zFeatures
1) The built-in bias resistors consist of thin-film resistors with complete isolation to allow negative biasing of the input, and
parasitic effects are almost completely eliminated.
2) Only the on / off conditions need to be set for operation, making device design easy.
3) Higher mounting densities can be achieved.
zCircuit schematic
C
B
R
E
E : Emitter
C : Collector
B : Base
zAbsolute maximum ratings (Ta=25°C)
Parameter
Collector-base voltage
Collector-emitter voltage
Emitter-base voltage
Symbol
Limits
Unit
VCBO
VCEO
50
V
V
V
mA
VEBO
IC
Collector current
DTC144GE
Collector
Power
DTC144GUA / DTC144GKA
dissipation
DTC144GSA
Junction temperature
Storage temperature
50
5
100
150
Pc
200
mW
300
Tj
150
Tstg
−55 to +150
C
C
zPackage, marking, and packaging specifications
Part No.
DTC144GE DTC144GUA DTC144GKA DTC144GSA
Package
Marking
EMT3
K26
UMT3
K26
SMT3
K26
SPT
−
Packaging code
Basic ordering unit (pieces)
TL
3000
T106
3000
T146
3000
TP
5000
Rev.A
1/2
DTC144GE / DTA144GUA / DTC144GKA / DTC144GSA
Transistors
zElectrical characteristics (Ta=25°C)
Symbol
Min.
Typ.
Max.
Unit
Collector-emitter breakdown voltage
BVCBO
BVCEO
50
50
−
−
−
−
V
V
IC=50µA
IC=1mA
Emitter-base breakdown voltage
Parameter
Collector-base breakdown voltage
Conditions
BVEBO
5
−
−
V
IE=160µA
Collector cutoff current
ICBO
−
0.5
µA
Emitter cutoff current
Collector-emitter saturation voltage
IEBO
−
−
130
0.3
µA
V
VCB=50V
VEB=4V
VCE(sat)
−
65
−
hFE
68
−
−
−
R
32.9
−
47
250
61.1
−
kΩ
−
MHz
VCE=10V , IE= −5mA , f=100MHz ∗
DC current transfer ratio
Emitter-base resistance
Transition frequency
∗ Transition frequency of the device.
fT
IC=10mA , IB=0.5mA
IC=5mA , VCE=5V
1k
VCE=5V
Ta=100°C
DC CURRENT GAIN : hFE(V)
500
Ta=25°C
200
100
50
Ta= −40°C
20
10
5
2
1
100µ 200µ
500µ 1m
2m
5m
10m 20m
50m 100m
COLLECTOR CURRENT : IC (A)
Fig.1 DC current gain
vs. Collector current
COLLECTOR SATURATION VOLTAGE : VCE(sat) (V)
zElectrical characteristics curves
1
IC/IB=20/1
500m
Ta=100°C
Ta=25°C
200m
100m
50m
Ta= −40°C
20m
10m
5m
2m
1m
100µ 200µ
500µ 1m
2m
5m
10m 20m
50m 100m
COLLECTOR CURRENT : IC (A)
Fig.2 Collector-Emitter saturation voltage
vs. Collector current
Rev.A
2/2
Appendix
Notes
No technical content pages of this document may be reproduced in any form or transmitted by any
means without prior permission of ROHM CO.,LTD.
The contents described herein are subject to change without notice. The specifications for the
product described in this document are for reference only. Upon actual use, therefore, please request
that specifications to be separately delivered.
Application circuit diagrams and circuit constants contained herein are shown as examples of standard
use and operation. Please pay careful attention to the peripheral conditions when designing circuits
and deciding upon circuit constants in the set.
Any data, including, but not limited to application circuit diagrams information, described herein
are intended only as illustrations of such devices and not as the specifications for such devices. ROHM
CO.,LTD. disclaims any warranty that any use of such devices shall be free from infringement of any
third party's intellectual property rights or other proprietary rights, and further, assumes no liability of
whatsoever nature in the event of any such infringement, or arising from or connected with or related
to the use of such devices.
Upon the sale of any such devices, other than for buyer's right to use such devices itself, resell or
otherwise dispose of the same, no express or implied right or license to practice or commercially
exploit any intellectual property rights or other proprietary rights owned or controlled by
ROHM CO., LTD. is granted to any such buyer.
Products listed in this document are no antiradiation design.
The products listed in this document are designed to be used with ordinary electronic equipment or devices
(such as audio visual equipment, office-automation equipment, communications devices, electrical
appliances and electronic toys).
Should you intend to use these products with equipment or devices which require an extremely high level of
reliability and the malfunction of with would directly endanger human life (such as medical instruments,
transportation equipment, aerospace machinery, nuclear-reactor controllers, fuel controllers and other
safety devices), please be sure to consult with our sales representative in advance.
About Export Control Order in Japan
Products described herein are the objects of controlled goods in Annex 1 (Item 16) of Export Trade Control
Order in Japan.
In case of export from Japan, please confirm if it applies to "objective" criteria or an "informed" (by MITI clause)
on the basis of "catch all controls for Non-Proliferation of Weapons of Mass Destruction.
Appendix1-Rev1.1
Similar pages