Data Delay DDU37F-120M Mechanically variable ttl delay line Datasheet

DDU37F
data 3 
delay
devices, inc.
MECHANICALLY VARIABLE
TTL DELAY LINE
(SERIES DDU37F)
FEATURES
•
•
•
PACKAGES
Ideal for “Set and Forget” applications
Multi-turn adjustment screw (approx. 40 turns)
Input & output fully TTL interfaced & buffered
2
(10 T L fan-out capability)
Resolution:
As low as 0.12ns
Minimum delay (TD0):
6ns typical
Output rise time:
2ns typical
Min. input pulse width:
20% of maximum delay
Power dissipation:
230mW maximum
Operating temperature:
0° to 70°C (Commercial)
-55° to 125°C (Military)
Temperature coefficient: 100 PPM/°C
•
•
•
•
•
•
•
VCC OUT
NC
DDU37F
IN
GND
DDU37F-xx
(Commercial)
DDU37F-xxM (Military)
xx = Dash number
FUNCTIONAL DESCRIPTION
PIN DESCRIPTIONS
The DDU37F-series device is a mechanically variable, FAST-TTL interfaced
delay line. The signal input (IN) is reproduced at the tap output (OUT), shifted
by an amount which can be adjusted between TD0 and TD0+ TDVAR, where
TDVAR is given by the device dash number (See Table). The device operates
from a single 5V supply and is TTL interfaced, capable of driving up to 10
TTL loads.
SERIES SPECIFICATIONS
IN
OUT
VCC
GND
NC
Signal Input
Fixed Output
+5V
Ground
No connection
DASH NUMBER
SPECIFICATIONS
IN
OUT
Part
Number
DDU37F-25
DDU37F-30
DDU37F-40
DDU37F-50
DDU37F-60
DDU37F-70
DDU37F-80
DDU37F-100
DDU37F-120
DDU37F-150
DDU37F-200
GND
Functional Diagram
VCC OUT
NC
.565
MAX
IN
Note: Other delay times
available on request
GND
1.750
.187
.285
.200
MIN
.020
.100
.200
TDVAR
(ns)
15
20
30
40
50
60
70
90
100
130
180
.125
.100
.060
.100
.430
.060
1.640
Package Dimensions
Doc #01016
11/12/01
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
 2001 Data Delay Devices
1
DDU37F
APPLICATION NOTES
Delay Devices if your application requires device
testing at a specific input condition.
HIGH FREQUENCY RESPONSE
The DDU37F tolerances are guaranteed for input
pulse widths and periods greater than those
specified in the test conditions. Although the
device will function properly for pulse widths as
small as 20% of the total delay and periods as
small as 40% of the total delay (for a symmetric
input), the delays may deviate from their values at
low frequency. However, for a given input
condition, the deviation will be repeatable from
pulse to pulse. Contact technical support at Data
POWER SUPPLY BYPASSING
The DDU37F relies on a stable power supply to
produce repeatable delays within the stated
tolerances. A 0.1uf capacitor from VCC to GND,
located as close as possible to the VCC pin, is
recommended. A wide VCC trace and a clean
ground plane should be used.
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER
DC Supply Voltage
Input Pin Voltage
Storage Temperature
Lead Temperature
SYMBOL
VCC
VIN
TSTRG
TLEAD
MIN
-0.3
-0.3
-55
MAX
7.0
VDD+0.3
150
300
UNITS
V
V
C
C
NOTES
10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 70C, 4.75V to 5.25V)
PARAMETER
High Level Output Voltage
SYMBOL
VOH
Low Level Output Voltage
VOL
High Level Output Current
Low Level Output Current
High Level Input Voltage
Low Level Input Voltage
Input Clamp Voltage
Input Current at Maximum
Input Voltage
High Level Input Current
Low Level Input Current
Short-circuit Output Current
Output High Fan-out
Output Low Fan-out
IOH
IOL
VIH
VIL
VIK
IIHH
Doc #01016
11/12/01
IIH
IIL
IOS
MIN
2.5
TYP
3.4
MAX
UNITS
V
0.35
0.5
V
-1.0
20.0
0.8
-1.2
0.1
mA
mA
V
V
V
mA
20
-0.6
-150
25
12.5
µA
mA
mA
Unit
Load
2.0
-60
NOTES
VCC = MIN, IOH = MAX
VIH = MIN, VIL = MAX
VCC = MIN, IOL = MAX
VIH = MIN, VIL = MAX
VCC = MIN, II = IIK
VCC = MAX, VI = 7.0V
VCC = MAX, VI = 2.7V
VCC = MAX, VI = 0.5V
VCC = MAX
DATA DELAY DEVICES, INC.
Tel: 973-773-2299
Fax: 973-773-9672
http://www.datadelay.com
2
DDU37F
DELAY LINE AUTOMATED TESTING
TEST CONDITIONS
INPUT:
o
o
Ambient Temperature: 25 C ± 3 C
Supply Voltage (Vcc): 5.0V ± 0.1V
Input Pulse:
High = 3.0V ± 0.1V
Low = 0.0V ± 0.1V
Source Impedance:
50Ω Max.
Rise/Fall Time:
3.0 ns Max. (measured
between 0.6V and 2.4V )
Pulse Width:
PWIN = 1.5 x Total Delay
Period:
PERIN = 10 x Total Delay
OUTPUT:
Load:
Cload:
Threshold:
1 FAST-TTL Gate
5pf ± 10%
1.5V (Rising & Falling)
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
OUT
PULSE
GENERATOR
IN
DEVICE UNDER
TEST (DUT)
IN
OUT
TRIG
TRIG
OSCILLOSCOPE
Test Setup
PERIN
PWIN
TRISE
INPUT
SIGNAL
TFALL
VIH
2.4
1.5
0.6
2.4
1.5
0.6
VIL
DRISE
OUTPUT
SIGNAL
DFALL
VOH
1.5
1.5
VOL
Timing Diagram For Testing
Doc #01016
11/12/01
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
3
Similar pages