CRCW-HP e3 www.vishay.com Vishay Draloric Pulse Proof, High Power Thick Film Chip Resistors FEATURES • • • • • Excellent pulse load capability Enhanced power rating Double side printed resistor element Protective overglaze Pure tin solder contacts on Ni barrier layer provides compatibility with lead (Pb)-free and lead containing soldering processes • AEC-Q200 qualified, rev. C compliant • Material categorization: For definitions of compliance please see www.vishay.com/doc?99912 STANDARD ELECTRICAL SPECIFICATIONS MODEL CASE CASE SIZE SIZE INCH METRIC CRCW0402-HP e3 0402 RR1005 CRCW0603-HP e3 0603 RR1608 CRCW0805-HP e3 0805 RR2012 CRCW1206-HP e3 1206 RR3216 CRCW1210-HP e3 1210 RR3225 CRCW1218-HP e3 1218 RR3246 CRCW2010-HP e3 2010 RR5025 CRCW2512-HP e3 2512 RR6332 POWER RATING P70 W LIMITING ELEMENT VOLTAGE Umax. AC/DC TEMPERATURE COEFFICIENT ppm/K TOLERANCE % RESISTANCE RANGE SERIES ± 0.5, ± 1 ±5 1 to 1M E24; E96 E24 ± 0.5, ± 1 ±5 1 to 1M E24; E96 E24 ± 0.5, ± 1 ±5 1 to 1M E24; E96 E24 ± 0.5, ± 1 ±5 1 to 1M E24; E96 E24 ± 0.5, ± 1 ±5 1 to 1M E24; E96 E24 ± 0.5, ± 1 ±5 1 to 1M E24; E96 E24 ± 0.5, ± 1 ±5 1 to 1M E24; E96 E24 ± 0.5, ± 1 ±5 1 to 1M E24; E96 E24 ± 100 ± 200 Zero-Ohm-Resistor: Rmax. = 0.010 , Imax. = 3 A ± 100 0.25 75 ± 200 Zero-Ohm-Resistor: Rmax. = 0.008 , Imax. = 5 A ± 100 0.33 150 ± 200 Zero-Ohm-Resistor: Rmax. = 0.005 , Imax. = 6 A ± 100 0.5 200 ± 200 Zero-Ohm-Resistor: Rmax. = 0.005 , Imax. = 10 A ± 100 0.75 200 ± 200 Zero-Ohm-Resistor: Rmax. = 0.004 , Imax. = 12 A ± 100 1.5 200 ± 200 Zero-Ohm-Resistor: Rmax. = 0.004 , Imax. = 20 A ± 100 1.0 400 ± 200 Zero-Ohm-Resistor: Rmax. = 0.005 , Imax. = 12 A ± 100 1.5 500 ± 200 Zero-Ohm-Resistor: Rmax. = 0.005 , Imax. = 16 A 0.125 (1) 50 Notes • These resistors do not feature a limited lifetime when operated within the permissible limits. However, resistance value drift increasing over operating time may result in exceeding a limit acceptable to the specific application, thereby establishing a functional lifetime. • Marking: See document “Surface Mount Resistor Marking” (document number 20020). • Power rating depends on the max. temperature at the solder point, the component placement density and the substrate material. (1) CRCW0402-HP resistors feature a single side printed resistive layer only. TECHNICAL SPECIFICATIONS PARAMETER UNIT CRCW CRCW CRCW CRCW CRCW CRCW CRCW CRCW 0402-HP 0603-HP 0805-HP 1206-HP 1210-HP 1218-HP 2010-HP 2512-HP Rated dissipation P70 (2) W 0.125 0.25 0.33 0.5 0.75 1.5 1.0 1.5 Limiting element voltage Umax. AC/DC V 50 75 150 200 200 200 400 500 Insulation