AIMTEC AM8T-1203SZ 8 watt | dc-dc converter Datasheet

Series AM8T-Z
8 Watt | DC-DC Converter
FEATURES:








RoHS compliant
24 Pin DIP Package
Wide 2:1 input range
Efficiency up to 85%
Operating temperature -40oC to + 85oC
Continuous Short Circuit Protection
Low ripple and noise
Input/output Isolation voltage 1500VDC
Models
Single output
Model
Input Voltage
(V)
AM8T-1203SZ
AM8T-1205SZ
AM8T-1212SZ
AM8T-1215SZ
AM8T-2403SZ
AM8T-2405SZ
AM8T-2412SZ
AM8T-2415SZ
AM8T-4803SZ
AM8T-4805SZ
AM8T-4812SZ
AM8T-4815SZ
Output Voltage
(V)
Output Current
max (mA)
Capacitive load
(μF)
Efficiency
(%)
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
2000
1500
665
535
2000
1500
665
535
2000
1500
665
535
3300
2200
470
220
3300
2200
470
220
3300
2200
470
220
80
82
85
83
80
82
85
84
80
82
84
84
Output Voltage
(V)
Output Current
max (mA)
Capacitive load
(μF)
Efficiency
(%)
±5
±12
±15
±5
±12
±15
±5
±12
±15
±800
±335
±265
±800
±335
±265
±800
±335
±265
±1000
±220
±100
±1000
±220
±100
±1000
±220
±100
82
84
84
82
83
85
82
85
85
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-72
36-72
36-72
36-72
Models
Dual output
Model
Input Voltage
(V)
AM8T-1205DZ
AM8T-1212DZ
AM8T-1215DZ
AM8T-2405DZ
AM8T-2412DZ
AM8T-2415DZ
AM8T-4805DZ
AM8T-4812DZ
AM8T-4815DZ
9-18
9-18
9-18
18-36
18-36
18-36
36-72
36-72
36-72
Input Specifications
Parameters
Voltage range
Nominal
Typical
12
24
48
9-18
18-36
36-72
Peak Input Voltage time
www.aimtec.com
F 051e R12.G
Units
VDC
 (Pi) Network
Filter
Turn on Transient process time
Start up time
Absolute Maximum Rating
Maximum
12 Vin
24 Vin
48 Vin

20
-0.7-24
-0.7-40
-0.7-100
100
Tel: +1 514 620 2722
1 of 3
350
ms
ms
VDC
ms
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM8T-Z
8 Watt | DC-DC Converter
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Case/input & Output
Resistance
Capacitance
Typical
Rated
Units
1500
VDC
VDC
MOhm
pF
Maximum
Units
3 sec
1000
> 1000
1000
Output Specifications
Parameters
Voltage accuracy
Voltage balance (Dual output model)
Short Circuit protection
Short Circuit restart
Current Limiting
Line voltage regulation
Load voltage regulation
Temperature coefficient
Rising time
Ripple and Noise
Conditions
Typical
Balanced Load
±1
±1
%
%
Continuous
Auto recovery
140 % of Iout max
HL-LL
10% to 100% load
±0.5
±0.5
±0.02
10
75
%
%
%/oC
ms
mVp-p
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
100% load
330
KHz
o
Operating temperature
With Derating above 55°C
-40 to +85
C
o
Storage temperature
-40 to +125
C
o
Max Case temperature
+100
C
Cooling
Free air convection
Humidity
95
%
Case material
Nickel coated cooper
Weight
17
g
Dimensions (L x H x W)
Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.80 x 0.40 inches
31.80 x 20.30 x 10.20 mm
MTBF
>1 121 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency Approval
Standards
www.aimtec.com
F 051e R12.G
CE
nd
IEC 60950-1:2005 (2 Edition); EN 60950-1:2006
EN55022 Class A, EN55024
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria B (external 220uF/100V cap required)
IEC61000-4-5, Perf. Criteria B (external 220uF/100V cap required)
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM8T-Z
8 Watt | DC-DC Converter
Single
Dual
2
3
9
11
14
16
22
23
-V Input
-V Input
No pin
N.C.
+V Output
-V Output
+V Input
+V Input
-V Input
-V Input
Common
-V Output
+ V Output
Common
+V Input
+V Input
3.05
(0.12)
10.20
(0.40)
Pin
15.24
(0.60)
Dimensions (Bottom view)
20.30
(0.80)
Pin Out Specifications
Derating
Test Circuits
Conducted Emissions:
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.G
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages