CUI ETS1201000U Ac-dc power supply Datasheet

date
08/13/2012
page
1 of 5
SERIES: ETS 120~150 W │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
up to 150 W power
universal input (90~264 Vac)
single regulated output from 12~24 V
over load and short circuit protections
UL/cUL and TUV safety approvals
level V efficiency
custom designs available
RoHS
MODEL
ETS1201000U
output
voltage
output
current
output
power
ripple1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
12
10
120
200
efficiency
level
V
ETS135890U
13.5
8.9
120.2
200
V
ETS150830U
15
8.3
124.5
200
V
ETS160810U
16
8.1
129.6
200
V
ETS180750U
18
7.5
135
250
V
ETS190750U
19
7.5
142.5
250
V
ETS200710U
20
7.1
142
250
V
ETS240625U
24
6.25
150
250
V
Notes:
1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 μF aluminum electrolytic and 0.1 μF ceramic capacitors.
PART NUMBER KEY
ETS135890U - T C - P51 - ET - CXX
Base Number
example of 13.5 Vdc, 8.9 A
AC Input Plug:
blank = IEC 320 C14 plug
T = IEC 3210 C6 plug
Input Cable:
C = included
blank = no cable
cui.com
4 position
“Power DIN”
Reserved for Custom
Configurations
Factory
Designation
CUI Inc │ SERIES: ETS 120~150 W │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/13/2012 │ page 2 of 5
INPUT
parameter
conditions/description
min
voltage
90
frequency
47
typ
current
inrush current
at 230 Vac, cool start
no load power consumption
power factor correction
complies with IEC 61000-3-2 class D, at 100 Vac
harmonic standard, input power > 75W, at 240 Vac
0.95
0.9
conditions/description
min
max
units
264
Vac
63
Hz
2.5
A
100
A
0.5
W
max
units
OUTPUT
parameter
load regulation
typ
±5
%
140
%
140
%
PROTECTIONS
parameter
conditions/description
over voltage protection
over current protection
short circuit protection
auto restart
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
isolation voltage
input to output at 10 mA for 1 second
safety approvals
UL/cUL (60950-1), EN 60950-1/IEC 60950-1, CSA C22 60950-1-03
EMI/EMC
FCC Part 15 Class B, CE, CNS 13438 class B, CISPR 22 class B, EN 55022; EN 55024; EN 61000-(2, 3);
IEC 61000-4-(2, 3, 4, 5, 6, 8, 11)
RoHS compliant
yes
MTBF
max
units
1,800
Vac
40,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
max
units
0
40
°C
storage temperature
-20
85
°C
operating humidity
20
80
%
0
90
%
operating temperature
storage humidity
cui.com
typ
CUI Inc │ SERIES: ETS 120~150 W │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/13/2012 │ page 3 of 5
MECHANICAL
parameter
conditions/description
dimensions
3.173 x 1.969 x 1.220 (80.6 x 50 x 31 mm)
min
input plug
IEC320 / C14
weight
typ
MECHANICAL DRAWING
units: mm
Optional:
IEC 320 C6 input plug
cui.com
units
inch
115
Standard:
IEC 320 C14 input plug
max
g
CUI Inc │ SERIES: ETS 120~150 W │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/13/2012 │ page 4 of 5
AC CORD
C6
C14
cui.com
CUI Inc │ SERIES: ETS 120~150 W │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/13/2012 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
10/22/2010
1.01
V-Infinity branding removed, safety and EMI/EMC data updated
08/13/2012
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
Similar pages