Amphenol EHRH Waterproof sensing element and housing Datasheet

®
EHRH
Waterproof RH Transmitter
The EHRH Relative Humidity Transmitter is a waterproof
RH sensing element and package which is ideally
suited for monitoring relative humidity in high RH/harsh
environment applications or where washdowns are
required. The unit is designed for continuous monitoring
of relative humidity and temperature and is available in
±2% accuracy.
Both the sensor and electronics are contained in an
epoxy-hardened enclosure designed for continuous
service. A water-tight membrane filter is installed over
the RH sensor for increased protection against high RH,
contaminants and washdowns. The unit is designed to
withstand 100% saturation.
Features
• Waterproof sensing element and housing
• Compact transmitter with built-in sensor
• Bulk polymer resistance RH sensor
• Resistant to contamination
• Thermistor temperature measurement
• Temperature compensation
The sensor incorporates a bulk polymer resistance
element. The polymer is impervious to most
contaminants and, since it is a bulk resistance device,
surface contamination such as dust will not alter the
accuracy of the readings.
Applications
The unit is provided with continuous temperature
compensation which adjusts for temperature-induced
change in the RH sensor output. The compensation
provides high measurement accuracy over the entire
operating range of the instrument.
• Food processing
• Greenhouses
• Textile mills
• Shipping containers
• Swimming pools
• Hospital suites
Amphenol
Advanced Sensors
EHRH Specifications
Humidity
Temperature
Sensing Element
Sensing Element
Resistance change of bulk polymer sensor
Accuracy at 77°F (25°C)
±2% RH. 30 to 95% RH including hysteresis, linearity,
and repeatability.
Temperature Effect
Less than 0.11% per ºF (0.06% per ºC)
Thermistor, 10 KΩ at 77°F (25ºC), two-wire
measurement
Accuracy at 77°F (25ºC)
±0.5ºF (±0.3ºC). Also available with 100 (RTD with 4 mA
to 20 mA analog output.
Sensitivity
Consult factory for further information
0.1% RH
Part Number Configuration
Repeatability
0.5% RH
Order
Codes:
[1]-[2]-[3]-[4]
Linearity
1
Model Designation
See accuracy
EHRH-2
Relative Humidity and 10K thermister outputs
Hysteresis
EHRHT-2
Relative Humidity and signal conditioned temperature
outputs
Less than 1%
2
Output(s)
Operating Range, Sensor & Electronics
I
Current (4-20mA) EHRH and EHRHT
0% to 100% RH, -20ºC to 54ºC (-4ºF to 129ºF)
V5
Voltage (0-5 VDC) EHRH only
V10
Voltage (0-10 VDC) EHRH only
Maximum Air Velocity
10,000 ft/minimum (3,048 m/minimum)
3
Wiring
Output Ranges
4 to 20 mA current, two-wire, loop-powered for 0 to
100%, RH (standard) into 0 to 900 Ω
4
F
Front, with waterproof connector
B
Back, flying leads
Temperature Channel Range (EHRHT Only)
1
-20°F to +140°F Temperature Rage (Standard Range)
2
0°F to +150°F Temperature Range
3
0°F to 100°F Temperature Range
±20%, non-interactive
4
+32°F to +132°F Temperature Range
Span
5
+50°F to +130°F Temperature Range
6
-40°F to +140°F Temperature Range
7
Custom Temperature Range
Adjustment
Zero
±10%, non-interactive
Long Term Stability
Less than 2% drift per year typical
Power Supply
Voltage
12 to 36 VDC
Wiring Connection
Deutsch four-position waterproof connector (For front
wiring only_flying leads for back wiring).
Amphenol
Advanced Sensors
Example:
EHRH-2-V5-F
RH transmitter with 10K thermistor, 2%
accurate RH, 0-5 volt RH output and front-wired
(waterproof connector).
All units have a standard 3-Point factory
calibration (30, 50, 80% RH @ 25°C) standard
relative humidity output range is 0 to 100%.
Standard temperature output range is –20°F
to +140°F. Standard relative humidity and
temperature output signal is 4-20 mA.
www.telaire.com
www.amphenol-sensors.com
© 2014 Amphenol Corporation. All Rights Reserved. Specifications are subject to change without notice.
Other company names and product names used in this document are the registered trademarks or
trademarks of their respective owners.
AAS-920-233D-03/2014