-3:2008
EN55024:1998 + A1:2001 + A2:2003
IEC61000-4-2: 2008
IEC61000-4-3:2006+A1: 2007
IEC61000-4-4:2004
IEC61000-4-5:2005
IEC61000-4-6:2008
IEC61000-4-8:2009
NOTE: also designed to meet IEC 60950-1:2001
Tel: +1 514 620 2722
2 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40E-Z
40 Watt | DC-DC Converter
Pin Out Specifications
Pin
1
2
3
4
5
6
Single
+ V Input
- V Input
On/Off Control
+ V Output
-V Output
Trim
Dual
+ V Input
- V Input
On/Off Control
+ V Output
Common
- V Output
10.16
(0.40)
2.54
(0.10)
5.08
(0.20)
5.08
(0.20)
5.08
(0.20)
10.16
(0.40)
10.16
(0.40)
25.40
(1.00)
10.16
(0.40)
Dimensions
Dimensions with Optional Heatsink
Notes: Add “-K” suffix for ordering, heat sink is affixed with thermally dissipative adhesive tape.
See derating graph for temperature performance. Heat sink material is anodized (black) aluminum, adds weight 11.2g to
total mass (42.2g). Thermal impedance of converter is: with heat sink 10Ԩ/W and 12Ԩ/W without heat sink.
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
3 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40E-Z
40 Watt | DC-DC Converter
Trimming
Derating
Extended temperature performance can be achieved with optional heat sink. (add suffix “–K” to part number)
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
4 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40E-Z
40 Watt | DC-DC Converter
Input Reflected Ripple Current Test Step
Output Ripple and noise reduction
Control ON/OFF pin connection example
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
5 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40E-Z
40 Watt | DC-DC Converter
EMI Filter
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
6 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40E-Z
40 Watt | DC-DC Converter
Model
AM40E-12xxSZ
(single)
AM40E-24xxSZ
(single)
AM40E-48xxSZ
(single)
AM40E-12xxDZ
(dual)
AM40E-24xxDZ
(dual)
AM40E-48xxDZ
(dual)
C1
220µF,
100V
220µF,
100V
220µF,
100V
220µF,
100V
220µF,
100V
220µF,
100V
L1
Common
Choke 68µH
Common
Choke 68µH
Common
Choke 68µH
Common
Choke 68µH
Common
Choke 68µH
Common
Choke 68µH
C2/C3/C5/C6
1812,6.8µF,
50V
1812,4.7µF,
50V
1812,1.5µF,
50V
1812,6.8µF,
50V
1812,4.7µF,
50V
1812,1.5µF,
50V
C4
C7
C8
C9
1206,1000pF,
2KV
1206,1000pF,
2KV
1206,1000pF,
2KV
1206,1000pF,
2KV
1206,1000pF,
2KV
1206,1000pF,
2KV
1206,1000pF,
2KV
1206,1000pF,
2KV
1206,1000pF,
2KV
1206,1000pF,
2KV
1206,1000pF,
2KV
330µF, 100V
220µF, 100V
220µF, 100V
330µF, 100V
220µF, 100V
220µF, 100V
EFT/Surge
+V output
+V input
C1
DC/DC
Converter
Load
220uF
100V
-V input
-V output
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
7 of 7
Toll free: + 1 888 9 AIMTEC