60W Single Output with Battery Charger (UPS Function) LPS ■ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ DRC-60 series Bauar t gepruft Sicherheit egel ma ge od o s be wac g www.tuv.com ID 2000000000 ■ ‧ ‧ ‧ ‧ • ‧ ■ ℃℃ ■ File Name:DRC-60-SPEC 2014-1122 60W Single Output with Battery Charger (UPS Function) DRC-60 series SPECIFICATION MODEL OUTPUT DRC-60A DRC-60B OUTPUT NUMBER CH1 CH2 CH1 CH2 DC VOLTAGE 13.8V 13.8V 27.6V 27.6V RATED CURRENT 2.8A 1.5A 1.4A 0.75A CURRENT RANGE 0 ~ 4.3A -------- 0 ~ 2.15A -------- RATED POWER 59.34W 59.34W RIPPLE & NOISE (max.) Note.2 120mVp-p VOLTAGE ADJ. RANGE -------- VOLTAGE TOLERANCE Note.3 ±1.0% -------- ±1.0% -------- LINE REGULATION ±0.5% -------- ±0.5% -------- LOAD REGULATION ±0.5% -------- ±0.5% -------- HOLD UP TIME (Typ.) 50ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 86% AC CURRENT (Typ.) 1.3A/115VAC INRUSH CURRENT (Typ.) OVERLOAD PROTECTION FUNCTION -------- CH1:24 ~ 30V SETUP, RISE TIME Note.4 400ms, 50ms/230VAC INPUT 200mVp-p CH1:12 ~ 15V OVER VOLTAGE 800ms, 50ms/115VAC at full load 10ms/115VAC at full load 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)] 88% 0.8A/230VAC COLD START 30A/115VAC 60A/230VAC 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:14.49 ~ 18.63V CH1:28.98 ~ 37.26V Protection type : Shut down o/p voltage, re-power on to recover BATTERY CUT OFF 10±0.5V AC OK Relay contact output, ON : AC OK ; OFF : AC Fail ; max. rating : 30V/1A BATTERY LOW 20±1V Relay contact output, OFF : Battery OK ; ON : Battery Low ; max. rating : 30V/1A Battery low voltage : < 11V WORKING TEMP. -30 ~ +70℃ (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 90% RH non-condensing Battery low voltage : < 22V ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃) on CH1 output VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH (Note 5) EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61204-3, light industry level, criteria A MTBF 504.1K hrs min. OTHERS DIMENSION PACKING NOTE MIL-HDBK-217F (25℃) 40*90*100mm (W*H*D) 0.3Kg; 42pcs/13.6Kg/0.82CUFT ℃ File Name:DRC-60-SPEC 2014-10-22 DRC-60 60W Single Output with Battery Charger (UPS Function) series Block Diagram RL1 AC OK RL2 Bat. Low ALARM CIRCUIT EMI FILTER & RECTIFIER I/P POWER SWITCHING RECTIFIERS & FILTER -V Bat. + DETECTION CIRCUIT PWM CONTROL O.L.P. +V Bat. Battery Charger & Back up Control O.V.P. Derating Curve Static Characteristics 100 100 90 80 80 230VAC Input only 70 LOAD (%) LOAD (%) 60 40 20 -30 -20 0 15 30 40 50 AMBIENT TEMPERATURE (℃) 60 70 (VERTICAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:DRC-60-SPEC 2014-10-22 DRC-60 60W Single Output with Battery Charger (UPS Function) series Suggested Application 1.Backup connection for AC interruption (1) Please refer to Fig1.1 for suggested connection. The power supply charges the battery and provides energy to the load at the same time when AC mains is OK. The battery starts to supply power to the load when AC mains fails. A : 12V B : 24V Battery + Bat+ Load - - + Bat- V+ V- DC OK + +V ADJ Fig 1.1 Suggested system connection 2.Alarm signal for AC OK and battery low (1) Alarm Signal is sent out through " AC OK " & " Battery Low " pins via relay contact. (2) An external voltage source is required for this function. The maximum applied voltage is 30V and the maximum sink current is 1A. Please refer to Fig 2.2. (3) Table2.1 explains the alarm function built in the power supply (4) AC OK signal (RL1,referring to Block Diagram) will go into hiccup mode when the overload protecton is activated. Function Output of alarm Description The signal is "Low" when the power supply turns ON. Low or short The signal turns to be "High" when the power supply turns OFF. High or open (External applied voltage 30V max.) The signal is "Low" when the voltage of battery is under A:11V, B:22V. Low or short The signal is "High" when the voltage of battery is above A:11V, B:22V. High or open (External applied voltage 30V max.) AC OK Battery Low Table 2.1 Explanation of alarm signal AC OK (Battery low) R V External voltage sorece (V) and resistor (R) (The max. Sink is 1A and 30V) Fig 2.2 Internal circuit of AC OK (Battery Low), via relay contact File Name:DRC-60-SPEC 2014-10-22 DRC-60 60W Single Output with Battery Charger (UPS Function) Mechanical Specification Case No.962A series Unit:mm 40 100 3.81×7 8 7 6 5 4 3 2 1 TB2 DC OK 90 + +V ADJ 3 TB1 2 1 7.5 7.5 Terminal Pin No. Assignment (TB1): Pin No. 1 2 3 Assignment AC/L or DC+ AC/N or DCFG Terminal Pin No. Assignment (TB2): Pin No. 1 2 3 Assignment -V +V Bat. + Pin No. 4 5,6 7,8 Assignment Bat. AC OK Bat. Low Installation Instruction 35 This series fits DIN rail TS35/7.5 or TS35/15. (This diagram is for reference. The rail is not included with unit.) Back View File Name:DRC-60-SPEC 2014-10-22