voltage Uins. (1 min) V > 75 > 100 > 200 > 300 > 300 > 300 > 300 > 300 Insulation resistance 31 25.5 42 Category temperature range °C Weight mg > 109 - 55 to + 155 0.65 2 5.5 10 18 Note (2) The power dissipation on the resistors generates a temperature rise against the local ambient, depending on the heat flow support of the printed-circuit board (thermal resistance). The rated dissipation applies only if the permitted film temperature of 155 °C is not exceeded. Revision: 21-Mar-13 Document Number: 20043 1 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 CRCW-HP e3 www.vishay.com Vishay Draloric PART NUMBER AND PRODUCT DESCRIPTION Part Number: CRCW0603562RFKEAHP (1) C R C W MODEL/SIZE CRCW0402 CRCW0603 CRCW0805 CRCW1206 CRCW1210 CRCW1218 CRCW2010 CRCW2512 0 6 0 3 VALUE R = Decimal K = Thousand M = Million 0000 = Jumper 5 6 2 TOLERANCE D = ± 0.5 % F=±1% J=±5% Z = Jumper R F K E A H P TCR K = ± 100 ppm/K N = ± 200 ppm/K 0 = Jumper PACKAGING EA EB EC ED EE EF EG EH EK SPECIAL Up to 2 digits HP = Pulse proof, high power Product Description: CRCW0603-HP 100 562R 1 % ET1 e3 CRCW0603-HP 100 562R 1% ET1 e3 MODEL CRCW0402-HP CRCW0603-HP CRCW0805-HP CRCW1206-HP CRCW1210-HP CRCW1218-HP CRCW2010-HP CRCW2512-HP TCR ± 100 ppm/K ± 200 ppm/K RESISTANCE VALUE 10R = 10 562R = 562 10K = 10 k 1M = 1 M 0R0 = Jumper TOLERANCE ± 0.5 % ±1% ±5% PACKAGING ET1 ET5 ET6 ET7 EF4 EG1 E02 E67 E82 ET9 LEAD (Pb)-FREE e3 = Pure tin termination finish Note (1) Preferred way for ordering products is by use of the PART NUMBER. PACKAGING MODEL PAPER TAPE ON REEL ACC. TO IEC 60286-3, TYPE I UNIT BLISTER TAPE ON REEL ACC. TO IEC 60286-3, TYPE II QUANTITY PART NUMBER PRODUCT DESC. QUANTITY PART NUMBER PRODUCT DESC. 10 000 50 000 ED EE ET7 EF4 180 mm/7" CRCW0603-HP 285 mm/11.25" 330 mm/13" 5000 10 000 20 000 EA EB EC ET1 ET5 ET6 180 mm/7" CRCW0805-HP 285 mm/11.25" 330 mm/13" 5000 10 000 20 000 EA EB EC ET1 ET5 ET6 180 mm/7" CRCW1206-HP 285 mm/11.25" 330 mm/13" 5000 10 000 20 000 EA EB EC ET1 ET5 ET6 180 mm/7" CRCW1210-HP 285 mm/11.25" 330 mm/13" 5000 10 000 20 000 EA EB EC ET1 ET5 ET6 CRCW0402-HP 180 mm/7" 330 mm/13" CRCW1218-HP 180 mm/7" 4000 EK ET9 CRCW2010-HP 180 mm/7" 4000 EF E02 CRCW2512-HP 180 mm/7" 2000 4000 EG EH E67 E82 Revision: 21-Mar-13 Document Number: 20043 2 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 CRCW-HP e3 www.vishay.com Vishay Draloric DIMENSIONS in millimeters b l a SIZE SOLDER PAD DIMENSIONS DIMENSIONS REFLOW SOLDERING WAVE SOLDERING INCH METRIC L W H T1 T2 a b l 0402 1005 1.0 ± 0.05 0.5 ± 0.05 0.3 ± 0.1 0.25 ± 0.1 0.2 ± 0.1 0.4 0.6 0.5 a