Series AMEOF3-JZ O 3 Watt | AC-DC Converter Picture Coming Soon FEATURES: • • • • Input: 85-264VAC, 47-440Hz or 70-400VDC Operating temperature -40°C to +85°C Low power consumption ≤ 0.5W Continuous short circuit protection • • • • I/O Isolation 3000VAC Ultra slim open frame SIP Over current protection Class II power supply Models Single output Input Voltage (VAC/Hz) Input Voltage (VDC) Full power temperature range (ºC) Output Voltage (V) Output Current max (mA) Maximum capacitive load (µF) Efficiency (%) AMEOF3-3.3SJZ AMEOF3-5SJZ AMEOF3-9SJZ AMEOF3-12SJZ AMEOF3-15SJZ AMEOF3-24SJZ 85-264/47-440 85-264/47-440 85-264/47-440 85-264/47-440 85-264/47-440 85-264/47-440 70-400 70-400 70-400 70-400 70-400 70-400 -20 to +55 -20 to +55 -20 to +55 -20 to +55 -20 to +55 -20 to +55 3.3 5 9 12 15 24 500 500 333 250 200 125 470 470 150 100 100 100 63 68 75 77 78 80 AMEOF3-3.3SLJZ AMEOF3-5SLJZ AMEOF3-9SLJZ AMEOF3-12SLJZ AMEOF3-15SLJZ AMEOF3-24SLJZ 85-264/47-440 85-264/47-440 85-264/47-440 85-264/47-440 85-264/47-440 85-264/47-440 70-400 70-400 70-400 70-400 70-400 70-400 -20 to +55 -20 to +55 -20 to +55 -20 to +55 -20 to +55 -20 to +55 3.3 5 9 12 15 24 500 500 333 250 200 125 470 470 150 100 100 100 63 68 75 77 78 80 Model NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Current Inrush current <2ms External fuse Input dissipation Input filter Conditions Typical 115VAC 230VAC 115VAC 230VAC Recommended slow blow type No Load Maximum 120 60 13 23 1 0.5 Recommended external π (Pi) filter Units mA mA A A A W Output Specifications Parameters Voltage accuracy Line regulation Load regulation Ripple & Noise Minimum load current Conditions Typical Full load, 3.3V output Full load, others Full load 10% - 100% load 20MHz Bandwidth Maximum Units ±8 ±5 % ±1.5 ±2.5 150 10 % % mV p-p % of Max Isolation Specifications Parameters Tested I/O voltage Isolation Resistance www.aimtec.com F 052e R0 Conditions Typical 60 sec >1000 Tel: +1 514 620 2722 1 of 4 Rated Units 3000 VAC MΩ Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOF3-JZ O 3 Watt | AC-DC Converter General Specifications Parameters Conditions Switching frequency Over current protection Short circuit protection Short circuit restart Operating temperature Storage temperature Temperature coefficient Cooling Humidity Weight Dimensions (L x W x H) MTBF Typical Maximum Units 60 ≥110 Continuous Auto-recovery -40 to +85 -40 to +105 ±0.15 Free air convection KHz % of I out 85 7 1.38 x 0.71 x 0.43 inches 35 x 18 x 11 mm o >300,000 hours (MIL-HDBK -217F, Ground Benign, t=+25 C) % RH g Auto-recovery See derating curve °C °C % / °C Safety Specifications Parameters IEC/EN/UL60950-1 pending approval EN 55022, Class A & B, with external filter circuits, as referenced IEC 61000-4-2, Contact ±4KV, Criteria B IEC 61000-4-3, 10V/m, Criteria A, with Class B external filter, as referenced IEC 61000-4-4, ±2KV/±4KV, Criteria B, with Class A/B external filter referenced IEC 61000-4-5, ±1KV/±2KV, Criteria B, with Class A/B external filter referenced IEC 61000-4-6, 10Vrms, Criteria A, with Class B external filter, as referenced IEC 61000-4-8, 10A/m, Criteria A, with Class B external filter, as referenced IEC 61000-4-11, 0-70%, Criteria B, with Class B external filter, as referenced Pin Out Specifications* 35.00 (1.38) * Add capacitor between pin 5 & 7. Application circuit below. 1 3 5 7 10 1.15 (0.05) 5.08 (0.20) www.aimtec.com F 052e R0 11.00 (0.43) 12 10.00 (0.39) 1.30 (0.05) 1.75 (0.07) 1 3 5 7 10 12 Dimensions Single AC N AC L +V sc -V sc -V Output +V Output 18.00 (0.71) Pin 0.50 (0.02) Standards Note: Unit: mm (inch) Pin diameter tolerance: ±0.10 (±0.004) Case tolerance: ±0.50 (±0.02) 27.94 (1.10) Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOF3-JZ O 3 Watt | AC-DC Converter L models 35.00 (1.38) 18.00 (0.71) Top view 1 5 3 10 7 Note: Unit: mm (inch) Pin diameter tolerance: ±0.10 (±0.004) Case tolerance: ±0.50 (±0.02) 12 1.30 (0.05) Right view 11.00 (0.43) Front view 5.08 (0.20) 27.94 (1.10) 6.00 (0.24) 1.60 (0.06) 0.80 (0.03) 0.40 (0.02) Derating* Free Air Convection at 25°C Free Air Convection 100 80 Output Power (%) Output Power (%) 100 Safe Operating Area 100% load 110-240VAC Or 100-340VDC 60 40 20 60 Safe Operating Area 40 20 0 - 40 80 - 20 0 20 40 55 60 80 85 0 100 85 110 (70) (100) Ambient Temperature º C 240 (340) 264 (400) Input Voltage VAC (VDC) *Power derating: -40 to -20 increase 1%/°C 55 to 85 decrease 0.67%/°C www.aimtec.com F 052e R0 Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOF3-JZ O 3 Watt | AC-DC Converter Recommended EMC class A external circuit: AC L FUSE 1A/250V Single Output L1 4.7mH NTC C1 10µF/450V MOV S14K350 12 3 + L2 2.2µH 5 AC + DC +Vout C3 + C2 TVS C4 0.1µF/50V 7 AC N 1 10 - Vout Pi filter CY1 1nF/400VAC Recommended EMC class B external circuit: AC L FUSE 1A/250V LDM 0.33mH LCM 3.5mH CX 0.1µF/ 275VAC MOV S14K350 AC N CY2 1nF/ 400VAC CY3 1nF/ 400VAC Single Output NTC 24 Vout +Vout 5 C1 4.7µF/ 450V AC + DC C2 C3 + 7 1 10 TVS C4 0.1µF/50V - Vout Pi filter GND Model 3.3 Vout 5 Vout 9 Vout 12 & 15 Vout 12 3 + L2 2.2µH CY1 1nF/400VAC C2 330 µF / 25V 150 µF / 35V 100 µF / 35V C3 120 µF / 25V TVS 7V 12V 68 µF / 35V 20V 30V Note: For Safety compliance we recommend minimum PCB trace distance of 3mm, minimum distance between PCB traces of 6mm, primary to secondary circuit traces distance between minimum of 6.4mm. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4 . All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R0 Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only