b l 0603 1608 1.6 ± 0.1 0.85 ± 0.1 0.45 ± 0.1 0.3 ± 0.2 0.3 ± 0.2 0.5 0.9 1.0 0.9 0.9 1.0 0805 2012 2.0 ± 0.15 1.25 ± 0.15 0.50 ± 0.1 0.4 ± 0.2 0.35 ± 0.2 0.7 1.3 1.2 0.9 1.3 1.3 1206 3216 3.1 ± 0.2 1.6 ± 0.15 0.50 ± 0.15 0.5 ± 0.2 0.45 ± 0.2 0.9 1.7 2.0 1.1 1.7 2.3 1210 3225 3.2 ± 0.2 2.5 ± 0.2 0.6 ± 0.1 0.45 ± 0.2 0.4 ± 0.2 0.9 2.5 2.0 1.1 2.5 2.2 1218 3246 3.1 ± 0.2 4.6 ± 0.2 0.6 ± 0.1 0.45 ± 0.2 0.4 ± 0.2 1.05 4.9 1.9 1.25 4.8 1.9 2010 5025 5.0 ± 0.15 2.5 ± 0.15 0.6 ± 0.1 0.6 ± 0.2 0.6 ± 0.2 1.0 2.5 3.9 1.2 2.5 3.9 2512 6332 6.3 ± 0.2 3.15 ± 0.15 0.6 ± 0.1 0.6 ± 0.2 0.6 ± 0.2 1.0 3.2 5.2 1.2 3.2 5.2 FUNCTIONAL PERFORMANCE Pulse Load Pmax. (W) Single Pulse 10 000 2512 1218 2010 1210 1206 0805 0603 0402 1000 100 10 1 0.1 0.01 0.000001 0.00001 0.0001 0.001 0.01 0.1 1 10 100 Pulse Duration ti (s) Maximum pulse load, single pulse; applicable if P 0 and n < 1000 and Û Ûmax.; for permissible resistance change equivalent to 8000 h operation Revision: 21-Mar-13 Document Number: 20043 3 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 CRCW-HP e3 www.vishay.com Vishay Draloric Continuous Pulse Load Pmax. (W) Continuous Pulse 10 000 2512 1218 2010 1210 1206 0805 0603 0402 1000 100 10 1 0.1 0.01 0.000001 0.00001 0.0001 0.001 0.01 0.1 1 10 100 Pulse Duration ti (s) Maximum pulse load, continuous pulses; applicable if P P (amb) and Û Ûmax.; for permissible resistance change equivalent to 8000 h operation Pulse Voltage Ûmax. (V) Pulse Voltage 2000 1800 2512 1600 1400 2010 1200 1000 800 1206/1210/1218 600 400 0805 0603 200 0402 0 0.000001 0.00001 0.0001 0.001 0.01 0.1 1 10 Pulse Duration ti (s) Maximum pulse voltage, single and continuous pulses; applicable if Pˆ Pˆ max . ; for permissible resistance change equivalent to 8000 h operation Fraction of Rated Dissipation in % DERATING 120 100 80 60 40 20 0 - 55 Revision: 21-Mar-13 - 25 0 25 50 75 70 100 125 155 175 Ambient Temperature in °C Document Number: 20043 4 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 CRCW-HP e3 www.vishay.com Vishay Draloric TEST PROCEDURES AND REQUIREMENTS EN 60115-1 CLAUSE IEC 60068-2 TEST METHOD TEST PROCEDURE STABILITY CLASS 2 OR BETTER Stability for product types: CRCW-HP e3 4.5 - Resistance - 4.7 - Voltage proof U = 1.4 x Uins; 60 s 4.13 - REQUIREMENTS PERMISSIBLE CHANGE (R) Short time overload U = 2.5 x 1 to 1 M ± 0.5 %, ± 1 %, ± 5 % P 70 x R 2 × Umax.; duration: According to style ± (0.5 % R + 0.05 ) Solder bath method; Sn60Pb40; non-activated flux; (235 ± 5) °C; (2 ± 0.2) s Good tinning ( 95 % covered) no visible damage Solder bath method; Sn96.5Ag3Cu0.5; non-activated flux; (245 ± 5) °C; (3 ± 0.3) s Good tinning ( 95 % covered) no visible damage 4.17.2 58 (Td) Solderability 4.8.4.2 - Temperature coefficient (20/- 55/20) °C and (20/125/20) °C ± 100 ppm/K, ± 200 ppm/K No visible damage 4.32 21 (UU3) Shear (adhesion) RR 1608 and smaller: 9 N RR 2012 and larger: 45 N 4.33 21 (UU1) Substrate bending Depth 2 mm; 3 times No visible damage, no open circuit in bent position ± (0.25 % R + 0.05 ) 4.19 14 (Na) Rapid change of temperature 30 min. at - 55 °C; 30 min at 125 °C 5 cycles 1000 cycles ± (0.5 % R + 0.05 ) ± (1 % R + 0.05 ) - Dry heat - 4.23.2 4.23 2 (Ba) Damp heat, cyclic 125 °C; 16 h 55 °C; 90 % RH; 24 h; 1 cycle 4.23.3 30 (Db) cold 4.23.4 1 (Aa) Low air pressure - 55 °C; 2 h 4.23.5 13 (M) - 1 kPa; (25 ± 10) °C; 1 h 4.23.6 30 (Db) Damp heat, cyclic 55 °C; 90 % RH; 24 h; 5 cycle 4.23.7 - D.C. load 4.25.1 - Endurance at 70 °C 4.18.2 U = U = ± (2 % R + 0.1 ) P 70 x R P 70 x R U max. 1.5 h on; 0.5 h off; 70 °C; 1000 h 70 °C; 8000 h ± (2 % R + 0.1 ) ± (4 % R + 0.1 ) 58 (Td) Resistance to soldering heat Solder bath method; (260 ± 5) °C; (10 ± 1) s ± (0.5 % R + 0.05 ) 4.35 - Flammability, needle flame test IEC 60695-15-5; 10 s No burning after 30 s 4.24 78 (Cab) Damp heat, steady state (40 ± 2) °C; (93 ± 3) % RH; 56 days ± (1 % R + 0.05 ) 4.25.3 - Endurance at upper category temperature 155 °C; 1000 h ± (2 % R + 0.1 ) 4.40 - Electrostatic discharge (human body model) IEC 61340-3-1; 3 positive and 3 negative discharges; ESD voltage according to size ± (1 % R + 0.05 ) 4.29 45 (XA) Component solvent resistance Isopropyl alcohol; 50 °C; method 2 No visible damage Marking legible, no visible damage ± (0.5 % R + 0.05 ) 4.30 45 (XA) Solvent resistance of marking Isopropyl alcohol; 50 °C; method 1; toothbrush 4.22 6 (Fc) Vibration, endurance by sweeping f = 10 Hz to 2000 Hz; x, y, z 1.5 mm; A 200 m/s2; 10 sweeps per axis 4.37 - Periodic electric overload 4.27 - Single pulse high voltage overload, 10 μs/700 μs U = 15 x P 70 x R 2 x U max. 0.1 s “ON”; 2.5 s “OFF”; 1000 cycles Û = 10 x P 70 x R 2 x U max. 10 pulses ± (1 % R + 0.05 ) ± (1 % R + 0.05 ) All tests are carried out in accordance with the following specifications: • EN 60115-1, generic specification • EN 140400, sectional specification • EN 140401-802, detail specification • IEC 60068-2, environmental test procedures Packaging of components is done in paper or blister tapes according to IEC 60286-3. Revision: 21-Mar-13 Document Number: 20043 5 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards. Revision: 02-Oct-12 1 Document Number: 91000